Loading...
HomeMy WebLinkAboutAPPROVED Single HungMIAMI•DADE MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building CGI Windows and Doors, Inc. 3780 W 104t' Street Hialeah, FL 33018 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I. APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window (LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E-1, E-2, E-3, E-4 and E-5, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 20-0722.09 MIAMI•DADE COUNTY Expiration Date: September 22, 2025 • ' Approval Date: September 10, 2020 9/1/20 Page 1 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 10-0510. 11) 2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)", sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7500 PVC fixed window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer(& insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 7400 PVC project out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal(V and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) 3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a series 238 aluminum fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E. (Submitted under NOA No.15-0512.09) Manuel Perez, P.E. Product Control Ex r NOA No. 20 0722.09 Expiration Date: September 2 Approval Date: September 10, 2020 E -l CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) B. TESTS (CONTINUED) 4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of a series "Sentinel" aluminum single hung window, prepared by Hurricane Test Laboratory, LLC, Test Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510.11) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 611 Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Glazing complies with ASTM E1300-09 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their "SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on 07/04/18. 2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17, expiring on 07/08/19. 3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 09/07/17, expiring on 12/11/18. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. Manuel Perez, P.E. Product Control Ex . er .1 NOA No. 20 0722.09 Expiration Date: September , 2 Approval Date: September 10, 2020 E-2 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED) F. STATEMENTS 1. Statement letter of conformance, complying with FBC 5" Edition (2014), and of no financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E. (Submitted under NOA No.17-1018.08) 2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu J. Abraham, P.E. (Submitted under NOA No. 10-0510. 11) 3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by Jaime Gascon, Supervisor. (Submitted under NOA No. 15-0512. 10) G. OTHERS 1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and expiring on 09/22/20. Manuel Pere Product Control Ex f NOA No. NO Expiration Date: September Ik Approval Date: September 1 E-3 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No SH110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)", sheets I through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. CGI Windows and Doors, Inc., representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: PGT Industries, Inc. test specimens: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E. CGI Windows and Doors Inc. test specimens: FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit I in proposal) FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal) FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal) FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal) all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 711 Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. Manuel Perez, P Product Control Ex J NOA No. 0722 Expiration Date: September 2,2. Approval Date: September 10, 2( E-4 CGI Windows and Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED (CONTINUED) D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their "Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19, expiring on 05/23/24. 2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19, expiring on 07/08/24. 3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA) for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET Core" dated 05/17/18, expiring on 12/11/23. 4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA) for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6t' Edition (2017) and the FBC 7t' Edition (2020), dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. 3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. 4. Notification of Successor Engineer for manufacturer's NOA document per Section 61G15-27.001 of the Florida Administrative Code, notifying original engineer that the successor engineer is assuming full professional and legal responsibility for all engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed by Anthony Lynn Miller, P.E. 5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10, 2020, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 12/21/17 and expiring on 09/22/20. t Manuel Perez, P.E: Product Control Ex r J NONo. 20 0722.09 Expiration Date: September , 2 Approval Date: September 10, 2020 E-5 r,x 1 /A" R9 1 /R" 2 6" MAX. HEAD/SILL CORNERS w M U- _ M v O zw \w M = to 1- n O M W M J > o FLANGE WIDTH 47 7/16" D.L.O. (FIX. LITE) 20 9/16" MAX. A HEAD/SILL II It II II II II 11 �l II II II 11 It II % II II II II II C II II j l FALSE MUNTINS `(SURFACE APPLIED) OPTIONAL 5 1 /2" MAX. / HEAD/SILL CORNERS w x J J M _ M O of F- 0 co x �n w = rY U - D m Z -,W to_ �> n v N cn M Z M O E1 J > 0 M � Q In m= w 47 7/16" a w to o D.L.O. (VENT) 50 1/4" VENT WIDTH FLANGE & FLANGE ADAPTOR FRAME BUCK WIDTH 47 7/16" D.L.O. (FIX. LITE) 20 9/16" MAX. HEAD/SILL Al V. II II II II � II II II II II II B II 1� it It n % n II II II II II 11 C l SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WINDOW LARGE & SMALL MISSILE (LM & SM) DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2. FALSE MUNTINS (SURFACE APPLIED) OPTIONAL 5 1/2" MAX. HEAD/SILL x w J D2 M � M O J F � U w Y U D m co ED E2 MLd = My N fn M Z M O \ X m -' > to FALSE MUNTINS 47 7/16" Q 'z (SURFACE APPLIED) D.L.O. (VENT) \ ''30 OPTIONAL In 50 1/4- VENT WIDTH EQUAL LEG FRAME APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER MIAMI-DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM. THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ). 1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED PRODUCT LOADS TO THE BUILDING STRUCTURE. ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY. ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE. MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS. THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC. CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL. BUCK WIDTH 47 7/16" D.L.O. (FIX. LITE) 20 9/16" MAX. A2 HEAD/SILL O W J o \Q m Q� g m� 47 7/16" N m z D.L.O. (VENT) \ 7)o 50 1/4" VENT WIDTH FIN FRAME �c *CENTER ANCHOR REQUIRED WHEN SPACING EXCEEDS 20 9/16" LAMINATED GLASS INSULATING LAM. GLASS SMALL MISSILE IMPACT LARGE MISSILE IMPACT REVISED FOR 2020 FBC, ADDED ANCHOR TYPE, •O BACKBEDDING & t REFORMATTED -JR- rr 07/07/20 O (v Y Q N C) •naa W O O J w � � O a}DQ *Cl U) Z J> N O w o Q0v J J O a QZ LL Q UA DJQ cl) w=w- w z � 0 0 a CO > > °N wIw- oW� w�> SMQ rn IL p adz°' z = w U Z J U C O c z }aa4s .�. v) 1= m to u+ 0 0 O W w R= Z�o Q U) Q= ujOco E3: O z O z w a�LL° Z � w cn O - _j� 0UMSM 5 ��Ju, R U) J W 2 (A alpi •osaQ sauas t111d ,rlp No53705 C1 'gyp "IATE � `F � //// /c)N 1y /jt{ilil\11 A. LYNN MILLER, P.E. P.E.# 58705 EQUAL IMS WINDOWS DESIGN LOAD CAPACITY - PSF FLANGE DIMS. BUCK DIMS. GLASS TYPES 'A'&'A1' GLASS TYPES 'B'&'Bl' WIDTH HEIGHT WIDTH HEIGHT EXT.(+) INT.(-) EXT.(+) INT.(-) 19-1/8" 26-1/2" 37" 49" 53-1/8" 26" 18-1/8" 25-1/2" 36" 48" 52-1/8" 25" 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 19-1 /8" 26-1/2" 37" 49" 53-1/8" 38-3/8" 18-1 /8" 25-1/2" 36" 48" 52-1/8" 37-3/8" 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 19-1/8" 26-1/2" 37" 49" 53-1/8" 50-5/8" 18-1/8" 25-1/2" 36" 48" 52-1/8" 49-5/8" 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 19-1/8" 26-1/2" 37" 49" 53-1/13" 63" 1 18-1/8" 25-1/2" 36" Q. 52-1/8" 62" 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 19-1/8" 26-1/2" 37" 49" 53-1/8" 76" 18-1/8" 25-1/2" 36" 48" 52-1/8" 75' 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 19-1/8" 26-1/2" 37" 46-1/2" 85" 18-1/8" 25-1/2" 36" 45-1/2" 84" 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 75.0 75.0 80.0 80.0 WinTw EQUAL LITES NOTE: GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION DECLARATORY STATEMENT DCA05-DEC-219. UNEQUAL LITES WINDOWS DESIGN LOAD CAPACITY - PSF FLANGE DIMS. BUCK DIMS. MA%TOP LITE GLASS TYPES 'A'&'Al' GLASS TYPES 'B'&'Bl' WIDTH HEIGHT WIDTH HEIGHT 'A' DIM. EXT.(+) INT.(-) EXT.(+) INT.(-) 53-1/8" 76" 52-1/8" 75" 36-1/4" 75.0 75.0 80.0 80.0 49" 79 48" 78" 39-1/4" 75.0 75.0 80.0 80.0 26-1/2" 31" 33" 37" 43" 85" 1 25-1/2" 30" 32" 36" 1 42" 84" 70-5/8" 75.0 75.0 80.0 00.0 63-5/8" 75.0 75.0 80.0 80.0 60" 75.0 75.0 80.0 80.0 53-1/2" 75.0 75.0 80.0 80.0 45-1/4" 75.0 75.0 1 80.0 80.0 Y TYP. UNEQUAL LITES (ORIEL TYPE) TYP. BUCK DIMS F z w FLANGE FRAME FLANGE DIMS cli BUCK DIMS g 0 p W Y g MW � m J EQUAL LEG FRAME BUCK DIMS FIN FRAME BUCK DIMS FLANGE ADAPTOR FRAME UNEQUAL LITES (ORIEL TYPE) c 0 cc o N Y Q N O naa w rn CDO N 0 a}np Z Ln O Z W JC7N o <( p v Qz U- to 0 UMDJp U) w Z U V o 00 ON < I- a uJ ��>� Ur UMp (L z = W rn W y U C O z J U N tC o U� Z }aa4S n oc U) W p 0 O W W m' Q p Q Q a,E cn=Mo O W I o § wZ o-iw i F w o c)MxMr- U) U) al}!1 I •osap Issapas �j�lllllt;� 0 d No.58705 ! i� .� E F f� jar �� �;AU A. LYNN MILLER, P.E. P.E.# 58705 1/8" ANNEALED GLASS uj z m N N � .075" Saflex CP With PET Core By 'Eastman Chemical Co.' w .090" Saflex Clear And Color Glass SBy 'Eastman Chemical Co.' .090" SentryGlase By 'Kuraray America, Inc.' .090" Trosifol PVB By 'Kuraray Ameica, Inc.' 1/8" ANNEALED GLASS SILICONE: GE 1200 DOW CORNING 791, 899, 983 & 995 O I / 14 E8 Er 1 W GLASS 'TYPE 'A' 5/16" OVERALL LAM. GLASS (L.M.I & S.M.I.) 1/8" ANNEALED GLASS 1/4" AIR SPACE 1/8" ANNEALED GLASS S .075" Saflex CP With PET Core By 'Eastman Chemical Co.' it .090" Saflex Clear And Color Glass g By 'Eastman Chemical Co.' ry w 090" SentryGlas® uj By 'Kuraray America, Inc.' .090" Trosifol PVB By 'Kuraray Ameica, Inc.' 1/8" ANNEALED GLASS SILICONE: GE 1200 DOW CORNING 791, 899, 983 & 995 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR DURASEAL BY 'QUANEX' OR SUPER SPACER BY 'QUANEX' GLASS TYPE 'Al' 0.70" OVERALL INSUL. LAM. GLASS (L.M.I & S.M.I.*) 1/8" HEAT STREN'D a O V4 W 1/8" HEAT STREN'D .075" Saflex CP With PET Core By 'Eastman Chemical Co.' w .090" Saflex Clear And Color Glass SBy 'Eastman Chemical Co.' 090" SentryGlas® � By 'Kuraray America, Inc.' .090" Trosifol PVB By 'Kuraray Ameica, Inc. 1/8" HEAT STREN'D GLASS SILICONE: GE 1200 DOW CORNING 791, 899, 983 & 995 GLASS TYPE 5/16" OVERALL LAM. GLASS (L.M.I & S.M.I.) 1 /4" AIR SPACE 1/8" HEAT STREN'D * (S.M.I.) IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING, THE EXTERIOR PLY OF GLASS TYPE 'Al' AND '131' MUST BE TEMPERED. z a O M W .075" Saflex CP With PET Core By 'Eastman Chemical Co.' w .090" Saflex Clear And Color Glass gBy 'Eastman Chemical Co.' w 090" SentryGlasO zBy 'Kuraray America, Inc.' .090" Trosifol PVB By 'Kuraray Ameica, Inc.' 1/8" HEAT STREN'D GLASS SILICONE: GE 1200 DOW CORNING 791, 899, 983 & 995 XL EDGE SPACER ST. STEEL BY 'CARDINAL' OR DURASEAL BY 'QUANEX' OR SUPER SPACER BY 'QUANEX' GLASS TYPE 'Ell' 0.70" OVERALL INSUL. LAM. GLASS (L.M.I & S.M.I.*) ADDED BACKBEDDING TYPES - JR - 07/07/20 0 ct N Y Q N O ?> 'Aaa ti o U) Na}DQ 00 z to �Ufl-N w aO Q Q M 0 `l o M Q Z l.L (D 5 0 UMDJQ Cn � UW� w Z 00 QWZ- -ON w-�� z HMO v ° !�) 2 ' = w rn u- Q (� M Uj v CC z to }aa4S W d)�o ca ow z W z z �31C)�� cv� ¢~o Q ~a N=Mo E � w 0 'd u- u. co r 0 - o z - rn w _o Mao 0ccoo211 w = a!}!1 •asap sarJaS �`�Ittl!ltlf!! fit" : -• r f No. 58705 0 A��a �41: A. LYNN1MILLE�, P.E. P.E.# 58705 1BY WOOD BUCK da tl. de ° d °' 6 (L 0 J 0 TYPICAL ANCHORS SEE ELEV. FOR SPACING n EDGEDIST. a4 d N -j r z 0 a a 0 O z z 11 W w a W U) S4 W i 1 i M9 . EDGE DIST. v• 1BY WOOD BUCK SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL c� W S z x .v N \ TYPICAL ANCHORS SEE ELEV. FOR SPACING METAL STRUCTURE Ow TYPICAL ANCHORS EDGE DIST. SEE ELEV. ►o- FOR SPACING m 0 N O 30 0 0 m3 d N 4F �' L7 2 3/8" MIN. M \\ \ 2 3/8" MIN. \ \ C-4 \`\ \ \ \ WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW. MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM AND TRANSFER THEM TO THE BUILDING STRUCTURE. FLANGE & FLANGE ADAPTOR FRAME if-----------------ll I MIAMI—DADE COUNTY APPROVED I I EDGE_ T I MULLION & MULLION ANCHORS I U)�i SEE SEPARATE NOA II \ EDGE I I I DIST j I L ----- ------------ a a d° e ° e. • •a d 4 EDGE DIST. f $ ° TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS SEE ELEV. FOR SPACING TYPICAL ANCHORS: SEE ELEV. FOR SPACING I/A" DIA. TAPCON BY 'ITW' (Fu=125 KSI, Fy=100 KSI) 1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI) 1 /4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI) INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 1-3/8" MIN. PENETRATION INTO WOOD THRU 1 BY BUCKS INTO CONC. OR BLOCKS 1-1 /4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1/4- MIN. EMBED INTO BLOCKS (JAMBS) DIRECTLY INTO CONCRETE OR BLOCKS 1-1/4- MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS) 1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS) #14 SMS OR SELF DRILLING SCREWS (Fu=74 KSI, Fy=57 KSI) INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO METAL STRUCTURES (HEAD/SILL/JAMBS) (3) THREADS MIN. PENETRATION BEYOND SUBSTRATE ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN. STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN-3 (STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED) TYPICAL EDGE DISTANCE INTO CONCRETE AND MASONRY = 2-1/2" MIN. INTO WOOD STRUCTURE = 1" MIN. INTO METAL STRUCTURE = 3/4" MIN. WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN. CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN. C-90 HOLLOW/FILLED BLOCK AT JAMBS Vm = 2000 PSI MIN. ADDED ANCHOR TYPE - JR - 07/07/20 O .N N Y Q N Cn •naa o � w � o O _J N � 0 � a oQ N zR z zp zLo O Z Q�v F- v � o 0 M � r 0 Z LLL � 3 Q UMDJQ 0) U U O � q Z 'ON ¢ z wo j� C9 SMQ rn LL 0 CL 2z z _ W �+ i Z C O J 0 'IT R O vj z H W U) Oa4s O Wow J fi CODO W �0 ¢U)o ¢ W 1— co f)= M O ova`'" r0 z r w W CW 0coLu Zo0 W W ¢¢o c� S co alp-L •osap sauas 0\4� 111! f/11/ xJ , f; LT std t rei r ° T /� Z441 a a TM F 't'xiE9fiittt�' A. LYNN MILLER, P.E. P.E.# 58705 IWb 1 /4" MAX. SHIM OTYPICAL ANCHORS SEE ELEV. 1 FOR SPACING n METAL STRUCTURE EDGE DIST. EXTERIOR D.L. OPG. 1/4" MAX* FLANGE & FLANGE ADAPTOR FRAME SHIMS TYPICAL ANCHORS SEE ELEV. FOR SPACING ' D,v o. D• •o ' EDGE DIST. 0 .1 BY P WOOD BUCKS I /A^ \IAV ..n ..... MIAMI—DADE COUNTY APPROVED MULLION 2S iE T. FLANGE ADAPTOR FRAME INTALLATION DETAILS SHOWN ON PAGES 4 AND 5 APPLY TO BOTH FLANGE FRAME AND FLANGE ADAPTOR FRAMES. 0 ot N Y Q o •Aaa O N 0 a}oo zo z Z O i O QOM w 8 Q Z ll. 5 Q "a U) U C.) O Z Q � 00 z 'ON L u 0 Z SMG rn LL 0 v (L�?2 ' Z) = w r i Z J � Lr) C O Rt O uj Z �+ O CO2 O C) W J w U) 0 Q IIII— f r cooLL9 W w con 0 ZQW�o 00 U) LLUma: alp-L 1 'asap Isapas �`���jlitflrl.'J d, `• 543 I No, 58705 'drrssltt�,` A. LYNN MILLER, P.E. P.E.# 58705 1BY WOOD BUCK do v do v a. a f� b a 0 J 0 9 J O 0 ~ o z F w �C w w U U A w..o , v EDGE DIST. - v. 1BY WOOD BUCK TYPICAL ANCHORS SEE ELEV. FOR SPACING EDGE' .DIST. d ° A a ° 'A SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL METAL STRUCTURE ow EDGE TYPICAL ANCHORS Y ¢ DIST. SEE ELEV. F- FOR SPACING m M V) 0 00 EDGE DIST. 3 m N 2 U W 2 `.L U D m • z x v v> \ U TYPICAL ANCHORS SEE ELEV. FOR SPACING 14F TYPICAL ANCHORS EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY INTO WOOD, CONCRETE OR METAL STRUCTURES WITHOUT THE NEED OF A WOOD BUCK. 2 3/8" MIN. 2 3/8" MIN. —� \ \\♦ \ \ WHEN USED THE MIN. WOOD BUCK DEPTH SHALL BE 2%". THE USE OF DEEPER OR BEVELED WOODBUCKS IS PERMITTED. EDGE DIST. TYPICAL ANCHORS SEE ELEV. FOR SPACING •d u • A ° ,c9 ° . a v d \ Z• ', EQUAL LEG FRAME -------------------- j I MIAMI—DADE COUNTY APPROVED I j I I MULLION & MULLION ANCHORS i I �j SEE SEPARATE NOA II I I II EDGE DIST. f;—------ II ------ -------- I __J t TYPICAL ANCHORS SEE ELEV. MIAMI—DADE COUNTY FOR SPACING APPROVED M111I ION o a .1 !� . da a' A, I ITYPICAL ANCHORS SEE ELEV. FOR SPACING Al oN Y Q N O ?) 'Aga ti o � N JLLJ a) �? 0 O a}DQ z z Lo }U' N O W o Q0M xe oZLLm 5 Q "'o U) uiUWo U z Q00 �Zv 'IN W OWS > U SMa rn LL 0 v adz°' _ w y U C O Z J U CO m C ! uj VJ In ¢ OfU) z J }aa4S vs W U 0 O U W 3 o�� J I— LLl W z C U O (D z CL U ccl) co - U o co Z w J Q o 0 — Of �.Lu �(, Uc')X w o X aµ!1 -isap sauas i I r s f _ aka (.° 12 - �r fAv�ti l�lit4titl. A. LYNN MILLER, P.E. P.E.# 58705 ILLUSTRATIVE DTLS. ONLY EXT. OR INT. FINISHES NOT BY CGI HOUSE WRAP NOT BY CGI A2 , ES 6 IL 0 J O E„ 1 W C 2 to Z w w � V) N s4 I HOUSE WRAP NOT BY CGI TYPICAL ANCHORS SEE ELEV. FOR SPACING z C a• TYPICAL ANCHORS: SEE ELEV. FOR SPACING 8 SMS (Fu=74 KSI, Fy=57 KSI) E1 INTO 2BY WOOD BUCKS OR WOOD STRUCTURES 'J BACKBED 1-1/4" MIN. PENETRATION INTO WOOD ((A I CAULKING SWEEP LOCK OPTIONAL TO EGRESS LOCK AT SILL TYPICAL ANCHORS SEE ELEV. FOR SPACING BACKBED CAULKING Y U m WOOD STRUCTURE 1/4" MAX. NOT BY CGI W e. FIN FRAME Rllrk wrlrur 1/4" MAX. C O N N Y Q o •Aab o O W O ¢O a}o4 z O W C7 N Q 0 co O Xe QZLJL� a Q ""o (0 w Lu w z <t�zv ON °- owe U 9M4 wo>�r z :D 2 w rn ILL 0 y U C O Z —I �C O uj z }aa4S y G w of (q W 0 O owLij J W z z 1 Q p � t�i r' F¢- U) 000 cD w W - o _z�QM ��-j- 0 r w — LL = U) U c) S `✓ al}il asap Isaliagi L \�����i S gyp, .+ g f °Jf fi��.%•�� No. 587€ 5 r �' OR lo ! OF 1 N0 4 t' A. LYNN MILLER, P.E. P.E.# 58705 ITEM PART # QUANTITY DESCRIPTION MATERIAL MANF./SUPPLIER/REMARKS E1 CGI-100 1 FRAME HEAD 6063-T6 - E2 CGI-101 1 FRAME SILL 6063-T6 - E3 CGI-102 2 FRAME JAMB 6063-T6 - E4 CGI-103 1 MEETING RAIL 6063-T6 - E5 CGI-104 1 LOCK RAIL 6063-T6 - E6 CGI-105 1 HANDLE RAIL 6063-T6 - E7 CGI-106 2 SASH RAIL 6063-T6 - E8 CGI-107 AS READ. 5/16" GLAZING BEAD 6063-T5 - E9 CGI-108 AS READ. 0.700" GLAZING BEAD 6063-T5 - E10 CGI-109 AS READ. FRONT FLANGE ADAPTOR 6063-T6 - E11 CGI-110 AS READ. NAIL FIN ADAPTOR 6063-T5 - E12 CGI-135 1 FLANGE FRAME HEAD 6063-T6 - E13 CGI-136 2 FLANGE FRAME JAMB 6063-T6 - E14 CGI-137 1 FLANGE FRAME SILL 6063-T6 - E17 CGI-605 OPTIONAL SCREEN FRAME 6063-T5 - M1 CGI-382V AS READ. GLAZING BULB VINYL (DUROMETER 75-80 SHORE A) PVC - M2 CGI-111 OPTIONAL SCREW COVER PVC PROTOTYPE OR EQUIV. M3 CGI-112 AS REQD. EQUAL LEG COVER/SHIM, 3" LONG AT ANCHOR LOCATIONS PVC - M9 SUPER BOOST 2/ WDW. SPIRAL BALANCE - BSI OR EQUIV. M10 - 2/ WDW. BLOCK/TACKLE BALANCE - BSI OR EQUIV. M11 W23201NG AS REQD. PILE WITH CENTER FIN WOOL ULTRAFAB OR EQUIV. M12 CGI-129 1/ WDW. EGRESS LOCK ALUM. SULLIVAN M13 CGI-131 2/ WDW. HANDLE RAIL END CAP NYLON M&M M14 E26018WN - D BULB-T SLOT PVC ULTRAFAB OR EQUIV. M15 CGI-133 4/ WDW. SASH GUIDE(SPIRAL BALANCE) NYLON M&M M16 CGI-130 2/ WDW. SASH TOP GUIDE(SPIRAL BALANCE) NYLON M&M M17 A30730401-32 1/ WDW. CAM LOCK ZINC TRUTH OR EQUIV. M18 CGI-132 2/ WDW. SASH STOP, 2" LONG PVC PROTOTYPE OR EQUIV. M19 - 2/ LITE SETTING BLOCK EPDM DUROMETER 85±5 SHORE A M20 CGI-125 2/ WDW. SASH CAM (B/T BALANCE) NYLON M&M M21 - 2/ WDW. B/T BALANCE TAKE OUT CLIP - BSI OR EQUIV. M22 146-6 2/ WDW. WEEP COVER NYLON AMESBURY OR EQUN M23 CGI-134 - SILL SPACER PVC PROTOTYPE OR EQUIV. S2 - 2 OR 3/CORNER # 10 X 1 1/4" LG. PHL. PH. SMS. ST/ST. ASSEMBLY SCREW - - S4 - 4/ WDW. # 8 X 1/2" PH. SMS. ST/ST BALANCE BRACKET SCREW - - S5 - 2/ WDW. # 8 X 1" LG. FH. SMS. ST/ST. SPIRAL B. ASSEMBLY - - S6 - 2/ LOCK # 6 X 1/2" LG. FH. SMS. ® CGI-133 & CAM LOCK - - c 0 N Y Q 04 O Ui 'naa w o O () rn rn 0 a}oQ �> C14 Z O W .0 N O QO�r -Zt-(D Z5 o un+n0 cn wUwo Z < > > > 'ON z 4 w^ jr 09Mo v adz°' :D = w rn LL 0 •. i Z c o J � 00 o r to G ¢ _Z (n m }aa4S MA 0J � o ow Q W w o Z Q W d C �= M O. E� 3 N J� C) c- QQc G W � LL u (n Z W Q J O �w _ J Uco< m'n W m = m aµil •asap sar�aS .tl�?Sltttai� l o. 5870 NY L V fffi''iili}'{il\`;,.' A. LYNN MILLER, P.E. P.E.# 58705 2.505 2.505 �.065 S2 S2 06511 1.745 .811 811 1.245 1.550 1.680 .745 .06 TYP. .745 .065 TYP. .050L1.015 7395 i 1.015 E12 FLANGE FRAME HEAD E� FLUSH FRAME HEAD E11 NAIL FIN ADAPTER 1.583 1.583 1.007 .745 .065 .065 TYP. TYP. .065 2.113 TYP. , 3.675 1 429In 065 3.175 1 429 t A 3.175 1.368 1.015 VENT TOP CORNER i 1.000 .500 500 �� 2.505 1.220 E4 MEETING RAIL FRAME TOP CORNER 2.505 E14 FLANGE FRAME SILL E2 FLUSH FRAME SILL 1.220 1.043 .500 1.301 j�-1 301 1.788 065 S2 0654E.TO6. .065 .065 NP' TYP. I 1.015 Imo- 2.440 1•015 LL32 2.440 � 1.015 E5 LOCK RAIL FRAME BOTTOM CORNER VENT BOTTOM CORNER .745 2.846 I .745 IF� 2.195 E13 2.346 E3 FLANGE FRAME JAMB FLUSH FRAME JAMB 1.892 65 1.043FM.jO YP. T .12-�{ 70� 5 FR 050 TYP. 7K+.050 TYP. 1.015 1 S2 �i .864 .864 Fes- E6 HAND RAIL Es E9 5/16" GLAZING BEAD .700" GLAZING BEAD 1.395 1.395 i F i��.180 vil 1.449 .293 .7451.450 665 .675 .180 .050 1- .060 �1-1.413A� �- 550 050 .065 M3 FLUSH FRAME COVER M19 SCREW E7 E10 COVER SASH RAIL FLANGE ADAPTOR c 0 Q N Y Q N o •Aab LLJ ti o N OQ, Q O a}op t Z Z Lo O J C7 N -' o Q o V'7 J C r � Qz LLL.. � -0 Q IIMDJp U) w=w`- w � o Z_ LLJ 'ON aow^ wr>� C0 pM0 a-Z°' z 2 w rn W 0 w O uj Z W o 0 O W W = Q�0 Q U) =_ �=c) 0 � O W V) LL o CO W Z C) - O �coQo Ucri2� W X0 W = 911i1 asap sauaS 1 No- 58705 2-TF � A. LYNN MILLER, P.E. P.E.# 58705