HomeMy WebLinkAboutAPPROVED Single HungMIAMI•DADE MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/building
CGI Windows and Doors, Inc.
3780 W 104t' Street
Hialeah, FL 33018
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform
in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product
or material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code,
including the High Velocity Hurricane Zone.
DESCRIPTION: Series "Sentinel 110" Aluminum Single Hung Window — L.M.I.
APPROVAL DOCUMENT: Drawing No. SH110-LM-NOA, titled "Series 110 Alum. Single Hung Window
(LM)", sheets 1 through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision
stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control
Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state,
model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise
noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises and renews NOA# 17-1018.08 and consists of this page 1 and evidence pages E-1, E-2,
E-3, E-4 and E-5, as well as approval document mentioned above.
The submitted documentation was reviewed by Manuel Perez, P.E.
NOA No. 20-0722.09
MIAMI•DADE COUNTY Expiration Date: September 22, 2025
• ' Approval Date: September 10, 2020
9/1/20 Page 1
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's
A. DRAWINGS
1. Manufacturer's die drawings and sections.
(Submitted under NOA No. 10-0510. 11)
2. Drawing No W10-03, titled "Series Sentinel 110 Alum S.H. Wdw. (L.M.I./S.M.I.)",
sheets 1 through 9 of 9, dated 02/02/10, with revision D dated 09/29/17, prepared by
Al-Farooq Corporation, signed and sealed by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
B. TESTS
1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7500 PVC fixed
window, to qualify DuPont "Butacite" PVB interlayer, Duraseal® and Super Spacer(&
insulating glass spacer, prepared by Certified Test Laboratories, Test Report No.
CTLA-3056 WA, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 7400 PVC project
out window, to qualify DuPont `Butacite" PVB interlayer, Duraseal(V and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA-3056 WB, dated 03/03/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
3. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of a series 238 aluminum
fixed window, to qualify DuPont `Butacite" PVB interlayer, Duraseal® and Super
Spacer® insulating glass spacer, prepared by Certified Test Laboratories, Test Report
No. CTLA-3056 WC, dated 04/16/15, signed and sealed by Ramesh C. Patel, P.E.
(Submitted under NOA No.15-0512.09)
Manuel Perez, P.E.
Product Control Ex r
NOA No. 20 0722.09
Expiration Date: September 2
Approval Date: September 10, 2020
E -l
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED)
B. TESTS (CONTINUED)
4. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 2411.3.2.1, TAS 202-94
along with marked -up drawings and installation diagram of a series "Sentinel"
aluminum single hung window, prepared by Hurricane Test Laboratory, LLC, Test
Report No. HTL-0080-0101-10, dated 02/03/10, signed and sealed by Vinu J.
Abraham, P.E.
(Submitted under NOA No. 10-0510.11)
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 611
Edition (2017), dated 09/29/17, prepared by Al-Farooq Corporation, signed and
sealed by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
2. Glazing complies with ASTM E1300-09
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER).
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 14-0916.11 issued to Kuraray America, Inc. for their
"SentryGlas® (Clear and White) Glass Interlayers" dated 06/25/15, expiring on
07/04/18.
2. Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/19/17,
expiring on 07/08/19.
3. Notice of Acceptance No. 17-0712.03 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 09/07/17, expiring on 12/11/18.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
Manuel Perez, P.E.
Product Control Ex . er
.1 NOA No. 20 0722.09
Expiration Date: September , 2
Approval Date: September 10, 2020
E-2
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's (CONTINUED)
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 5" Edition (2014), and of no
financial interest, dated 08/26/14, issued by Al-Farooq Corporation, signed and sealed
by Javad Ahmad, P.E.
(Submitted under NOA No.17-1018.08)
2. Laboratory compliance letter for Test Report No. HTL-0080-0101-10, issued by
Hurricane Test Laboratory, LLC, dated February 03, 2010, signed and sealed by Vinu
J. Abraham, P.E.
(Submitted under NOA No. 10-0510. 11)
3. Test Proposal for the qualification of Butacite® PVB glass interlayer by DuPont as
well as Duraseal® and Super Spacer® Standard warm -edge flexible insulating glass
spacers, dated December 16, 2014, issued by RER, Product Control Section, signed by
Jaime Gascon, Supervisor.
(Submitted under NOA No. 15-0512. 10)
G. OTHERS
1. Notice of Acceptance No. 15-0512.10, issued to CGI Windows & Doors for their Series
"Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on 08/06/15 and
expiring on 09/22/20.
Manuel Pere
Product Control Ex
f NOA No. NO
Expiration Date: September Ik
Approval Date: September 1
E-3
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No SH110-LM-NOA, titled "Series 110 Alum Single Hung Window (LM)",
sheets I through 9 of 9, dated 07/02/20, with revision A dated 07/07/20, prepared by
manufacturer, signed and sealed by Anthony Lynn Miller, P.E.
B. TESTS
1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per ASTM F588 and TAS 202-94
along with marked -up drawings and installation diagram of all PGT Industries, Inc.
CGI Windows and Doors, Inc., representative units listed below and tested to qualify
Dowsil 791 and Dowsil 983 silicones, per Proposal #19-1155TP, prepared by
Fenestration Testing Laboratory, Inc., Test Reports No.:
PGT Industries, Inc. test specimens:
FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14
FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal)
FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal)
FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and
FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal)
all dated 07/13/20 and signed and sealed by Idalmis Ortega, P.E.
CGI Windows and Doors Inc. test specimens:
FTL-20-2108.1, CGI SH360 Aluminum Single Hung Window (unit I in proposal)
FTL-20-2108.2, CGI CA238 Alum. Outswing Casement Window (unit 2 in proposal)
FTL-20-2108.3, CGI SGD560 Aluminum Sliding Glass Door (unit 3 in proposal)
FTL-20-2108.4, CGI PW410 Aluminum Fixed Window (unit 4 in proposal) and
FTL-20-2108.5, CGI SH360 Aluminum Single Hung Window (unit 5 in proposal)
all dated 08/24/20 and signed and sealed by Idalmis Ortega, RE
C. CALCULATIONS
1. Anchor verification calculations and structural analysis, complying with FBC 711
Edition (2020), dated 07/11/20, prepared by manufacturer, signed and sealed by
Anthony Lynn Miller, P.E.
Manuel Perez, P
Product Control Ex
J NOA No. 0722
Expiration Date: September 2,2.
Approval Date: September 10, 2(
E-4
CGI Windows and Doors, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. NEW EVIDENCE SUBMITTED (CONTINUED)
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 18-0725.11 issued to Kuraray America, Inc. for their
"Kuraray SentryGlas® XtraTM (SGXTM) Clear Glass Interlayer" dated 05/23/19,
expiring on 05/23/24.
2. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. for their
"Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 05/09/19,
expiring on 07/08/24.
3. Notice of Acceptance No. 18-0301.06 issued to Eastman Chemical Company (MA)
for their "Saflex CP - Saflex and Saflex HP Composite Glass Interlayers with PET
Core" dated 05/17/18, expiring on 12/11/23.
4. Notice of Acceptance No. 17-0712.05 issued to Eastman Chemical Company (MA)
for their "Saflex Clear and Color Glass Interlayers" dated 09/07/17, expiring on
05/21/21.
F. STATEMENTS
1. Statement letter of conformance, complying with FBC 6t' Edition (2017) and the
FBC 7t' Edition (2020), dated July 16, 2020, issued by manufacturer, signed and
sealed by Anthony Lynn Miller, P.E.
2. Statement letter of no financial interest, dated July 16, 2020, issued by manufacturer,
signed and sealed by Anthony Lynn Miller, P.E.
3. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
4. Notification of Successor Engineer for manufacturer's NOA document per Section
61G15-27.001 of the Florida Administrative Code, notifying original engineer that
the successor engineer is assuming full professional and legal responsibility for all
engineering documents pertaining to this NOA, dated July 16, 2020, signed and sealed
by Anthony Lynn Miller, P.E.
5. Proposal No. 19-1155 TP issued by the Product Control Section, dated January 10,
2020, signed by Ishaq Chanda, P.E.
G. OTHERS
1. Notice of Acceptance No. 17-1018.08, issued to CGI Windows & Doors for their
Series "Sentinel 110" Aluminum Single Hung Window - L.M.I., approved on
12/21/17 and expiring on 09/22/20. t
Manuel Perez, P.E:
Product Control Ex r
J NONo. 20 0722.09
Expiration Date: September , 2
Approval Date: September 10, 2020
E-5
r,x 1 /A"
R9 1 /R"
2
6" MAX.
HEAD/SILL
CORNERS
w
M U- _
M v
O
zw
\w
M = to
1- n O
M W M J
> o
FLANGE WIDTH
47 7/16"
D.L.O. (FIX. LITE)
20 9/16"
MAX.
A HEAD/SILL
II It
II II
II II
11 �l II
II II
11 It
II % II
II II
II II
C II II
j l
FALSE MUNTINS
`(SURFACE APPLIED)
OPTIONAL 5 1 /2" MAX.
/ HEAD/SILL
CORNERS
w
x J
J
M _
M O
of
F-
0
co
x
�n
w
=
rY
U
-
D
m
Z
-,W
to_
�>
n v
N cn
M Z
M O E1 J
>
0
M � Q
In
m=
w
47 7/16" a w
to o
D.L.O. (VENT)
50 1/4"
VENT WIDTH
FLANGE & FLANGE ADAPTOR FRAME
BUCK WIDTH
47 7/16"
D.L.O. (FIX. LITE)
20 9/16"
MAX.
HEAD/SILL
Al
V.
II II
II II
�
II II
II II
II II
B II 1�
it It
n % n
II II
II II
II 11
C l
SERIES SENTINEL 110 ALUMINUM SINGLE HUNG WINDOW
LARGE & SMALL MISSILE (LM & SM)
DESIGN LOAD RATINGS FOR THESE WINDOWS TO BE AS PER CHARTS SHOWN ON SHEET 2.
FALSE MUNTINS
(SURFACE APPLIED)
OPTIONAL
5 1/2" MAX.
HEAD/SILL
x
w
J
D2
M
�
M
O
J
F
�
U
w
Y
U
D
m
co
ED
E2
MLd
= My
N fn M Z M O
\ X m -'
>
to
FALSE MUNTINS
47 7/16" Q 'z (SURFACE APPLIED)
D.L.O. (VENT) \ ''30 OPTIONAL
In
50 1/4-
VENT WIDTH
EQUAL LEG FRAME
APPROVAL APPLIES TO SINGLE UNITS OR SIDE BY SIDE COMBINATIONS OF S.H./S.H. OR SINGLE HUNG WINDOW WITH OTHER
MIAMI-DADE COUNTY APPROVED WINDOWS USING MIAMI-DADE COUNTY APPROVED MULLIONS IN BETWEEN. LOWER DESIGN
PRESSURE FROM WINDOWS OR MULLION APPROVAL WILL APPLY TO ENTIRE SYSTEM.
THIS PRODUCT HAS BEEN DESIGNED AND TESTED TO COMPLY WITH THE REQUIREMENTS OF THE 2017 (6TH EDITION) AND 2020 (7TH
EDITION) FLORIDA BUILDING CODE INCLUDING HIGH VELOCITY HURRICANE ZONE (HVHZ).
1BY OR 2BY WOOD BUCKS & BUCK FASTENERS BY OTHERS, MUST BE DESIGNED AND INSTALLED ADEQUATELY TO TRANSFER APPLIED
PRODUCT LOADS TO THE BUILDING STRUCTURE.
ANCHORS SHALL BE CORROSION RESISTANT, SPACED AS SHOWN ON DETAILS AND INSTALLED PER MANUF'S INSTRUCTIONS. SPECIFIED
EMBEDMENT TO BASED MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.
A LOAD DURATION INCREASE IS USED IN DESIGN OF ANCHORS INTO WOOD ONLY.
ALL SHIMS TO BE HIGH IMPACT, NON-METALLIC AND NON -COMPRESSIBLE.
MATERIALS INCLUDING BUT NOT LIMITED TO STEEL/METAL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL
MEET THE REQUIREMENTS OF THE 2017/2020 FLORIDA BLDG. CODE & ADOPTED STANDARDS.
THIS PRODUCT APPROVAL IS GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT, i.e. LIFE SAFETY OF THIS
PRODUCT, ADEQUACY OF STRUCTURE RECEIVING THIS PRODUCT AND SEALING AROUND OPENING FOR WATER INFILTRATION RESISTANCE, ETC.
CONDITIONS NOT SHOWN IN THIS DRAWING ARE TO BE ANALYZED SEPARATELY, AND TO BE REVIEWED BY BUILDING OFFICIAL.
BUCK WIDTH
47 7/16"
D.L.O. (FIX. LITE)
20 9/16"
MAX.
A2 HEAD/SILL
O
W
J
o
\Q m Q�
g m�
47 7/16" N m z
D.L.O. (VENT) \ 7)o
50 1/4"
VENT WIDTH
FIN FRAME
�c *CENTER ANCHOR REQUIRED WHEN
SPACING EXCEEDS 20 9/16"
LAMINATED GLASS
INSULATING LAM. GLASS
SMALL MISSILE IMPACT
LARGE MISSILE IMPACT
REVISED FOR 2020 FBC,
ADDED ANCHOR TYPE,
•O BACKBEDDING &
t REFORMATTED -JR-
rr
07/07/20
O
(v
Y
Q
N
C)
•naa
W
O
O
J w �
�
O
a}DQ
*Cl
U)
Z
J> N O
w
o
Q0v
J J O
a
QZ LL
Q
UA DJQ
cl)
w=w- w
z
� 0 0 a
CO
>
>
°N
wIw-
oW�
w�>
SMQ
rn
IL
p
adz°'
z
=
w
U
Z
J
U
C O
c
z
}aa4s
.�.
v) 1= m
to
u+ 0
0 O W
w
R= Z�o
Q
U)
Q= ujOco
E3:
O
z
O
z
w
a�LL°
Z �
w
cn
O
-
_j�
0UMSM
5
��Ju,
R
U)
J
W
2
(A
alpi
•osaQ
sauas
t111d ,rlp
No53705
C1
'gyp "IATE � `F �
//// /c)N 1y
/jt{ilil\11
A. LYNN MILLER, P.E.
P.E.# 58705
EQUAL IMS WINDOWS
DESIGN LOAD CAPACITY - PSF
FLANGE DIMS.
BUCK DIMS.
GLASS TYPES 'A'&'A1'
GLASS TYPES 'B'&'Bl'
WIDTH
HEIGHT
WIDTH
HEIGHT
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
19-1/8"
26-1/2"
37"
49"
53-1/8"
26"
18-1/8"
25-1/2"
36"
48"
52-1/8"
25"
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
19-1 /8"
26-1/2"
37"
49"
53-1/8"
38-3/8"
18-1 /8"
25-1/2"
36"
48"
52-1/8"
37-3/8"
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
19-1/8"
26-1/2"
37"
49"
53-1/8"
50-5/8"
18-1/8"
25-1/2"
36"
48"
52-1/8"
49-5/8"
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
19-1/8"
26-1/2"
37"
49"
53-1/13"
63"
1
18-1/8"
25-1/2"
36"
Q.
52-1/8"
62"
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
19-1/8"
26-1/2"
37"
49"
53-1/8"
76"
18-1/8"
25-1/2"
36"
48"
52-1/8"
75'
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
19-1/8"
26-1/2"
37"
46-1/2"
85"
18-1/8"
25-1/2"
36"
45-1/2"
84"
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
75.0
75.0
80.0
80.0
WinTw
EQUAL LITES
NOTE:
GLASS CAPACITIES ON THIS SHEET ARE BASED ON ASTM
E1300-09 (3 SEC. GUSTS) AND FLORIDA BUILDING COMMISSION
DECLARATORY STATEMENT DCA05-DEC-219.
UNEQUAL LITES WINDOWS
DESIGN LOAD CAPACITY - PSF
FLANGE DIMS.
BUCK DIMS.
MA%TOP LITE
GLASS TYPES 'A'&'Al'
GLASS TYPES 'B'&'Bl'
WIDTH
HEIGHT
WIDTH
HEIGHT
'A' DIM.
EXT.(+)
INT.(-)
EXT.(+)
INT.(-)
53-1/8"
76"
52-1/8"
75"
36-1/4"
75.0
75.0
80.0
80.0
49"
79
48"
78"
39-1/4"
75.0
75.0
80.0
80.0
26-1/2"
31"
33"
37"
43"
85"
1
25-1/2"
30"
32"
36"
1 42"
84"
70-5/8"
75.0
75.0
80.0
00.0
63-5/8"
75.0
75.0
80.0
80.0
60"
75.0
75.0
80.0
80.0
53-1/2"
75.0
75.0
80.0
80.0
45-1/4"
75.0
75.0
1 80.0
80.0
Y TYP.
UNEQUAL LITES (ORIEL TYPE)
TYP.
BUCK DIMS
F
z
w
FLANGE FRAME
FLANGE DIMS
cli
BUCK DIMS g
0 p
W
Y
g MW
� m J
EQUAL LEG FRAME
BUCK DIMS
FIN FRAME
BUCK DIMS
FLANGE ADAPTOR FRAME
UNEQUAL LITES (ORIEL TYPE)
c
0
cc
o
N
Y
Q
N
O
naa
w rn
CDO
N
0
a}np
Z
Ln
O
Z
W
JC7N
o
<( p v
Qz U- to
0
UMDJp
U)
w
Z
U V o
00
ON
< I-
a uJ
��>�
Ur
UMp
(L
z
=
W
rn
W
y U
C O z
J
U
N
tC o U�
Z
}aa4S
n oc
U)
W p
0
O W
W
m' Q p
Q
Q
a,E cn=Mo
O
W
I
o §
wZ
o-iw
i
F
w
o
c)MxMr-
U)
U)
al}!1 I
•osap Issapas
�j�lllllt;�
0 d
No.58705 !
i� .�
E F
f� jar �� �;AU
A. LYNN MILLER, P.E.
P.E.# 58705
1/8" ANNEALED GLASS
uj
z
m
N
N �
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
w .090" Saflex Clear And Color Glass
SBy 'Eastman Chemical Co.'
.090" SentryGlase
By 'Kuraray America, Inc.'
.090" Trosifol PVB
By 'Kuraray Ameica, Inc.'
1/8" ANNEALED GLASS
SILICONE:
GE 1200
DOW CORNING 791,
899, 983 & 995
O I /
14 E8
Er 1
W GLASS 'TYPE 'A'
5/16" OVERALL LAM. GLASS
(L.M.I & S.M.I.)
1/8" ANNEALED GLASS
1/4" AIR SPACE
1/8" ANNEALED GLASS
S
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
it .090" Saflex Clear And Color Glass
g By 'Eastman Chemical Co.'
ry w 090" SentryGlas®
uj By 'Kuraray America, Inc.'
.090" Trosifol PVB
By 'Kuraray Ameica, Inc.'
1/8" ANNEALED GLASS
SILICONE:
GE 1200
DOW CORNING 791,
899, 983 & 995
XL EDGE SPACER
ST. STEEL BY 'CARDINAL'
OR
DURASEAL BY 'QUANEX'
OR
SUPER SPACER BY 'QUANEX'
GLASS TYPE 'Al'
0.70" OVERALL INSUL. LAM. GLASS
(L.M.I & S.M.I.*)
1/8" HEAT STREN'D
a
O
V4
W
1/8" HEAT STREN'D
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
w .090" Saflex Clear And Color Glass
SBy 'Eastman Chemical Co.'
090" SentryGlas®
� By 'Kuraray America, Inc.'
.090" Trosifol PVB
By 'Kuraray Ameica, Inc.
1/8" HEAT STREN'D GLASS
SILICONE:
GE 1200
DOW CORNING 791,
899, 983 & 995
GLASS TYPE
5/16" OVERALL LAM. GLASS
(L.M.I & S.M.I.)
1 /4" AIR SPACE
1/8" HEAT STREN'D
* (S.M.I.)
IN ORDER TO QUALIFY FOR SMALL MISSILE IMPACT RATING, THE EXTERIOR PLY OF GLASS TYPE 'Al' AND '131' MUST BE TEMPERED.
z
a
O
M
W
.075" Saflex CP With PET Core
By 'Eastman Chemical Co.'
w .090" Saflex Clear And Color Glass
gBy 'Eastman Chemical Co.'
w 090" SentryGlasO
zBy 'Kuraray America, Inc.'
.090" Trosifol PVB
By 'Kuraray Ameica, Inc.'
1/8" HEAT STREN'D GLASS
SILICONE:
GE 1200
DOW CORNING 791,
899, 983 & 995
XL EDGE SPACER
ST. STEEL BY 'CARDINAL'
OR
DURASEAL BY 'QUANEX'
OR
SUPER SPACER BY 'QUANEX'
GLASS TYPE 'Ell'
0.70" OVERALL INSUL. LAM. GLASS
(L.M.I & S.M.I.*)
ADDED BACKBEDDING
TYPES - JR - 07/07/20
0
ct
N
Y
Q
N
O
?>
'Aaa
ti
o
U)
Na}DQ
00
z
to �Ufl-N
w
aO
Q Q M
0
`l
o
M
Q Z l.L (D 5
0
UMDJQ
Cn
� UW� w
Z
00
QWZ-
-ON
w-��
z
HMO
v
° !�) 2 '
=
w
rn
u-
Q
(�
M
Uj
v CC
z
to
}aa4S
W
d)�o ca
ow
z
W
z
z
�31C)��
cv� ¢~o
Q
~a
N=Mo
E �
w
0 'd u- u.
co
r
0
-
o
z - rn
w
_o
Mao
0ccoo211
w
=
a!}!1
•asap
sarJaS
�`�Ittl!ltlf!!
fit" : -•
r f No. 58705
0 A��a �41:
A. LYNN1MILLE�, P.E.
P.E.# 58705
1BY
WOOD BUCK
da tl. de
° d °'
6
(L
0
J
0
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
n EDGEDIST.
a4
d N
-j
r
z
0
a
a
0
O
z
z
11
W
w
a
W
U)
S4
W
i
1
i
M9 .
EDGE
DIST.
v• 1BY
WOOD BUCK
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
c�
W
S
z
x
.v
N
\
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
METAL
STRUCTURE
Ow
TYPICAL ANCHORS
EDGE
DIST. SEE ELEV.
►o-
FOR SPACING
m
0 N
O
30
0
0
m3
d
N
4F
�' L7
2 3/8" MIN.
M \\
\
2 3/8" MIN.
\
\
C-4 \`\
\
\
\
WHEN USED THE MIN. WOOD BUCK
DEPTH SHALL BE 2%". THE USE OF
DEEPER OR BEVELED WOODBUCKS IS
PERMITTED.
WOOD BUCKS AND METAL STRUCTURE NOT BY CGI WDW.
MUST SUSTAIN LOADS IMPOSED BY GLAZING SYSTEM
AND TRANSFER THEM TO THE BUILDING STRUCTURE.
FLANGE & FLANGE ADAPTOR FRAME
if-----------------ll
I MIAMI—DADE COUNTY APPROVED I I
EDGE_ T I MULLION & MULLION ANCHORS I
U)�i SEE SEPARATE NOA II
\ EDGE I I
I DIST j
I L ----- ------------
a a
d° e
° e.
• •a d
4 EDGE DIST.
f $ ° TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
I/A" DIA. TAPCON BY 'ITW' (Fu=125 KSI, Fy=100 KSI)
1/4" DIA. ULTRACON BY 'ELCO' (Fu=177 KSI, Fy=155 KSI)
1 /4" DIA. ULTRACON+ BY 'DEWALT' (Fu=164 KSI, Fy=148 KSI)
INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
1-3/8" MIN. PENETRATION INTO WOOD
THRU 1 BY BUCKS INTO CONC. OR BLOCKS
1-1 /4" MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1/4- MIN. EMBED INTO BLOCKS (JAMBS)
DIRECTLY INTO CONCRETE OR BLOCKS
1-1/4- MIN. EMBED INTO CONCRETE (HEAD/SILL/JAMBS)
1-1 /4" MIN. EMBED INTO BLOCKS (JAMBS)
#14 SMS OR SELF DRILLING SCREWS (Fu=74 KSI, Fy=57 KSI)
INTO MIAMI-DADE COUNTY APPROVED MULLIONS OR INTO
METAL STRUCTURES (HEAD/SILL/JAMBS)
(3) THREADS MIN. PENETRATION BEYOND SUBSTRATE
ALUMINUM : 1/8" THK. MIN. (6063-T5 MIN.
STEEL : 1/8" THK. MIN. (Fy = 36 KSI MIN-3
(STEEL IN CONTACT WITH ALUMINUM TO BE PLATED OR PAINTED)
TYPICAL EDGE DISTANCE
INTO CONCRETE AND MASONRY = 2-1/2" MIN.
INTO WOOD STRUCTURE = 1" MIN.
INTO METAL STRUCTURE = 3/4" MIN.
WOOD AT HEAD, SILL OR JAMBS SG=0.55 MIN.
CONCRETE AT HEAD, SILL OR JAMBS Vc = 3000 PSI MIN.
C-90 HOLLOW/FILLED BLOCK AT JAMBS Vm = 2000 PSI MIN.
ADDED ANCHOR TYPE
- JR - 07/07/20
O
.N
N
Y
Q
N
Cn
•naa
o
�
w �
o
O
_J N
�
0
�
a oQ
N
zR
z
zp zLo O
Z
Q�v F-
v
�
o
0 M �
r
0 Z LLL � 3
Q
UMDJQ
0)
U U O
� q
Z
'ON
¢ z
wo j�
C9
SMQ
rn
LL
0
CL 2z
z
_
W
�+ i Z
C O
J
0
'IT
R O vj
z
H W
U)
Oa4s
O
Wow
J
fi CODO
W
�0 ¢U)o
¢
W
1—
co
f)= M O
ova`'"
r0
z
r
w
W
CW
0coLu
Zo0
W
W
¢¢o
c� S
co
alp-L
•osap
sauas
0\4� 111! f/11/
xJ , f;
LT std t rei
r °
T /� Z441
a
a TM F
't'xiE9fiittt�'
A. LYNN MILLER, P.E.
P.E.# 58705
IWb
1 /4" MAX.
SHIM
OTYPICAL ANCHORS
SEE ELEV. 1
FOR SPACING n
METAL
STRUCTURE
EDGE DIST.
EXTERIOR
D.L. OPG.
1/4" MAX*
FLANGE & FLANGE ADAPTOR FRAME
SHIMS
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
' D,v
o.
D•
•o '
EDGE DIST.
0
.1 BY
P
WOOD BUCKS
I /A^ \IAV ..n .....
MIAMI—DADE COUNTY
APPROVED MULLION
2S
iE
T.
FLANGE ADAPTOR FRAME
INTALLATION DETAILS SHOWN ON PAGES 4
AND 5 APPLY TO BOTH FLANGE FRAME
AND FLANGE ADAPTOR FRAMES.
0
ot
N
Y
Q
o
•Aaa
O
N
0
a}oo
zo z
Z
O
i
O
QOM w
8
Q Z ll. 5
Q
"a
U)
U C.) O
Z
Q � 00
z
'ON
L u 0
Z
SMG
rn
LL
0
v
(L�?2 '
Z)
=
w
r i Z
J
�
Lr)
C O
Rt O uj
Z
�+ O
CO2 O C) W
J
w
U) 0
Q
IIII—
f
r
cooLL9
W
w
con
0
ZQW�o
00
U)
LLUma:
alp-L 1
'asap Isapas
�`���jlitflrl.'J
d,
`• 543 I
No, 58705
'drrssltt�,`
A. LYNN MILLER, P.E.
P.E.# 58705
1BY
WOOD BUCK
do v do v
a. a
f�
b
a
0
J
0
9
J
O 0
~ o
z
F
w
�C w
w U
U
A
w..o , v
EDGE
DIST. -
v. 1BY
WOOD BUCK
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
EDGE' .DIST.
d ° A
a °
'A
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
METAL
STRUCTURE
ow
EDGE TYPICAL ANCHORS
Y
¢
DIST. SEE ELEV.
F-
FOR SPACING
m M
V)
0
00
EDGE
DIST.
3
m
N
2
U
W
2
`.L
U
D
m
• z x
v v> \ U
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
14F
TYPICAL ANCHORS
EQUAL LEG FRAME CAN BE INSTALLED DIRECTLY
INTO WOOD, CONCRETE OR METAL STRUCTURES
WITHOUT THE NEED OF A WOOD BUCK.
2 3/8" MIN.
2 3/8" MIN. —�
\ \\♦
\
\
WHEN USED THE MIN. WOOD BUCK
DEPTH SHALL BE 2%". THE USE OF
DEEPER OR BEVELED WOODBUCKS IS
PERMITTED.
EDGE
DIST.
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
•d u
• A ° ,c9 °
. a v d \ Z•
',
EQUAL LEG FRAME
--------------------
j I MIAMI—DADE COUNTY APPROVED I j
I I MULLION & MULLION ANCHORS i I
�j SEE SEPARATE NOA II
I I
II EDGE
DIST. f;—------ II
------ -------- I
__J
t TYPICAL ANCHORS
SEE ELEV.
MIAMI—DADE COUNTY FOR SPACING
APPROVED M111I ION
o a
.1 !� . da a'
A,
I ITYPICAL ANCHORS
SEE ELEV.
FOR SPACING
Al
oN
Y
Q
N
O
?)
'Aga
ti
o
�
N
JLLJ a)
�?
0
O
a}DQ
z
z
Lo
}U' N O
W
o
Q0M
xe
oZLLm 5
Q
"'o
U)
uiUWo
U
z
Q00
�Zv
'IN
W OWS
>
U
SMa
rn
LL
0
v
adz°'
_
w
y U
C O Z
J
U
CO
m C ! uj
VJ In ¢ OfU)
z
J
}aa4S
vs W U
0 O U
W
3 o��
J
I—
LLl
W
z
C U
O
(D
z
CL U ccl)
co
-
U o co
Z
w
J
Q
o
0
—
Of
�.Lu
�(,
Uc')X
w
o
X
aµ!1
-isap
sauas
i I r s f
_ aka
(.° 12 -
�r fAv�ti
l�lit4titl.
A. LYNN MILLER, P.E.
P.E.# 58705
ILLUSTRATIVE DTLS. ONLY
EXT. OR INT. FINISHES
NOT BY CGI
HOUSE WRAP
NOT BY CGI
A2 ,
ES
6
IL
0
J
O
E„ 1
W
C 2
to
Z
w
w
�
V)
N
s4
I
HOUSE WRAP
NOT BY CGI
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
z
C
a•
TYPICAL ANCHORS: SEE ELEV. FOR SPACING
8 SMS (Fu=74 KSI, Fy=57 KSI)
E1 INTO 2BY WOOD BUCKS OR WOOD STRUCTURES
'J BACKBED 1-1/4" MIN. PENETRATION INTO WOOD
((A I CAULKING
SWEEP LOCK
OPTIONAL TO
EGRESS LOCK
AT SILL
TYPICAL ANCHORS
SEE ELEV.
FOR SPACING
BACKBED
CAULKING
Y
U
m
WOOD STRUCTURE 1/4" MAX.
NOT BY CGI
W
e.
FIN FRAME
Rllrk wrlrur 1/4" MAX.
C
O
N
N
Y
Q
o
•Aab
o
O
W
O
¢O
a}o4
z
O
W
C7 N
Q 0 co
O
Xe
QZLJL� a
Q
""o
(0
w Lu w
z
<t�zv
ON
°- owe
U
9M4
wo>�r
z
:D
2
w
rn
ILL
0
y U
C O Z
—I
�C O uj
z
}aa4S
y G w of
(q
W 0
O
owLij
J
W
z
z 1
Q
p � t�i r'
F¢-
U)
000 cD
w
W
-
o
_z�QM
��-j-
0
r
w
—
LL
=
U)
U c) S `✓
al}il
asap
Isaliagi
L
\�����i S gyp, .+ g f °Jf fi��.%•��
No. 587€ 5
r �'
OR
lo
! OF
1 N0 4
t'
A. LYNN MILLER, P.E.
P.E.# 58705
ITEM
PART #
QUANTITY
DESCRIPTION
MATERIAL
MANF./SUPPLIER/REMARKS
E1
CGI-100
1
FRAME HEAD
6063-T6
-
E2
CGI-101
1
FRAME SILL
6063-T6
-
E3
CGI-102
2
FRAME JAMB
6063-T6
-
E4
CGI-103
1
MEETING RAIL
6063-T6
-
E5
CGI-104
1
LOCK RAIL
6063-T6
-
E6
CGI-105
1
HANDLE RAIL
6063-T6
-
E7
CGI-106
2
SASH RAIL
6063-T6
-
E8
CGI-107
AS READ.
5/16" GLAZING BEAD
6063-T5
-
E9
CGI-108
AS READ.
0.700" GLAZING BEAD
6063-T5
-
E10
CGI-109
AS READ.
FRONT FLANGE ADAPTOR
6063-T6
-
E11
CGI-110
AS READ.
NAIL FIN ADAPTOR
6063-T5
-
E12
CGI-135
1
FLANGE FRAME HEAD
6063-T6
-
E13
CGI-136
2
FLANGE FRAME JAMB
6063-T6
-
E14
CGI-137
1
FLANGE FRAME SILL
6063-T6
-
E17
CGI-605
OPTIONAL
SCREEN FRAME
6063-T5
-
M1
CGI-382V
AS READ.
GLAZING BULB VINYL (DUROMETER 75-80 SHORE A)
PVC
-
M2
CGI-111
OPTIONAL
SCREW COVER
PVC
PROTOTYPE OR EQUIV.
M3
CGI-112
AS REQD.
EQUAL LEG COVER/SHIM, 3" LONG AT ANCHOR LOCATIONS
PVC
-
M9
SUPER BOOST
2/ WDW.
SPIRAL BALANCE
-
BSI OR EQUIV.
M10
-
2/ WDW.
BLOCK/TACKLE BALANCE
-
BSI OR EQUIV.
M11
W23201NG
AS REQD.
PILE WITH CENTER FIN
WOOL
ULTRAFAB OR EQUIV.
M12
CGI-129
1/ WDW.
EGRESS LOCK
ALUM.
SULLIVAN
M13
CGI-131
2/ WDW.
HANDLE RAIL END CAP
NYLON
M&M
M14
E26018WN
-
D BULB-T SLOT
PVC
ULTRAFAB OR EQUIV.
M15
CGI-133
4/ WDW.
SASH GUIDE(SPIRAL BALANCE)
NYLON
M&M
M16
CGI-130
2/ WDW.
SASH TOP GUIDE(SPIRAL BALANCE)
NYLON
M&M
M17
A30730401-32
1/ WDW.
CAM LOCK
ZINC
TRUTH OR EQUIV.
M18
CGI-132
2/ WDW.
SASH STOP, 2" LONG
PVC
PROTOTYPE OR EQUIV.
M19
-
2/ LITE
SETTING BLOCK
EPDM
DUROMETER 85±5 SHORE A
M20
CGI-125
2/ WDW.
SASH CAM (B/T BALANCE)
NYLON
M&M
M21
-
2/ WDW.
B/T BALANCE TAKE OUT CLIP
-
BSI OR EQUIV.
M22
146-6
2/ WDW.
WEEP COVER
NYLON
AMESBURY OR EQUN
M23
CGI-134
-
SILL SPACER
PVC
PROTOTYPE OR EQUIV.
S2
-
2 OR 3/CORNER
# 10 X 1 1/4" LG. PHL. PH. SMS. ST/ST. ASSEMBLY SCREW
-
-
S4
-
4/ WDW.
# 8 X 1/2" PH. SMS. ST/ST BALANCE BRACKET SCREW
-
-
S5
-
2/ WDW.
# 8 X 1" LG. FH. SMS. ST/ST. SPIRAL B. ASSEMBLY
-
-
S6
-
2/ LOCK
# 6 X 1/2" LG. FH. SMS. ® CGI-133 & CAM LOCK
-
-
c
0
N
Y
Q
04
O
Ui
'naa
w
o
O
()
rn
rn
0
a}oQ
�> C14
Z
O
W
.0 N
O
QO�r
-Zt-(D Z5
o
un+n0
cn
wUwo
Z
<
> >
>
'ON
z 4
w^ jr
09Mo
v
adz°'
:D
=
w
rn
LL
0
•. i Z
c o
J
�
00
o
r
to G ¢
_Z
(n
m
}aa4S
MA 0J
� o ow
Q
W
w o Z
Q
W
d C �= M O.
E� 3 N J�
C)
c-
QQc
G
W
� LL
u
(n
Z
W
Q
J
O
�w _
J
Uco<
m'n
W
m
=
m
aµil
•asap
sar�aS
.tl�?Sltttai�
l
o. 5870
NY L V
fffi''iili}'{il\`;,.'
A. LYNN MILLER, P.E.
P.E.# 58705
2.505
2.505
�.065
S2
S2
06511
1.745 .811
811
1.245
1.550 1.680
.745 .06
TYP.
.745 .065
TYP.
.050L1.015 7395
i
1.015
E12 FLANGE FRAME HEAD
E� FLUSH FRAME HEAD
E11 NAIL FIN ADAPTER
1.583
1.583
1.007
.745
.065
.065
TYP.
TYP.
.065 2.113
TYP.
,
3.675
1 429In
065
3.175
1 429
t A
3.175
1.368
1.015
VENT TOP CORNER
i
1.000
.500
500
��
2.505
1.220
E4 MEETING RAIL
FRAME TOP CORNER
2.505
E14 FLANGE FRAME SILL
E2 FLUSH FRAME SILL
1.220
1.043
.500 1.301
j�-1 301
1.788
065
S2
0654E.TO6.
.065 .065
NP'
TYP.
I
1.015 Imo-
2.440
1•015
LL32
2.440
�
1.015
E5 LOCK RAIL
FRAME BOTTOM CORNER
VENT BOTTOM CORNER
.745
2.846
I .745
IF�
2.195
E13
2.346
E3
FLANGE FRAME JAMB
FLUSH FRAME JAMB
1.892
65
1.043FM.jO
YP.
T
.12-�{
70� 5 FR 050 TYP.
7K+.050 TYP.
1.015
1 S2
�i .864
.864 Fes-
E6 HAND RAIL
Es
E9
5/16" GLAZING BEAD
.700" GLAZING BEAD
1.395
1.395
i F i��.180
vil
1.449
.293
.7451.450
665
.675
.180
.050 1-
.060 �1-1.413A�
�-
550 050
.065
M3 FLUSH FRAME COVER
M19 SCREW
E7
E10
COVER
SASH RAIL
FLANGE ADAPTOR
c
0
Q
N
Y
Q
N
o
•Aab
LLJ
ti
o
N
OQ,
Q
O
a}op
t
Z
Z
Lo
O
J C7 N
-'
o
Q o V'7
J C
r
�
Qz LLL.. � -0
Q
IIMDJp
U)
w=w`- w
� o
Z_
LLJ
'ON
aow^
wr>�
C0
pM0
a-Z°'
z
2
w
rn
W
0
w O uj
Z
W
o
0
O W
W
= Q�0
Q
U)
=_ �=c)
0 �
O
W
V)
LL
o CO
W
Z C) -
O
�coQo
Ucri2�
W
X0
W
=
911i1
asap
sauaS
1
No- 58705
2-TF
�
A. LYNN MILLER, P.E.
P.E.# 58705