Loading...
HomeMy WebLinkAboutpoduct approvalGo�Nn DEPARTMEFiT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTIC9 OF ACCEPTANCE (NOA Lomanco, Inc. 2101 Wesi Main Street Jacksonville, AR 72078 MIAMI-DADE COU Y PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 08 Miami, Florida 33175-2 74 T (786) 315-2590 F (786) 315-2 99 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA E hall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this prod or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, t manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the ust of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requiremer of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: OmniRidge Pro PR04-N and PR04-SWN Ridge Vent TRI-BUILT® OmniRidge Pro PR04-N and PR04-SWN Ridge Vent LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the appli able building code negatively affecting the performance of this product. .lMRDIIN TION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, me, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, sales, adve ising or any other purposes shall automatically terminate this NOA. Failure to comply with any section this NOA sl all be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and folk by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, it shall be one in its entirety. INSPECT ON: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA 18-1107.03 and consists of pages 1 through 4. The submitled documentation was reviewed by Freddy Semino NOA No.19-1217, Expiration Date: 10/01L Approval Date: 01/21 Page 1 o ROOFIN COMPONENT APPROVAL CateLory Roofing Sub -Cate Ventilation Materials: Plastic TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product roduct Dimensions Specification Description Lomanco muiRidge Pro Length 4 Feet TAS-100(A) Low profile attic ridge vent for i. PRO-4N and PR04-SWN Width 14 %2 Inches under ridge shingles. Ridge Ven Height 1 Inch TRI-BUILT®OmniRidge Length 4 Feet Pro PR04 and PR04- Width 14 %2 Inches SWN Ridgi Vent Height 1 Inch MANI 1. J LOCATIONS: EVIDENCE SUBMITTED: Test ALyencv PRI Construction Materials Technologies TAS-100(A) Low profile attic ridge vent for instal under ridge shingles. Test Name/Revort TAS 100(A) ASTM D 1929 ASTM D 635 ASTM D 2843 Test Identifier Date LOM-045-02-01 04/28/ 15 LOM-034-02-01 03/28/ 14 LOM-033-02-01 03/28/14 LOM-041-02-01 06/05/ 14 NOA No.19-1217.( Expiration Date: 10/01/2 Approval Date: 01/23/2 Page 2 of APPROVED APPLICATIONS Tradena e: Lomanco OmniRidge Pro PR04-N and PR04-SWN Ridge Vent TRI-BUILT a OmniRidge Pro PR04-N and PR04-SWN Ridge Vent System Type: Mechanical attachment of ridge vent over asphalt shingle roof systems only. Cutout: Truss Construction: Cut shall be 1-3/4" wide and 6" shorter at each end than the total the ridge vent to be installed. Ridge Pole Construction: Cut shall be 3-1/4" wide and 6" shorter at each end than the total length of the ridge vent to be installed. Installation: Starting from the end of the ridge, center ridge vent over the slot and fasten using approved i shank nails at 12 inches on center in molded hole locations (ten nails per vent section). - Ridge Shi gle: Install pre -manufactured or field -cut ridge shingles over the ridge vent in compliance with the shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions. Ring shank nails shall be corrosion resistant and long enough to penetrate through the wood deck a minimum of 3/16". Net Free Area: Refer to manufacturers published literature. LIMITA 1. Refer to applicable Building Codes for required ventilation. 2. This acceptance is for installations on asphalt shingle roof systems only. 3. Lomalico OmniRidge Pro PR04-N and PR04-SWN Ridge Vent and TRI-BUILT ®OmniRidge Pro PR04-N and PR04-SWN Ridge Vent, shall not be installed on roof mean heigh s greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code an Rule q, 1 G20-3 of the Florida Administrative Code. 5. All ap' roved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo and following statement: "Miami -Dade County Product Control Approved" or the Miam -Dade County Product Control Seal as shown below. APPROVED APPROVED NOA No. 19-1217 Expiration Date: 10/01, Approval Date: 01/23, Page 3 c Lomanco OmniRidge Pro PR04-N and PR04-SWN Ridge Vent TRI-BUILT®Omni Ridge Pro PR04-N and PR04-SWN Ridge Vent i a �4 4 � z r � DETAIL DRAWING END OF THIS ACCEPTANCE NOA No.19-121 .04 Expiration Date: 10/0 /20 Approval Date: 01/2 /20 Page 4 f 4