Loading...
HomeMy WebLinkAboutDensity Report From fax5616880909 1.161.688.0909 Mon Nov 30 12:19:16 2020 MST Page 1 of 1 LIES Project No: 3310.1500002.0000 A Universol, Workorder No: 218626-1 i Eogit<eGririg Report Date: 11/25/2020, Sciences r , Company �RNATlc� , 607 Northwest Commodity Cove,Port St.Lucie,FL 34986 -P:772-924-3575 F:772-924-3580 In-Place Density Test Reppq Client: GHO HOMES CORPORATION UES Technician: Sean Hayes 590 NW Mercantile Place Date Tested: 11/23/2020 Port St.Lucie, FL 34986 i Project: MEADOWOOD SUBDIVISION (FDC) Meadowood Dr.Various Lots, Fort Pierce, County, FL 34951 Tue of Test_ Area Tested: 9630 Knoiiwood Lane, Lot 57 Field: ASTM D-6938 Nuclear Gauge Method ' Material: Native Laboratory: ASTM D1557 Modified Proctor Reference Datum: 0 =Top of Native I The tests below meet the 95%minimum compaction requirement. Maximum Optimum Field pry Field Soil Pass Test Density Moisture Density Moisture Compaction or i No. Location of Test Range (pcf) N (Pcf) (%) (%) Fail 1 NE Comer 0-1 Fi 115A 10.9 112.9 10.3 98 Pass 2 SW Comer 0-1 It 115.4 10.9 110.8 9.8 96 Pass 3 Center 0-1 ft 115.4 10.9 112.0 10.2 97 Pass Reviewed By GFA International,Inc Certificate of Authorization No.4930 \`�t�rrrt!ffrir I ' � ti,cENs�•. Y No 63218 Kent,W6E of &I- Pi 'tttzjt�r' er '18 State'o ,'AL I II i III I I To establish a rnutual protection to Universal's clients,the Public and ourselves,all reports are submitted as confidential properly of our clients and authorization for publication of,statements,conclusions or extracts from or regarding Universal's reports is reserved pending our Written approval. Page I I I