HomeMy WebLinkAboutBuilding Plans12 Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails aced 4" o_c_ at -all laps -and -two staggered rows 12" o.c. in field. Attach RIGHT ELEVATION 12 4 1 SLOPE LEFT ELEVATION 5/8" thick x 8"w cut coral finished stucco bands SCALE: 1/4" = 1'-0" Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12 26 ga. Sv crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 Ib felt underlayment installed with min. 4' side laps and 6" end - laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails aced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach eck to trusses using attachment detail on this sheet -------------- 5/8" thick light textured stucco on typical concrete block construction SGAI I/'Y = I'-U- Product Approval Submittal Affidavit IN Opening Sohedule Swing ])core, Overhead Doors, Sliding Doors, Vindows & Skylights Opening Type NOA/FL NUMBER Product Model Manufacturer Glass Attachment method Exppiration Date Design Pressure of Approved Teats 1,2,3 t4 FL# 239.9g Single Hun 5H-1100A Im act PGT 5/IL" I/4° d,a eapeora r/ min 13/8" spaced per product approval min. edge distances specified penetration to be Contractor shall adhere to in Product approval + 65.0/-80.0 PSIF A I6-0330.02 Overhead Garage Door Model 824/e11 9' 4" max. width IL'-O" max height DAB fluti s �yr"� = Wry. • c �«.,,. n� a„h-67 mu fl 5iie" x I Sir fw t ad ip n seeh bracket. mme.nms en ar Ir ed,a a.e.xe -bt�ie t" .see adhan to pr"dvet apprw.i 10-9-21 + 50.0/-LO.O of p B FLU IL614.1 Fiberglass smootnh Pro/ Jeld-Wen Elco 1/4' dia. tapcon with min 1.25' embedment at 3' max from corners and 11.5' o.c. max. thereafter in head and jambs. + 50.0 PSF C FL# 251.4 Sliding Glass g Door Series 110 SGD PGT In mom Type "GSA" 1/4' dia. tapcons w/ min. I i3/4C' penetration to be spaced per product approva. ontractor shall adhere to min. 2 1/2' edge distance& specified in Product approvalTES + LO.O PSF - Product NOA/FL NUMBER Model # Manufacturer Attachment Method Expiation Date Design Pressure of Approved Teats Mullions FLU 2L1.1 In x 2 3/4" x .315' natal] per fastener type and spacings shown in Table IA and IB In n product approval on sheet 5 of 22. + 58.0 PSF Roof FLU IIL51.12 5V Crimp Metal Roofing g Gulf Coast Supply and manufacturing 2L ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self waking washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlayment installed with min. 4 side laps and L" and laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on roof plan - 108.5 PSF Siding Stucco an Block Soffit FLU 12198.3 Model T4 12" vented Vinyl Soffit Kagcan Install using 2" x 2" battens at V o.c. screwed to soffit framing using #8 x 3" wood screws at each truss. Install soffit to battens using 0.12' dia. x 1.5" Iona ring shank mails with S/8" dia head, +55.0/-35.0 PSF Hurricane Panels I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record 12 Finish Columns with 5/8" thick cut coral finished stucco bands 0'-0" = Finished i 5/8" thick x 8% cut coral finished stucco b 2" x 4" top plate 1I 1/2" drywall ceiling on truss bottom cord I/2" drywall on 2" x 4' studs at 16" o.c. base -board � 11 11 2" x 4" P.T. bottom plate \ 4" concrete slab with fibermesh OR 6"xV #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill nterlor Non -Bearing Partition nts Braden t Braden AIA, PA Architects - Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: bradenaia9comcast.net Stuart_ FL S4994 #AACOOOOS2 Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb Felt underlayment installed with min. 4' side laps and L" and laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced V o.c. at all laps and two .staggered. rows 12" o.c. in field. Attach COVERED -1 w. PORCH 2 F I 1. °loor 5/8" thick light textured \ I stucco on typical concrete 5/8" thick x 8"w cut block construction coral finished stucco bands REAR ELEVATION WLmne Building Corp. THE ROYALS Spanish Lakes St. Lucie County Florida SCALE: 1/4" = I'-O" Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 Ib felt underlayment installed with min. 4' side laps and L" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails aced L o.c. at all laps and two staggered rows 12 o.c. in field. Attach deck to trusses using attachment detal on this sheet 12 4 1 SLOPPE 1/8" Thick cut coral stucco over paper backed wire lath nailed to substrate through one layer of 15 lb Pelt using Sd nails. Substrate to be 19/32" COX Plywood nailed at 6" o.c. in field and edges with IOd ring shank galvanized nails into truss webbing. 2'-2" 5/8" thick FRONT ELEVATION coral finish& SCALE: 1/4" = 1'-0" 12" x 8"w cut d stucco bands 24,d0-" i9 o 3-6 REVIEVi EUFOR CODE C®MPI", I ALL CONTRACTOR WARRANTIES BEGIN WHEN T19,ENCLOSING OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP. AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE PERMITTING INFORMATION (FORM 100) Florida Budding Code Residential: Lth Edition and ASCE 1-10 for Wind Loading Building Design is: Enclosed Risk Category: It Wind Velocity: 165 mph ultimate Mean Roof Height: II'-O" Roof Pitch: 4:12 PROOPSIXIIACH Internal Pressure oe Icient: ±0_I8 Subjectabdity to damage from: Weathering: Negligible Termmtes: Vera HaI Width of Roof End Zone: 3'-4" Wind Speed: IL5 mph ultimate Wind Exposure Classification: C Adjustment factor for Exposure Height: 1.21 x 0.4 = 0.126 ASD design Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL: O.LDL+O.t.WL Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.L/-32.4 psf Roof Zone: 2. +20.L/-51.0 psf Roof Zone: 3. +20.4/-84.0 pef Components t Cladding Wall End Zone Width: 3'-4" Components t Cladding Wind Pressure (NET) Well Zone: 4. +35.8/-38.1 psf _ 0 ZonZone 4 I Wall Zone: 5. +35.8/-41.8 psf Wills Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3psf Shear Walls Considered for Structure? Yes Continuous Load Path Provided? = Roof Zone 2 es Walls Zone 5 Are Components an Cladding Detel s Provided? Yes END ZONE Minimum Sal Bearing Pressure:2 O psi, Presumptive: X B14 Test: psi SEE PRODUCT APPROVAL FOR IMPACT PROTECTION FOR OPENINGS mm= Corner Zones Roof Zone 3 ROOF LIVE LOAD:_ psf ROOF DEAD LOAD: 10 psf FLOOR LIVE LOAD: � of FLOOR DEAD LOAD: l0 sf JOB ADDRESS: MODEL: Date Drawn Revisions : \' 3-28-18 5-23-18 Smoke detector revision GARAGE Drawn by: LEFT C.C.U. Checked by: D.R.B. Sheet I Comm # OF 5 B I' FLOOR PLAN 21'-O" TYPICAL NOTES: SCALE 1/4" = 1'-0" AREA CALCULATIONS N.T.S. = I. Contractor to verify ALL notes and dimensions prior to 36° high by 4° diameter 1-120 sq. ft. Living A/C steel crash post. Floor Back Porch Total = 210 S ft. proceeding with work. Flange with 4 - 3/8" q 2. Contractor to STRICTLY enforce ALL OSHA Requirements. ex ansion bolts Into Garage = 311 sq, ft, 3. ALL Lumber to be used as Beam, Rafters, etc... to have slag (3/8"t So ksi steel plate) Entry = 28 sq. ft. a minimum 1,400 P.S.I. fiber stress. Total Under Roof= 2215 sq. ft, 4. No dissimilar metals to touch. 2h" 2'/2" Total Cubic Ft = 13,140 S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. " �2" ALL Concrete used for vertical filled cells, cont. tie beams etc.. to ° Z• VTR shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix in 03/8" 0 2"/2" JV j 6. Drywall at ceilings shall be leveled and attached to bottom chord 2" 2�„ Attach buck to block wall with I I of trusses with screws per FBC R102.3.5. 114" dia. Elea cone screws with min. 12" I MASTER 1. ALL wood in contact with concrete shall be pressure treated. D O 11/4" penetration at 12" o.c. max BATH and 4" max from each corner thru " I LAV-1 8. ALL wall dimensions are nominal and not finished wall or stud dimensions. h" Exterior race 2" x L" PT Buck LAV-1 9. ALL plumbing fixtures to be low flow. or wall- I 2' 10. Contractor to Provide Drain at water heater in accordance ones Iwm-I with the current edition of the Florida Plumbing Code. we-1 2" 11. Contractor to Provide a 2'-8" wide door at one bathroom for a9 woad screws thru iamb into buck 2" LAUNDRY 3" „ at each hinge and 15" amb max and ll handicap accessibility requirements. s/2" 2h Detail at Door Prior to door attachment ET-1 2 12. Lowest finished floor to be set bg Governing Building Department L" NTS 2" 3 j r AAv *2" VTR surveyor to Set In field. INSTALL VULKEM BLOCK SEALANT 13. Separation between residence and garage shall be per FBC R302.b ON ALL JAMB. HEADER, AND KTICHEN 2" SILL BLOCK 1-4. Door between garage and residence shall be 1-3/4"t 20 min. rated door INSTALLATION PRIOR TO BUCK 2 LAV-11 3" 2 it Water Heater Install windows thru buck into block with 3/16" tap -con with 1 1/2" penetration at V o.c. max 2" 15. Wall and Ceilin shall have a flame -spread classification of not greater than 200 er FBC R302.9.1 from each cornj,ia and d 2 " max 3" wo-1 BATH #2 p thereafter andtsillaper productt"approvalx Ib. Wall and telling finishes shall have a smoke -developed index of not greater than 4 O per FBC R302.9.2 Exterior face 2" 11. All exposed attic insulation materials installed on attic floors shall have a critical radiant or wall "ari x 4" PT 31, ST_1 flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation C.O. materials exposed on the underside of the roof deck or on the attic walls shall comply 3 with F.B.C. R316 - see permit info box of code edition To septic 18. Gypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931 Buck nailed to C960, C1002, C1041,C1111, C1118, C1218, C1395, or C13% and shall be installed Detail at Windows case hardened nails PLUMBING RISER accordingto the following: (FBC R102.3.5) prior to window attachment g I" x 6" P.T. Buck nailed to Masonry $ee NTS block with case hardened nails / prior to door attachment Dr wall Framing Max. spacing y Thickness Location Orientation Member of fasteners Nail sizing options for drywall into Spacing Maximum installation of wood framingmembers Nails Screws 2" x min. thickness Ceiling Perpendicular 24" 11. 12" 13ga 1 3/8" long with 19/64" head 0.098" diameter x 1 1/4" long /2 annular -ringed or Sd cooler nail OR 0.080" dia. xx 1 5/8" long with Walls Either 161, all IV Direction 15/44" head OR Gypsum board nail 0.086" dia. x 1 5/8" with 9/31" head. Ceiling Perpendicular 24" 1" 12" 13ga 1 6/8' loong with 19/64° head 0.098" diameter x 1 3/8" long annular -ringed or 6d cooler nail Walls Either IL" ell I6" 0.092" diaoxx 1 1/8" long with Direction I/4" head OR Ggpsum board nail 0.0915" dia. x 11/8" with I9/64" head. � CRASH POST DETAIL 19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6, A108.1, A118.1, A118.3, A136.1 and A131.1 20, Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM C1288, C1325, OR CII18 and installed I.A.W. manufacturers recommendations shall be used as backer for the wall the in tub areas and wall panels in shower areas. 21. Insulation including facings such as retarders or vapor permeable members installed within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics shall have a flame spread index not to exceed 25 with an accompanying smoke developed index not to exceed 450 when tested in accordance with ASTM E 84. Insulation shall comply with F.B.C. R316. Grade Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11461.12 26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5" wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlaymant installed with min. 4' sidelaps and V and laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet Simpson HETA 20 or equal hurries e anchor at each truss 12 with (10) i� x 11/2 nails 4 �- PRE-ENGINEERED TRUSSES ( 24" o.c.) supporting Max. at 24"o.c. TYPICAL IBlolba. uplift -1 (shop drawings by manufacturer) Aluminum Drip `� '-� Y-yxxx!xxxxxxxxxxxx R-30 blown fiberglass Edge t Fascia in bottom chord of trusses I/2" drywall with smooth finish 2" x 6" Sub -Fascia Two rows of beam block filled with concrete and (l) 95 bar cont. in each row. Substitute Kaycan full o vent vingI eoPfit installed precast lintel filled with concrete and (1) #5 bar for bottom using I/e" dia shank x I5" long ga1v. Cont. row over openings roofing nails with 3/e" dia. head per product approval - see chart sheet nl 1/2" drywall over I" x furrin 01-foll at 14" O.C. with R4.1 rstrlps insulation on typical 8" Block walls 5/8" thick light textured = All drywall to be installed per FBC R7023.1 stucco on typical concrete T and shall meet all pertaining ASTM codes. "M" block construction ao Mortar to be Type onlg proportioned per FBC R601.1 and Mortar Jonte shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...> #5 bar vert. w/ 30" overlap Fill cell with concrete and at each filled Bell (U #S bar vert. (typical). Max. spacing shall not exceed Wood 48" unless otherwise noted see foundation plan notes for Base spacing at openings 4" concrete slab with fibermesh OR VxV #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill � I +I-IMIMI-1171 I i l I I I I 1 -IIIIIIII=IIII IIII IIII= 14"w x 18"d Concrete footing 1 1-1 1 11 1 i'- with (2) #S bars coot. and #5 14" transverse bars at 48" O.C. TYPICAL SECTION Scale : 1/2" = 1'-0" Install SGD thru buck into block with 3/16" tap -con with 1 1/2" penetration at L" o.c. max. from each corner and 20." o.c. max thereafter at head per product approval O O Use 3/16" tap -con with 1 1/2" penetration at 6" o.c. max. from each corner and 20" o.c. max thereafter at sill per product approval I" x 6" P.T. Buck nailed to block with case hardened nails Head prior to door attachment fixed door sliding door9 N Masonry Wall v2" =1 Bottom Track Typical Flooring - Sill Install SGD thru buck into block with 3/14" tap -con with S l l d l n D OOr Detail 1 1/2" penetration at o.c. max. g from each corner and 20." o.c. max At Masonry Wall NTS thereafter at Jambs per product approval Jamb Window Schedule Mark Size Rough O en. Window Descrl tion PRESSURE ZONE I. 4'-5'/e"x S'-3 %" 54/s"x 0W Single Hung ZONE 4 2. V-2%'x V-3 %" 15" x L3 %4" Single Hung ZONE 4 3, 2'-2" x V-2/2" 21%'x 38%" Single Hung ZONE 4 4, 3'-I" x V-3i," 38" x 0'/4" Single Hung ZONE 4 S. 4'-531e"x 4'-2'/.' 1 54%s°x 54 V Single Hung ZONE 4 ALL Windows to be aluminum windows w/ tint and mullions per elevations. ALL windows to withstand pressures in permit info box on sheet I ALL windows in bathrooms to be tempered All rough o. dimensions to be verified by contractor ur rq with manufacturers specs prior to construction Door Schedule Mark Size Rough Opening Door Description PRESSURE ZONE A T-ON X T-OR 108" x 84" Overhead Garage Door ZONE 4 B 3'-O" X C-8" 41"'/;' x 83%" Fiberglass Panel - Inswing ZONE 4 C 6'-O" X L'-8" Llw l4' x el %," 'r ;ale, Sliding Glass Door ZONE 4 D 2'-O" X V-8" solid Core - Wood - 6-Panel -Bi-Fold Finished 24" x 81 �2" E 2'-6" X C-8" Solid Core - Wood - L-Panel F 5'-0" X V-8" solid Core - Wood - 6-Panel - Bi-Fold G 2'-8" x C-8" x 1 %" Solid Core Wood, Steel, or Masonite Door H 2'-B" X C-8" Solid Core - Wood - 6-Panel J 2'-0 X V-am Solid Core - Wood - 6-Panel - Bi-Fold ALL Exterior doors to withstand pressures stated box on sheet 41 GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX All rough opening dimensions to be verified by contractor with manufacturers specs prior to construction in permit info AND SHALL ON SHEET 91 Braden t Braden AIA, FA Architects - Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: bradenaia8comcast.net yl-Oil 7i-Oil EGRESS MASTER BEDROOM � 8'-O" A.P.F. Flat Ceding 12'-8" b ir N Vanity to be 34 Y2"high 301 7.111171111 O 4" �I OI -Ol1 Opt. PATIO/SLAB C12" x 12" Concrete column - block filled with concrete ar (2) #1 bars vert. tied Into lintels above PORCH WIRE LATH t STUCCO CEILING 01 00 I I I I Ell MT 1 I to 19'-8" A.F.P. Vaulted 1Ceiling I 2o'r8" 6'-O" 6'-4" I G R EIA T ROOM lip I s 2" x 4" knee -wall ®rj E I in below counter top 1 1_9 I J � e„ Rod t S11 /ryr�n p F DINING ROOM - +41" HIGH WALl1 e'-O" to T-8" A, I ° " IIRV Vaulted Ceding I 8'-0" A.P.F. I I O s Flat Ceiling 1-1/2" VIERHANG v -_ - - - - KiTCHtR- O covieets to �r extender Ref 12'-6" � 0'-5„ mil sin. m N o NON-VBNT THIRD fn 4'-0" F0 O ° BEDROOM ° 0 G _ _ 0 A.F.F. OI u) ° Flat Ceding = K O A/C I #1 r R-II Bata Inelation I 22i x 5Y lj H. f Attie Access � �I J N LU O 4 Provide auto I with light �a, 10 \o 1 4" 3O" 4" 3'-Ol, closer L - -__- I > Im 4"b Steel Ballard See detail on this sheet I \�% I Q,, r U7 11I y J J ° 1'0 mp ° ® Linen Double Dou le Pan I Hanging D Han n S ° 2" B,4 o GARAGE II E „H H.B. +) m Yanity to be 8'-4" A.F.F. 3 y2„N Flat Ceiling Be_____-_-_ Li-0 O r________ ) � Double anging a d- ; Block wall in j O pn _ - I garage to be ° struck block a I MT ° ° O'n ° o Q EME GENC I EG ESS I I c uU OD I I a .r 1 Jut I I IL ®-8.°O9 SECOND BEDROOM 8 O A.F.F. ° Flat Ceiling ALE C P C EGRESS � Lk o o O N O 9'-0" 3'-6" 2"-8" 2'-8" 2'-2" 9'-61, 2i-2" 15'-10" 5' -4" 13'-10" 31 35'-O" i L,;nne Building Corp. THE ROYALS Spanish Lakes St. Lucie County Florida Date Drawn Revisions : 3-28-18 5-23-I8 Smoke detector revision GARAGE Drawn by: LEFT C.C.U. Checked by: D.R.B. Sheet Comm # 2. 12-ioo OF 5 .J 11CU1.., I Ullz�/"_�1— IN'` I T__J" I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL 8. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN PROPER ENGINEERING DATA FOR DESIGN. 2. ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS 9• DESIGN LOADS ARE AS FOLLOWS: ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI ROOF (DL+LL) = 41 PSF BE 3000 PSI OR 4,000 PS( GROUT MIX AT 28 DAYS WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41 EXPOSURE ="C" 3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS, NO SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION. 10. ALL REINFORCING STEEL SHALL BE GRADE 60. MEETING ASTM A-16, E 4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10 A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL. WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL 11. ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR (MINIMUM DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE. MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH. BE FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS, SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE. 5• LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS BEFORE FILL IS BROUGHT IN. FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL 1 2, MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS: PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE FOOTING: 3" STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND BEAMS: 1-1/2" COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY PROCTOR VALUE. 13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS. 6. GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND 14. USE STRUCTURAL GRADE WOOD WiTH A MINIMUM Fb OF 1400 PSI DIMENSIONS. BRiNG ANY DISCREPANCIES OR OMISSIONS TO THE ATTENTION OF THE ARCHITECT. I5, ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000 PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE. �• GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR 14. ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. FASTENERS TO HAVE MIN. GIBE RATING. FOUNDATION FLAN I. Any changes to plans must be submitted to the architect for approval before proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions before starting construction. 3. Soil conditions assumed to be 2500 psf. Should any other conditions be encountered, the architect shall be notified in writing for revision 4. Verify all recess thickness at showers, tile, etc.... S. Contractor to provide filled cell with concrete and 1 45 bar Vert. at .48" O.C. max. Provide (1) filled cell on each Side of Openings upp to 5'—I1" wlde. Provide (2) filled cells On each side of openings from 6'—O" to 9'-I1" and Provide (3) filled cells on each side of openings from 10'—O" and up Contractor to see plans for any Other condition used. Foundation walls shall have filled cells at 24" o.c. unless otherwise noted (see section) 6. Contractor to provide for Form Board Survey — Form Board Survey to be provided to Truss Company prior tc) truss construction 1. Contractor to provide for soil test prior to construction and provide a copy of Sol[ test to architect for review prior to construction 8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and A-35 specifications. ALL Anchors to be A-301 steel. 9. Provide a minimum of 3" concrete protection at footings and 1-1/2" concrete protection at beams for ALL reinforcing bars. #5 bar vert. w/ 30" overlap Fill cell with concrete and (l) #5 bar vert (typical). Thicken edge to 8 x8 SCALE: 1/4" = 1'-0" FOOTING SCHEDULE Mark Size Description I 14"W x 18"D MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS F 12"W X 12"D MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS F 30" x 30" x I6"D COLUMN FOOTING WITH (4) #5 BARS EACH WAY F� 8"W x 8"D THICKEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS F5 14"W With x I8"D Curb at Garage MONOLITHIC FOOTING WITH 2 45 BARS CONTINUOUS - CURB a 0'-0" at each filled c Max. spacing shall not exceed with concrete and 4" concrete slab with fibermesh OR Wood 48" unless otherwise noted one #5 bar continuous 6"A" #10/10 WWM on 10 mil Visqueen over Base see foundation plan notes for clean compacted termite treated fill spacing at openings 4" concrete slab with fibermesh OR GRADE 6"x6" #10/10 WWM on 6 mil Visqueen over "` "''`a' clean compacted termite treated fill 0D ;,`'.. — ih PIM `'' i i1 I I I-1 I I��I I I I❑ 1 I 14% x 18"d Concrete footing with (2) #5 bars cont. and #5 transverse bars at 48" o.c. TYPICAL FOOTING DETAIL SCALE 1/2" = I'-U" 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 10 mil Visqueen over clean compacted termite treated fill #5 bar cunt. Step per foundation plan ci #5 bars cont. bottom steel ff :21 DETAIL AT GARAGE STEPDOWN �J SCALE 1/2" = 1'-0" 12" x 12" concrete column block filled with concrete and (2) #1 bare vert. tied into lintels above Top of Tooter 14" below finished floor #5 bar cont. in Curb height Verifq based oil foundation plan LO Grade PORCH SLAB EDGE DETAIL 3 ARA( 0 SCALE 1/2" = 1'-0" #5 bar vert. w/ 30" overlap at each filled cell FIII cell with concrete and Termite Protection for New Construction. Soil treatment used for subterranean termite prevention inside the foundation perimeter shall be done after all excavation, backfilling and compaction is complete. If soil area is disturbed after initial chemical soil treatment area shall be re -treated With a chemical soil treatment including spaces boxed or framed_ Treatment must be in accordance with the rules and laws established bg the Florida Department of Agriculture and consumer services. Protective sleeves around metallic piping penetrating concrete slab on grade floors shall not be of cellulose containing materials and shall receive application of termrcide in annular space between sleeve and pipe. (1) 45 bar vert. (typical). Filled Cell Masonry Column With One —Max. spacing shall not exceed #5 From Footin To Tie Beam 48" unless otherwise noted g see foundation plan notes for Conc. Fill To Be 3000 PSI spacing at openings See Floor Plan For Location 4" concrete slab with fibermesh OR Vxb" 410/10 WWM on 6 mil Visqueen over / clean compacted termite treated fill O ......,.1.... .. -I1— 14"w x 18"d Concrete footing with (2) #5 bars cont, and #5 transverse bars at 48" o.c. RB DETAIL SCALE 1/2" = I'-O" 1III= 30"x30"xl6" concrete 2" x 6" PT wood secured with I/2"dia. x 6" expansion anchors \ column footing with (4 with 2" sq. washer at 18" o.c. overhead door track secured to wood 1*5 bars each way jamb per manufacturer's product approval Garaqe Door Jamb Detail GARAGE DOOR TO WITHSTAND PRESSURES STATED NTS IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT /2" = I'-O" APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL. Single Filled Cell COlumn NTS Filled Cell Masonry Column With One #5 From Footing To Beam Each. Conc. Fill To Be 3000 PSI See Floor Plan For Location D E Contractor to pi (l) proper foundation for proper steel 30" min. Double Filled Cell Column Corner Steel La NTS Braden It Braden AIA, FA Architects - Planners 411 S.E. Coconut Avenue Tel : (112) 281-8258 Fax : (112) 281-8283 E-mail: bradenaia9comcast.net griisirt FI ,,4ggL ttdO1`nn()n1A2 nts O I N O T a_ H.B. — 14'-0'" Opt. PATIO/SLAB 12" x 12" concrete column block fell F4 m Into lintels above (2) #1 bars ve N r i l i i i 00 °O --- o _1 ° F F T FI I Filled cell under O girder above Io I I 03 � I FI 24" Rear Porch Slab to W Y be poured separately 1L J from House Slab. r Thicken footing to N t 24"w x 14"d x 2411L under filled cell 1 a i under girde74" N ° ° OC ---- C Rear Patio/Slab to be flush with bottom of sliding door recess.Slope I" slab with fibermesh OR 1 60sx6" #10/10 WWM on 6 mil Visqueen over 1 clean compacted termite treated fill 1 I FI 1 I I ° I I c I I i ° I I �- I I° ° I 1 I I FI I I I ° I r— — — — — — — — — — I 1 C- #I I _ W' I i 40 " Steel Ballard —/� I I I O I See detail on this sheet 1 I I Q� 1 r- 14I I I I I 4" concrete slab with fibermesh OR I I 1 L"xV #10/10 WWM on 6 mil Visqueen over I I O clean compacted termite treated fill I I -i I Q I I FI �I D O I ° I FS ° L-------------AJE _ �_ I 1 C 12' -6" 0131 00 1.5" Recess for ° ° Garage Door I� I I I I .I I` I 1 ° JC UJynne Building Corp. THE ROYALS Spanish Lakes St. Lucie County Florida 9'-0" 2'-2" 9'-6" 2'-2"" GARAGE LEFT Date Drawn Revisions : 3-28-18 5-23-I8 Smoke detector revision Drawn by: C.C.U. Checked by: D.R.B. 0 I 0 H.B. FILE 0 0 r Sheet Comm 4 3 12-100 B OF 5 ROOF SHEETING ATTACHMENT DETAIL I. Minimum Nall Size = 8d ring shank (min. 2.5" long) 2. Minimum Screw Size = 48 x 2" 3. Minimum Sheathing Thickness 19/32" COX Plywood 4. Use nails or screws based on ress re for roof stated in permit info box on these pPans fpor zone 3 Ke Area Edge Field Fastener Pressure Zone I 6" 6" 8d ring shank 45 psf Zone 2 6" 8d ring shank 16 psf Zone 3 8d ring shank 84 psf ** Zone 3a 6" 6" #8 wood screw 112.5 psf ** Use nails or s rews based on pres§ure for roof stated in permit info cbox on these plans for zone 3 Concrete / Lintel Column Verify with Plan Provide #5 bare with min. 48 bar diameters overlap into beam. Tie filled cell steel Into continuous beam block steel. Provide Cast -Crete SUB-OB/OT precast -�'- lintel set in mortar Min. 8" Bearing 12 fix 12" ilumn Block ail Rebar Rebar 48 Bar Dia. Min. Overlap to Lintel Attachment NTS Provide #5 bar set In pre -cast ROOF l= L � N Scale : 1/2" = 1'-0" lintel into beam where length of L the opening calls for it. - /1 L t I i- O u I h d 11 e PT Buck ed per jamb Into Pilled ci 4" Pre -cast Sill ver angs a un ass of erwlse note on t Is sheet — Roof pitch at 4.12 unless otherwise noted on this sheet — Truss shop drawings to be provided by manufacturer — Any changes to this plan shall be submitted to the architect for approval in writing prior to starting construction. — ALL TRUSS TO TRUSS CONNECTIONS BY TRUSS MANUFACTURER — Architect to review Truss Shop Drawings Prior to construction for layout and uplift verification Poured Filled Coll Contractor to provide for Form Board Survey and to provide Form Board Survey to Truss Company prior to truss construction Trusses at 24" c.c. / see shop drawings big others Provide #5 bare with min. 48 bar diameters overlap in filled cell. Tie filled cell steel into continuous footer steel. Concrete Footing (see Tooter schedule for exact sizes) DETAIL AT WINDOW OPENING IN CBS WALL Scale: 1/2" = 1'-0" R-11 bi SINGLE PLY REAR GIRDER TRUSS VIA Nail 2' x 4" blocking to vert. leg of truss with IOd x 1.5 nails at 4' o.c. v Install Simpson MGT into wall using n 5/8' dia. threaded rod set min. 12" \ into wet beam and (22) IOd nails into truss TRUSS BLOCKING DETAIL AT GIRDER STRAPPING AT CENTER BEARING POINT 1/8" thick light textured stucco installed per ASTM C 924 over ASTM D type 2 paper backed wire lath nailed to substrate through one lager of ASTM D Type 2 felt paper using 8d nails. Substrate\ to be edges with COX Plywood nailed in 6" ads in field and edges with lad ring shank Wads into studs. Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11151.12 26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5' wood screws with self sealing washer at 12" o.c. max spacing over ASTM D (type 2) 30 lb felt underlagment installed with min. 4 side laps and 6" end laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach deck to trusses using attachment detail on this sheet �\ Additional Precast Lintel #5 bare ", 66EAR Lintel Length Bar Length Clear Span n u A Bars u u B Bars { 2'-10" 2'-8" I'-6" 2, none 3'-61, 3'-4" 2'-2" 2,#3 none era-OB/IT 8F8-IBAT 8P8-IB/2T Additional 4'-O" 3'-10" 2'-8" 2,a3 none #5 bars CLEAR cr a. `:;. 4'-b" 4'-4" 3'-2" 2,#3 none ne Row of "H" Block Above ."!'::;•'.�: yA 5'-4" 5'-2" 4'-O" 2,#3 none 1i ~ :: %t•`;! 5'-10" 5'-8" 4'-6" 2,44 none ...i Precast Lintel F'i.t;:f;' 9 6'-c' 6'-4" 5'-41, 2 u4 none i i Addtional i #5 bars 1'-6" 1'-O" 6'-2" 2,45 none SF16-115AT BFIL-IB/2T 8'-4" -O" 2,45 none NOTES: ALL reinforcing steel is grade 40. I. min. coverage of steel=1.5" 2. min. bearing required a ea. end=s' 3. standard for reinf. steel=ASTM A615 TYPICAL LINTEL SECTION ( PRECAST CONCRETE ) LINTEL SCHEDULE Mark Window or D Unit Width Lintel size Cast -Crete Specification Rows of 'H" Block Above Bottom Stssl S12f Top Stsel S12e Max Gravity Load (PLF) Max Uplift Load (PLF) Max Lateral Load (PLF) L22 2'-2' 3'-V 8F8-OB/IT 1 #5 30L9 15L9 1024 L31 2'-V 3'-8" 4'-0' BPS-OB/IT 1 #5 2541 13L3 163 L45 4'-5" 5'-10' 8F8-OB/IT 1 #5 1105 909 339 LBO 5'-0" 6'-L° 8F8-OBAT 1 #5 1238 835 121 L60 6'-8' 1'-6" 8P8-01SAT 1 #5 1011 121 534 L80 8'-O' 9'-4' 8FS-I5/2T 1 #5 2 #5 152 591 512 L90 9'-0' 10'-6' BPS-IS/2T I #5 2 #5 643 530 401 L90B 9'-0' 10'-6' 8FIL-IB/2T ONE 1 #5 2 #5 1533 1183 401 Li00 10'-0' II' 4" 8F8-IB/2T 1 #5 2 #5 582 494 452 WOOS 10'-0' II'-4' 8FI6-IB/2T ONE 1 #5 2 #5 1366 1028 452 LI20 12'-O" 13'-4' 8F8-IB/2T I #6 2 #6 411 428 324 LI20B 12'-O" 13'-4° SFIL-I8/2T ONE 1 #5 2 #5 1015 110 324 L140 14'-O" 16'-4' 8FI6-IS/2T ONE 1 #5 2 45 1250 LO9 259 LI60 IL'-O' IT-4' 8F8-IB/2T 1 #5 2 #5 300 192 194 LiLOB If'-O' IT-4' arit-1B/2T ONE 1 #6 2 #6 950 500 194 - ALL LINTELS SHALL BE MADE BY CAST-CRETE. - LINTELS SHALL BE FiLLED SOLiD WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 14'-O" LONG ARE TO BE PRESTRESSED. Simpson HETA 20 or equal hurrrcana anchor at each truss with (10) IOd x 1 1/2" nails - ( 24" o.c.) supporting Max. 18101bs. uplift Aluminum Drip Edge i Fascia 12" 2" x 6" S Kagean full o vent vinyl soffit installed using 1/8' din shank x 15" long gals. roaring nails with 3/8' die. head per product approval - see chart sheet #1 12' x 12' concrete column block filled with concrete and (2) #1 bars vert. tied -""— into lintels above thicken edge to 8"x8" with concrete and one #5 bar continuous BEYOND Top of Tooter IL" below finished floor m 4 �I Aluminum Drip Edge t Fascia Flash and Counter flash Nail ledger to gable end truss with (2) IOd I at each web hi -rib lath vertical wood c to provide .ration into 3/4' penetration members ceiling transition �--� ded using metal studs erify exact configuration .es R-30 Batts batts Drywall ceiling see tgprcal section Ceiling transitlon insulation Detail nts 5/8" thick light textured stucco on typical concrete Ijcr block construction Varies - see Ian m #5 bar vert. w/ 30" overlap at each filled cell Rear Patio/Slab to be flush with bottom of sliding door recess. Wood Base Brace Gable with 2" x 4" aft back naile Of top chords nails at each PRE-ENGIi > e 24"o.c. TYPICAL ( shop drawings by manufacturer ) �R-30 blown fiberglass in bottom chord of trusses -1/2" drywall with smooth finish Two rows of beam block filled with concrete _and (l) #5 bar Cont. 1n each row. Substitute precast lintel filled with concrete and (1) #5 bar cant. For bottom row over openings 1/2" drgwall over I" x furring strips at 16" o.c. with R4.1 fr-foil -insulation on typical 8" Block walls All drywall to be installed per FBC R102.3.1 and shall meet all pertaining ASTM codes. Mortar to be Type "M" oniy proportioned Der FBC R601.1 and Mortar joints shall comply with FBC R601.2.1. Provide Dur-O-Rock at all wet areas (ex, showers, tubs etc...) Fill cell with concrete and (1) #5 bar vert. (typical). Max. spacing shall not exceed 48" unless otherwise noted we foundation plan notes for spacing at openings 4" concrete slab with fibermesh OR 6"xb" #10/10 WWM on 6 mil Visqueen over clean compacted termite treated fill IIIIIII��—�—��� �T�TT`—�fT—I 51 1, �� FI illl IIII1 I� iiii IIhI ���� i�ll3 Typical Se)ctlon at Front Forth Scale : 1/2" = I'—C" �Iw Simpson HETA 20 Stra,p truss to wall using Simpson MGT with hurricane anchor at each truss 5/8 die. threaded rod with min 12" embedment „ ( 24F o.c.) supporting Max. Into beam (22) 10d either wet set or in epoxy with nails Into truss. Add blocking to 1810 lbs. uplift HETA20 S truss leg per detail on this sheet h0wo I am P MA NJ NO' N A"AA I r rAg M4 r9l MWA VAA� Pilo I NONE Mimi 6. Rill No 11 HETA 20 Simpson HETA 20 hurricane anchor at each truss ( 24" o.c.) supporting Max. 1810 lbs, uplift x pU L cv s, m � 4J O a a Act IJJ 2s ` N a O N U C -a U o0 E_ _ u N L Q H w •C',, PANEL "A„ Poles BR Load Wire Descnptien arc# circ# Description Wire Load BR Poles 1 20 1.2 kw #12 Refrigerator I Range #6 12.0 kw 50 2 1 20 L2 ko *12 Clothes Washer 3 1 20 1.5 kw $12 Kitchen S.A.C. 5 6 Dr sr #10 5.0 kw 30 2 1 20 1.5 Ito 912 Kitchen S.A.C- 1 S 1 20 #12 Bathroom Recepts 9 10 Air Cond eor $10 5.0 kw 30 2 - 1 20 1.2 kw #12 Dishwasher II 12 1 20 1.2 kw #12 Microwave 13 14 Air Handl #10 5.0 kw 30 2 1 15 - #14 General Lighting 15 It I 15 #14 General Lighting 11 IS WH $10 5.0 kw 25 2 - 1 15 - #14 General Lighting 19 20 1 15 814 General Lighting 21 22 GDO #12 O.SI Kill 20 1 - I IS 914 General Lighting 23 24 Spare Spam 25 26 Spare Spare 1 21 1 28 1 Spare Spare I 29 30 Spare PANEL "A" LOAD CALCULATION SHEET Load Description Qt . Watts Total(Watts) General._Lighting..(3, watts..aq,,ft.)......................... Small ppli Aancet(s) , Circul,,,,,,,,, ,,,,,,,,, ,,,,, Range ......... ......... ......... ......... .............. Refrigerator.................................................. Microwave Dish.. Washer ................................................. .Clothes..Wasbar , , . , ... , . Clothes ,. Dryer......... ....................................... Water Heater Garage. Door .Opener ....................................... 1135 3 5,205 2 1,500 3000 I 12.000 12.000 1 1,200 1,200 I 1,500 1,500 1 1200 1200 I 1,200 1,200 1 5 000 5.000 1 4,500 4,500 1 810 810 Total Watts 35415 First 10000 Watts e100% 1 10.000 10.000 Remainder 25.615 e40% 1 0 10,246 Electric Heat or A/C 10,000 e65% 1 10,000 10,000 Calculated Load Watts 30,246 Voltage 240 Calculated Wattage Divided by Voltage = Total Amps 126.02 Panel Size Required = 150 Ampsl Electrical S mbol Legend S Single Pole Switch ® Recessed Can Light S$ Double Pole Switch ® Egeball Recessed Ps Push Button Switch _0'Exhaust Fan Duplex Outlet Ceiling Mounted Light Special Receptacle ♦ Well Mounted Light Wa= ground fault circuitInt ro Light with Pull Chain (attic) ® Floor Duplex Outlet 0 Computer Connection Jack -cm- I Carbon Monoxide Detector Flood Light TQ Thermostat m Electrical Panel ® Central Vac 8 Electrical Meter ® Smoke Detector Ceiling fan ® Television Jack ® Telephone Jack ACoec A/C Disconnect ® I x 4 Florescent Light ® 2 x 4 Florescent Light ® Speaker Hook -Up FB = JUNCTION BOX TO SUPPORT A FAN O = THERMOSTAT LOCATION B/A = BALANCED AIR 1-2-19 FIELD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW (3) #I THHN Copper 2" PVC Schedule - 40 conduit 200a rated meter can 2" PVC ( FPL� schedule 80 2" rigid service FPL AI/1Cdisc. � 4 I ISO MCB PANEL rods ELECTRfCAL RiSER bonding pant - Contractor shall use AL-CU Landing lugs. - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction - Verify AIC/KIC Rating prior to ordering ELECTRIC NOTES: 42/0 AL SER Cable With #I Grnd 2" PVC Schedule 40 conduit sleeve into attic 200a rated meter can 2" PVC schedule r+r^N.r'1ry 2" rig A/C disc. L� ISO MCB PANEL I ground rods bonding pant _ ALTERNATE SERVICE ELECT. RISER NTS - Contractor shall use AL-CU Landing lugs. NTS - Contractor shall torque lugs I.A.W. manufacturers recommendations which shall be verified prior to construction t - Verify AiC/KIC Rating prior to ordering equipment Vent thru SoFFi�-- AiC SEE MANUAL "J" and Energg Calculation for Unit Info ° ° Mal CFM loxloxl MAST�T2 BEDRO M 139 CFM Ioxioxl B/A e1 e1 B/A d_�y32 KITCHEN 11 142 CFM 12x6x1 IS 150 Amp Panel A tiic A cip 1 with light L - - - - - 4"iG Steel Ballard See detail on this sheet GARAGE r-----------------1 I I I I I I I I I I I I I I I I I I I I I I I I MECHANICAL LAYOUT SCALE: 1/4" = 1'-0" Opt. PATIO/SLAB 163 CFM IOxlOx1 4101 12" FORCH I I Center R§gisters on telling Pan - I I I I G REIA R0(DIM 163 CFM IOxlOxl DINING ROOM THIRD BEDROOM 84 CFM iox6x6 0 56, laaa�i 215 CFM 121a:X1 SECOND BEDROOM I. Use copper wire only from panel to devices 15. Contractor shall guarantee all materials and workmanship 20. All equipment and panel sizes shall be verified before 2. Provide and wire all required smoke t Carbon free of defects for a period of not less than two gears from ordering. The contractor shall provide circuit routings to Monoxide detectors. the date of acceptance or certificate of occupancg, or one suit the Job conditions. 3. Contractor to verify location of electrical gear from closing sale of house. service and provider. Correction of defects shall be completed without additional 21, Furnish and install all fixtures as called for on the plans 4. ALL bath and kitchen receptacles to be GFCI protected. charge and shall include replacements or repair of any or as selected bg others. S. ALL exterior outlets to be WP/GFCI protected. other phase of installation that may have been damaged. 6. Recessed cans to be installed per NFPA requirements. 14, It is not the intent of these plans to show every minor detail 22• All raceways and pipes placed In or through ang concrete 1. Tamper resistant AFCI receptacles are required in of construction. The contractor shall furnish and install slab shall be spaced a minimum of three diameters of the ALL rooms. all items For a complete electrical system and provide all largest conduit or pipe From any other service. 8. A/C Return Air Balance Must comply w/ FBC RM1402 the requirements necessary for the equipment to be placed in 9. A(C Refrig�rg8 lines that are run thru slabs must be proper working order. 23. All exposed wire below 9'-1" shall be installed in metal EMT 10. sleeved in r'Yt: ALL A/C Equipment shall comply with energy calculation I1. All work shall be done in accordance with the N.E.C. and shall comply with all local codes and ordinances, and shall conduit. Dryer Braden t Braden AIA, FA II. All work shall be performed bg a licensed electrical meet all standard requirements of the local electric utility 24. Vents to be installed per FBC RMIS02 12. contractor, the completed st�stem shall be fully operative. Contractor for and telephone company. Architects - Planners shall pay all Fees, permits, testing, and blower 411 S.E. Coconut Avenue 13. inspections including testing where required. All work shall be coordinated with other trades to avoid 19. The electrical system shall be completely and effective)y by latest N.E.C. Tel : (112) 281-8258 grounded as required the edition of the interference with the progress of construction. Fax : (112) 281-8283 14. All required insurance shell be provided for protection 19. All material shall be new and shall bear underwriters E-mail: bradenala comcast.net against the public liability and property damage for the labels where applicable. duration of the work. Stuart. FL 34996 #AACOOOOS2 Exhaust Duct Thru Soffit_ 4" Exhaust Duct Thru Wall WP GFC Install oulet under disc. not shown or u1 claritg Vent thru Opt. PATIO/SLAB MASTER ,' \\ BEDROOM WP GFCI TY TV I� P(ORCH \ TV \ I \ I \ I __----- GREiAT ROOM OI O�Mmnowde Dee tsct.or Caaba GFCI C� I io -- I v I s CLOE I Ii 1\ ®rrI 171 �� II ®- - GFCI I DINING ROOM ®M 4FCI� Grp/ GF 5O FAN 1 IT 4N 4" " 13't2' / in I�111 WA111 _I p g 42"h GFC,11� - -x 54 Less - 2" ' 1 1 ath ltic ight 1 L---- I 410 Steel Ballard -� See detail on this sheet fi ull chain \ light in atticp, I50 4mp \ OPTIONAL PANEL Panel\ \LOCATION 42"h GFCI Garage `/jjJj Jl Door Opener r-----------------1 I I I I I I I I I I I I I I I I I I I I I I I I ELECTRICAL PLAN SCALE: 1/-4 = 1'-011 Attic Venting Calculations FBC 2309.1 Total Attic Space = 2,481 sq. ft. Venting Ratio I/150 = IL58 sq. ft. required 2 WP C A / Oner W`'CentThis er Post Light on ors Provide A Continuous Vented Soffit I Post Light with "- v? Photo cell e Wgn ie Building Corp. TH F- ROYALE Spanish Lakes St. Lucie County Florida oIF w IF Date Drawn Revisions 3-28-18 S-23-I8 Smoke detector revision GARAGE Drawn by: LEFT G.C.U. Checked by: D.R.B. Wire For Front most Light Sheet 1 OF 5 Comm 12-100 B