HomeMy WebLinkAboutProject Information-f'�- wdghtsoft- Project Summary Date: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN.,Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email:.QUICKCALCS(, 40L.COM Project• . • For: WYNNE DEVELOPMENT THE WINDSOR IMPACT, FT. PIERCE, FL Notes: 3 \) �eS� j Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 20795 Btuh Ducts 6191 Btuh Central vent (0 cfm) 0 Btuh (none)_ Humidification 0 Btuh Piping 0 Btuh Equipment load 26986 Btuh Infiltration Method . Construction quality Fireplaces Simplified Average 0 He tin Cooling Area (ffz) 1753 1753 Volume (ft') 16478 16478 Air changesmour 0.38 0.20 Equiv AVF (dm) 104 55 Heating Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536A" 030 AHRI ref 7914585 Efficiency Heating input. Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 36 OF Backup: 8.6 HSPF 34600 Btuh @ 47°F 0 1160 cfm 0.043 cfm/Btuh 0 in H2O Input ` 7 kW, Output = 23009 Btuh,100 AFUE 90 OF 75 OF 15 OF L 50 % 61 grAb Sensible Cooling Equipment Load Sizing Structure 16420 Btuh Ducts 9337 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturers data n Ratelswin multipolier 0.95 Equipmen sensi le load 24470 Btuh Latent Cooling Equipment Load Sizing Structure 2495 Btuh Ducts 2546 Btuh Central vent (0 cfm) 0 Btuh (none) . Equipment latent load 5041 Btuh Equipment Total Load (Sen+Lat) 29511 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536XO30 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent000ling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm. Airflowfactor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -Fia- welt ltsof — 2020-Jarr081622:01 Rigtt-SuteO Uriversal 20l91.9.0.07 RSU08101 Page 1 tsUrightsoftHVAQWYNNE-7HEWINDSOR-IMPACT.np.Calc=MJ8 Front Door 1hoes:N g - I - wr ghfisoft- RighW@ Woftheet Job- Entire House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 E)q)osedwall 180.6 ft 41.0 ft 3 Room height 9.4 It d 9.4 ft heat/oDol 4 5 Room dimensions Room area 1763.0 ftz 14.0 x 20.0 it 280.0 fF Ty Construction U-value Or HTM Area (ft-) Load Area (flF) Load number (BtuWF)' (BtuhV) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 G G 13A-4ocs AA-clom '4A5-2om 0.143 1270 0.770 n n - n ..4.00, 35.56 21.56 2.55 34.77 1931 649 15 38, 596 0 0 2386 533 816 1517 522 ' 730 66 0 0 66 0 0 263 0 0 167. 0 0 11 W 13A-4ocs 13A-4ocs 0.143 0.143 ne a 4.00 4.00 2.55 2.55 27 -. 141 27 100 106 400 68 255 0 0 0 0 0 0 0 A IA-c1om 11D0 13A-4ocs 1270 0.390 0.143 a e. se 35.56 10.92 4.00 87.06 : 1131 2.55 '. 20 21 27 1 21 27 711 229 106 1741 : 238 68 0 0 0 0 0 0 0, 0 0 0 0 0 W V►1 �G 13AAocs 0.143 ;: s 4.00 2.55 . 536 530 2121 1349 188 ' 188 . :753 479 ' 1A-clom . ' 1270 - : s 35M 34.77 6'. -"6 213 209 '0: 0 0 . .0 13A4ocs IA-clom 0.143 1270 w w 4.00 35.56 2.65 54.53 320 12 255 1 1022 415 649 636 132 12 108 1 432 416 275 636 G 1A-c1om 1270 w 35.56 54.53 12 1 427 654 12 1 427 654 4A5-2om 0.770. w 21.56 45.63 41 2 880 1862 0 0 0 0 P .120-0sw 0.091 - 2.55:. 128 254 254 647 326 0 0 .0 0 C 16A-30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 . 650 F. 22A-tpl 0.989 - 27.69 0.00 1753 181 5001 0 280 41 1135 ` 0 6 c) AED ex ursion 397 488 Envelope loss/gain 17583 15285 3676 3349 12 a) Infiltration 3211 905 729 205 b) Room ventilation 0 0 0 0 13 Internal gains: Oo upants @ 230 1 230 0 0 Appliano:s(olher 0 0 Subtotal (lines 6 to 13) 20795 16420 4405 3554 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20795 16420 4405 3554 15 Dud loads 30% 570/0 6191 9337 30%1 570/6 1312 2021 Total room load 26986 25757 5717 5575 Airrequ1red (dm) 1 1 1160 1160 2461 261 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 1 wvAgvvzScw$ ' 2020-Jar}081622:01 Mglt-SUte@ Uriversal 201919.0.07 RSU08101 Page 1 ACM ts\WdghtsoftWAC1WYNNE-THE WINDSOR=IMPACT.rcp Caic=MJ8 FrontDoorfaces: N wrightsofi° Right-M Worksheet J°a' Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM . 1 Room name WIC MASTER BATH 2 EVosedwall 0 it 9.0 ft 3 Room height 9.4 ft heatlwol 9.4 it heat/000l 4 5 Room dimensions Room area 7.0 x 9.0 it 63.0 fl= 7.0 x 9D it 63.0 fP Ty Construction U-value Or HTM Area (T) Load Area (its) Load number (BtuWF) (Btuhlff) or perimeter (it) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross NlP/S Heat Cool Gross N/P/S Heat Cool 6 G 13A4ocs 1Acldm 4A5-2om 0.143 1270 0.770: . n n' n ..4.00 . ' 35.56. 21.56 2.55 34.77 19.31 .0 0- 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0' :6 `0: 0. . ' ' '0 0 W 11 13A-4ocs 13AAocs 0.143 0:143 ne : e 4.00 4.00 2.55 2.55 0 0 0 . 0 0 0 0 0 0 0 0 . '0 0 0 0 .0 AA-c1om 11D0 13A-4ocs 1270 0.390: 0.143 a -. e; se 35.56 10.92 4.00 87.06 , 11.31 2.55 0 0 .0 0 0 0 0 0. 0 0 0 0 0 0 0 0 0 0 .0 0- 0 0 0 0 :. D W �1 13A-4ocs 0143 s 4.00 2.55 0.... 0 0 0 85 85 339 215 .'u•-G :IA-clom 1270 ' . s 35M 34.77 .0:. 0 0 0 0 0 - 0 0. VV��JJ 13AAocs 1Aclom 1A-clom 0.143 1270 1270 w w w 4.00 35.56 35.56 2.55 54.53 54.53 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I-G P 4A5-2om 12C-Osw 0.770 0.091 w 21.56 -2.55 45.63 1.28 0 0 0 0 0 0 0 0 0 -0 0 .0 0 0 0 0 C F 16A30md 2M.tpl, 0.032 0289 - - ado 27:65 2.32 0.00 63 63' 63 0 56 0 146 0 63, 63 63 9 56 .249 146 0 6 c) AED excursion -10 -28 Envelope lossIgain 56 136 644 334 12 a) Infiltration 0 0 160 45 b) Roomventilation 0 0 0 0 13 Internal gains: Oocupants@ 230 0 0 0 0 Appliances(lother 1 0 0 Subtotal (lines 6 to 13) 56 136 804 379 'Less extemalload 0 0 .0 0 Less transrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 804 379 15 Dud loads 1 30% 57% 17 77 30% 57%1 239 216 Total room load 73 214J-I 1044 595 Airrequired(cfrn) 3 10 45 27 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrigHtsoft^ 2020-Jan-081622:01 RightSdte@ Uriversal 201919.0.07 RSU08101 Page 2 tslWdghfsoftHVAC1WYNNE-THE,WINDSOR-IMPACT.nQ Calc=MJB FrontDoorfaces: N -9- Job: Right-M Worksheet Date: Entire House oat QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax.772-466.6796 Email: QUICKCALCS@AOL.COM 1 Room name IA BATH KrrCHEN 2 E)posedvmll 8.0 ft 0 ft 3 Room height 9A It heat1cool 9A It heaticool 4 5 Room dimensions Room area 7.0 x 8.0 It 56.0 fi? 1.0 x 172.0 It 172.0 ft2 Ty Construction U-value Or HTM Area Load Area : number (Btuhftt-°F) (Btuhlfl or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 1A-c1om `4A5.2om 0.143 1270'- 0.770 n h n 4.00 35.56 21.56 2.55 . 34:77 1931 - .0 0 .0 0 .0 . 0 0 0 0. 0 0 0 0 0 0 . 0 0 0 0" :0 0: 0 . 0 0 G 11 W 13AAacs 13AAois 0.143 0.143 ne -. a 4.00 4.00 2.55 2,55 0 0 0 .0 0 .0 0 0 0 0 0 0 0 0 0 0 1A,c1om _ 11DO 1270 •0.396 e: . e: 35.56 10.92 87:06 : 11.31 0 - 0 0 0 0 0 0 0 0' 0 0 :0 .0 0- 0 0 W 13AAocs 0.143 se 4.00 2.55' 0 0 0 0 0 0 0 0 yJ c ,G 13A-0ocs - " 1Ac1om 0.143 1270 .:;s s 4.06 35:56 2.55 34.77 75 6: 69 6 : 277 213 176 209 ' 0 -0 . 0 0 : 0 0 , 0 " 0 VVV���JJJ 13AAocs 1A-c1om IA-dom 0'143 1270 1270 w w w 4.00 35.56 35.66 2.55 54.53 54.53 0 0 0 0 0 0 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 A 0 �--G Imo_--GG P. 4A5-2om 12C-Osw. 0.770 0.091 w ,. -_ 21.56 5.5 45.63 128 0 0 0 0 0 0 0 0 0 . 75 0 75 0 192 0 96 C 16A-30md 0.032 - 0.90 2.32 56 56 50 130 172 172 154. 399 F . , 22A tpl: 0.989 -. - 27.69 : 0.00 56 ' " 8 222 0 172 0 0 " 0 6 c) AED excursion -38 -34 Envelope low/gain 762 477 346 462 12 a) Infiltration 142 40 0 0 b) Room ventilation: 0 0 0 0 13 Internal gains Occupants@ 230 0 0 0 0 Applianceslother 0 0 Subtolal (lines 6 to 13) 904 517 346 462 Less exlemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 904 517 346 462 15 DUdload5 30% 57% 269 294 300/a 57%1 103 263 Total room load 1 1174 811 449 725 Airrequired (clm) 50 37 19 33 Calculations awroved WACCAto meet all reoulrements of Manual J 8th Ed. -rwwrligtstCs 2020-Jan-081622:01 /1CCA FZglt-Sute@ Uriversal 20l9 l9.0.07 RSU081 O1 _ Page 3 tslWdgttsotWAd1WYNNE-THEWINDSOR4MPACT.np CaIc=W8 FroMDoorfaces: N - -,idght Right-J® Worksheet Job. Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE UN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name BATH BEDROOM2 2 Exposedwall 5A ft 42.6 It 3 Room height 9.4 ft heat/000l 9.4 ft heaftool 4 5 Room dimensions Room area 9.0 x 5D It 45.0 T . 1.0 x 204.0 ft 204.0 1F Ty Construction U-value Or HTM Area Load s number (BtuhlfF-°F) (Btuh/f�) or perimeter r (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs IA-c1om 4A5-2om 0.143 1270 0.770. rr n n 4.00 35.56: 21.56 2.55 . 34.77 19.31 47 0 0 47 0 0 188 0 0 120 0 0 132 0 0 132 0 0 527 0 0. ' 335 0 0. W 11 13A-4ocs 13A-4ocs 0.143 0.143 ne . e. 4.00 4.00 2.55 -.2.55 0 0 0 0 0 0 0 0 27 85 27 65 106 259 68 164: AA-c1om :11D0 13AAocs Y270 0.390 0.143 a a se 35.56 10.92 4.00 87.06 ' 11.31 2.55 - 0 0- 0 0 0 0 0 0 0 0 0 0 i 20 0 27 1 0 27 711 0 106 1741 0 68 D W �G 13AAocs -1A-c1om 0.143 1270 . s ; , s- 4.00 .35.56 2.56 34.77 - 0 ' - 0 0 . 0 0 0 .0' 0 132 - 0 132 0 527 0- ;. 335 0 yyll 13AAocs IA-c1om 1A-c1om 4A5-2om 12C-0sw 0.143 1270 1270 0.770 OD91 w w w w 4.00 35.56 35.56 21.56 2.55 2.55 54.53 54.53 45.63 1.28 0 0 0 0 .0 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ►-G I�-GG P- C F 16A30md 22A:tpl- 0.032 0.989, - - 0.90 27.69 2.32 0.00 45 45 45 5 40 138 104 0 204 204 204 43 183 '1179 473 0 6 c)AEDexcursion -17 -99 Envelope loss!gain 367 207 3599 3085 12 a) Infiltration 89 25 758 214 b) Room ventilation' ' 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances(other 0 0 Subtotal (lines 6 to 13) 456 232 4357. 3299 LesseAemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 456 232 4357 3299 15 Ductloads 30% 57% 136 132 30% 570 1297 1876 Total room load F 592 364 1 5654 5175 Air required (dm) 25 16 243 233 Calculations approved byACCAto meet all regUirernents of Manual J 8th Ed. -Fid- wraglatsol 2020-Jan-081622:01 ACCA 1.,, -Sute@)Uriversal 20l9 l9.0.07 RSU08101 Page 4 .ts\WrigMsoftHVAC\WYNNE-THEWINDSOR-IMPACTn{� CaIc=MJB FrontDoorfaces: N - wrightloftm Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By- 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name ENTRY LAUNDRY 2 Exposed vudll 6D ft 6D It 3 Room height 9A It heat/cool 9A ft heat/cool 4 5 Room dimensions Room area ID x 92.0 ft 92.0 ft2 7D x 6D It 42D fe Ty Construction number, U-value (BlrrhliF-°F) Or HTM (BluhM2) Area (ft-) or perimeter (ft) Load (Btuh) Area (T) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6I- C '13A-4ocs 1A�1om `05-26m 0.1.43 1270 0:770 n ' n' : n 4.00. 35.56 21.56 2..55 34.77 `19.31 0 0 .0 0 0 0 0 0 0 0. 0 0 0 0' 0 0 '0 0 6 0 0 0. . ' 0 : 0. -G W 11 13A.4o s 13A-4ocs - 0143 0143 ne . e 4.00 4.00 2.55 2.55 0 '' . 56 0 . ' 35 0 142 0 90 0 0 0 . 0 0 0 0 .0 1Ac1om '11DO ' 13A4ocs 1270 0.990 0.143 `e e. se 35.56 10.92 4.00 87.06 , - . 11.31 2.55 0 21 0 0_ 21 0 0- 2.29 0 0 ' 238 0 0 0 0 0. 0 0 0 0 0 0 0 0 D W :'f-. G. 13AA6cs "1A,o1orh : - 13A-4ocs 1A-clom 1A-clom 4A5-2om 12C4sw 16A30md 22A-fpl . 0.143 1270 0.143 1270 1270 0.770 0.091 0.032. 0.989 s' '- s :. w w w w ` - 4:00 35.56 4.00 35.56 35.56 21.56 255 0.90 27.69 2.55 : "34.77 2.55 54.53 54.53 45.63 128 2.32 0.00 0 :0 0 0 0 0 , 113 92 92: 0 ; 0 0 0 0 0 113 92 6 0 0 0 0 0 0 '287 82 166 -0' 0 0 0 0 0 145 213 0 56 .0 0 0 0 0 .66 42 42 ' : 56 .0 0 0 0 0 66 42 6 .226 0 0 0 0 0 168 38 166 '144 ; .. 0 0 0 0 0 ' U 97 . ' 0 G P . C F r 6 c) AED excursion -49 -24 Envelope loss/gain 907 637 597 301 12 a) Infiltration b) Room ventilation 107 0 30 0 107 0 30 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoadother 0 0 Subtotal (lines 6 to' 13) 1014 667 704. 331 14 15 Less external load Less transfer Redistribution Subtotal Ductloads 30% 57% 0 0 0 1014 302 0 0 0 667 379 30% 57% 0 0 0 704 210 0 . 0 0 331 188 Total room load Airrequired (cfm) 1316 57 1047 47 914 39 520 23 Calculations approved WACCA to meet all requirements of Manual J 8th Ed. �rvr�gl� o� t� 2020-Jarr081622.V fZightSuteC� Universal 201919.0.07 RSU08101 Page 5 tslWrigffsotWAC1WYNNE-THEWINDSOR-IMPACT.np Calc='MJ8 FroMDoor taces: N F wrightSoft° Right-J® Worksheet °ateDat Entire House By. QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name GREAT/DINING Room7 2 3 .E)posedwall Room height 50.0 ft 9A ft heat/cool 13.0 ft 9.4 ft heat(cool 4 5 Room dimensions Room area 1.0 x 567.0 ft 567.0 ft2 13D x 13.0 ft 169.0 ftz Ty Construction number U-value (BtuhllF--°F) Or HTM (Btuhg) Area r (ft) or perimeter (Btuh) s or perimeter (ft) Load (Btuh) Heat Cool Gross NOS Heat Cool Gross N/P/S Heat Cool 6 VL13A4ocs 1A-c16m `4A5 tom 0.143 1"270 0.770 n n n 4.00 35.56 121.56 2.65 34.77 19:31 282 " 0 38 244 0 0 978 0 815 622 0 730 122 15 0 107 0 0 429 533 0 273 "•" 522 0 G 11 W Vp 13A4ocs 13A4ocs 0.143 m-43 ne a 4.o6 4.00' 2.55 2.55 0 " 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 •0 1Aclom 11D0 ' 13A-4ocs 13A4ots ` Xclom " 1A-c1om 1A-c1am 1270 0.390. 0.143 0:143: 1270 0.143 1270 1270 "e a:. se s . s," w w w 35.66 10.92 4.00 4.00. 35.56 4.00 35.56 35.56 8Z.06 " 11.31 2.55 255 34.77 2.55 54.53 54.53 0 0 0 0 0 188 0 0 0 0 0 _ 0 - 0 147 0 0 0 0 0 0 0 589 0 0 0 0 0 ...0 0 375 0 0 0 0 0 0 0" 0 0 0 0 0 0 0' 0 0 0 0 0 0. 0 0.• '0- 0 0 0 0 0 0 0. 0 0 0 0 . W :L-�-G J�:13A4ocs G 4A5.2om .107,Osw .16A30md 224l~ 0.770 0.091 0.032 0.989 . w _ - 21.56 2.55, 0.90 27.69 45.63 _ 128 2.32 0.00 41 0 567 567' 2 , 0 567 50 880 0 508 1385 1862 0 1315 0 0 0 169 169 0 0 169 13 0 0 151 360 0 0 392 0 P. " C F. 6 c) AED excursion 307 -100 Envelope loss/gain 5154 5210 1474 1086 12 a) Infiltration 889 251 231 65 b) Room ventilation 0 .0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Appliances(other 0 0 Subtotal (lines 6 to 13) 6043 5461 1705 1381 Less e&mal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 .Subtotal 6043 5461 1705 1381 15 Dud loads 30% 57% 1799 3105 30% 57% 508 785 Total room load 7843 8566 2213 2167 Air required (dm) 337 386 95 98 Calculations aDDroved WACCAto meet all reouirements of Manual J 8th Ed. - - wrigitittsofit' 2020-Jarf0616:22:01 .9 Cti Right-Sute®Uriversa120191,9.0.07 RSU08101 Page 6 tslWdghtsoftFNAC1WYNNE-THEWINDSOR-IMPACT.nQ Calc=MJ8 Front Doorfaces:N . murightsoft® Duct System Summary Entire House QUICK CALCS; INC. 317 St LUCIE LN., Fr. PIERCE, FL 34946.Phons:77246.6.6799 Fax:772-466-6796 Email: QUICKCALCS AOL.COM For. WYNNE DEVELOPMENT THE WINDSOR IMPACT, FT. PIERCE, FL Job: Date: By. Heating Cooling Bdemal-static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Availablestatic pressure 0. in H2O 0 in H2O Supply/ return available pressure 0.000 /0.600 in H2O 0.000 /0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual airflow 1160 cfm 1160 Cftn Total effective length (TEL) 0 ft SupplyDetail Table Name Design (13tuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mal Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt' 0 0 BEDROOM C 2788 123 126 0 0 Ox O ShMt 0 0 BEDROOM 2 h 2587 122 117 0 0 Ox 0 ShMt 0 0 BEDROOM2-A h 2587 122 117 0 0 OxO ShMt 0 0 BEDROOM•A C 2788 123 126 0 0 Ox 0 ShMt 0 0 ENTRY. h 1047 57 47 0 0 Ox 0 ShMt 0 0 GREAT/DINING C 2855 112 129 0 0 Ox 0 ShMt 0 0 GREAT/DINING-A ' C 2855 112 129 0 0 Ox 0 ShMt 0 0 GREAT/DINING-B c 2855 112 129 0 0 Ox 0 ShMt 0 0 KITCHEN c 725 19 33 0 0 OX 0 ShMt 0 0 LAUNDRY h 520 39 23 0 0 Ox 0 ShMt 0 0 M. BATH h 811 50 37 0 0 Ox 0 ShMt 0 0 MASTER BATH h 595 45 27 0 0 Ox 0 ShMt 0 0 Room7 C 2167 95 98 0 0 OX 0 ShMt 0 0 wlc C 214 3 10 I 0 1 0 Ox 0 I ShMt 1 0 1 0 Return Branch Detail Table Name Grille Size (in) Htg (Crm) Clg (Cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 ShMt 40- 2020-Jarr081622:02 W.r 9Riglt-Sate® Udversa1201919.0.07 RSU08101 Page 1 ...tslWrigNsoftHVAQWYNNE-THEWINDSOR-IMPACTatp Calc='MJ8 Front Door faces: N