Loading...
HomeMy WebLinkAboutTrussA=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. I HOUND BE QILIIEDIDEn AND SUCGESSEUILY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR Tf AT MODEL. Tf 'USSES FOR T�iE FIRST MODEL ® ARRAN13E WITH CRA NE E OPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24' fN LENGTH Xl�AIW$;il A Do not r-tand on trusses until they are braced per SCSI & properly nailed to straps & hangers C L� SI AGING NOT19' 9w E I I I I 1 r ALL TRU55E5 ARE TO DE SET AT 2' O: ON CENTER EXCEPT AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A A DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less 30' to 60' Span so degrees Spree er Bar or less —._ 1 /2 _ _10 7.9 rox 2/3 to,—� 'ag Line spcn cpprox Line 1/2 of span REFER 10 BCSI REFER TO BCSI Fict uss must be set this way if crone used Truss must be set this way m crane used u our truss a not motnn. This Is an example, truss may not match. es is on exooerc y m Y ,one operator sets Truss this way Insist crane operator sets truss this way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses A are installed, A Al R HAN p1_�F2 NOTE UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. For Truss to Truss Connections see hanger/connector schedule in engineering package. 'Nails must be as shown. Guide tabs o Dome angle nails. 11 SEAT PLATES BY CHAMBERS F LWATED M DIMENSIONED ON uYWT coeAEaTAcxs m" �9 o Gwt.— A8a zr ocl U ALMS 1 GWNuA DN,r CORNER DETAIL OVERHANGS NOT SHOWN FOR CLARITY upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8' TYPICAL END DETAIL 12 4.00 Lon - 12 2.00 i� r may® ®! MINI 1III kA5 A5 A5 Al J��"`181020 1 r IF 1 I� f N i t 0 e- i I ,IL-- upset=1/4" heel=3 15/16" INDICATES LOAD BEARING PLUMB CUT END REQUIRED BY TRUSSES SUPPLIED BY BUILDER 2 x 4 Top Chord AT A HEIGHT OF 8'-0" WALL HEIGHT 8' ABOVE FINISHED FLOOR END DETAIL: TYPICAL VAULT ® ■ I y I��® lk�I„ e,, / '-' i�1F�1I1 I%,i/I%„li/„I%,i/ ii�4rAIz,/,I''li�%IWl 14'-4" 64N 14'-4w i' CLOUTSED AREAS ARE OFSPECIAL MST PORCH RIGHT 01, CHECKEDCONCERN CAREFULLY &UMAY E e INDICATE DEVIATION FROM PLANS.,, FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED r The legal description of the property where the trusses will be Installed is: ,The undersigned acknowledges and agrees: 1: Trusses will be made In strict accordance with this truss placement diagram layout, which is the We authority for determiningsuccessful fabrication of the trusses. 2.All dimensions In this layout have been ven8ed by the undersigned. .3, Unless written notice Is provided by certlfled mall to Chambers Truss within ten 00) days of delivery the undersigned agrees that no backchaiges will be allowed, In the event such written notice le lumlahed Chambers Truss shall have three (3) busei1nness days In which 'to begin repalm requlred, or to substitute other Wssea, al Chambere opti3°n.' 4. The undersigned acknowledges receipt of "BCSI 1-03" summary sheet by TPI & WTCA, 5. Delivery Is to Job site. It Is the buyeta'responelbility to make the job site suitable for delivery. Chambers Truss has the cote authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will be responsible for dump delivery only. The buyer Is responsible for additional delivery expenses If Chambers Truss has to redellver because job site Is not prepared for delivery or buyer Is not prepared for delivery of trusses, Buyer Is responsible to Chambers Truss for towing costs due to site conditions, 8. Price as shown Iq paragraph 7 below Is subject to change If any changes are, made 16 this layout A $50 per hour fee for revisions maybe charged by Chambers Truss. .7: This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or ti n4; agreement a reasonable price. invoice will be made on delivery and paid within terms of not on delivery. Invoice may, be made at scheduled date of. delivery If buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambere.TNss reasonable sttpmey's fee for collections In event of payment not timely made. 1-12 % per month senlce charge will be added for all sums not paid within terms. . 8. Signature or Initials anywhere on this sheet conalRues, agreement to all terms herein, S. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Trues by any entity receiving material and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment for material be made by the recipient. 10. In the event of any Iltlgatipn concerning this agreement, the Items furnished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will be Saint Write County, Florida. 11. Design responsibilities are per "National Standard And RecommendedGuidelinesOn Rasp onclIIIIII s For Construction Using Metal Plate Connected Wood Trusses ANStgVWTCA 4 - 2002 DATED .�..� . ,SIGNED FOR TITLE Aspreaderbarmaybe regL#mIl per"BCSI 1-orto pleYesit injtsy& damage. Multiple ply trusses must be fastened tog6thar per engineering before they are set, failure to do so can result In roof collapse. Temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. 'Study the contents of the Information packet Included on delivery before setting trusses. Thwas must besetand braced per design to prevorit injury & damage. Trusses must be set plumb and square Do riot set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES i CHAMBERS TRUSS INC 3105 Oleander Avenue Fort Plerceir Florida 34982-6423 800-551-5932 ' Fort Pierce 772.465-2012 Fax 772-465-8711 Vero Beach 772-US-2012 Stuart 772-286-3302 ' The Architect's or Architect's rep .antativra's shop drawing approval is NUTa "double check" of the contractor. The contractor shall remainresponsible for checking field measurements and other construction criteria, Architect's approval covers general roof shape, review of truss strapping, and loading on structure from gravity and uplift loads and their re tive locations. Approvetl 8 92.0/93.2 MITEK 4.8ate: t'F'f1rldenA.1.A P. DESIGN CR. County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 Roofing Material Shingle or Shake Loading in PSF Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 165mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 15'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 R.D.L =Restrainin Dead Load C.B.=Continuous Brawn Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Designer and/or Engineer of Record. Chambers Truss Inc. Drawing Name: M11392 Scale: 1 /4 = 1' 82 total trusses, 15 different trusses. MI 4: RLC ACAD: RLC Reviewed By: Date:10107/15 Revised:03/21/18 I FOR Revised: 3/b5t2 0 6'-4" 1 14'-4 ---- C , WYNNE BUILDING CORP. DESCRIPTION: PORCH LEFT WINDSOR PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE % Qda 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M11392 T Sx$ MiTek' RE: M11392 MiTek USA, Inc. THE WINDSOR 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: Wynne Dev Corp Project Name: M11392 Lot/Block: Model: THE WINDSOR Address: unknown Subdivision: City: St. Lucie County State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T1978180 2 T19781804 A Al 9/23/2020 9/23/2020 FILE 3 T19781805 A2 9/23/2020 4 T19781806 A3 9/23/2020 5 T19781807 A4 9/23/2020 6 T19781808 A5 9/23/2020 7 T19781809 ATA 9/23/2020 8 T19781810 B 9/23/2020 9 T19781811 BHA 9/23/2020 111 T19781813 JJ1 9/23/2020 REVIEWED FOR 12 T1978181 13 T19781815 J3 J5 9/23/2020 9/23/2020 CODE COMPLIANCE 14 T19781816 J7 9/23/2020 ST. L1i•D CIE COUNTY 15 T19781817 KJ7 9/23/2020 ��fl ��++ occ This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced. above have been prepared by MiTek USA, Inc under my direct supervision ,.0 %J 111 t 11111 based on the parameters provided by Chambers Truss. ,��%O0P?•; 4 • Abe �i�� Truss Engineers Name: Albani, Thomas My licensenrenewal date for the state of Florida is February 28, 2021. ;��,`�j'•.��G E N S�. 92/''•r Florida COA: 6634 No 39380 r IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. STATE. OF : 44J i OR\ JO N A- \N Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 September 23, 2020 1 of 1 Albani, Thomas Job Truss Type Oty Ply THEWINDSORT19781803 THruPss M11392 A 1 1 Job Reference (optional) Gnamoers I russ, Inc., V0rE rlerce, t-L 6.z41) S Mar v zuzu MI I eK mausmeS, Inc. I Lie Mar z4 1z:b4:U r zuzu rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXjH_ 1-0-0 6 10-14 9 0-0 14-11-0 20-2-13 26-0-0 28 1-2 35-0-0 6-0- -0-0 6 10-14 Nil 5-11-0 5-3-13 5 9-3 2-1-2 6-10-14 -0-0 4.00 12 4x8 = 2x3 II 2x3 4 26 5 3x6 = 4x4 = 4x8 = 2x3 6 7 27 8 9 Scale = 1:60.5 17 16 15 14 13 12 3x4 — 3x4 = 3x6 — 6x8 = 3z4 = 3x6 — 3x4 = 3x5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 Vert(LL) 0.42 12-23 >572 240 TCDL 7.0 Lumber DOL 1.25 BC 0.47 Vert(CT) 0.37 12-23 >659 180 BCLL 0.0 Rep Stress Incr YES WB 0.94 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0 Max Horz 2=-97(LC 10) Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12) Max Grav 2=467(LC 17). 15=1 596(LC 1),10=685(LC 22) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-639/108, 3-4=-396/0, 4-5=-967/776, 5-7=-967/776, 7-8=454/938, 8-9=-1009/1884, 9-10=-1265/2154 BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-15861938, 10-12=-1971/1174 WEBS 3-17=-372/461, 4-17= 272/451, 4-15=1087/1002, 5-15=-336/386, 7-14=-766/399, 8-14=-580/997, 8-12=-958/447, 9-12=-358/600, 7-15=-1329/2190 PLATES GRIP MT20 244/190 Weight: 161 lb FT = 20% Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 4-5-1 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at joint 15 and 799 lb uplift at joint 10. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 11834 8904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Qualify Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Sarefylnrormadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply THE WINDSOR T19781804 M11392 Al SPECIAL 1 1 Jab Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:08 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of7iF3blfgtYOgDv7Us9cGoCh5CAjz5KiVwkOzzXjGz �1-0-0 8-6-0 11-0-0 14-9-0 19-8-14 24-0-0 27-4-7 35-0-0 y-0-0' 8-6-0 2-6-0 3-9,0 4-11-14 4.3.2 3-0-7 7-7-9 -0-0 4.00 12 3x6 = 9Y'A A 5x6 = 2x3 11 21 5 3x4 = 6 22 13 12 3x5 = 5x8 MT18HS = 2.00 12 5x8 MT18HS = 3x12 Scale = 1:61.3 10-0-0 149-0 24-6-8 35-0-0 , 10-0-0 4-9-0 9-9-8 10-5-8 Plate Offsets (X,Y)— [2:0-0-2,Edge], [7:0-4-0,0-2-3], [9:0-1-15,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.63 Vert(LL) 0.76 11-12 >563 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -1.21 11-12 >348 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.77 Horz(CT) 0.35 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 155 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1),9=1349(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=3022/2080, 5-6=-3022/2080, 6-7=-4643/2994, 7-8=-5324/3364, 8-9=-5751/3700 BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478 WEBS 3-13=425/410, 4-13=354/571, 4-12=362/617, 5-12=-269/279, 6-12=-1034/712, 6-11=-373/892, 7-11=-897/1523, 8-11=-404/435 Structural wood sheathing directly applied or 2-7-7 oc pudins. Rigid ceiling directly applied or 2-2-0 oc bracing. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 9. This item has been electronically signed and sealed by Alban!, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 6/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦ is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781805 M11392 A2 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:09 2020 Page 1 ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-HsZ4SPcOQ8?P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy 1-0-0 8-6-0 13-0-0 14-0 2 9-2-0-0 27-4-7 35-0-0 6-0- 0-0 8-6-0 46 0 1-9-0 7-3-0 5-0-7 7-7-9 -0-0 Scale=1:61.3 3x6 = 4.00 12 10-M 30 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017frP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=136(LC 11) Max Uplift 2=-825(LC 12), 8=-825(LC 12) Max Grav 2=1349(LC 1), 8=1349(LC 1) 5x6 = 3x4 = 4 21 5 12 5x8 = 2.00 12 5x8 = 22 6 302 zz CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TC 0.66 Vert(LL) 0.72 10 >585 240 MT20 244/190 BC 0.95 Vert(CT)-0.9410-19 >447 180 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 8 n/a n/a Matrix -MS Weight: 160 lb FT = 20%, BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-15 0o puriins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=-3379/2225, 6-7=-5242/3250, 7-8=-5759/3665 BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=-1990/3441, 8-10=-3410/5485 WEBS 3-13=-420/418, 4-13=-427/688, 4-12=-337/551, 5-12=-777/605, 5-11=-465/925, 6-11=-391/277, 6-10=-1318/2268, 7-10=-503/530 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd, Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall p q�• building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦ Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781806 M11392 A3 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:10 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgIdOBS7Gd7NIFvvehhuYXvu2BsndgpPr4RzXjGx 1-0-0 8-6-0 15 0-0 20-0-0 24 1 27-4-7 35-0-0 $6-0 q o 8-6-0 16 0 10 4-6-8 2-9-15 7-7-9 0-0 3x5 = 4.00 12 5x6 = 4x5 = 14 13 "'" 2x3 11 5x6 = 2.00 12 Scale = 1:62.3 3x12 zz rn 0 — r 0 8-6-0 14-9-0 20-0-0 24-6-8 35-0-0 8-6-0 6-3-0 5 3-0 4-6-8 10-5.8 Plate Offsets (X,Y)— [2:0-1-6,Edge), [3:0-3-0,Edge), [8:0-3-0,0-3-4), [9:0-1-15,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.60 Vert(LL) 0.73 11 >572 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.97 11-20 >432 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.83 Horz(CT) 0.36 9 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at micipt 7-12 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-155(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1), 9=1349(LC 1) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=-5320/3257, 8-9=-5720/3554 BOT CHORD 2-14=-1817/3048,13-14=-1817/3048,12-13=-1258/2274,11-12=-2935/5103, 9-11=-3302/5445 WEBS 4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-2727/1643, 7-11 =-1 072/1939, 8-11=-390/391 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for This item has been members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. electronically signed and 4) All plates are MT20 plates unless otherwise indicated. sealed by Albani, Thomas, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' using a Digital Signature. 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed Copies Of this will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify document are not considered capacity of bearing surface. signed and sealed and the 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signature must be verified joint 9. on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE. PAGE MII-7473 rev. 51IM020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply �THEWINDSOR T19781807 M11392 A4 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:112020 �P 0 3x5 = 8-6-0 6-3-0 ' 2-3-0 4.00 12 5x6 = 4x6 = 2.3 16 15 6x10 = 2x3 11 5x8 = 2.00 12 3x12 Scale = 1:62.3 I� 2 0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.80 13 >528 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -1.05 13 >400 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.98 Horz(CT) 0.39 11 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 172 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 WEBS REACTIONS. (size) 2=0-8-0, 11=0-8-0 Max Horz 2=-175(LC 10) Max Uplift 2=-825(LC 12), 11=-825(LC 12) Max Grav 2=1349(LC 1), 11 =1349(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=-2399/1639, 6-7=-2217/1501, 7-8=-2380/1519, 8-10=-5361/3228, 10-11=5716/3480 BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154, 11-13=-3232/5441 WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604, 6-15=-315/409,8-14=-3146/1901,8-13=-1034/1946,10-13=-343/333 Structural wood sheathing directly applied or 2-6-14 oc purlins. Rigid ceiling directly applied or 2-2-0 oc bracing. 1 Row at midpt 8-14 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip D0L=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 11. This item has been electronically signed and sealed by Albani, .Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall MIM building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS117P11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781808 M11392 A5 SPECIAL 16 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:13 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6tw1 SLJKWOV6vFOEp3rneVhmzXjGu n1-0-0 8-6-0 14-9-0 17-6-0 24-6-8 i 27�-7 35-M -0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0 Scale=1:60.3 5x8 MT18HS 11 4.00 12 14 13 3x5 = 2x3 II 5x10 = 2.00 12 3x12 1 0 8-6-0 14-9-0 24.6.8 35-0-0 8-6-0 6-3-0 9-9-8 10-5-8 Plate Offsets (X,Y)— [2:0-1-6,Edge), [8:0-3-0,Edge), [10:0-1-15 Edge) LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) Vclefi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.81 Vert(LL) 0.80 12-13 >526 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(CT) -1.28 12-13 >329 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.74 Horz(CT) 0.36 10 n/a n/a BCDL 10.0 Code FBC2017rrPI2014 Matrix -MS Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 31 `Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. 14,8-11: 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. BOT CHORD 2x4 SP M 30 WEBS 1 Row at midpt 6-12 WEBS 2x4 SP No.3 "Except' 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) Max Grav 2=1349(LC 1), 10=1349(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3247/2112, 3-5=2449/1679, 5-6=-2397/1763, 6-7=5452/3624, 7-9=-5398/3482, 9-10=-5732/3689 BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=-3431/5459 WEBS 3-14=0/303, 3-13=-861/619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526, 7-12=-323/388,9-12=-321/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. This item has been 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to electronically signed and 21-0-0, Intefior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip sealed by Albani, Thomas, PE DOL=1.60 using a Digital Signature. 3) All plates are MT20 plates unless otherwise indicated. Printed copies Of this 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide document are not considered will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Signed and Sealed and the 6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify signature must be verified capacity of bearing surface. 7) Provide mechanical connection (by others) of -truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at on any electronic copies. joint 10. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MrrekO connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Satetyintormation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781809 M11392 ATA COMMON 5 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:14 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-dpMzW7gWEgdi6lg3UkzarX2EkWJA7jM4RN3DCzXjGt �1-0-0, 8-4-0 12-11-0 17-6-0 22-1-0 26 8.0 35-0-0 46-0-q 0-0 8.4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0 �1 O 4.00 12 4x5 = Scale=1:59.5 17 '" 15 "" '"' 14 "" 12 3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 = 3x8 = 4x6 = 1 N I� 8-4-0 12-11-0 22-1-0 26 8-0 35-0-0 , 8-4-0 4-7-0 9-2-0 4-7-0 840 Plate Offsets (X Y)— [2:0-0-2 Edge] [10:0-0-2 Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.59 Vert(LL) 0.33 14-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.64 14-15 >652 180 BCLL 0.0 Rep Stress Incr YES WB 0.59 Horz(CT) 0.13 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 166 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-775(LC 12), 10=-775(LC 12) Max Grav 2=1399(LC 1), 10=1399(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=-2807/1637, 9-10=-3404/1963 BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188, 10-12=-1739/3188 WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip This item has been DOL=1.60 3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. electronically signed and 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Sealed by Albani, Thomas, PE 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members, with BCDL = 10.Opsf. Printed copies of this p 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift at joint 2 and 775 lb uplift at joint 10. document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall MiTek' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPi1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781810 M11392 B COMMON 2 1 Job Reference (optional) Chambers Truss, Inc., Fart Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:15 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-50wLjSh87_IZuFF2SVpOlbSRwk4sA4MJ57cmfzX Gs i1 0 0 8-3-5 14:.0 17-6-0 21-0-0 26-8-11 35-0-0 a6-0 q h-0-0' 8-3-5 5 8-11 3-6-0 3-0-0 5 8-11 8-3-5 0-0 3x4 = 4.00 12 3x6 = 17 — 15 14 12 2x3 II 3x6 = 3x4 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC20177TPI2014 3x4 = 3x6 = 2x3 II CSI. DEFL. in (loc) Udefl Ud TC 0.34 Vert(LL) -0.11 14-15 >766 240 BC 0.38 Vert(CT) -0.24 17-20 >715 180 WB 0.63 Horz(CT) 0.03 10 file n/a Matrix -MS Scale=1:59.3 3x4 = PLATES GRIP MT20 244/190 Weight: 149 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 10) Max Uplift All uplift 100 lb or less at joint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC 12) Max Grav All reactions 250 lb or less at joint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-945/572, 5-6=181/256, 6-7=-181/258, 9-10=-945/574 BOT CHORD 2-17=407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858 WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592, 9-12=-5/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; save=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10. ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1011.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 MiTek' 6904 Parke East Blvd. Tampa, FL 36610 1 � 0 Job Truss Truss Type Oly Ply THE WINDSOR T19781811 M11392 BHA 80STON HIP 1 1 Job Reference o ti0nal Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:17 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM 1 K3EfmPcjgXzXjGq 15-M 21.64) 1-0-0 7.0-0 9-6-0 ll-6-0 13.6.0 1 17-6-0 19-6-0 21-0-0 23.6.0 25-6-0 28-0-0 35.0-0 6-0-0 -0-0 7-0-0 2-6-0 2-0-0 2-0-0 0-0 1-6-0 2-0-0 2-0-0 1-6-0 0-6 2-0-0 2-0-0 2-6-0 7-0-0 -0-0 Scale=1:62.4 TOP CHORD MUST BE BRACED BY END JACKS, ROOF DIAPHRAGM, OR PROPERLY CONNECTS 4.00 12 4x4 = PURLINS AS SPECIFIED. 56 12 3x6 55 9 548 5x12 =53 4 6 3 11 52 N1 2 aj 35 42 43 34 44 33 45 3x6 = 6x8 = 3x4 = 57 15 58 17 59 2I 60 22 3x6 x6 = 3x4 24151 5xl2 26 16 19 1 23 (527 63 14 n 28 29 n N 46 47 48 32 49 31 50 51 30 6x8 = 3x6 = 3x4 = 7-0-0 14-0.0 21-0-0 28-0-0 35.0-0 7-0-0 7-0-0 7-0-0 7-0-0 7-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MS Weight: 208 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purling. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=179(LC 7) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8), 28=-434(LC 8) Max Grav All reactions 250 lb or less at joints) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1). 28=626(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1692/1103, 3-4=105/259, 27-28=1129/710, 3-5=-441/520, 5-7=-436/514, 7-10=436/514, 10-11=436/514, 11-13=-436/514, 13-16=436/514, 16-18=-436/514, 18-19=-436/514, 19-21=-382/412,21-23=-382/412,23-25=-382/412, 25-27=-387/418 BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039 WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=772/745, 27-32=-1484/1044, 9-10=-463/453, 20-21=-462/454 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28. 8) Graphical purlin representation does not depict the size or the orientation of the purin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at 7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206 lb up at 19-11-4. 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at 25-11-4, and 158 lb down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69 lb down at 11-0-12, 69 Ib down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at 19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 -- The design/seIection of such connection devevice(s)-is- the responsibility of others. - - - ----- -- -- - - ®Q 1flrhhe leFO{�9sfglP s E)d:eaAioraFtmadsreppdfeliie ttnerfecetmMelltrl:rse etEdFLW(r mttW) a&haak2ABEFORE USE. DOMIfRW@rd9F 2a2h MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a tr�� t @ j9@9 s@�q�ply ng designer must verify the applicability of design parameters and properly incorporate this design Into the overall r buTd�� si n. rB dCi g iird iL2rl3'to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fabrication, storage, delivery, -erection and bracing of trusses and truss systems, see ANSLITPN Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Intannadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781811 M11392 BHA BOSTON HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 S Mar 9 202U MITeK Industries, Inc. Tue Mar 24 1Z:54:17 ZUZU Page 2 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-202688iPXb7HzCPegtXHTAgmFjM 1 K3EfmPcjgXzXjGq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39=20, 1-3=-54, 3-15=-54, 15-27=54, 27-29=-54 Concentrated Loads (lb) Vert: 35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F) 44=-23(F) 45=-23(F) 46=-23(F)47=-23(F) 48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F) 54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=118(F) 59=-118(F) 60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F) ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-69 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 iyY� WOW 6904 Parke Fast Blvd. Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781812 M11392 GRA HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HOXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvQzXjGo 11-0-0, 7-0-0 , 14-11-0 21-5-2 , 28.0-0 35-0-0 36-0-q y-0-0 7-0-0 7-11-0 6-6-2 6-6-14 7-0-0 -0-0 Scale = 1:60.3 5x12 MT18HS = 4.00 12 3x5 II 3x6 = 48 = 3 22 23 24 25 4 26 27 5 28 629 30 31 3x4 = 4x8 = 32 7 JJ 04 lY Jo JO J/ Jo Je II — MI 2x3 II 3x6 = 5x14 = 3x4 = 4x6 = 2x3 11 3x5 = 7-0-0 14-11-0 21-5-2 28-0-0 35-M , 7-0-0 7-11-0 6-6-2 6-6-14 7-0-0 Plate Offsets (X,Y)—[3:0-9-0,0-2-8],[6:0-3-8,0-2-0],[7:0-5-4,0-2.4),[13:0-4-0,0-3-0) LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.26 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017fTP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 4-13: 2x6 SP No.2 CSI. DEFL. in (loc) Well L/d PLATES GRIP TC 0.94 Vert(LL) 0.30 10-21 >792 240 MT20 244/190 BC 0.67 Vert(CT)-0.3010-12 >812 180 MT18HS 244/190 WB 1.00 Horz(CT) 0.09 8 n/a n/a Matrix -MS Weight: 153 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD Rigid ceiling directly applied or 4-6-8 oc bracing. WEBS 1 Row at midpt 6-13 2 Rows at 1/3 pts 3-13 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 84-8-0 Max Horz 2=-78(LC 6) Max Uplift 2=-448(LC 8). 13=-2442(LC 8), 8=-1159(LC 8) Max Grav 2=755(LC 17).13=3223(LC 1),8=1225(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1534/729, 3-4=1052/1347, 4-6=1052/1347, 6-7=1946/1834, 7-8=-2978/2565 BOT CHORD 2-15=-586/1423,13-15=-596/1464,12-13=-1710/1946,10-12=-2359/2830, 8-10=-2329/2789 WEBS 3-15=-159/733,3-13=-2917/1869,4-13=-848/801,6-13=-3504/3050,6-12=-430/666, 7-12=-940/731, 7-10=-489/690 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; save=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at joint 13 and 1159 lb uplift at joint 8. 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 Ib up at 17-114, 90 lb down and 155 lb up at 19-114, 90 lb down and 155 Ito up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-114, and 203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at 17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-114, 63 lb down and 3 lb up at 21-114, 63 lb down and 3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-114, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front IF) or back (B). r; � N l� This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®I QWINCA5i(61):si tOmdabdrs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II.7473 rev. 5/1912020 BEFORE USE. • D®lgnt4RWd,61ga�6vo MTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Bef re se, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall r building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply T19781812 M11392 GRA HIP 1 1 �THEWINDSOR Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 2 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzXjGo LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert: 3=-147(B) 7=-147(B) 15=-452(B)13=40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B) 32=-90(B) 33=-40(B) 34=-40(B) 35=-40(B) 36=-40(B) 37=-40(B) 38=-40(B) 39=-40(B) 40=-40(B) 41=-40(B) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE. ' Design valid for use only with MITekO connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS9TPIt Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781813 M11392 J1 MONO TRUSS 8 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 1-0-0 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TIC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.02 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=48(LC 12) Max Uplift 3=4(LC 9), 2=140(LC 12) Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KK-_nAsZgkf3CG_C WZOHIZIYbIBwXAho7vyEjSgvQzXjGo 1-0-0 Scale = 1:6.1 3x4 = DEFL. in (loc) I/deft Ud PLATES GRIP Vert(LL) -0.00 5 >999 240 MT20 244/190 Vert(CT) -0.00 5 >999 180 Horz(CT) 0.00 4 n/a n/a Weight: 5 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A Albani PE No.39380 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. ° Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP/f quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safetylnformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply T19781814 M11392 J3 MONO TRUSS 8 1 �THEWINDSOR Job Reference a tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:20 2020 Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq74_5olM7xUHXa95SNgNRszXjGn --0 3-0-0 41-00 3-0-0 3x4 = LOADING (pall) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 TCDL 7.0 Lumber DOL 1.25 BC 0.19 BCLL 0.0 Rep Stress Incr YES WB 0.00 BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12) Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. Scale = 1:9.4 DEFL. in (loc) Vdefl Lid PLATES GRIP Vert(LL) 0.01 4-7 >999 240 MT20 244/190 Vert(CT) -0.01 4-7 >999 180 Horz(CT) -0.00 3 n/a n/a Weight: 11 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply THE WINDSOR T19781815 M11392 J5 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:212020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYGIPFhlawzlzXjGm 6-0-0 Scale=1:12.7 5-0-0 5-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.07 4-7 >863 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.06 4-7 >964 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017frPI2014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 cc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 cc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=123(LC 12) Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12) Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119f2020 BEFORE USE. Design valid for use only with MI7ek® connectors. This design is based only upon parameters shown, and is for an individual building component, not m� a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply T19781816 M11392 J7 MONO TRUSS 24 �THEWINDSOR 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:21 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-wAHc WlvbgWiRpjPOibDeOrSnKmPGIPFhlawzlzXjGm -1-0-0 7-0-0 1-0-0 7-0-0 Scale: 314"=l' 3x4 = Plate Offsets (X,Y)— [2:0-1-14,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefi Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.17 4-7 >494 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.19 4-7 >447 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Harz 2=161(LC 12) Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12) Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at joint 2 and 12 lb uplift at joint 4. This item has been electronically signed and sealed by Alban!, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with M7ek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall r building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T79781817 M11392 KJ7 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:22 2020 Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-OMr_BsmXM7eZ3zlbyQ7SADNhnkgg7RvOwhJUWIzXjGI -1-5-0 6-8-12 9-10-1 1-5 0 6-8-12 3-1-5 Scale = 1:20.6 3x4 = �.... 5 3x4 = 6.8-12 3-1-5 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.04 7-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.08 7-10 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.24 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 38 lb FT = 0% LUMBER. BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical Max Horz 2=192(LC 8) Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=238(LC 8) Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-838/366 BOT CHORD 2-7=487/798, 6-7=487/798 WEBS 3-7=0/307, 3-6=-920/561 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at This item has been joint 2 and 238 lb uplift at joint 5. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). electronically Signed and sealed by Albani, Thomas, PE LOAD CASE(S) Standard using a Digital Signature. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Printed this Uniform Loads (plf) copies of Vert: 1-2=-54 document are not considered Trapezoidal Loads (plf) signed and sealed and the Vert: 2=0(F=27, B=27)-tcl 4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=49(F=-15, B=-15) signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33610 Data: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols PLATE LOCATION AND ORIENTATION 3/4 Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. Apply plates to both sides of truss and fully embed teeth. 0-116" For 4 x 2 orientation, locate plates 0- Vie" from outside edge of truss. This symbol indicates the required direction of slots in connector plates. Plate location details available in MiTek 20120 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSIITP11: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses. Numbering System 64-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 3 TOP CHORDS C1-2 C2-3 WEBS O U ACI IL OF- C7-6 C6-7 BOTTOM CHORDS 8 7 6 5 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS [CC -ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek@ All Rights Reserved !All MiTek' MiTek Engineering Reference Sheet: MII-7473 rev. 5/19/2020 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/rPI 1. 7. Design assumes trusses will be suitably protected from the environment in accord with ANSUTPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria. 21.The design does not take into account any dynamic or other loads other than those expressly stated.