HomeMy WebLinkAboutSTAMPED_PDF_AtT_Mobility_417613_Ankona_Fl-_FL_OAA743318_C2_02_PE_Letter MRSFL015936Eng. Number OAA743318_C2_02 December 11 2018 Page 1 of 2 ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com Structural Evaluation ATC Site Number & Name 417613, Ankona FL, FL Carrier Site Number & Name 10126629, Indian River Estates Site Location 6375 Federal Highway Port St. Lucie, FL 34952-9005, St Lucie County 27.34876666 N / 80.32691666 W Tower Description 150 ft Monopole Basic Wind Speed Code 124 mph (3-Second Gust, Vasd) / 159 mph (3-Second Gust, Vult) ANSI/TIA-222-G / 2015 IBC / 6th Edition, 2017 Florida Building Code Existing and Reserved Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 150.0 151.0 6 Ericsson Radio 2212 B13/B5 Platform w/ Handrails (12) 1 5/8" Coax (2) 1 5/8" Hybriflex Verizon 3 Ericsson RRUS-32 1 Raycap RCMDC-6627-PF-48 3 CSS X7-665-4 6 JMA Wireless X7CQAP-665-VR0 1 VZW Unused Reserve: 18,143 sq in 134.0 136.0 1 Raycap ASU9338TYP01 T-Arm (1) 1.58" Hybrid (12) 1 5/8" Coax Metro PCS 134.0 3 Nokia FRIG w/ Solar Shield 6 Nokia FXFB 133.0 3 60" x 12" Panel 3 52" x 14" Panel 120.0 120.0 6 Andrew ETD819G-12UB Low Profile Platform (2) 0.78" 8 AWG 6 (12) 1 5/8" Coax (1) 3/8" RET Control Cable AT&T Mobility 6 RFS FDGW5504/3C-3 1 Raycap DC6-48-60-18-8F Equipment to be Removed Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 120.0 120.0 3 Kathrein 800 10764 - (1) 0.35" Fiber AT&T Mobility 4 Kathrein 742-265 2 Kathrein 800 10122 6 Ericsson RRUS 11 (Band 12) (55 lb) Eng. Number OAA743318_C2_02 December 11 2018 Page 2 of 2 ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com Proposed Equipment Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD 120.0 120.0 3 Ericsson RRUS 8843 B2, B66A Low Profile Platform (4) 0.78" 8 AWG 6 (3) 0.39" Fiber Trunk AT&T Mobility 3 Ericsson Radio 4415 B30 3 Ericsson RRUS 4449 B5, B12 2 Raycap DC6-48-60-18-8C-EV 6 Kathrein 800-10864K 3 Kathrein 800-10964K 1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna above grade level (AGL). Install proposed coax inside of the pole shaft. The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are found different from those listed in the tables. The subject tower and foundation are adequate to support the above stated loads in conformance with specified requirements. ZH/ANG