HomeMy WebLinkAboutSTAMPED_PDF_AtT_Mobility_417613_Ankona_Fl-_FL_OAA743318_C2_02_PE_Letter MRSFL015936Eng. Number OAA743318_C2_02
December 11 2018
Page 1 of 2
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com
Structural Evaluation
ATC Site Number & Name 417613, Ankona FL, FL
Carrier Site Number & Name 10126629, Indian River Estates
Site Location 6375 Federal Highway
Port St. Lucie, FL 34952-9005, St Lucie County
27.34876666 N / 80.32691666 W
Tower Description 150 ft Monopole
Basic Wind Speed
Code
124 mph (3-Second Gust, Vasd) / 159 mph (3-Second Gust, Vult)
ANSI/TIA-222-G / 2015 IBC / 6th Edition, 2017 Florida Building Code
Existing and Reserved Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
150.0 151.0
6 Ericsson Radio 2212 B13/B5
Platform w/ Handrails (12) 1 5/8" Coax
(2) 1 5/8" Hybriflex Verizon
3 Ericsson RRUS-32
1 Raycap RCMDC-6627-PF-48
3 CSS X7-665-4
6 JMA Wireless X7CQAP-665-VR0
1 VZW Unused Reserve: 18,143 sq in
134.0
136.0 1 Raycap ASU9338TYP01
T-Arm (1) 1.58" Hybrid
(12) 1 5/8" Coax Metro PCS 134.0 3 Nokia FRIG w/ Solar Shield
6 Nokia FXFB
133.0 3 60" x 12" Panel
3 52" x 14" Panel
120.0 120.0
6 Andrew ETD819G-12UB
Low Profile Platform
(2) 0.78" 8 AWG 6
(12) 1 5/8" Coax
(1) 3/8" RET Control
Cable
AT&T Mobility 6 RFS FDGW5504/3C-3
1 Raycap DC6-48-60-18-8F
Equipment to be Removed
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
120.0 120.0
3 Kathrein 800 10764
- (1) 0.35" Fiber AT&T Mobility 4 Kathrein 742-265
2 Kathrein 800 10122
6 Ericsson RRUS 11 (Band 12) (55 lb)
Eng. Number OAA743318_C2_02
December 11 2018
Page 2 of 2
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com
Proposed Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
120.0 120.0
3 Ericsson RRUS 8843 B2, B66A
Low Profile Platform (4) 0.78" 8 AWG 6
(3) 0.39" Fiber Trunk AT&T Mobility
3 Ericsson Radio 4415 B30
3 Ericsson RRUS 4449 B5, B12
2 Raycap DC6-48-60-18-8C-EV
6 Kathrein 800-10864K
3 Kathrein 800-10964K
1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
Install proposed coax inside of the pole shaft.
The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements.
ZH/ANG