HomeMy WebLinkAboutCompaction Test m' 'u In-Place Density Report Client: Project:
&Associates, Inc. Permit#2009-0474 Renar Development Corp. 113-15-66-5434B
Report Date: 11/30/2020 3725 S. East Ocean Boulevard,Suite 101 Morningside Residential Lots
Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce
Florida Registration No.5950 Fort Pierce, FL
460 Nt.Concourse Place,Unit 1
Port Lucie,FIL 34986
Phone:e:772-878-8-0072072
Test Results
Maximum In Place In Place
Optimum `Dry In Place Dry Wet Probe
Retest Soil Moisture Density (pcf) Moisture Density Density Depth Percent Min Comp.
Test# Of Test Date Proctor ID Method Classification % % pcf) pcf) (in) Compaction (%) Remark
382 11/30/20 20-280 A 10.5 117.0 8.2 115.7 125.2 12 99 95 Pass
(Modified)
383 11/30/20 20-280 A -- 10.5 117.0 7.9 113.8 122.8 12 97 95 Pass
Modified
384 11/30/20 20-280 A - 10.5 117.0 8.8 116.0 126.2 12 99 95 Pass
(Modified)
385 11/30/20 20-280 A -- 10.5 117.0 9.7 115.4 126.6 12 99 95 Pass
(Modified)
386 11/30/20 20-280 A -- 10.5 117.0 13.1 111.4 126.0 12 95 95 Pass
(Modified)
387 11/30/20 20-280 A 10.5 117.0 12.9 112.E 127.1 12 96 95 Pass
(Modified)
388 11/30/20 20-280 A -- 10.5 117.0 13.8 114.4 130.2 12 98 95 Pass
(Modified)
389 11/30/20 1 20-280 A -- 10.5 117.0 1.1.6 1 114.9 128.2 12 98 95 Pass
(Modified)
Test Information
Gauge
Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician
382 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.NE Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
383 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.SE Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
384 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.SW Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
385 1 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.NW Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
386 Footings:House Pad for Lot 54 at 9605 Rainwood Court.N Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
387 Footings:House Pad for Lot 54 at 9605 Rainwood Court.S Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
388 Footings:House Pad for Lot 54 at 9605 Rainwood Court.W Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
389 Footings:House Pad for Lot 54 at 9605 Rainwood Court.E Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie
Remarks Comments
Pass:Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as
"Backscatter".Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
f l E ' Ardaman In-Place Density Report Client: Project:
&Associates, Inc. Permit#2009-0474 Renar Development Corp. 113-15-66-5434B
Report Date: 11/30/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential Lots
Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce
Florida Registration No.5950 - Fort Pierce, FL
460 NW Concourse Place,unit 1
Port St.Lucie,FL 34986
Phone:772-878-0072
r -' ` 71-11-
N\
i
No.63911
r
srA OF
foaLN;� ,
�11I14ti
This item has been digitally signed and sealed by Branch
Manager Dan J.Zrallack, P.E.on Dec 01,2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR.EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.