Loading...
HomeMy WebLinkAboutCompaction Test m' 'u In-Place Density Report Client: Project: &Associates, Inc. Permit#2009-0474 Renar Development Corp. 113-15-66-5434B Report Date: 11/30/2020 3725 S. East Ocean Boulevard,Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No.5950 Fort Pierce, FL 460 Nt.Concourse Place,Unit 1 Port Lucie,FIL 34986 Phone:e:772-878-8-0072072 Test Results Maximum In Place In Place Optimum `Dry In Place Dry Wet Probe Retest Soil Moisture Density (pcf) Moisture Density Density Depth Percent Min Comp. Test# Of Test Date Proctor ID Method Classification % % pcf) pcf) (in) Compaction (%) Remark 382 11/30/20 20-280 A 10.5 117.0 8.2 115.7 125.2 12 99 95 Pass (Modified) 383 11/30/20 20-280 A -- 10.5 117.0 7.9 113.8 122.8 12 97 95 Pass Modified 384 11/30/20 20-280 A - 10.5 117.0 8.8 116.0 126.2 12 99 95 Pass (Modified) 385 11/30/20 20-280 A -- 10.5 117.0 9.7 115.4 126.6 12 99 95 Pass (Modified) 386 11/30/20 20-280 A -- 10.5 117.0 13.1 111.4 126.0 12 95 95 Pass (Modified) 387 11/30/20 20-280 A 10.5 117.0 12.9 112.E 127.1 12 96 95 Pass (Modified) 388 11/30/20 20-280 A -- 10.5 117.0 13.8 114.4 130.2 12 98 95 Pass (Modified) 389 11/30/20 1 20-280 A -- 10.5 117.0 1.1.6 1 114.9 128.2 12 98 95 Pass (Modified) Test Information Gauge Test# Test Location Elevation Reference Make/Model/SN/Calibrated Field Technician 382 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.NE Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 383 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.SE Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 384 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.SW Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 385 1 Building Pad Fill:House Pad for Lot 54 at 9605 Rainwood Court.NW Corner -1.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 386 Footings:House Pad for Lot 54 at 9605 Rainwood Court.N Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 387 Footings:House Pad for Lot 54 at 9605 Rainwood Court.S Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 388 Footings:House Pad for Lot 54 at 9605 Rainwood Court.W Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie 389 Footings:House Pad for Lot 54 at 9605 Rainwood Court.E Footing -2.0 Top of Subgrade Troxler/T-3430/21330/ Tech,Port St.Lucie Remarks Comments Pass:Density Pass Tests are"Direct Transmission"(Method A)unless probe depth is noted as "Backscatter".Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. f l E ' Ardaman In-Place Density Report Client: Project: &Associates, Inc. Permit#2009-0474 Renar Development Corp. 113-15-66-5434B Report Date: 11/30/2020 3725 S.East Ocean Boulevard,Suite 101 Morningside Residential Lots Port St.Lucie Branch Test Method:ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No.5950 - Fort Pierce, FL 460 NW Concourse Place,unit 1 Port St.Lucie,FL 34986 Phone:772-878-0072 r -' ` 71-11- N\ i No.63911 r srA OF foaLN;� , �11I14ti This item has been digitally signed and sealed by Branch Manager Dan J.Zrallack, P.E.on Dec 01,2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT,THE PUBLIC AND OURSELVES,ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT,AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS,CONCLUSIONS OR.EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.