Loading...
HomeMy WebLinkAboutWindLoadCertification_48AquaRaDr_Deck_Witham_JLL_Signed 12.2.20Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Rear Deck Replacement and Extra Section - Latham Project Address: 48 Aqua Ra Drive, Jensen Beach, FL Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Code Sixth Edition with 20 10 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open 3. Risk Category:I X II _III IV Exposure Category: B X C D 4. Design Wind Velocity 170 mph X ASD LRFD End Zone Width: 1 ft 5. Mean Roof Height < 15 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: 71.06 Zone 5: 77.24 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF Dock: N/A PSF Deck: 50 PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: `"'a����� Digitally signed Joseph o t N meammers Cent # & co. cert Huth. _e _by Joseph L Lammers 78477 HfATEOF a9'4 Date:2O20.12.01 wni���`� I egITM Cardinal Engineering Associates, Inc. Company Name & Address Revised 12/07/2018