HomeMy WebLinkAboutBuilding Permit PackageALL APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 12/2/2020 Permit Number:
0
Building Permit Application -
Planning and Development services
Building and Code Regulation Division
2300 Virginia Avenue, Fort Plerce F134982
Phone: (772) 462-1553 Fax: (772)462.1578 Commercial Residential X
PERMITAPPLIGATION FOR: Mechanical
Address: 7000 deer park aye
Legal Description:
Property Tax lD tt: 1301-613-0173-000-2 Lot No.
Site Plan Name: Block No.
Project Name: erica lockwood
Setbacks Front Back: Right Side: Left Side:
LIKE FOR LIKE A/C CHANGEOLIT 16 SEER, 2.5 TON, 5 KW
and duct work
���lv�`�R�U��QNJN�O3M�T10�1�����
�
Yigna wor o e er orme un er is perms—ctec<s appy;
�HVAC Gas Tank ❑Gas Piping _Shutters Windows/Door's
Electric !Plumbing Sprinklers Generator Roof Roof pitch
Total Sq. Ft of construction: S Ft, of First Floor:
Cost of Construction: $ 9445,00 Utilities: �Sewer �Septic Building Height:
Name; CHRIS LANGEL
Name @rlCa IOCkW00d
Company: SEACDASTA/C
Address: 7000 deer park ave
City: fort pierce State: FL
Address: 3108 INDUSTRIAL 31st STREET
Zip Code: 34951 Fax:
City; FT PIERCE State: FL
Phone No, 772-834-7183
Zip Code: 34946 Fax: 772-448 4416
E-Mail;
Phone No, 772-466-2400
Fill in fee simple Title Holder on next page (if different
E-Mail: INFO@SEACOASTAIR.COM
from the Owner listed above)
State or County License: CMC035421
It value of construction is $2500 or more, a RECORDED Notice of Commencement Is required.
StJL LEt�11 NT 1 �0't�STRU�TIQN 11 N I Ali I?U W�i�Ul7� C10
h,
_
DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY. Not Applicable
Name: Name:
Address: Address:
City: State: _ City: State;
Zip: Phone: Zip: Phone:
FEE SIMPLE TITLE HOLDER: Not Applicable BONDING COMPANY: Not Applicable
Name: Name:
Address: Address:
City: City:
Zip: Phone: Zip: Phone:
I certify that no work or Installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that Is granting a ppermit will authorize the permit holder to build the subject structure
which is in conflict with any applicable Home Owners Assocation rules, bylaws or and covenants that may restrict or prohibit such
structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply,
in consideration of the granting of this requested permit, I do hereby agree that I will, In all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review; room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in your paying twice for
improvements to your property. A Notice of Commencement must be recorded and posted on the jobsite
before the first nspectiom yoyk'ntend to obtain financing, consult with lender or an attorney fore
commencin w rl or reco in our Notice of Commencement, n
s
Signature w er/Lessee/Contractor as Agent for Owner Signature f ntractcr/Licen e Holder
STATE OF FLORIDA STATE OF FLORIDA
COUNTY OFSTLUCIE COUNTY OPSTLuae
The forgoing instrument was acknowledge efore me The forgoing instrument was acknowledged before me
this 2 day of dec 20y this 2 day of dec 20 by
�, y
CHRIS LANGEL-L CHRIS LANGEL
(Name of person acknowledging) f Name of person acknowledging )
q�Salure
(gnature of Notary Public- State of Florida) of Nota Public-Sta��
Personally Known X _ OR Produced Identification Personally Known X OR Produced Identification
Type of identification Produced Type of Identification Produced
Commission No. GGJ4o5 •+";"%;;''•.,, JUSTI(lAfal�loPKINSCONNELLy Commission No, cGs4o ,
;; MYCOMMkSSION9GG940 82 i .yk,; JUST(NA ,HO INscoNNELLY
f+? ; s MYCOMMISSION$GG940582
,`•,P,fft"`see 'c•Bonded
7hrU Notary Pub�7brUndHN711ero o R eceal eta
Revised 07/15/20I A „fit•"' Handed Thm Notary ftllo UndoWfore
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
COMPLETE
INITIALS
This combination
qualifies
for a Federal
Energy Efficiency Tax Credit when
placed in service
between
1/1/2015 and
12/31/2020,
AHRI Type : RCU-A-CB (Split System: Air -Cooled Condensing Unit, Coil with Blower)
Series : 16 SEER AC
Outdoor Unit Brand Name: CARRIER
Outdoor Unit Model Number (Condenser or Single Package) : CA16NA030'0**W
Indoor Unit Model Number (Evaporator and/or Air Handler) : FV4CNF002L
Region : Southeast and North (AL, AR, DC, BE, FL, GA, HI, KY, LA, MD, MS, NC, OK, SC, TN, TX, VA, AK, CO, CT, ID, IL,
IA, IN, KS, MA, ME, MI, MN, MO, MT, ND, NE, NH, NJ, NY, OH, OR, PA, RI, SD, UT, VT, WA, WV, WI, WY, U.S.
Territories)
Region Note : Central air conditionors manufacfurad prior to January i, 2015 are eligible to be installed in all regions
until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in regions) for
which they meet the regional efficiency requirement.
f"Active" Model Status are ffiose that an AHRf Cedifica/ion Program Participant is currently producing AND selling or offering for sale; OR new models that are being
marketed but are not yet being produced"Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT Is still
Rellinti o Hering for sale.
atings that are accompanied by WAS indicate an Involuntary no-one. The new unhitched voters is she,,I nq with the cosvicusr WAS) rating
DISCLAIMER
AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for,
the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the
unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the
directory at www,alirldirectory.org.
TERMS AND CONDITIONS
This Certificate and Its contents are proprietary products of AHRI. This Certificate shall only be used for Individual, personal and
confidential reference purposes. The contents of this Certificate may not, In whole or in part, be reproduced; copied; disseminated;
entered Into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, mm
personal and confidential reference, AIR-CONDITIONING, HEATING,
CERTIFICATE VERIFICATION & REFRIGERATION INSTITUTE
The Information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link make life behWj
aad enter the AHRI Certified Reference Number and the date on which the certificate was Issued, top
which is listed above, and the Certificate No., which is listed at bottom right.
9
2020Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 132513101632413354
a ryPro ect Summa Job: 7000 Deer Park Avenue , ...
wrightsoft3 Date: Dec 01, 2020
Entire House By: Anthony Aversa
Sea Coast Air Conditioning
31061Mtatrial3lst Steet,Fort Pierce,FL34946PVgm:772466-2400 Ernad:d(spafd)@seawaslairwm
For: Erica Lockwood
7000 Deer Park Avenue, Fort Pierce, FL 32951
Phone: 772 834-7183
Notes: 7000 Deer ParkAvenue , Fort Pierce, FL, 34951
Weather: Fort Pierce, FL', US
Winter Design Conditions Summer Design Conditions
Outsidedb 42 OF Outsidedb 90 OF
Insidedb 70 OF Insidedb 75 OF
Design TD 28 OF Design TD 15 OF
Daily range M
Relative humidity 50 %
Moisture difference 61 grRb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16239 Btuh Structure 16017 Btuh
Ducts 2959 Btuh Ducts 4098 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 19198 Btuh Use manufacturer's data n
Rate/swing multiplier 0,95
Infiltration Equipment sensible load 19110 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 7222 Bluth
Ducts 1036 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingq (none)
Area (ft2) 1422 1422 Equipment latent load 8258 Btuh
Volume (fN) 11376 11376
Airchangges/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 27368 Btuh
Equiv AVF (cfm) 85 44 Req, total capacity at 0,70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Carrier r Trade Carrier
Model 5KW Heater Cond CA16NA030
AHRI ref Coil FV4CNF002
AHRI ref 9198752
Efficiency 100 EFF Efficiency 16 SEER
Heating input 5.1 kW Sensible cooling 20020 Btuh
Heating output 17517 Btuh Latent cooling 8580 Btuh
Temperature rise 18 OF Total cooling 28600 Btuh
Actual air flow 875 cfm Actual air flow 875 cfm
Air flow factor 0.046 cfm/Btuh Air flow factor 0,043 cfm/Btuh
Static pressure 0.60 in H2O Static pressure 0.60 in H2O
Space thermostat Load sensible heat ratio 0.71
Ooldrfalic valuos havo been manually avemidtlen
Calculations approved byACCA to meet a!t requirements of Manual J Sth Ed
_ 'r wrighisoft" 2020-Deo0213:1700
ACCA C:\Users�a'��Ri9H-Sute®UrYversa1201919.0.13 RSU28644 Pagel
versa�DesMoprLockvrootl.ry> CaIc=MJB Frond Door faces: S
#: 7000 peer Park Avenue ,Fort Pie
Performed by Anthony Aversa for:
Erlca Lockwood
7000 Deer Park Avenue
Fort Pierce, FL 32951
Phone: 772 834-7183
Level 2
Sea Coast Air Conditioning
3108 Intlustria131 st Street
Fort Pierce, FL34946
Phone: 772466-2400
dispatch@seawastair.com
Scale: 1 : 115
Page 1
Right-Suile®Universal 2019
19.0.13 RSU28W
2020-Dec-02 13:17:10
.sets\aversa\Desktop\Lockwood.rup