HomeMy WebLinkAboutEnergy Calcs & MJs Signed - Evans+ wrightsoftw Project Summary Enure House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH. FL 33069 Rare: 964421.41171`ax95442P0064 Web:w .lindsUb IrWm Proiect Information For. HOMECRETE Notes: EVANS RES. Job: Date: By. LINDSTROM Weather: St Lucie Cc Infl, FL, US Winter Design Conditions Summer Design Conditions Outsidedb 41 OF Outsidedb 90 OF Insidedb 70 OF Insidedb 75 OF DesignTD 29 OF DesignTD 15 OF Daily ranggee L Relativehumidity 50 % Moisture difference 57 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 34925 Btuh Structure 37963 Btuh Ducts 5386 Btuh Ducts 4095 Btuh Central vent (92cfm) 2917 Btuh Central vent (92 dim) 1549 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Equpmentload 43228 Btuh Use manufacturer's data n Ratelswingmultiptier Equipmeniload 0.95 41601 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3906 Btuh Central vent (92 dtn) 3537 Btuh Heating Coolingg Outside air 10420 Btuh Area (ftt) 2890 2890 Equipment latent load Mourne (ft') 28900 28900 Airchan slhour 0.32 0.16 Eau ipmentTotal Load lSen+Lat) 0.755 SHR 52021 4.7 Btuh ton Equiv. ANF (dm) 154 77 Req. total capacity at Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Tra Model CH16MA060 Cond CH16NA060 AHRI ref Coil FB4CNP061 AHRI ref Efficiency 8.5 HSPF Efficiency 16 SEER Heating input Sensible cooling 41000 Btuh Heating output 54000 Btuh Q 47-F Latent cooling 14000 Btuh Temperaturerise 25 OF Total cooling 55000 Btuh Actual airflow 1990 crrn Actual airflow 1990 cfm Airflow factor 0.049 cfmBtuh Airflowfactor 0.047 cfmBtuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Capacity balance point =0 OF Backup: CARRIER 8 KW Input=10 kW, Output= 34072 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 81h Ed. wrighSsoit' 2020-Nov-0210:1805 ..,..•. .,.,._.. Riglt-Sure® Uriversa1201919.0.12 RSU08398 Page 1 A A S:NROJECTS ENERG`A. MANUAL JWOMECRETE-EVANS.np Cato =KM Frort Dcar faces FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: HOMECRETE-EVANS Builder Name: HOMECRETE HOMES Street: 109 NE CHALESTON OAKS DR. Permit Office: City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Owner: EVANS RES. Jurisdiction: Design Location: FL, ST_LUCIE CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2627.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=6.5 2407.30 ft' 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 220.00 ft' 4. Number of Bedrooms 3 c N/A d. N/A R= ft' 5. Is this a worst case? No 10. Calling Types (2890.0 W.) R= ft2 Insulation Area S. Conditioned floor area above grade (W) 2890 a. Roof Deck (Unvented) b. N/A R=20.0 2890.00 ft' R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 7. Windows(415.1 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft' 6 400 a. U-Factor: Dbl, U=0.29 220.92 ft2 SHGC: SHGC=0.29 b. U-Factor: Dbl, U=0.32 120.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.26 a. Central Unit 55.0 SEER:1soo c. U-Factor: Dbl, U=0.29 74.21 ft' SHGC: SHGC=0.26 13. Heating systems x8tu/hr Efficiency d. U-Factor: NIA ft' a. Electric Heat Pump 54.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.023 ft. Area Weighted Average SHGC: 0.276 14. Hot water systems 8. Floor Types (2890.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2890.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. NIA R= ft, 15, Credits Pstat Glass/Floor Area: 0,144 Total Proposed Modified Loads: 81.94 c C PASS PASS Total Baseline Loads: 92.99 I hereby certify that the plans and specifications covered by Review of the plans and 8T,11� this calculation are in compliance with the Florida Energy specifications covered by this OF'T _ p Code. .,.1 calculation indicates compliance with the Florida Energy Code. F .n,,,,2j•-:; €`�',:,�4„ �O PREPARED BY: it. Before construction is completed 11--. `' DATE: this building will be inspected for compliance with Section 553.908 0' _� a I hereby certify that t s gned, is in compliance Florida Statutes. with the Florida Ener a Cpb �O OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed In accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 11/212020 10:10 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: HOMECRETE-EVANS Bedrooms: 3 Address Type, Street Address Building Type: User Conditioned Area: 2890 Lot # Owner Name: EVANS RES. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: HOMECRETE HOMES Rotate Angle: 0 Street: 109 NE CHALESTON Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Family Type: Single-family Whole House Fan: No City, State, Zip: PORT ST. LUCIE , New/Existing: New (From Plans) FL Comment: CLIMATE Design Location Design Temp Int Design Temp Heating Design Daily Temp TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 2890 28900 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil 10 Finished Cooled Heated 1 BED 3 175 1750 No 1 3 1 No Yes Yes 2 LAUNDRY 96 960 No 0 1 No Yes Yes 3 BATH 2 63 630 No 1 1 No Yes Yes 4 BED2 182 1820 No 1 1 No Yes Yes 5 FAMILY ROOM 780 7800 No 0 1 No Yes Yes 6 BATH 3 60 600 No 0 1 No Yes Yes 7 KIT LIV DIN FOY 850 8500 No 0 1 No Yes Yes 8 PANTRY 25 250 No 0 1 No Yes Yes 9 STUDY 143 1430 No 0 1 No Yes Yes 10 M TIOLET 28 280 No 0 1 No Yes Yes 11 M BATH 144 1440 No 0 1 No Yes Yes 12 M WIC 72 720 No 0 1 No Yes Yes 13 MASTER BED 272 2720 No 2 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BED 3 26 ft 0 175 ft' -_, 0 1 0 2 Slab -On -Grade Edge Insulatio LAUNDRY 9.5 ft 0 96 ft- __ 1 0 0 3 Slab -On -Grade Edge Insulatio BATH 2 6.5 ft 0 63 ft- 1 p 0 4 Slab -On -Grade Edge Insulatio BED 2 14 ft 0 182 ft- ___ 0 1 0 11/2/2020 10:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPpRT FLOORS # Floor Type 5 Slab -On -Grade Edge Insulatio Space Perimeter Perimeter R-Value FAMILY ROOM 25.5 ft 0 Area 780 ft2 Joist R-Value _ Tile 0 Wood Carpet 1 0 6 Slab -On -Grade Edge Insulatio BATH 3 12 ft 0 60 ft2 __- 1 0 0 7 Slab -On -Grade Edge Insulatio KIT LIV DIN FOY 31 ft 0 850 ft2 0.5 0.5 0 8SIab-On-Grade Edge Insulatio PANTRY 1 ft 0 25 ft2 ___- 1 0 0 9SIab-On-Grade Edge Insulatio STUDY 14 ft 0 143 ft2 ____ a 1 0 10SIab-On-Grade Edge Insulatio M TIOLET lift 0 28 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulatio M BATH 21 ft 0 144 ft2 0 0 12SIab-On-Grade Edge Insulatio M WIC 12 It 0 72 ft2 0 1 0 13SIab-On-Grade Edge Insulatio MASTER BED 30 ft 0 272 ft2 0 1 0 ROOF / Roof V # Type Materials Area Gable Area Roof Color Red Barr Solar Absor, SA Emitt Tested Emitt Deck Tested Insul. Pitch (deg) 1 Hip Composition shingles 3046 ft2 0 ft2 Medium N 0.9 No 0.9 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2890 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BED 3 0 Blown 175 ft2 0.1 Wood _ 2 Under Attic (Unvented) LAUNDRY 0 Blown 96 ft2 0.1 Wood _ 3 Under Attic (Unvented) BATH 2 0 Blown 63 ft2 0.1 Wood 4 Under Attic (Unvented) BED 2 0 Blown 182 ft2 0.1 Wood _ 5 Under Attic (Unvented) FAMILY ROOM 0 Blown 780 ft2 0.1 Wood _ 6 Under Attic (Unvented) BATH 0 Blown 60 ft2 0.1 Wood _ 7 Under Attic (Unvented) KIT LIV DIN FOY 0 Blown 850 ft2 0.1 Wood 8 Under Attic (Unvented) PANTRY 0 Blown 25 ft2 0.1 Wood 9 Under Attic (Unvented) STUDY 0 Blown 143 ft2 0.1 Wood 10 Under Attic (Unvented) M TIOLET 0 Blown 28 ft' 0.1 Wood 11 Under Attic (Unvented) M BATH 0 Blown 144 ft2 0.1 Wood 12 Under Attic (Unvented) M WIC 0 Blown 72 ft2 0.1 Wood 13 Under Attic (Unvented) MASTER BED 0 Blown 272 ft2 0.1 Wood 11I212020 10:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE Exterior Concrete Block- Int Insul BED 3 6.5 15 1 9 4 140.8 R' 0 0 _ 2 NE Exterior Concrete Block - Int Insul BATH 2 6.5 7 0 9 4 0.5 0 65.3 ft' 0 0 0.5 0 3 NE Exterior Concrete Block - Int Insul BED 2 6.5 15 1 9 4 140.8 ft' 0 0 0.5 0 -4 NE Exterior Concrete Block - Int InAAMILY ROO 6.5 27 5 9 4 265.9 W 0 0 0.5 0 5 SW Exterior Concrete Block - Int InsBAMILY ROO 6.5 20 0 10 0 200.0 W 0 0 0.5 0 6 W Exterior Concrete Block - Int InsBAMILY ROO 6.5 4 0 10 0 40.0 ft' 0 0 0.5 0 _ 7 NW Exterior Concrete Block - Int InsBAMILY ROO 6.5 26 11 9 4 251.2 ft' 0 0 0.5 0 _ 8 SW Exterior Concrete Block - Int Insul BATH 3 6.5 6 0 10 0 60.0 ft' 0 0 0.5 0 -9 NW Exterior Concrete Block - Int Insul BATH 3 6.5 6 5 9 4 59.9 ft' 0 0 0.5 0 _10 SE Exterior Concrete Block - Int InsKIT LIV DIN F 6.5 15 1 9 4 140.8 ft' 0 0 0.5 0 11 W Exterior Concrete Block - Int InSWIT UV DIN F 6.5 4 0 10 0 40.0 ft' a 0 0.5 0 -12 NW Exterior Concrete Block - Int Ins141T LIV DIN F 6.5 14 0 9 4 130.7 ft' 0 0 0.5 0 _13 SE Exterior Concrete Block - Int Insul STUDY 6.5 15 1 9 4 140.8 ft' 0 0 0.5 0 _ 14 NE Exterior Concrete Block - Int InsulM TIOLET 6.5 7 6 9 4 70.0 ft' 0 0 0.5 0 _15 SE Exterior Concrete Block- Int lnsulM TIOLET 6.5 4 4 9 4 40.4 ft' 0 0 0.5 0 16 SE Exterior Concrete Block - Int Insul M BATH 6.5 8 7 9 4 80.1 ft' 0 0 0.5 0 _17 SW Exterior Concrete Block - Int Insul M BATH 6.5 13 0 10 0 130.0 ft' 0 0 0.5 0 _18 SW Exterior Concrete Block - Int Insul M WIC 6.5 12 0 10 0 120.0 ft' 0 0 0.5 0 19 SW Exterior Concrete Block - Int InsUASTER BE 6.5 17 0 10 0 170.0 R' 0 0 0.5 0 _20 NW Exterior Concrete Block - Int Inse1ASTER BE 6.5 14 0 9 4 130.7 ft' 0 0 0.5 0 _21 N Garage Frame - Wood BED 3 11 22 10 220.0 ft' 0.23 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In _ 1 NE Insulated FAMILY ROO None .39 3 7 6 8 23.9ft' 2 SE Insulated KIT LIV DIN F None .39 3 7 6 8 23,9 ft' 3 N Wood BED 3 None .46 2.8 8 22.4 ft' WINDOWS Orientation shown is the entered. Proposed orientation, / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NE 1 Metal Double (Tinted) Yes 0.29 ' 0.29 N 22.9 ft' 2 ft 0 in 1 ft 0 In None None 2 NE 2 Metal Double (Tinted) Yes 0.29 0.29 N 6.0 f12 ft 0 in 1 ft 0 in None None _ 3 NE 3 Metal Double (Tinted) Yes 0.29 0.29 N 23.0 ft' 2 ft 0 in i it 0 In None None 4 NE 4 Metal Double (Tinted) Yes 0.29 0.29 N 23.0 ft' 2 ft 0 in 1 It 0 in None None 5 SW 5 Metal Double (Tinted) Yes 0.29 0.29 N 48.0 R' 2 ft 0 in 1 ft 0 in None None 6 W 6 Metal Double (Tinted) Yes 0.29 0.29 N 15.0 ft' 8 R 0 in 1 ft 0In None None 7 NW 7 Metal Double (Tinted) Yes 0.29 0,29 N 41.0 ft' 2 ft 0 in 1 ft 0 in None None 8 NW 9 Metal Double (Tinted) Yes 0.29 0.29 N 7.0 IF 2 ft 0 in 1 ft 0 in None None 9 SE 10 Metal Double (Tinted) Yes 0.29 0.26 N 27.1 ft' 2 ft 0 in 1 ft 0 in None None 10 SE 10 Metal Double (Tinted) Yes 0.29 0.29 N 5.0 ft' 8 ft 0 in 1 ft 0 In None None 11 NW 12 Metal Double (Tinted) Yes 0.32 0.26 N 72.0 ft' 8 ft 0 in 1 ft 0 in None None 11/2/2020 10:10 AM EnergyGauge® USA 6.0,02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 IWPI IT CI IIUMAOV ruenvr r�r v..wr.a.r� � RGrvR 1 WINDOWS Orientation shown is the entered, Pro osetl orientation. / V # Wall Omt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 12 13 14 15 SE 13 Metal Double (Tinted) Yes SE 16 Metal Double (Tinted) Yes SW 19 Metal Double (Tinted) Yes NW 20 Metal Double (Tinted) Yes 0.29 0.26 N 27.1 ft' 2 ft 0 in 1 ft 0 in None 0.29 0.26 N 20.0 ft' 2 ft 0 in 1 ft 0 in None 0.29 0.29 N 30.0 ft' 2 ft 0 in 1 ft 0 in None 0.32 0,26 N 48.0 ft' 8 ft 0 in 1 ft 0 in None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 538 f12 538 ft' 64 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EcILA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000318 2408.3 132.21 248.66 .1204 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 54 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 16 55 kBtu/hr 1650 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ftz DUCTS J-- # Supply --- ---- Return — Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF HVAC Heat Cool 1 Attic 6 400 ft' Attic 250 ft' Default Leakage Garage (Default) (Default) 1 1 11/2/2020 10:10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R406-2017 INPI IT CI IRAIIi rruer-wi re,- prm, my — — �+� 2w2�r,.,w r nu.rvrc t TEMPERATURES Thermostat: Y Fans: CMar Cooling Jan VNovct enting Jan FebProgramable Feb [[[[ 11 ki Mar Apr Apr r(eillling May, fI[[ ]] Jun 11 f[t[ 1i]] Aug f[ 11 Sep([ Dec [ ] lXl ] Jul lxl [x) Sep [[x�]] [X� Oct lxl Nov Dec c Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 B 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 78 78 78 78 80 80 so 80 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 68 66 66 68 68 68 58 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 68 66 88 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Fumlture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 3 Default(8 lbslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibs)sq.ft. ft2 ft 0.3 BATH 2 Default(8 lbalsq.ft. ft2 ft 0.3 BED 2 Default(8 lbs/sq.ft. ft2 ft 0.3 FAMILY ROOM Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 3 Default(8 lbslsq.ft. ft2 ft 0.3 KIT LIV DIN FOY Default(S lbs/sq.ft. ft2 ft 0.3 PANTRY Default(8 lbslsq.ft. ft2 ft 0.3 STUDY Default(8 Ibs/sq.ft. ft2 ft 0.3 M TIOLET Default(8 Ibs/sq.ft. ft2 ft 0.3 M BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibsfs .ft. ft2 ft 0.3 MASTER BED 1112/2020 10.10 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 88 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple -family 2. Single-family a) Supply ducts R 6.0 b) Return ducts R 6.0 c) AHU location Garage 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 55.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Groundhvater source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2890 d) Room uniVPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a.. 0.299 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.276 14. Heating system: Capacity 54.0 c) Area 7c. 415.1 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) t0A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 6.5 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 0.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier Installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has co li with the Florida Building Code, Energy Conservation, through the above energy saving features which will b in Igo (or exc de in this home before final inspection. Otherwise, a new EPL display card will be compl ed a o(yinstal.ee-d �de compliant features. Builder Signature: k- 4 Q Date: r rLv Address of New Home: 109 NE CHALESTON OAKS DR. City/FL Zip: PORT ST. LUCIE. FL 111212020 10:10:50 AM EnergyGauge® USA 6.0.03 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1