Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
20-182 Homecrete Evans 11-11-20 ShE1
A/C disc. ound to rebar in slab �--LECTi21CAL R I S E Electrical S mbol Legend $ Single Pole Switch ® Recessed Can Light 53 Double Pole Switch ® Eyeball Recessed Can Light Sb Dimmer Switch Exhaust Fan PB Push Button Switch Ceding Mounted Light Duplex Outlet Wall Mounted Light Special Receptacle PC Light with Pull Chain (attic) W�Fi Waterproof, ground fault interrupter © Computer Connection Jack ® Floor Duplex Outlet Flood Light ® Junction Box Electrical Panel m Q Thermostat g Electrical Meter c0 Central Vac A � c A/C Disconnect ® Smoke Detector Ceding Fan r© Television Jack Telephone Jack ® 2 x 4 Florescent Light ® 1 x 4 Florescent Light ❑I Intercom sPKR Speaker Hook —Up 0 Ceding Mounted Light Dome Style ♦ Pendant Light ® Motion Detector ( closet light ) © Carbon Monoxide Detector N \ PANEL "A" Poles BR Load Wire Description circ# circl* Description Wire Load BR Poles 2 40 -1.O kw #8 A/C comp 1 2 Double O en 48 8A kw 40 2 3 �{ 2 30 3.5 kw #10 AHU 5 6 Cook Top 48 6.1 kw 40 2 � g 2 30 4.5 kw #10 40 gal. water HTR 9 10 Dryer 48 5.0 kw 30 2 II 12 1 20 1.5 kw 412 Microwave 13 14 Irr. Pump 1*12 1.8 kw 20 2 I 20 1.5 kw #12 Kitchen B.A.C. i5 16 1 20 1.5 kw 412 Kitchen S.A.C. 11 18 Dishwasher 1*12 1.2 kw 20 1 1 20 1.2 kw #12 Clothes Washer 19 20 Refrigerator #12 1.2 kw 20 1 1 20 0.81 kw 1*12 Garage Door Opener 21 22 M. Bed, M. Bath LGT 414 15 1 1 20 0.81 kw 412 Garage Door Opener 23 24 Living, Study, Foyer LG7 414 15 1 1 20 1*12 Master Bed Recept 25 26 Family, Bath 42 LGT 414 15 I 1 20 412 Master Bed Recept 21 28 Bed 42, Bed 43, Laundr , Dining LGT 414 15 1 1 20 #12 Living Recept 29 30 Kitchen Lighting 414 15 1 1 20 #12 Bed 42 recept 31 32 Garage Lighting 1*14 15 1 1 20 412 Bed 43 Recept 33 34 Exterior Lighting 414 15 1 1 20 412 Garage Recept 35 36 spare I 20 412 Smoke Detectors 3-1 38 s are 1 20 412 Exterior Recept 39 40 spare s are 41 42 s are PANEL "A" LOAD CALCULATION SHEET Load Description Qt . Watts Total(Watts) General Lighting (3 watts sq. ft.) Small Appliance Circult(s) Cook Top Micorwave Refrigerator Dish Washer Double Oven Clothes Washer Clothes Dryer Water Heater Irrigation Pump Garage Door Opener 2890 3 8,00 2 1,500 3,000 I 6,100 6,100 1 1,100 1,100 1 1,200 1,200 1 1,200 1,200 1 8,400 8,400 1 1,200 1,200 1 5,000 5,000 1 4,500 4,500 1 1,800 1,800 2 810 1,620 Total Watts 44,390 First 10000 Watts 5100% 1 10,000 10,000 Remainder 34,390 5140% 1 O 13,156 Electric Heat or A/C 10,000 565% 1 10,000 10,000 Calculated Load Watts 33,156 Voltage 240 Calculated Wattage Divided bg Voltage = Total Amps 140.65 Panel Size to be installed = 200 Amps o0 � � o � � N co 00 � t U Chi — oo 2 ct LM J, try..,~� N ct N W LU O O W L-3 " O z W oo m 4 O < > NNE O U t-r < z a�- U m ~ W � X v � LL U LL 0) ELEC7RiC�4L fi L�4N ELECTRIC NOTES: SCALE: I/4" = I'—O" I. Use copper wire only, no aluminum. 2. Provide and wire all required smoke detectors. 3. Contractor to verify location of electrical service and provider -4. ALL paddle fans shall be on a rheostat. DATE DRAWN S. Recessed cans to be installed per NFPA requirements. 8-1 6. ALL Branch Circuits that supply 125v single phase 15 amp or 20 amp outlets DRAWNN BY: shall be protected by Combination —Type AFCI Circuit Breakers. 4.B.K. C.C.U. clt I. Tamper resistant AFCI receptacles to be installed in ALL rooms CHECKED BY: Kitchen, Bathrooms, and Garage. W 8. ALL bath and kitchen and garage receptacles to be GFCI protected, D-R-B- 9. ALL exterior outlets to be Wf /GFCI protected. MODEL: 10, A/C Return Air Balance Must comply w/ F.B.C. Mechanical 2010 ed. and SERENITY current version of any supplements to the 2010 ed. 2 CAR 11, A/C Refrigerant lines that are run thru slabs must be sleeved in PVC GARAGE 12, ALL A/C Equipment shall be 15 SEER RIGHT 13. Provide Disconnects at ALL appliances (water heater, A/C units, and Q SHEET ALL other equipment as required by N.E.C.) Q 14, A/C Ducts in Garage shall be metal or I" thick minimum rigid nonmetallic Class 0 or Class I duct or other approved material and shall have no openings into the garage. 1 15, Smoke Alarms shall be installed in the following locations: w a) In each sleeping room. OF q. b) Outside each separate sleeping area in the immediate vicinity of the bedrooms. JOB NUMBER: c) On each additional story of the dwelling pQ 2 0 -18 2 ** ALL Smoke Alarms shall be interconnected and hardwired ca ri h