HomeMy WebLinkAboutFL U20 Synthetic UnderlaymentBCiS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map Links Search
dbpProduct Approval
-
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL15216-R7
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer Owens Corning Roofing and Asphalt, LLC
Address/Phone/Email One Owens Corning Parkway
Toledo, OH 43645
(740)321-6345
Greg. Keeler@owenscorning.com
Authorized Signature Keeler Greg
Greg. Keeler@owenscorning.com
Technical Representative Greg Keeler
Address/Phone/Email 2790 Columbus Road
Granville, OH 43023
(740)321-6345
greg.keeler@owenscorning.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2020
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
FL15216 R7 COI 2020 01 COI NIEMINEN.pc�f
Standard
ASTM D1970 (tear)
ASTM D226 (physicals)
ASTM D4533 (tear)
ASTM D4798
TAS 117(B)
Year
2015
2009
2015
2011
1995
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
02/12/2020
Date Validated
02/13/2020
Date Pending FBC Approval
02/14/2020
Date Approved
04/07/2020
Summate of Products
FL #
15216.1 _
( Model, Number or Name
RhinoRoof U20, ABC Pro Guard 20
and SRS TopShield TS20 Roof
Description
Synthetic roof underlayments
Underlayments
v
Limits of Use
Approved for for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: See ER Section 5 for Limits of Use.
Installation Instructions
FL15216 R7 II 2020 02 13 FINAL ER OWENS
CORNING RHINOROOF FL15216-R7.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL15216 R7 AE 2020 02 13 FINAL ER OWENS
CORNING RHINOROOF FL15216-R7 pelf
Created by Independent Third Party:
I
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Fiorida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S, must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
® eCi
Credit Card
Safe
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203)262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
REPORTEVALUATION
Owens Corning Roofing and Asphalt, LLC Evaluation Report 140510.02.12-118
One Owens Corning Parkway FL15216-117
Toledo, OH 43659 Date of Issuance: 02/17/2012
(740) 321-6345 Revision 8: 02/13/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6t' Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments —�
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4.
Prepared by:
.yea � ��•• .•;
R
;a' T
Robert J.M. Nieminen, P.E.-;•��-. 4M; ; The facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DCA ANE1983 ���,,;,,+° Nieminen, P.E. on 02/13/2020. This does not serve as an
CERTIFICATION OF INDEPENDENCE: electronically signed document.
I. NEW ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW I etc, nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project
on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically
for that purpose.
02019 NEMO ETC, LLC
OMEMO I etc.
1. SCOPE: --
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments, as
produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following sections
of the 6th Edition (2017) Florida Building Code through testing in accordance with applicable sections of the
following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use
set forth herein.
Z. STANDARDS:
Section
Properties
Standard
Year
1507.1.1, R905.1.1 Exception,
Unrolling, Breaking Strength, Pliability
ASTM D226
2009
1518.4
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D1970
2015
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D4533
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
TAS 110
Pull -through resistance
TAS 117(B)
1995
3. REFERENCES:
Entity
Examination
Reference
Date
ITS (TST1509)
Physical Properties
100539395COQ-006
10/27/2011
ITS (TST1509)
Physical Properties
100539395COQ-002
10/27/2011
ITS (TST1509)
Physical Properties
100539395COQ-006
03/14/2014
PRI (TST5878)
Physical Properties
OCF-330-02-01
09/20/2017
PRI (TST5878)
ASTM D1970; Tear strength (Qingdao)
OCF-330-02-02
10/03/2017
PRI (TST5878)
TAS 117(B); Pull -through
OCF-422-02-01
04/03/2018
PRI (TST5878)
ASTM D226,ASTM D4S33 (Tear strength)
OCF-464-02-02
12/10/2019
PRI (TST5878)
Physicals Properties & AW (Silvassa)
OCF-394-02-07.4
01/06/2020
PRI (TST5878)
Accelerated Weathering (Qingdao)
OCF-464-02-02.2
01/06/2020
ITS (QUA1673)
Quality Control
Service Confirmation
09/30/2017
4.
4.1
4.2
43
PRODUCT DESCRIPTION:
Product
Specification
Plant(s)
Description
RhinoRoof U20
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlayment
ABC Pro Guard 20
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlayment
SRS TopShield TS20
FBC 1507.1.1 & R905.1.1
(Exception)
Qingdao, China
Silvassa, India
Multilayered polymer woven
coated synthetic roof underlaymer
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments may be used with any prepared
roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request
may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting
data for the prepared roof covering.
NEMO ETC, LLC Evaluation Report 140510.02.12-RB
Certificate of Authorization #32455 6T" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020
Page 2 of 4
5.4 Allowable Roof Covers:
ONEMOletc.
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Tile
Metal
Wood Shakes &
Shingles
Slate or
Simulated Slate
RhinoRoof U20
Yes
No
Yes
Yes
No
ABC Pro Guard 20
Yes
No
Yes
Yes
No
SRS TopShield I
Yes
No
Yes
Yes
No
5.5 Exposure Limitations:
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 shall not be left exposed for longer than 90-days after
installation.
6. INSTALLATION:
6.1 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments shall be installed in accordance
with the manufacturer's published installation instructions subject to the Limitations set forth in Section 5 herein
and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application.
6.3 RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20:
6.3.1 NON-HVHZ Jurisdictions:
6.3.1.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for
double -layer applications.
6.3.1.2 Fasteners:
For exposure up to maximum 24 hours, corrosion resistant fasteners may be 1-inch roofing nails with a 3/8-inch
diameter head, minimum 1-inch diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps
(with the rough edge facing up). The use of staples is prohibited.
For exposure beyond 24 hours up to maximum 30 days, corrosion resistant fasteners shall be minimum 1-inch
diameter plastic or metal cap nails or FBC HVHZ nails & 1-5/8" diameter tin caps (with the rough edge facing up).
The use of staples is prohibited.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails shall
be required where the ultimate design wind speed, V,,,,, equals or exceeds 150 mph."
Owens Corning Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails
in lieu of metal cap nails for these applications, when the RhinoRoof U20, ABC Pro Guard 20 or SRS TopShield TS20
underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1
or R905.1.1.
6.3.1.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.3.1.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 12-inches and side (horizontal) laps shall be minimum 22-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
NEMO ETC, LLC Evaluation Report 140510.02.12-118
Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION FL15216-R7
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underlayments Revision 8: 02/13/2020
Page 3 of 4
ONEjetc
Begin by fastening a 22-inch wide strip along the eaves. Place a full -width sheet over the starter,comp e eily
overlapping the starter course. Continue upslope, maintaining minimum 22-inch side (horizontal) laps, resulting in
a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 4-inch D.C.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.3.2 I HVHZ Jurisdictions:
6.3.2.1 Shall be Installed In a shingle fashion with minimum 4-inch wide side (horizontal) laps and minimum 6-inch wide
end laps.
6.3.2.2 Shall be fastened with FBC HVHZ approved corrosion resistant, 1-5/8" diameter tin -caps and 12 gauge 1.25" long
annular ring -shank nails (FBC 1517.5) spaced max. 6-inch o.c. at all laps and 12-inch D.C. at three (3) equally spaced
rows in the field of the sheet.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the manufacturer or the named QA entity for plants covered under Rule 61G20-3 QA requirements. Refer
to Section 4 herein for product & production locations having met codified physical properties specifications.
9. QUALITY ASSURANCE ENTITY:
Intertek Testing Services NA Inc. — ETL/Warnock Hersey — QUA1673; (604) 520-3321;
peter.gildenstern@intertek.com
- END OF EVALUATION REPORT -
NEMO ETC, LLC
Certificate of Authorization #32455 6'" EDITION (2017) FBC NON-HVHZ AND HVHZ EVALUATION Evaluation Report 1405101 2.12-R8
6.117
RhinoRoof U20, ABC Pro Guard 20 and SRS TopShield TS20 Roof Underla ments FL/13 2020
Y Revision 8: 02J13/2020
Page 4 of 4