Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
FBC_Product_Approval_Assembly_Chart
NEMO|etc. NEMO ETC, LLC Evaluation Report C33680.09.10-R24 for FL14083-R24 Certificate of Authorization #32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 24: 06/08/2020 ©2019, NEMO ETC, LLC Carlisle Sure-Weld TPO Single Ply Roof Systems; (717) 245-7264 Appendix 1, Page 81 of 87 TABLE 7C: STEEL - RECOVER SYSTEM TYPE C-2: PLATE-BONDED ROOF COVER All areas where the existing metal panels do not lay flush on the underlying purlin shall have a 0.25-inch diameter pilot hole pre-drilled into the panel prior to driving the Purlin Fastener into the purlin System No. Substrate (Note 1) Insulation Layer (Note 5) Attachment Roof Cover / Adhesive MDP (psf) Fasteners (Note 11) Spacing RHINOBOND SYSTEMS: R-46 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 120-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 12-inch o.c. along purlins Sure-Weld (minimum 60-mil) or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate ;TPOͿ ǁiƚh RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -30.0 R-47 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 120-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 6-inch o.c. along purlins Sure-Weld or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate (TPO) with RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -37.5 R-48 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 60-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 12-inch o.c. along purlins Sure-Weld or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate (TPO) with RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -37.5 R-49 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 60-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 12-inch o.c. along purlins Sure-Weld (minimum 60-mil) or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate ;TPOͿ ǁiƚh RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -45.0 R-50 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 120-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 6-inch o.c. along purlins Sure-Weld (minimum 60-mil) or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate ;TPOͿ ǁiƚh RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -52.5 R-51 Existing standing seam or lap seam metal roof covers having min. 16 ga. (0.0598-inch) to max. 3/16-inch thick steel purlins spaced max. 60-inch o.c. One or more layers, any combination, preliminarily fastened Carlisle HP Purlin Fasteners or RetroDriller Fasteners and RHINOBOND Insulation Plate (TPO) are fastened through to purlins 6-inch o.c. along purlins Sure-Weld or Sure-Weld EXTRA bonded to RHINOBOND Insulation Plate (TPO) with RHINOBOND ƚŽŽů Ɖeƌ ŵaŶƵfacƚƵƌeƌ͛Ɛ instructions. -67.5 ISOWELD INDUCTION WELDING SYSTEM: R-52 Existing standing seam or lap seam metal roof covers having min. 16 gauge (0.0598 inch), 50 ksi steel purlins spaced max. 60-inch o.c. One or more layers, any combination, preliminarily fastened SFS Purlin Fastener with SFS isoweld® TPO Plates (FI-P-6.8-TPO) are fastened through to purlins 12-inch o.c. along purlins Sure-Weld or Sure-Weld EXTRA bonded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -37.5 R-53 Existing standing seam or lap seam metal roof covers having min. 16 gauge (0.0598 inch), 50 ksi steel purlins spaced max. 60-inch o.c. One or more layers, any combination, preliminarily fastened SFS Purlin Fastener with SFS isoweld® TPO Plates (FI-P-6.8-TPO) are fastened through to purlins 6-inch o.c. along purlins Sure-Weld or Sure-Weld EXTRA bonded to SFS isoweld® TPO Plates with SFS isoweld® 3000 stand-up tool. -90.0