Loading...
HomeMy WebLinkAboutExtreme Metal 1 standing seam installation instructions2160 SW Poma Drive Palm City, FL 34990 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-31 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" {mina Pancake Head Wood Screw to penetrate 3/16" (min.) thru bottom of support. Adhesive/Sealant : Bostik 915TM Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads METHOD 1 DESIGN PRESSURE* ,86 PSF Main field FASTENER SPACING 6" O.C. SE MA ADHESIVE Not required METHOD 2 -97.25 PSF Perimeter fi- O.C. 3/16" continuous bead (see details) Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimens #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial 1WOM1141rogy' company manufacturing or distributing products under this evaluation. v ,,*' ❑, 8r} �� • � Locke Bowden, P.E. is not owned, operated, or controll h, 4 ;npi ft fan' cturer, or distributing products under this report. ' •. . r • w � # + � seal STATE OF ; OR VO4 ';-' UNAL E Prp,srfra �A Limitations- 1 . Underlayment to be compliance with current Florida Building Code (FBC)2017 6m ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6t' ed., and per with Manufactsurer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method; 1-0 4. Engineering analysis for "project specific approval by local authorities wljurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w1FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (25GA Steel), 16"' Wide Roof Panel - Details 16" Panel Profile 16" o. c. 4` 11 314—I— Deck., -15132" or greater Plywood, or Wood plank Integral Snap Lock For METHOD 2: Apply 3116" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head Mod Screw (Typical Fastening Pattern Across Width) 111 FL 17022.5 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel w Details us" -15132" or greater Plywood, or - Wood plank F'astPnar Isometric View For Method 2 Apply 3/16" Bead Bostik 915-1- Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A)