HomeMy WebLinkAboutChristopher Gay Load CalcWt`I htsoft Project Summary Job: 5365 San Benedetto PI, Fo...
9 Entire House Date: December t, 2020
Webreps LLC Plan: 5365 San Benedetto PI
1880 82nd Ave, Veru Beach, FI32966 Phone: (800) 810-3280 License: 5365 San Benedello PI, FortP!., FL
For: Advantage A/C Of The treasure Coast
Ft. Pierce, FL
Email: advantagepermits@hotmail.com
Notes: 5365 San Benedetto Pl, Fort Pierce, FL
Weather:
Winter Design Conditions
Outside db
Inside db
Design TD
Heating Summary
Structure
Ducts
Central vent (26 cfm)
Outside air
Humidification
Piping
Equipment load
Infiltration
Method
Construction quality
Fireplaces
Area (ft2) Neatin 360
Volume (fP) 3240
Air changes/hour 0.61
Equiv.AVF (cfm) 33
43 OF
72 'F
29 'F
6420 Btuh
0 Btuh
822 Btuh
109 Btuh
0 Btuh
7351 Btuh
Vero Beach Muni, FL, US
Simplified
Average
0
Heating Equipment Summary
Make Mitsubishi Electric
Trade Mitsubishi Electric
Model MUZ-GLI2NAH***
AHRI ref 202680595
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flaw factor
Static pressure
Space thermostat
Capacity balance point = 30 OF
Calculations
Coo369
3240
0.32
17
9 HSPF
Summer
Outside db
Inside db
Design TD
Daily range
Relative humidity
Moisture difference
Sensible Cooling
Structure
Ducts
Central vent (26 cfm)
Outside air
Blower
Use manufacturer's data
Rate/swing multiplier
Equipment sensible load
Latent Cooling Equips
Structure
Ducts
Central vent (26 cfm)
Outside air
Equipment latent load
Equipment Total Load (Sen+Lait)
Req. total capacity at0.70 SHR
Conditions
91 OF
75 OF
16 OF
L
50 %
59 grAb
t Load Sizing
5752 Btuh
0 Btuh
439 Btuh
1707 Btuh
y
1.00
7898 Btuh
Load Sizing
1997 Btuh
0 Btuh
1040 Btuh
3037 Btuh
10935 Btuh
0.9 ton
Cooling Equipment Summary
Make
Mitsubishi Electric
Trade
Mitsubishi Electric
Cond
MUZ-GL12NAH***
Coil
MSZ-GL12NA***
AHRI ref
202680595
Efficiency
13.0 EE
. 23.1 SEER
Sensible cooling
14400
Btuh@47°F
Latentcooling
33
OF
Total cooling
400
cfm
Actual airflow
0.062
cfm/Btuh
Airflowfactor
0
in H2O
Static pressure
by ACCA
Load sensible heat ratio
to meet all renifiramentc of Mani ial 1 Rth
8400
Btuh
3600
Btuh
12000
Btuh
400
cfm
0.070
cfml8tuh
0
in H2O
0.72
wrightsoit` Right-Suite®Universa1201919.0.21 RSU16998 2020-Deo-01 15.44.47
...WHOF115385 San Benedetto PI Fort Pierce FLrup Cale- MJ8 faces E
AC