Loading...
HomeMy WebLinkAbout206161-1d Compaction signedHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:206161-1d/DJ/jo PERMIT #:NUC #404 CONTRACTOR:Hector Gomez Nuc Model:MC-1 Elite JOB LOCATION:709 Easy Street Nuc Serial #:31404 Fort Pierce, Florida ITEM TESTED:Compacted Foundation Fill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.E.0" - 12"37 107.2 111.8 95.9% 2. S.E."40+108.4 "97.0% 3. Center "35 106.7 "95.4% 4. S.W."40+109.0 "97.5% 5. N.W."40+108.2 "96.8% Soil Description: Tan Sand with traces of Clay In Place Moisture: 12.8% Proctor Optimum Moisture: 12.7% Proctor Max. Dry Density: P.C.F. 111.8 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Julie E. Keller, P.E. President PE # 68366 12/3/2020 Email to: Port St Lucie Building Department; hector146gomez@hotmail.com Proudly Serving Florida since 1990 SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 December 2, 2020 2008-0792 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. 108.0 109.0 110.0 111.0 112.0 113.0 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight