HomeMy WebLinkAboutwindow door openingA FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET
Definition of Comer Zone -10 % of least horizontal dimension or 40 % of the mean roof height, whichever is smaller, but not less than 4 % of least horizontal dimension or 3 ft
OPENING
LOCATION
NUMBER
(Location)
Corner Zone
or Interior
IS THIS A
WINDOW
OR DOOR
GLAZING
TYPE
PRODUCT
ACCEPTANCE
NUMBER
PRODUCT APPROVAL
APPROVED PRESSURE RATING
REQUIRED OPENING
DESIGN PRESSURE
MAXIMU
M
TESTED
SIZE
ROUGH
OPENING
DIMENSIONS
MULTIPLE
WINDOW
MULLION
REQ Y/N/NA
ARE
SHUTTERS
REQ Y/N
+pSF
()
(-) PSF
+pSF
()
(-) PSF
1
Int
w;»a°w
�/s" Lauri
FL5823.1
67.5
67.5
36.8
-40.0
53x76
36x61
No
No
2
End
wiaa°w
vs^ Lam;
FL5823.1
67.5
67.5
36.8
-48.5
53x76
36x61
No
No
3
Int
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
36x36
N/A
N/A
4
End
wiaa°w
vs�� Lauri
FL5823.1
67.5
67.5
36.8
-48.5
53x76
36x61
No
No
5
Int
wiaaow
vs�� Lam;
FL5823.1
67.5
67.5
36.8
-40.0
53x76
36x61
No
No
6
Int
Door
'"La'°iI�
FL14850.1
70
70
36.0
-39.2
40x97
37x80
No
No
7
Int
winoaw
�/a��Lami
FL16177.1
70
70
37.2
-40.4
52x62
36x52
No
No
8
Int
w;aa°w
vs"La,ni
FL16177.1
70
70
37.2
-40.4
52x62
36x52
No
No
9
Int
wiaaow
vs^Lauri
FL16177.1
70
70
37.2
-40.4
52x62
36x52
No
No
10
Int
wiaaow
vs"Lauri
FL16177.1
70
70
36.8
-40.0
52x62
36x61
No
No
11
End
wiaaow
'/s"Lauri
FL16177.1
70
70
36.8
-48.5
52x62
36x61
No
No
12
Int
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25x37
N/A
N/A
13
Int
wiaaow
�/s��Lami
FL16177.1
70
70
37.6
-40.8
52x62
26x61
No
No
14
Int
wiaaow
vs"Lauri
FL16177.1
70
70
37.6
-40.8
52x62
26x61
No
No