Loading...
HomeMy WebLinkAboutHealth Dept Approval APPLICATION #:AP 1398333 STATE OF FLORIDA PERMIT #:56-SF-1924861 DEPARTMENT OF HEALTH DOCUMENT #:F11541372 c ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM r CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:02/14/2019 W"sY FEE PAID:515.00 RECEIPT #:56-PID-3859861 APPLICANT: Linda Tuning AGENT: Culpepper&Terpening, Inc PROPERTY ADDRESS: 6000 Hickory Dr Fort Pierce, FL 34982 LOT: 5&6 BLOCK: 70 SUBDIVISION: Indian River Estates ID#: 3402-609-0647-000-9 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [1] 1537.00 [21 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 15 FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS 75 FT [ ] [041 MULTI-CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-16DC4 2. [ ] [32] POTABLE WATER 42 FT [ ] [071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 5 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1) 271.68 [2] 305.64 SQFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. 6 [ ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 11/24/2020 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 1.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR Jason Harris(All About Septi [ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 08/25/2020 DISAPPROVED Environmental Sp e list Hunter Collier(FDOH in Broward County) FINAL SYSTEM [ AppROVED / DISAPPROVED 7: A St. Lucie CHD DATE: 11/24/2020 Environmental Spe list 11 Brian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1398333 EID1924861 s APPLICATION #:AP1398333 STATE OF FLORIDA PERMIT #:56-SF-1924861 1 1> r DEPARTMENT OF HEALTH DOCUMENT #:FI 1541372 c , ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:02/14/2019 FEE PAID:515.00 RECEIPT #:56-P I D-3859861 Violation Number Comment Comments The system is sized for 5 bedrooms with a maximum occupancy of 10 persons(2 per bedroom),for a total estimated flow of 460 gpd. New septic tank installed. Drainfield installed in trench configuration. System had violations at time of inspection and was not given approval to cover. Contractor notified by phone. Contractor will call this in when it is ready for reinspection. New ST, and 1x4+4x5 and 3x4+3x5 long TRENCH DFs installed. NO OUTLET FILTER INSTALLED. CONTRACTOR NOTIFIED THAT FILTER MUST BE ACCESSIBLE AT FINAL INSPECTION. System ok to cover. Contractor notified by phone. Needs final inspection for filter installation, mound system and final site grading. Filter installed. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1398333 EID1924861