HomeMy WebLinkAbout6000 hickory dr faAPPLICATION # : AP 1398333
STATE OF FLORIDA PERMIT #:56-SF-1924861
DEPARTMENT OF HEALTH DOCUMENT #:F11541372
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:02/14/2019
FEE PAID:515.00
RECEIPT #:56-PID-3859861
APPLICANT: Linda Tuning
AGENT: Culpepper & Terpening, Inc
PROPERTY ADDRESS: 6000 Hickory Dr Fort Pierce, FL 34982
LOT: 5 & 6
BLOCK: 70
SUBDIVISION:
Indian River Estates ID#: 3402-609-0647-000-9
CHECKED [X) ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ 1 [01]
TANK SIZE [1] 1537.00 [21
[ 1 [271
SURFACE WATER FT
[ 1 [021
TANK MATERIAL Polypropylene
[ ] [281
DITCHES 15 FT
[ ] [031
OUTLET DEVICE
[ ] [291
PRIVATE WELLS 75 FT
[ 1 [041
MULTI -CHAMBERED [ Y N ]
[ ] [303
PUBLIC WELLS FT
[ 1 [051
OUTLET FILTER Polylok PL-68
[ ] [311
IRRIGATION WELLS FT
[ ] [061
LEGEND 1. 70-143-16DC4 2.
[ ] [321
POTABLE WATER 42 FT
[ ] [071
WATERTIGHT
[ ] [331
BUILDING FOUNDATIONS 5 FT
[ 1 [081
LEVEL
[ ] [341
PROPERTY LINES 5 FT
[ 1 [091
DEPTH TO LID
[ ] [351
OTHER FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [101
AREA [1) 271.68 [2) 305.64 SQFT
[ ] [361
DRAINFIELD COVER
[ ) [111
DISTRIBUTION BOX HEADER X
[ ) [371
SHOULDERS
[ ) [12)
NUMBER OF DRAINLINES 1. 5.00 2. 6
[ ] [38)
SLOPES
[ 1 [131
DRAINLINE SEPARATION
[ ] [391
STABILIZATION 11/24/2020
[ 1 [141
DRAINLINE SLOPE
[ ] [151
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 1.00
[ 1 [401
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION
[ ] [411
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS
[ ] [421
ALARMS
[ ] [191
AGGREGATE SIZE
[ ) [431
MAINTENANCE AGREEMENT
[ 1 [201
AGGREGATE EXCESSIVE FINES
[ 1 [441
BUILDING AREA
[ 1 [211
AGGREGATE DEPTH
[ ) [451
LOCATION CONFORMS WITH SITE PLAN
[ l [461
FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ l [47)
CONTRACTOR Jason Harris (All About Septi
[ 1 [221
FILL AMOUNT
[ l [481
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [23)
FILL TEXTURE
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [25)
AREA REPLACED
[ ) [491
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL
[ ) [501
TANK CRUSHED & FILLED
Comments: Comments are on page 2.
/
St. Lucie CHD DATE: 08/25/2020
CONSTRUCTION
[ APPROVED
DISAPPROVED Environmental Sp e
list Hunter Collier (FDOH in Broward County)
FINAL SYSTEM
[ APPROVED / DISAPPROVED 7:A
St. Lucie CHD DATE: 11/24/2020
Environmental Spe
list 11 Brian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1 AP1398333
EID1924861
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1398333
PERMIT #:56-SF-1924861
DOCUMENT # : FI 1541372
DATE PAID:02/14/2019
FEE PAID:515.00
RECEIPT # :56-P I D-3859861
The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of 460
gpd.
New septic tank installed. Drainfield installed in trench configuration. System had violations at time of inspection and was not
given approval to cover. Contractor notified by phone. Contractor will call this in when it is ready for reinspection.
New ST, and 1x4+4x5 and 3x4+3x5 long TRENCH DFs installed. NO OUTLET FILTER INSTALLED. CONTRACTOR NOTIFIED
THAT FILTER MUST BE ACCESSIBLE AT FINAL INSPECTION. System ok to cover. Contractor notified by phone. Needs final
inspection for filter installation, mound system and final site grading.
Filter installed. Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1398333 EID1924861