HomeMy WebLinkAboutdestiny reportm' 'uIn-Place Density Report Client: Project:
& Associates, Inc. Permit # 2009-0474 Renar Development Corp. 113-15-66-5434B
Report Date: 11/30/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots
Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce
Florida Registration No. 5950 - Fort Pierce, FL
460 NW Concourse Place, Unit 1 y��y� / 7
Port e: 772Lucie,78-0072 9, ,,{ � � � �� �� "
Phone:772-878-0072 -
Test Results
Test #
Retest
Of
Test Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
%
Maximum
` Dry
Density (pcf)
In Place
Moisture
%
In Place
Dry
Density
pcf)
In Place
Wet
Density
pcf)
Probe
Depth
(in)
Percent
Compaction
Min Comp.
(%
Remark
382
11/30/20
20-280
(Modified)
A
10.5
117.0
8.2
115.7
125.2
12
99
95
Pass
383
11/30/20
20-280
Modified
A
--
10.5
117.0
7.9
113.8
122.8
12
97
95
Pass
384
11/30/20
20-280
(Modified)
A
-
10.5
117.0
8.8
116.0
126.2
12
99
95
Pass
385
11/30/20
20-280
(Modified)
A
--
10.5
117.0
9.7
115.4
126.6
12
99
95
Pass
386
11/30/20
20-280
(Modified)
A
--
10.5
117.0
13.1
111.4
126.0
12
95
95
Pass
387
11/30/20
20-280
(Modified)
A
10.5
117.0
12.9
112.6
127.1
12
96
95
Pass
388
11/30/20
20-280
(Modified)
A
--
10.5
117.0
13.8
114.4
130.2
12
98
95
Pass
389
11 /30/20 1
20-280
(Modified)
A
--
10.5
117.0
1.1.6
114.9
128.2
12
98
95
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
382
Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. NE Corner
-1.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
383
Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. SE Corner
-1.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
384
Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. SW Corner
-1.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
385
Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. NW Corner
-1.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
386
Footings: House Pad for Lot 54 at 9605 Rainwood Court. N Footing
-2.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
387
Footings: House Pad for Lot 54 at 9605 Rainwood Court. S Footing
-2.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
388
Footings: House Pad for Lot 54 at 9605 Rainwood Court. W Footing
-2.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
389
Footings: House Pad for Lot 54 at 9605 Rainwood Court. E Footing
-2.0
Top of Subgrade
Troxler / T-3430 / 21330 /
Tech, Port St. Lucie
Remarks
Comments
rass.-Density Pass
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.
& Associates, Inc.
Permit # 2009-0474
Report Date: 11/30/2020
Port St. Lucie Branch
Test Method: ASTM D6938
Florida Registration No. 5950
-
460 NW Concourse Place, Unit 1
Port St. Lucie, FL 34986
Phone:772-878-0072
fflE �;, r In -Place Density Report client:
Renar Development Corp.
3725 S. East Ocean Boulevard, Suite 101
Stuart, FL 34996
Project:
113-15-66-5434B
Morningside Residential Lots
Fort Pierce
Fort Pierce, FL
This item has been digitally signed and sealed by Branch
Manager Dan J. Zrallack, P.E. on Dec 01, 2020 using a
Digital Signature.
Printed copies of this document are not considered signed
and sealed and the SHA authentication code must be
verified on any electronic copies.
AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2
THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR. EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN(
OUR WRITTEN APPROVAL.