Loading...
HomeMy WebLinkAboutdestiny reportm' 'uIn-Place Density Report Client: Project: & Associates, Inc. Permit # 2009-0474 Renar Development Corp. 113-15-66-5434B Report Date: 11/30/2020 3725 S. East Ocean Boulevard, Suite 101 Morningside Residential Lots Port St. Lucie Branch Test Method: ASTM D6938 Stuart, FL 34996 Fort Pierce Florida Registration No. 5950 - Fort Pierce, FL 460 NW Concourse Place, Unit 1 y��y� / 7 Port e: 772Lucie,78-0072 9, ,,{ � � � �� �� " Phone:772-878-0072 - Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture % Maximum ` Dry Density (pcf) In Place Moisture % In Place Dry Density pcf) In Place Wet Density pcf) Probe Depth (in) Percent Compaction Min Comp. (% Remark 382 11/30/20 20-280 (Modified) A 10.5 117.0 8.2 115.7 125.2 12 99 95 Pass 383 11/30/20 20-280 Modified A -- 10.5 117.0 7.9 113.8 122.8 12 97 95 Pass 384 11/30/20 20-280 (Modified) A - 10.5 117.0 8.8 116.0 126.2 12 99 95 Pass 385 11/30/20 20-280 (Modified) A -- 10.5 117.0 9.7 115.4 126.6 12 99 95 Pass 386 11/30/20 20-280 (Modified) A -- 10.5 117.0 13.1 111.4 126.0 12 95 95 Pass 387 11/30/20 20-280 (Modified) A 10.5 117.0 12.9 112.6 127.1 12 96 95 Pass 388 11/30/20 20-280 (Modified) A -- 10.5 117.0 13.8 114.4 130.2 12 98 95 Pass 389 11 /30/20 1 20-280 (Modified) A -- 10.5 117.0 1.1.6 114.9 128.2 12 98 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 382 Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. NE Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 383 Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. SE Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 384 Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. SW Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 385 Building Pad Fill: House Pad for Lot 54 at 9605 Rainwood Court. NW Corner -1.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 386 Footings: House Pad for Lot 54 at 9605 Rainwood Court. N Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 387 Footings: House Pad for Lot 54 at 9605 Rainwood Court. S Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 388 Footings: House Pad for Lot 54 at 9605 Rainwood Court. W Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie 389 Footings: House Pad for Lot 54 at 9605 Rainwood Court. E Footing -2.0 Top of Subgrade Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments rass.-Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. & Associates, Inc. Permit # 2009-0474 Report Date: 11/30/2020 Port St. Lucie Branch Test Method: ASTM D6938 Florida Registration No. 5950 - 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 fflE �;, r In -Place Density Report client: Renar Development Corp. 3725 S. East Ocean Boulevard, Suite 101 Stuart, FL 34996 Project: 113-15-66-5434B Morningside Residential Lots Fort Pierce Fort Pierce, FL This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Dec 01, 2020 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 2 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR. EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.