HomeMy WebLinkAbout2nd Lift Compaction TestHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
November 13, 2020 KSM JOB # :205499-2d/CH/jo
CONTRACTOR:South Florida Land Clearing
15701 Orange Avenue
Fort Pierce, Florida
JOB LOCATION:2951 S. Brocksmith Road
Fort Pierce, Florida
PERMIT #:
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Julie E. Keller, P.E.
President
PE # 68366 11/13/20
Email to: sflcgw@gmail.com
Proudly Serving Florida since 1990
Enclosed, please find the nuclear density test results performed on the 2nd & 3rd lifts of compacted foundation
fill at the above referenced project.
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
11/12/2020 KSM JOB # :205499-2d/CH/jo
NUC #417
South Florida Land Clearing Nuc Model:3500
2951 S. Brocksmith Road Nuc Serial #:3417
Fort Pierce, Florida
Compacted Foundation Fill - 2nd & 3rd Lifts
#TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
1 N.E.12" - 24"45 109.2 113.0 96.6%
2 S.E."47 109.9 "97.3%
3 Center "45 108.7 "96.2%
4 N.W.24" - 36"40 108.2 "95.8%
5 S.W."47 110.1 "97.4%
6 Center "47 109.5 "96.9%
Proctor Optimum Moisture:
@ Test Locations the Density &
11/13/2020
Proudly Serving Florida since 1990
PE # 68366
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
ITEM TESTED:
Degree of Compaction Meets
Minimum Requirement
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
Soil Description:
Brown Sand with some
Shell
In Place Moisture:
Proctor Max. Dry Density: P.C.F.
11.0%
11.8%
Disclaimer:Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction
test.KSM is not responsible if the tested area
has been altered from the approved inspected
condition
113.0
Penetrometer reading indicate the
Julie E. Keller, P.E.
President
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:11/12/2020 KSM JOB # :205499-2d/CH/jo
PERMIT #:
CONTRACTOR:South Florida Land Clearing
JOB LOCATION:2951 S. Brocksmith Road
Fort Pierce, Florida
Soil Description:
Brown Sand with some
Shell
Proctor Optimum Moisture:
11.0%
Proctor Max. Dry Density: P.C.F.
113.0
Julie E. Keller, P.E.
President
PE # 68366 11/13/2020
SOIL COMPACTION REPORT
ASTM D 1557
Proudly Serving Florida since 1990
110.0
111.0
112.0
113.0
114.0
8 9 10 11 12 13 14
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight