December 3, 2020 KSM JOB # :205499-5d/CH/ct
CONTRACTOR:South Florida Land Clearing
15701 Orange Avenue
Fort Pierce, Florida
JOB LOCATION:2951 S. Brocksmith Road
Fort Pierce, Florida
PERMIT #:
To Whom it may concern,
Should you have any question, please feel free to contact our office.
Respectfully,
Julie E. Keller, P.E.
President
PE # 68366 12/03/20
Email to: sflcgw@gmail.com
Enclosed, please find the nuclear density test results performed on the final lift of compacted foundation fill at
the above referenced project.
Proudly Serving Florida since 1990
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
12/2/20 KSM JOB # :205499-5d/CH/ct
NUC #417
South Florida Land Clearing Nuc Model:3500
2951 S. Brocksmith Road Nuc Serial #:3417
Fort Pierce, Florida
Compacted Foundation Fill - Final Lift
#TEST LOCATION
OF SAMPLE DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F.)
PERCENT
COMPACTION
1 N.E.48" - 60"45+110.7 113.0 98.0%
2 S.E.""110.1 "97.4%
3 Center ""109.9 "97.3%
4 N.W.""110.3 "97.6%
5 S.W.""109.7 "97.1%
Proctor Optimum Moisture:
@ Test Locations the Density &
12/3/2020
Proudly Serving Florida since 1990
PE # 68366
DATE TESTED:
PERMIT #:
CONTRACTOR:
JOB LOCATION:
ITEM TESTED:
Degree of Compaction Meets
Minimum Requirement
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
Soil Description:
Brown Sand with
Some Shell
In Place Moisture:
Proctor Max. Dry Density: P.C.F.
11.0%
13.2%
Disclaimer:Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction
test.KSM is not responsible if the tested area
has been altered from the approved inspected
condition
113.0
Penetrometer reading indicate the
for Unstaked Foundation
Julie E. Keller, P.E.
President
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:12/2/20 KSM JOB # :205499-5d/CH/ct
PERMIT #:
CONTRACTOR:South Florida Land Clearing
JOB LOCATION:2951 S. Brocksmith Road
Fort Pierce, Florida
Soil Description:
Brown Sand with
Some Shell
Proctor Optimum Moisture:
11.0%
Proctor Max. Dry Density: P.C.F.
113.0
Julie E. Keller, P.E.
President
PE # 68366 12/3/2020
SOIL COMPACTION REPORT
ASTM D 1557
Proudly Serving Florida since 1990
110.0
111.0
112.0
113.0