Loading...
HomeMy WebLinkAbout3rd Lift Compaction TestHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net November 20, 2020 KSM JOB # :205499-3d/CH/ct CONTRACTOR:South Florida Land Clearing 15701 Orange Avenue Fort Pierce, Florida JOB LOCATION:2951 S. Brocksmith Road Fort Pierce, Florida PERMIT #: To Whom it may concern, Should you have any question, please feel free to contact our office. Respectfully, Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 11/20/20 Email to: sflcgw@gmail.com Enclosed, please find the nuclear density test results performed on the fourth lift of compacted foundation fill at the above referenced project. Proudly Serving Florida since 1990 Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net 11/19/20 KSM JOB # :205499-3d/CH/ct NUC #417 South Florida Land Clearing Nuc Model:3500 2951 S. Brocksmith Road Nuc Serial #:3417 Fort Pierce, Florida Compacted Foundation Fill - 4th Lift #TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F.) PERCENT COMPACTION 1 N.E.36" - 48"45 110.7 113.0 98.0% 2 S.E."45 111.0 "98.2% 3 Center "45 110.1 "97.4% Proctor Optimum Moisture: @ Test Locations the Density & 11/20/2020 Proudly Serving Florida since 1990 PE # 81439 DATE TESTED: PERMIT #: CONTRACTOR: JOB LOCATION: ITEM TESTED: Degree of Compaction Meets Minimum Requirement SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 Soil Description: Brown Sand with some Shell In Place Moisture: Proctor Max. Dry Density: P.C.F. 11.0% 12.8% Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. 113.0 Penetrometer reading indicate the for Unstaked Foundation Bryan E. Dahlke, P.E. V.P. of Engineering Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:11/19/20 KSM JOB # :205499-3d/CH/ct PERMIT #: CONTRACTOR:South Florida Land Clearing JOB LOCATION:2951 S. Brocksmith Road Fort Pierce, Florida Soil Description: Brown Sand with some Shell Proctor Optimum Moisture: 11.0% Proctor Max. Dry Density: P.C.F. 113.0 Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 11/20/2020 SOIL COMPACTION REPORT ASTM D 1557 Proudly Serving Florida since 1990 110.0 111.0 112.0 113.0 114.0 8 9 10 11 12 13 14 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight