Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's
�:ORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation -Residential Performance Method Project Name: 51 OAOOAG Melody RHG-E Builder Name: One Stop Cooling and Heating Street: 5112 Silver oak Dr Permit Office: St.Lucie File Copy City,State,Zip: Fort Pierce,FL,.,829A8 3�Ieqy�- Permit Number: Owner: Maronda Homes Jurisdiction: 661000 Design Location: FL,MELBOURNE_REGIONAL_AP County:: st.lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1997.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1633.30 ft2 b. Frame-Wood,Adjacent R=11.0 364.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (2068.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 2068.00 ft2 6. Conditioned floor area above grade(ft2) 2068 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7.-Windows(162.0 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 413.2 a. U-Factor: Dbl,U=0.34 161.98 ft2 SHGC: SHGC=0.23 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 29.0 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 27.6 HSPF:8.20 SHGC:Area Weighted Average Overhang Depth: 3.963 ft. Area Weighted Average SHGC: 0.230 14.Hot water systems * 8. Floor Types (2068.0 sgft.) Insulation Area a. Electric Cap:50 gallons EF:0.900 a.Slab-On-Grade Edge Insulation R=0.0 2068.00 ft2 b. Conservation features b. N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.078 Total Proposed Modified Loads: 64.14 PASS Total Baseline Loads: 64.33 HE S I hereby certify that the plans andspecifications covered by Review of the plans and `S T,q"'• ` O � this calculation are in complian e the Florida Energy specifications covered by this o. Code. calculation indicates compliance c� �igfEY with the Florida Energy Code. +4 bri;. ;.;, �`'�„ O PREPARED 0. B� : Before construction is completed .'tj>;^z DATE: Z this building will be inspected for O I l l�l •.;. compliance with Section 553.908 *• =�- ` .. I herebycertify that this b ' 'n , as designed,is in co li ce Florida Statutes. ' Y 9 P with the Florida Energy C de. OWNER/AG BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. ' -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 2/7/2017 4:56 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 } FORM R405-2014 PROJECT Title: 51 OA00AG Melody RHG-E Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 2068 Lot# 510 Owner: Maronda Homes Total Stories: 1 Block/SubDivision: Port St.Lucie #of Units: 1 Worst Case: No PlatBook: Builder Name: One Stop Cooling and Heatin Rotate Angle: 0 Street: 5112 Silver oak Dr Permit Office: St.Lucie Cross Ventilation: No County: st.lucie Jurisdiction: 661000 Whole House Fan: No City,State,Zip: Fort Pierce, Family Type: Single-family FL, 32908 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,MELBOURNE_REGI FL_MELBOURNE_REGI 2 45 90 70 75 369 69 Medium BLOCKS Number Name Area Volume 1 Blockl 2068 19232.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2068 19232.4 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 1 ft 0 2068 ft2 ---- 0.29 0 0.71 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 2313 ft2 518 ft2 Dark 0.7 N 0.7 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 2068 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2068 ft2 0.1 Wood = 2/7/2017 4:56 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block-Int Insul Main 4.1 57 0 9 4 532.0 ft2 0 0 0.8 0 2 E Exterior Concrete Block-Int Insul Main 4.1 20 6 9 4 191.3 ft2 0 0 0.8 0 3 S Exterior Concrete Block-Int Insul Main 4.1 47 6 9 4 443.3 ft2 0 0 0.8 0 4 W Exterior Concrete Block-Int Insul Main 4.1 50 0 9 4 466.7 ft2 0 0 0.8 0 5 - Garage Frame-Wood Main 11 39 0 9 4 364.0 ft2 0 0.25 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Main None .4 3 8 24 ft2 2 Wood Main None .46 2 8 8 21.3 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 n 1 Vinyl Low-E Double Yes 0.34 0.23 16.4 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 2 e 2 Vinyl Low-E Double Yes 0.34 0.23 32.7 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 3 s 3 Vinyl Low-E Double Yes 0.34 0.23 32.7 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 w 4 Vinyl Low-E Double Yes 0.34 0.23 7.5 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 5 w 4 Vinyl Low-E Double Yes 0.34 0.23 32.7 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 W 4 Vinyl Low-E Double Yes 0.34 0.23 40.0 ft2 13 ft 0 in 1 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 595 ft2 595 ft2 61 ft 8.67 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000295 1602.7 87.99 165.47 .2157 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.2 27:6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 29 kBtu/hr 870 cfm 0.75 1 sys#1 = 2/7/2017 4:56 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model# Collector Model# Area Volume * FEF None None ftz DUCTS / ----Supply--- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 413.2 ft Main 103.3 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May rl Jun Jul Auge Oct Nov Dec Heatin X]Jan Feb Mar f Apr f May Jun Jul Aug SeP Oct Nov H DecVentin 1]Jan Feb Mar [X]A r [ Ma Jun [ Jul [ Au [ Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 - 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 = 2/7/2017 4:56 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. 5112 Silver oak Dr, Fort Pierce, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1633.30 it- b.Frame-Wood,Adjacent R=11.0 364.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2068.00 ftz 6. Conditioned floor area(ftz) 2068 b.N/A R= ftz 7. Windows" Description Area c.N/A R= ft z a. U-Factor: Dbl,U=0.34 161.98 ftz 11.Ducts R ft a.Sup:Attic, Ret:Main,AH:Main 6 413.2 SHGC: SHGC=0.23 b. U-Factor: N/A ftz SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 29.0 SEER:15.00 _ SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 27.6 HSPF:8.20 Area Weighted Average Overhang Depth: 3.963 ft. Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14.Hot water systems z a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 2068.00 ft EF:0.9 b. N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new Display Card will be completed based on installed Co omp Ian ea ure Builder Signature: f Date: . 0/1 Address of New Home: S S , City/FL Zip: , *Note: This is not.a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/7/2017 4:56 PM EnergyGauge RO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 �1 Project S Job: 51OA00AG Melody RHG Summary -... wrightSoft® Y Date: 02/07/2017 Entire House By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 • • • For: Maronda Homes 5112 Silver oak Dr, Fort Pierce, FL N otes: Desian Information Weather: Orlando Intl AP FL US Winter Design Conditions Summer Design Conditions Outside db 42'°F Outside db 92 OF Inside db 68 OF Inside db 74 OF Design TD 26 OF Design TD 18 OF Daily range M Relative humidity 50 % Moisture difference 49 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18115 Btuh Structure 15522 Btuh Ducts 1961 Btuh Ducts 4064 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20077 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 19076 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2700 Btuh Ducts 872 Btuh Heatingg coolin�gg Central vent (0 cfm) 0 Btuh Area(ft2 2077 2077 Equipment latent load 3572 Btuh Volume(ft3) 19303 19303 Air changes/hour 0.32 0.16 Equipment total load 22649 Btuh Equiv.AVF (cfm) 103 51 Req. total capacity at 0.75 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model CH14NBO300000A Cond CH14NB0300000A AHRI ref 7835535 Coil FX4DNF037L AHRI ref 7835535 Efficiency 8.2 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 21750 Btuh Heating output 27600 Btuh @ 470F Latent cooling 7250 Btuh Temperature rise 0 OF Total cooling 29000 Btuh Actual air flow 0 cfm Actual air flow 967 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=9 kW, Output=29982 Btuh, 100 AFUE Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t Wrl IItSOft' 2017-Feb-0716:51:39 � g Right-Suite®Universal 2017 17.0.10 RSU16202 Page 1 ...00AG Melody RHG-EX51OA00AG Melody RHG-E.rup Cale=MJ8 Front Door faces: E - -wrightsoftm Right-M Worksheet Job: 51OA00AG Melody RHG-E Entire House Date: 02/07/2017 • By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAG032444 1 Room name Entire House MBED 2 Exposed wall 174.9 ft 31.5 It 3 Room height 9.3 ft d 9.3 ft heat/cool 4 Room dimensions 1.0 x 268.0 ft 5 Room area 2077.3 ftz 268.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ftz) Load number (Btuh/ftz-°F) (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A 400s, 0:143 n 3.79. - 2.90 442 409 1527, 1165 0 0 _ 0 0 v 4A5_ Oc340 n 8.87r 9.91, 33 0 290__ 324 _0 0: 0._ 0: 13A-4ocs 0.143 a 3.73 290 191 134 500 388 0 0 0 0 4A5-2ov 0.340 a 8.87 25.52 33 0 290 834 0 0 0 0 11 11D0 0.390 a 10.18 12.27 24 24 244 _ 294 0 _ 0 _ 0 0 J� 13A-4ocs 0.143 s 3.73._ 2:90 530 .514- 1918- 1486- 140' 140 521 404, ; 4A5-2ov -0,340-s - 8.87 10 1_2 16. - 14 _ 145 -1.85_ `0. 0 0 0 13A-4ocs 0.143 w 3.73 2.90 465 385 1436 1114 153 121 451 350 �G 4A5-2ov 0.340 w 8.87 25.52 8 0 67 191 0 0 0 0 IL-_CG 4A5-2ov 0.340 w 8.87 25.52 33 0 290 834 33 0 290 834 4A5-2ovd 0.340 w 8_87 9.91 40_ 40-- 357 398 0 0 0 0 12G 0sw 0.091 2:38 1 51 363 347 823 '522 -0-6 0 0 1 36 -. 0,390 n" 10;18 12:27, 6__ 16 iti3 196___0 0_-0. 0 C 1613-30ad 0.032 - 0,84 1.76 12 12 10 22 0 - 0 0 0 ,C-�16CR30ad A 032-':0_84 1.44 2065 2065 1725 2970 268 268 224 385 F 22A_tpm 1.180 0.00 0_00_ 12 0 0 0 0 0 0 _ 0 22A_tpm_ _� 1:180=; 30.80 _6760_ 2065.;�175 5387 _0 268 32__ 970. "0 -- - I-- - - -- �, 6 c)AED excursion 709 289 Envelope loss/gain 15171 11634 2455 2262 12 a) Infiltration 2944 1038 530 187 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 1700 0 Subtotal(lines 6 to 13) 18115 15522 29851 2909 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 6 10 14 Subtotal 18115 15522 2992 2919 15 Duct loads 11% 26% 1961 4064 11%, 26% 324 764 Total room load 20077 19586 3315 3683 Air required(cfm) 01 967 0 182 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W wrightsoft- 2017-Feb-07 16:51:39 ,lack Right-Suite®Universal 2017 17.0.10 RSU16202 Page 1 ...00AG Melody RHG-E\51OAOOAG Melody RHG-E.rup Calc=MJ8 Front Door faces: E -rF wrightsoftm Right-M Worksheet Job: 510A00AG Melody RHG-E Entire House Date: 02/07/2017 By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name MBTH MWIC 2 Exposed wall 11.0 ft 17.0 ft 3 Room height 9.3 It heat/cool 9.3 It heat/cool 4 Room dimensions 11.0 x 11.5 ft 8.0 x 9.0 ft 5 Room area 126.5 ft2 720 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btutdft2-°F) (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Coal Gross N/P/S Heat Cool 6 13A-4ocs 0..143 n- 3.73 2.90 0 0 0 0 84 j84 312 242 4A5 2ov 0;340 i� _ _887. 9.91 0.. 0I i 0-_0 ,`0_ 0 0-- 13A-4ocs 0.143 a 3.73 2-90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 a 8.87 25.52 0 0 0 0 0 0 0 0 11 11 DO 0.390 a 10.18 12.27 0 0 0 0 0 0 0 0 13A=4ocs '' 0.'143 s 3.73' 2.90 0 0 0 0. _0 0" 0 0 4A5-ov 0.340__s___8.87, 10J2 0. 0 '0 0 0 0 0 0 ' VVV���!!! 13A-4ocs 0.143 w 3.73 290 102 95 354 275 74 74 278 215 4A5-2ov 0.340 w 8.87 25.52 8 0 67 191 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A -2ovd 0.340 w 8.87 9.91 0_ 0 0 0 0 0 0 0 -�--- 12C-0sw ! O;091' 1 2 38 1.617 T 0 0 i0 0 A t) 0 0; 11_DO _ 0 390_n_� 1018. 12.27 0'-,0 0 0: 0 0_ 0_ 6 C 166_30ad� 0_032=_ 0.84 1.76 0 0_ 0 0-0-0-0 0 ,16(5R-30ad 0 032 _0 84 1.44 127 11227 1,0____�182 72 72 60 104 F 22A-tpm 1.180 0_00 ;0_00 0 0 0 0 0_ 0 0 0 F 22A=tpm_ 1:180 _�30.6Q 0_00 12_-7 1,1 _339 0 _ 72 17 524_ 0 ------------ 77 I ----------- -----1 6 c)AED excursion 60 -36 Envelope loss/gain 865 708 1174 526 12 a) Infiltration 185 65 286 101 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1050 773 1460 627 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1050 773 1460 627 15 Du 1 11% 26%1 114 202 11% 26%1 158 164 Total room load 1164 976 1618 791 Air required(cfm) 0 48 of 39 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t= -►p- wrightsoft- 2017-Feb-07 16:51:39 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 2 ...00AG Melody RHG-E\510A00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E - -wrightsoft• Right-M Worksheet Job: 51OA00AG Melody RHG-E Date: 2017 By: I/mc Entire House RI/imc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name BED3 BTH 2 Exposed wall 14.9 ft 0 ft 3 Room height 9.3 It heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 171.8 ft 6.5 x 9.5 ft 5 Room area 171.8 ft2 61.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool _-� -- - 6 Vf/ 13A-gocs 0..1 n 3,73, 2 90 14Q 123 460 357 0- 0 0 0 - _ 4A5_2oy 0.34_0 _n :_8_87- _9 9], _1.6.,_ 0_ __1_45_ 162. 0 0 Q 0_ 13A-4ocs 0.143 a 3.73 2-90 0 0 0 0 0 0 0 0 4A5.2ov 0.340 a 8.87 25.52 0 0 0 0 0 0 0 0 11 I-D 11DO 0.390 a 10.18 12.27 0 0_ 0 0 0 0 0 0 1.3A flocs 0143 s 3.73. 290 :0 0 0-'-"'0 0 0 0, 0 4A5-2ov _A3O s_ 8.8.7, 10.12 0 _.0 0 0 --_0 �0 0- 0- 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2ovd 0.340 w 8.87 9.91 0 0 0 0 0 0 0 0 12C-0sw q T 0091 � 238- 1 51, 0 0 0 0 0 0 0 0, 11D0.� i0390 1018�12_27_ 0 '0__ I 0 0 Q 0 . 0 C 16B_30ad 0 032= 0.84 1 76-___ 0- 0 0 0 0 0 0_ 0 C 16CR 0:0 0.84 .1.44 172 172 143_ 247 .62 62. .52 89' F 22A tptpm 1.180 0.00_0.00 0 0 0 0 0 0 0 0 1;180_ =1=30 80 _0:00 ;�17.2� '15 459 0_ 62 '0: TO==V s 6 c)AED excursion -58 -5 Envelope loss/gain 1208 707 52 100 12 a) Infiltration 252 89 0b) Room ventilation 0 0 0 13 Internal gains: Occupants Ca 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1460 1026 52 84 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 7 12 15 24 14 Subtotal 1467 1038 67 108 15 Duct loads 11% 26% 159 272 11% 26% 7 28 Total room load 1626 1310 74 137 Air required(cfm) 0 65 I 0 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 't" wrightsoft' 2017-Feb-07 16:51:39 Right-Suite®Universal P017 17.0.10 RSU16202 Page 3 ...00AG Melody RHG-E151OA00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E +wrightsoftm Right-M Worksheet Job: 51OA00AG Melody RHG-E Entire House Date: 02/07/2017 By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter.Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name GREAT NOOK 2 Exposed wall 41.5 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 It heat/cool 4 Room dimensions 1.0 x 457.8 ft 10.5 x 9.5 It 5 Room area 457.8 ft2 99.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftz°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-400s 6.143 n - 3.73,- ',0- 0.- 0 0, 0 6 0 - 0, 4A5-2ov, _---_---_- 0.340-n_.--8 87`9.91. _0 _---_ 0 _-_-0 _-. 'd-__0-____0 13A-4ocs 0.143 a 3.73 296 0 0 0 0 0 0 0 0 4A5-2ov 0.340 a 8.87 25:52 0 0 0 0 0 0 0 0 11 11D0 0.390 a 10.18 _ 12.27 0 0 0 0 0 0 0 0 yy// 13A-4ocs ---- 0.143 s 3.73 2.90- 251 ---235 -- 876 - 680 ---^0 0 0 -- 0.340-s__--8._87•-10.12-__1.6 -__.14_-_�145 __ 165 0 _0 0- 0 13A-4ocs 0.143 w 3.73 2.90 135 95 353 274 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2o_vd 0.340 w- -___8_87 9_91 __--40 - 40--_357_ 398 _- 0 T_-0 0 -0 12Gosw j 0.091. 2.38 1.51, 0, 0 .0 0 0 0 0 0 0.390 _n - 10.1a 12,27____ _,0-__0.-_- 0 ___0 -_____0____ Q r---_0_ ,Q _C ___ 1_66_30ad___ 0.032-- _ 0_84 1. 6-- 0 -_ -, 0 _-_ 0___0 0-_-0-- 0.--- 0 C __16CR-30ad __-.__0�032 _; --Q_84 1.44-_ 458 458_ 382. 658 _ 100_-100�_B- 143 F 22A-tpm __ 1.180 --0_00 __-0.00 0 0_-_ 0 0_ 0 _ 0 _- 0 T- 0 tpm- 1.180_ ._,_,30.$0,.=0,06,.458-___-42 - 127$ 0-_100 -' 6 ___0__-_0 --_------- �-i --- -- -- - -- - - -- - --- -------------- 6 c)AED excursion 582 -8 Envelope loss/gain 3392 2758 83 136 12 a) Infiltration 698 246 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Qa 230 0 0 0 0 Appliances/other 101 0 Subtotal(lines 6 to 13) 4090 3005 83 136 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 11 17 14 Subtotal 4090 3005 94 153 15 Duct loads 11% 26% 443 787 11%1 269/6 101 40 Total room load 4533 3791 104 193 Air required(cfm) I I 10 187 1 1 0 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Feb-07 16:51:39 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 4 ...00AG Melody RHG-E\510A00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E - - wrightaoftm Right-M Worksheet Job: 51OA00AG Melody RHG-E Entire House Date: 02/07/2017 By: RIlmc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name KIT LDRY 2 Exposed wall 0 ft 0 ft 3 Room height 9.3 ft heat/cool 9.3 It heat/cool 4 Room dimensions 1.0 x 217.5 ft 1.0 x 65.8 It 5 Room area 217.5 ft2 65.8 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftZ°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y% 13Q-4 U. n 3.73 ocs 2.90 0 0 0 0 0 0 0 0 �. . 4A5i2ov - -- ----_0340-0- --_8.87_ -___0----0 ---- ----0 ___0 ------0--- --0 --0------0 13A-4ocs 0.143 a 3.73 2.90 0 0 0 0 0 0 0 0 I-G 4A5-2ov 0.340 a 8.87 25.52 0 0 0 0 0 0 0 0 11 !-D 11 DO 0.390 _e 10.18 12.27 0 0 0 0 0 0 0 0 13'A-4ocs -T - - 0.1- 5 3.73 2.90-- 0 _ - 0 --- 0 --- 0 0----0 -0 - 0 _G 4A5 2o_v__- _ -0.340-sue- S_87 _10.12_____0 _--_0 ___0 ___0__ 0 VU13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-20v 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5_2ovd 0_340_ w 8_87-9.91 -__ 0 0- 0-_-- 0 0 ____0 _- 0 0 R 12C 0sw 0.091 3.3_, 1.51 11.6. 116 276 '175. 60 44 106 67, 1-D 11D0_ _-_ __ -._0.390_ Rj__ 10.18 12_.27 __-_0 -0-.__-_0_ ___0 _ -16 _- 1,8 --163 195 C 16B_30ad-- _-_- 0.032 _-__ _ 0,84 _ 1.76 -- 0 ____ 0-_ 0___ 0 _ 0._- 0. 0 _ 0 G 16CR-30ad 0.032- _- -__0_84 -1.44_- 218 -_ 218 -___182 ____313 6- _66 55 __K F 22A-tpm 1.1180 _ -0.00 -0.00_- 0 -0._- _ 0'___ 0._ -- 0 0_- 0 0 - 0 ___::o, _---_ 6 c AED excursion -91 - -46 Envelope loss/gain 458 397 323 312 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1200 500 Subtotal(lines 6 to 13) 458 1597 323 812 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 10 16 12 22 14 Subtotal 467 1613 335 834 15 Duc[loads 1 11%1 261/6 51 422 11..1 26% 36 218 Total room load 518 2035 372 1052 Air required(cfm) 01 100 0 52 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. q wrightsoft' 2017-Feb-07 16:51:89 _ siCCP. F Right-Suite®Universal 2017.17.0.10 RSU16202 Page 5 ..00AG Melody RHG-E\51OA00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E -FIB wrightsof#' Right-JO Worksheet Job: 51OA00AG Melody RHG-E Entire House Date: 02/07/2017 By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name BED2 HALL 2 Exposed wall 15.5 ft 0 ft 3 Room height 9.3 It heat/cool 9.3 ft heat/cool 4 Room dimensions 1.0 x 189.3 ft 1.0 x 79.5 It 5 Room area 189.3 ftz 79.5 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ftz) Load number (Btuh/ftZ°F) (Btul1/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool --- --- - 6 W 13A-flocs 0.143 n 3.73' 2.90 144"-128 477 370 0 0 - 0 0. ;�-_ 4A5 2ov_------ 0.340 n__-8.87_ -_9:91._-_ 16-- -- ----1 ---_i 62 ---0 - - 13A-4ocs 0.143 a 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 a 8.87 25.52 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.18_ 12.27 0 0 0 0 0 0 0 0 T 13A-4ocs - -- -- 0.143 s 3,73 2.90 -- 0 0---- '0 --_ 0 - ' 0 ----0 0 -- '0 �G. 4A5 2ov -_ 0.340_s_-_8.87-_10.-2_-___-0--_0 --.,0__--__0 -_ 0 --0-____0- --__0 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5-2ovd 0.340 w _ 8.87 9.91 0. 0 0 0_--0 _-_0 _ 0 0 RR 12C-0sw -- - 0.091 2.38 1.51 - 121;-121 287 182. 0 .0 - 0 ----0 `L> 11D0_--_-e -10.10,__ 12:27 Q -0 ---0- ---'0- -0--- 0 ----�- -._-Q C 1613-30ad 0.032 _ _ 0.84 1.76 __ 0 _ 0 _ __0 0 0 _ 0 _ 0 _ _ 0 16CR-30ad ___ _ __'0�032_____0_84_ 1_44._ _189__ _189-___158 ___ -272 __- _ _80 66 --114 F - 22A-tpm_-_.-_ 1.18.0_ -0_00 _-0_00 --- 0 -0 ---0 - 0 -- 0 -_0._--_ 0 _- 0 1180 30.80 _-0.00- _:189 16.-__ 477-`_0 ,- 80 :0.-,_-0. 6 c)AED excursion -70 -6 Envelope loss/gain 1545 916 66 108 12 a) Infiltration 261 92 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1805 1238 66 108 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 16 27 -66 -108 14 Subtotal 1821 1265 0 0 15 Duct loads 11% 26% 197 331 11% 269/6 0 0 Total room load 2018 1596 0 0 0 79 0 0 Air required(cfm) Calculations approved by.ACCA to meet all requirements of Manual J 8th Ed. -f[1- wrightsoft- 2017-Feb-0716:51:39 .4CCP. Right-Suite®Universal 2017 17.0.10 RSU16202 Page 6 ...00AG Melody RHG-E151OA00AG Melody RHG-E.rup Cale=MJ8 Front Door faces: E L 51O 0AG -9 wrightsoft, Right-M Worksheet Job: 02I/0 12017 Melody RHG-E - Entire House Date: 7/ 017 ' By: R/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name FOY FLEX/DEN 2 Exposed wall 6.5 It 37.0 If 3 Room height 9.3 ft heat/cool 9.3 It heat/cool 4 Room dimensions 6.5 x 7.0 ft 14.0 x 15.0 If 5 Room area 45.5 ftz 210.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftZ°F) (Btuh/ftq or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4aos !- 0.143 n .. 3.73, - 2.90 0 0 0 0 74 74 278 215 _L_G; 4A5.2ov O.W-n-: -_-8.87;__-_9:91 ---_-.0 --__0 - --Q.--- ----Q----0 0 --- -0 13A-4ocs 0.143 a 3.73 2.90 60 36 136 106 130 98 364 282 4A5-2ov 0.340 a 8.87 25.52 0 0 0 0 33 0 290 834 11 T:fD 11 DO 0.390 a 10.18 12.27 24 24 244 294 0 0 0 0 VV��/ 13A flocs -'- -- - 0.143 s 3.73 f 290 -- 0 --- 0 -- 0 0 140 - 140 521 404 !L G A-M5 toy --- Q340--s- -- S_87_ 10.12 -- ---0 -----0- ----0- --0---0 - - --=0 WWW 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 - 0 0 0 0 0 0 -- 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 0 0 0 0 4A5_2ovd 0.340 w 8_87 9.91 _ 0 _ _ 0 0 0____- 0 - _ 0 0 0 R 12C-Osw - 069- 2.38 1.51, 65 - 65 -155 98 0 Of 0 - 0 _ 0.390 n__ 10.1$ 12 2.7, -----0 _____0 __-__0__-_- 0 --_ _ 0 _ __-0 -__ _0 -OA32__. _0.84, 1.76 0 __-- -_-- 0 ---0-__-- 0 _-__-0--- 16CR-30ad _ _ 0.032-__ 0_841�44 '48 _-__ 46-_ 38 __- 65 _- 210 210_ - 175 302 _ _ 0 -_ 0_- _0 -_ 0 --0 1_160 30.80_ --0,00 -^ 46 -_-,-7 _-_-200 _._-0 __210- -___37 -1140 --__0_ , - _.-i - 6 c)AED excursion -32 130 Envelope loss/gain 773 531 2767 2168 12 a) Infiltration 109 39 623 219 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ga 230 0 0 1 230 Appliances/other 0 0 Subtotal(lines 6 to 13) 883 570 3390 2617 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 883 570 3390 2617 151 Duct loads 1 11% 261/6 96 149 11% 26%1 367 685 Total room load 978 719 3757 3302 Air required(cfm) 0 35 0 163 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightSOft- 2017-Feb-0716:51:39 ACCP. Right-Suite®Universal 2017 17.0.10 RSU16202 Page 7 ..00AG Melody RHG-E151OA00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E - - wrightsoftm Right-J®Worksheet Job: 510A00AG Melody RHG-E Entire House Date: 02/07/2017 By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL'32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 1 Room name 2 Exposed wall 0 ft 3 Room height 8.0 It heat/cool 4 Room dimensions 3.5 x 3.5 ft 5 Room area 12.3 ft? Ty Construction U-value Or HTM Area (ft2) Load Area Load number (Btuh/ftz°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs 0.143 n 3.73 2.90 A 4A5_2ov_ _ 0.340 n_;— 8 87.__9:9_f 0, ;0_ _0 13A-4ocs 0.143 a 3.73 2.90 0 0 0 0 �I 4A5-2ov 0.340 a 8.87 25.52 0 0 0 0 V 11 6 11 DO _ 0.390 a 10.18 12.27__ 0_ 0 0 0 _ y! 13A-4ocs 0.143 s 3.73 2:90 0 0 ' 0 0 - L—(af 4A5 2ov Q:340_s__,8:87, 1012__0__d 0 0 Ti 13A-4ocs 0.143 w 3.73 2.90 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 4A5-2ov 0.340 w 8.87 25.52 0 0 0 0 4A5.2ovd 0.340 w 8.87 9.91 0 0 0 0 Rq 12C-0sw -0.091 2.38, ' 1.51. 0 0 '0 .0 12.27 0 _ _0 C 1613_30ad 0 Q32 0.84, 1.76. 12 12 10, C_-- 16CR 30ad� 0.032 =T 0.84 1.44 0 0 0 0�� + F 22A-tpm 1.180 0.00 0.00 12 0 0_ 0 22 _ F A_tpm 'LA80. __30 80_0.00 0—�0 0 0 - -1— -------------- ---------- 6 c)AED excursion -1 Envelope loss/gain 10 20 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 1ntemal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 10 20 Less external load 0 0 Less transfer 0 0 Redistribution -10 -20 14 Subtotal 0 0 1151 Duct loads 13% 469%1 0 0 Total room load 0 0 Air required(cfm) 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. FIJ wrightsoft- 2017-Feb-0716:51:39 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 8 ...00AG Melody RHG-E\51OA00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E Duct System Summary Job: 51OA00AG Melody RHG wrightsofts Date: 02/07/2017 Entire House By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 Projectl6formation For: Maronda Homes 5112 Silver oak Dr, Fort Pierce, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.16 in H2O 0.16 in H2O Available static pressure 0.34 in H2O 0.34 in H2O Supply/ return available pressure 0.170/0.170 in H2O 0.170/0.170 in H2O Lowest friction rate 0.251 in/100ft 0.251 in/100ft Actual air flow 0 cfm 967 cfm Total effective length (TEL) 135 ft P ,Ply Brdnc,h Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk BED2 c 1596 0 79 0.454 6.0 Ox 0 VIFx 4.9 70.0 BED3 c 1310 0 65 0.269 6.0 Ox 0 VIFx 26.3 100.0 st2 BTH C 137 0 7 0.270 4.0 Ox 0 ViFx 25.9 100.0 st2 FLEX/DEN C 3302 0 163 0.256 7.0 Ox 0 VIFx 33.0 100.0 sti FOY c 719 0 35 0.270 4.0 Ox 0 VIFx 30.7 95.0 sti GREAT C 1896 0 94 0.265 6.0 Ox 0 VIFx 28.2 100.0 st1 GREAT-A c 1896 0 94 0.251 6.0 Ox 0 VIFx 35.2 100.0 sti KIT c 2035 0 100 0.265 6.0 Ox 0 VIFx 28.2 100.0 sti LDRY C 1052 0 52 0.472 4.0 Ox 0 VIFx 2.0 70.0 MBED c 3683 0 182 0.280 7.0 Ox 0 VIFx 26.5 95.0 st2 MBTH C 976 0 48 0.269 5.0 Ox 0 VIFx 26.3 100.0 st2 MWIC C 791 0 39 0.259 4.0 Ox 0 VIFx 31.5 100.0 st2 NOOK C 193 0 10 0.266 4.0 Ox 0 VIFx 27.8 100.0 st2 -pu • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk sti Peak AVF 0 486 0.251 619 12.0 0 x 0 VinlFlx st2 Peak AVF 0 350 0.259 792 9.0 0 x 0 VinlFlx Bold/italic values have been manually overridden t WCIhtsoft° 2017-Feb-0716:51:40 �. 9 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 1 ACCA ...00AG Melody RHG-E\51OA00AG Melody RHG-E.rup Calc=MJ8 Front Door faces: E • Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox 0 0 967 0 0 0 0 Ox 0 VIFx I.1 F1tSOft' 2017-Feb-07 16:51:40 W �CA 9 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 2 ..00AG Melody RHG-E\51OA00AG Melody RHG-E.rup Cale=MJ8 Front Door faces: E Static Pressure and Friction Rate Job: 510A00AG Melody RHG-... wrightsoft® Date: 02/07/2017 Entire (douse By: RI/mc One Stop Cooling and Heating 7225 Sandscove Court,Winter Park,FL 32792 Phone:(407)629-6920 Fax:(407)629-9307 Web:www.OneStopCooling.com License:CAC032444 Projedt Inforniation For: Maronda Homes 5112 Silver oak Dr, Fort Pierce, FL • e.Static Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0.50 0.50 Pressurelosses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0.03 0.03 Return grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0.34 0.34 Total • Supply Return (ft) (ft) Measured length of run-out 13 0 Measured length of trunk 22 0 Equivalent length of fittings 100 0 Total length 135 0 Total effective length 135 Frictionflate Heating Cooling (in/10011) (in/100ft) Supply Ducts 0.251 >0.18 0.251 >0.18 Return Ducts 0.251 > 0.18 0.251 >0.18 Fitting Equivalent LengthOetails 4X=35, 11A=20, 11G=5, 1A=35, 11G=5:TotalEL=100 Return TotalEL=0 htsoft® 2017-Feb-0716:61:40 Wrl .4CCI1 9 Right-Suite®Universal 2017 17.0.10 RSU16202 Page 1 ..00AG Melody RHG-E\510AOOAG Melody RHG-E.rup Calc=MJ8 Front Door faces: E FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: 51 OAOOAG Melody RHG-E Builder Name: One Stop Cooling and Heating Street: 5112 Silver oak Dr Permit Office: St.Lucie City,State,Zip: Fort Pierce,FL,32908 Permit Number: ' Owner: Maronda Homes Jurisdiction: 661000 Design Location: FL,MELBOURNE_REGIONAL_AP COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. • Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors • 2/7/2017 4:56 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1