HomeMy WebLinkAboutProduct Approval (2) VALL
ZIP SYSTEM® SHEATHING WITH HARD COAT STUCCO AT
BLOCK FOUNDATION . H'2
WALL OPTION B
TRADITIONAL HARD-COAT STUCCO File Copy
INSTALLED IN ACCORDANCE WITH THE LATH :!
�r- MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC.(PCA) ONE LAYER OF WATER-RESISTIVE
- RECOMMENDATIONS WITH THE MOST VAPOR-PERMEABLE BARRIER
RESTRICTIVE CONTROLLLING. WITH A PERFORMANCE AT LEAST
EQUIVALENT TO GRADE D
" BUILDING PAPER
> DRAINAGE MEDIUM
>' (MIN.)"THICK)
ZIP SYSTEM®SHEATHING*
s
`c TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEM®TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR
AC148)
WOOD OR LT.GA.
METAL STUDS
_ ADHESIVE BACKED MEMBRANE
- ` BRIDGE FLASHING CENTERED
OVER TRANSITION JOINT(ZIP
SYSTEM TAPE MAY BE USED
AS THE BRIDGE FLASHING)
0
0
0
0
1•
4�•+`Y
CODE-APPROVED .+
WEEP SCREED AT
BASE OF WALL
VERTICAL AND HORIZONTAL
CONTROL JOINTS AS NEEDED.
DESIGNER-OF-RECORD TO
SPECIFY TYPE AND LOCATION.
MASONRY BLOCK WALL
*ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER WATER RESISTIVE SAQRI2R•'NG NOT TO SCALE
SYSTEM.
N TM Sales Oifice:10925 David Taylor Drive
Zlft gt*m
�a Suite 300-Charlotte,NC 28262 ENGINEERED
`o SHEATHING b TAPE B� WOODS
o Telephone:800.933.9220-www.zipsystem.Com
These construction detai s are provided to assist In the installation of IP System®product(s)and may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
' C
ZIP SYSTEM@ SHEATHING WITH HARD COAT STUCCO AT
H-2
BLOCK FOUNDATION WALL SECTION VIEW - OPTION B
WALL ASSEMBLY ;•
TRADITIONAL HARD-COAT STUCCO
r LATH i•
ONE LAYER WATER-RES.BARRIER
DRAINAGE PLANE(MIN. )G"THICK)
ZIP SYSTEMS SHEATHING'
WOOD OR LT.GA.METAL STUDS
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING. •'<.
(MUST MEET AAMA 711 OR
AC148) 4
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
oe
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM
TAPE MAY BE USED AS THE BRIDGE 1
FLASHING)
MASONRY BLOCK WALL = '
LATH
TOP EDGE OF WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP
SYSTEMS TAPE OR ADHESIVE BACKED
FLASHING. (MUST MEET AAMA 711 OR \ /
AC148)
MANUFACTURED FURRING STRIPS,
BATTONS OR CODE-RECOGNIZM
DRAINAGE MEDIUM(MIN. V THICK)
TRADITIONAL HARD-COAT STUCCO
INSTALLED IN ACCORDANCE WITH THE 1
MANUFACTURERS OR THE PORTLAND '
CEMENT ASSC.(PCA)
RECOMMENDATIONS W1TH THE MOST
RESTRICTIVE CONTROLLLING.
ONE LAYER OF WATER-RESISTIVE
VAPOR-PERMEABLE BARRIER WITH A ,
PERFORMANCE AT LEAST EQUIVALENT
TO GRADE D BUILDING PAPER. ,
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM .001*
TAPE MAY BE USED AS THE BRIDGE .�
FLASHING)
MASONRY BLOCK WALL
'ZIP SYSTEMS SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF A TWO-LAYER WATER RESIA&AMMOT TO SCALE
SYSTEM.
0 Y m+� Sales Office:10925 David Taylor Drive
% Suite 300_-Charlotte,NC 28262 �UB�� WOODS ENGINEERED
5 SHEATHING&TAPE Telephone:800.933.9220-www.zipsystem.com
These construction details are provided to assist in the installation of ZIP System®product s)and may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details. �'
ZIP SYSTEM@ SHEATHING WITH HARD COAT STUCCO AT
• H-2
BLOCK FOUNDATION WALL- OPTION A
TRADITIONAL HARD-COAT STUCCO LATH
INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC.(PCA)
RECOMMENDATIONS WITH THE MOST ONE LAYER OF WATER-RESISTIVE
RESTRICTIVE CONTROLLUNG. VAPOR-PERMEABLE BARRIER
WITH A PERFORMANCE,•:t` ':'':` EQUIVALENTTTOGRAD AT LEAST
GRADE
_ BUILDING PAPER
ZIP SYSTEM®SHEATHING'
•t TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEM®TAPE OR
`;':,:,:• '• ADHESIVE BACKED FLASHING.
i•,.• (MUST MEET AAMA 711 OR
AC148)
WOOD OR LT.GA.
'i
METAL STUDS
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED
OVER TRANSITION JOINT(ZIP
SYSTEM TAPE MAY BE USED AS
'•;,�±•• THE BRIDGE FLASHING)
0
0
0
0
CODE-APPROVED
- WEEP SCREED AT
BASE OF WALL
+i
VERTICAL AND HORIZONTAL }y.
CONTROL JOINTS AS NEEDED.
DESIGNER-OF-RECORD TO `
SPECIFY TYPE AND LOCATION. -�~
MASONRY BLOCK WALL
*ZIP SYSTEM®SHEATHING IS APPROVED TO REPLACE ONLY THE
FIRST LAYER OF A TWO-LAYER UNDERLAYMENT SYSTEM.
DRAWING NOT TO SCALE
�►/�, Y �� Sales Office:10925 David Taylor Drive �'`n��
�l/ISYS Suite 300-Charlotte,NC 28262 U�V( Woocs EmGmEEREo
o SHEATHING S TAPE Telephone:800.933.9220-wwmApsystem.com
These construction etails are provided to assist in the insta lation of ZIP System pro uct s)and may not apply to
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.
o- • !r`t
ZIP SYSTEM@ SHEATHING WITH HARD COAT STUCCO AT
-BLOCK FOUNDATION WALL- OPTION A
H-2
WALL ASSEMBLY
TRADITIONAL HARD-COAT STUCCO
METAL LATH
ONE LAYER WATER-RES.BARRIER
i ZIP SYSTEMS SHEATHING'
WOOD OR LT.GA.METAL STUDS
TOP EDGE OF WEEP SCREED
TAPED TO WALL SHEATHING
WITH ZIP SYSTEMS TAPE OR
ADHESIVE BACKED FLASHING.
(MUST MEET AAMA 711 OR
AC148)
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM /
TAPE MAY BE USED AS THE BRIDGE
FLASHING)
MASONRY BLOCK WALL is
LATH
TOP EDGE OF WEEP SCREED TAPED
TO WALL SHEATHING WITH ZIP
SYSTEMS TAPE OR ADHESIVE BACKED \
FLASHING. (MUST MEET AAMA 711 OR
AC148) \`
TRADITIONAL HARD-COAT STUCCO
INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S OR THE PORTLAND
CEMENT ASSC.(PCA)
RECOMMENDATIONS WITH THE MOST 1
RESTRICTIVE CONTROLLLING.
ONE LAYER OF WATER-RESISTIVE
VAPOR-PERMEABLE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT Li
TO GRADE D BUILDING PAPER.
CODE-APPROVED WEEP
SCREED AT BASE OF WALL
ADHESIVE BACKED MEMBRANE
BRIDGE FLASHING CENTERED OVER
TRANSITION JOINT(ZIP SYSTEM
TAPE MAY BE USED AS THE BRIDGE
FLASHING)
MASONRY BLOCK WALL '-
*ZIP SYSTEMS SHEATHING IS APPROVED TO REPLACE ONLY THE FIRST LAYER OF ATWO-LAYER UNDERLAYMEN'f's'MPT TO SCALE
Sales Office:10925 David Taylor Drive
ENGINEERED
Suite 300-Charlotte,NC 28262
SHEATHING S TAPE WOODS
o Telephone:600.933.9220-www.zipsystem.coin
These construction details are provided to assist in the installation of ZIP System proqcts)anUdm0:taPP1yt0
every situation. Manufacturer accepts no responsibility or liability for the use of these or other construction details.