Loading...
HomeMy WebLinkAboutMobile Home Inspection Reports (for relation only) St Lucie County Building & Zoning \ 7 M 2300 Virginia Avenue ' Ft Pierce. FL 34982 Mobile Home Inspection Report All requests for permits to place or replace used Mobile/Manufactured homes must be accompanied by this w completed Inspection Report and copies of both sides of the Title to the home. All used Mobile homes must be Wind Zone II certified. Owner: I J� L �3 !�l Date: a 7 A(P�rint or type) c�/ �j� � 1 Fi— Address: LdT 387 /V L'rrLCS BLyp , `/�.51:'/�iC�H 3,Y 957 hysical Location of Home) Year/Manufacturer 'L(:� Serial#rL-P�79��9(o1s��to# '—a'A" JI / ' Width I Length ` Single Double V Wind Zone • C= In Compliance N= Not in-Compliance Fire Safety/ Electrical G 1. Smoke Detector: Installed YFi: Missing C 2. Electrical System Checked: Exposed Wiring Other 3. Distribution Panel: Missing Loose Main Missing Breaker Missing Unplugged Opening Other C 4. Electrical Fixtures: Missing Installed Improperly Improperly Wired Loose Wire GFCI receptacles not where required G5. Electrical Ground: Chassis Main Panel Gas Pipe 5 ' Revised 3i9i05 Page 1 of 3 Construction C 1. Exit Doors Operable: Front Back Other C 2. Exit Door Locks: Missing Inoperable G 3. Egress windows: Missing Inoperable 4.Windows: Broken Glass Inoperable C 5. Screens:Missing Damaged 6. Floor System:Joist Decking Area Damaged 7. Interior Paneling: Missing Loose Damaged 8. Rodent Proofing: Bottom Board Pipe openings Other 9. Leaks Apparent: Ceiling Doors Floor Roof C 10. Vertical tie-down straps: Missing Short Damaged C 11. Structural modifications since manufactured:YES_ NO_✓ _(12. Walls:Structurally Unsound Loose Weather tight Plumbing G 1. Trap: Missing Not connected Other 2. Plumbing fixtures: Missing Not installed Not Vented G 3. Relief Valve: Missing Inoperable Other 4.Drain Waste and Venting Piping:Missing Not supported Clean outs Use of fittings Not capped Heating and Air Conditioning C 1. Heating Appliances: Missing Not Connected Other 2. Deleted Heating/AC system: Not installed Other _ 3. Thermostat: Missing Inoperable �i 4. Air registers: Missing Inoperable C 5. Ducts: Not sealed Missing Collapsed Page 2 of 3 r.,L i ati w � L 6. Gas furnace Water heater vent: Missing Loose 7. Return Air:To Furnace To A/C From rooms _ 8. Range:Vent Hood 9. Gas Valve:Accessible Installed improperly 10. Gas lines: Not capped Not supported Kinked Not bonded Summary / 1. Is subject structure found to be fifty(50%)or more damaged or deteriorated? YES NO V 2. Willa remodeling permit be required? YES NO__V/— The provisions of the repair and remodeling code shall ensure safe and livable housing and shall not be more stringent than those standards required to be met in the manufacture of mobile homes. Such provisions shall include, but not be limited to,standards for structural adequacy,plumbing, heating, electrical systems,and fire and life safety. FS 320.8232 IF ANY RENOVATIONS OR IMPROVEMENTS OVER AND ABOVE THE REQUIREMENTS OF FS 320.8232 ARE TO BE PERFORMED ON ANY MOBILE HOME WHICH WILL BE PERMITTED TO BE TIED-DOWN IN ST. LUCIE COUNTY, A SEPARATE PERMIT WITH ENGINEERING (IF APPLICABLE)WILL BE REQUIRED. ALL SEPARATE PERMITS MUST OBTAIN A FINAL INSPECTION BEFORE A FINAL INSPECTION IS OBTAINED FOR THE TIE-DOWN PERMIT. NO MOBILE HOME WILL BE ALLOWED TO BE MOVED TO ST. LUCIE COUNTY OR RE- LOCATED WITHIN ST. LUCIE COUNTY UNTIL THE REQUIRED DOCUMENTS HAVE BEEN SUBMITTED, REVIEWED, APPROVED AND THE TIE-DOWN PERMIT HAS BEEN ISSUED. A REGISTERED FLORIDA PROFESSIONAL ENGINEER MUST COMPLETE THIS DOCUMENT,SIGN AND AFFIX THEIR SEAL. Date inspected: C�A, p Inspected By: J D r.�� License 3 # �J Signature,requited pZ/��l r Phone Number.: / Engineers Seal Page 3 of 3 STEVEN G.WOOD,P.E. ]FL LICENSE$4398 9go SULTAN DR t FORT ITT LUCIE,FL