HomeMy WebLinkAboutApproved Plansr GENERAL NOTES: 1. TO BE CONSTRUCTED IN ACCORDANCE WITH :FLORIDA BUILDIN() CODE, 5TH EDITION, 2014 & ASCE 7-10 2. DESIGN COMPLIES WITH THE 2014 FLORIDA BUILDING CODE FOR THE 170 MPH ULTIMATE AND 132 MPH NOMINAL WIND SPEED, RUSK CATEGORY 11, EXPOSURE B AND ENCLOSED OR PARTIALLY ENCLOSED MANUFACTURED BUILDING. DESIGN COMPLIES WITH THE FOUNDATION REQUIREMENTS OF SECTION R322.2 OF THE 2014 FLORIDA RESIDENTIAL BUILDING CODE. DESIGN IS NOT APPROVED, WITHOUT SITE -SPECIFIC EVALUATION AND MODIFICATION, FOR FEMA FLOOD ZONE V OR AREAS DEFINED AS "COASTAL" OR WIND EXPOSURE D. OTHFR DESIGN LOADS ARE: 20 PSF ROOF LIVE LOAD AND 40 PSF FLOOR LIVE LOAD. 3. SOIL BEARING CAPACITY IS ASSUMED TO BEAT LEAST 1500 PSF IF THE ACTUAL_ BEARING CAPACITY IS LESS THAN 1500 PSF, IT MUST BE REPORTED TO THE ENGINEER PRIOR TO COMMENCING WORK. 4. ALL FOUNDATION CONSTRUCTION, MATERIALS AND INSTALLATION, SHALL BE IN ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES, INCLUDING DMV, SEC. 15C. 5. DESIGN IS BASED ON SET-UP ON AND ANCHORAGE TO EXISTING OR NEW SLAB, 5" MINIMUM THICKNESS AND TOTAL CONTINUOUSLY REINFORCED AREA EQUAL TO, OR GREATER THAN, THE FLOOR AREA OF THE MANUFACTURED BUILDING; OR ANCHORAGE DIRECTLY TO THE GROUND. 6. ALL PIERS SHALL BE CONSTRUCTED OF 8"X 8"X 16" OR 4"X 8"X 1611 CONCRETE MASONRY UNITS, SOLID OR HOLLOW CORE, CONFORMING TO ASTM C90, TYPE I, GRADE N-1, NORMAL WEIGHT. MORTAR IS NOT REQUIRED. CONCRETE FOR BASES SHALL BE 2500 PSI, MINIMUM STRENGTH. 7. ALL PIERS SHALL BE TOPPED WITH NO. 2 SYP 2"X 8" PRESSURE TREATED SILL PLATES THE FULL LENGTH OF THE PIER. S. DETAILS OF PIER LOCATION AND SPACING SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION PLAN FOR THE SPECIFIC BUILDING TO BE SET ON THE FOUNDATION. 9. TYPE A PIERS MAY BE INSTALLED LATERALLY (90 DEGREES FROM THE ORIENTATION SHOWN ON THE FOUNDATION PLAN. CENTERLINE OF EACH PIER MUST BE LOCATED DIRECTLY BELOW THE I -BEAM CENTERLINE. 10. TYPE B PIERS SHALL BE SUBSTITUTED FOR TYPE A PIERS WHERE THE SET-UP REQUIREMENTS WOULD RESULT IN THE NEED FOR A PIER HEIGHT GREATER THAN 40" OR WHEN LOCATI D IN FEMA FLOOD ZONE A. 11. THE USE OF TYPE B PIERS THROUGHOUT AND TIE -DOWNS AS SHOWN AND SPECIFIED HEREIN WILL PROVIDE A FOUNDATION AND ANCHORAGE WHICH WILL PREVENT FLOTATION, COLLAPSE OR LATERAL MOVEMENT, AND WILL FACILITATE THE UNIMPEDED MOVEMENT OF FLOOD WATERS. THIS CONSTRUCTION SHALL NOT RESULT IN ANY INCREASE IN FLOOD LEVELS. 12, TIE -DOWN STRAPS SHALL BE CERTIFIED BY THE MANUFACTURER FOR A MINIMUM WORKING LOAD OF 3,150 POUNDS TENSION. INSTALL STRAPS AND ANCHORS PER MANUFACTURERR'S INSTRUCTIONS. 13. CONCRETE SLAB ANCHORS SHALL BE MODEL MICS2 AS MANUFACTURED BY TIE DOWN ENGINEERING, ATLANTA, GEORGIA, OR EQUAL. SLOTTED STRAP BOLTS SHALL BE TIE DO'/VN ENGINEERING MODEL BISB, SQUARE SHOULDER BOLTS, OR EQUAL. SLAB ANCHORS MAY BE USED TOTALLY OR PARTIALLY WHERE THE SLAB QUALIFIES. SEE #5 ABOVE. 14. EARTH, OR AUGER, ANCHORS SHALL BE MODEL ML2H, AS MANUFACTURED BY TIE DOWN ENGINEERING, ATLANTA, GEORGIA, OR EQUAL. THE ULTIMATE LOAD CAPACITY, AS CERTIFIED BY THE MANUFACTURER, MUST EQUAL OR EXCEED 4,725 POUNDS. INSTALLATION SHALL BE PER MANUFACTURER'S INSTRUCTIONS. 15. ADDITIONAL BLOCKING OR TIE -DOWNS SHALL BE INSTALLED IF AND AS REQUIRED BY THE HOME MANUFACTURER, 16. THE TYPE A AND TYPE B PIERS, AS DETAILED ON THESE DRAWINGS, MAY BE USED IN CONJUNCTION WITH ANY STATE APPROVED TIE -DOWN AND ANCHORING SYSTEM. 17. "B" TYPE PIERS ON GROUND OR SLAB AT 36" MAX HT. SHALL BE USED THROUGHOUT IN FLOOD ZONE "A", "B" PIERS AS SHOWN, INCLUDE TIE DOWN STRAPS AND ANCHORS, COMPLIES WITH THE FEMA FLOOD PLAIN MANAGEMENT REGULATIONS. FOR MANUFACTURED HOMES. Br* t #;�-d5z c.. _" A.S . - 7��G st+tf�_tSf4 VN=4 4 M c>f`tA/�w' tN t•t *— �; 4AK7'w f^AKRY' r T MLTICAL" Tt N AW,kAr �&_ SA. F`l 1%* "B" TYPE PIER ON GROUND: SCALE N.T.S. NO. DRWN. CHKD, APPVD. DATE REVISION DESCRIPTION _ 0 BPD BPD BPD 4/5/17 ISSUED FOR CONSTRUCTION NO. DRWN. CHKD. AM DATE SLAB, 5" MIN. tit s A, tA-VMN"tiK A -h� L46VL—F-.`.t.- =0•r 11`44 L(w("1'°a "A" TYPE PIER ON GROUND: SCALE N.T.S. *:.xTd ezf4 C.. Mw _ _.n.~ .. .- 0 - s r .. AD RAID 1344 W/ 8" DIA. WEDGE ANCHOR,OR APPROVED EQUAL SLAB, 5" MIN. LLA" TYPE PIER ON SLAB SCALE N.T.S. FVISION DESCRIF IOP, NO. DRWN, CHKD, APPVD.j DATE "Xv A -A ■" TYPE PIER ON ■ SCALE N.T.S REVISION DESCRIPTION r V MIN. TYP. 6'-3" MIN. 21.9' PER SURVEY 6-3" MIN. H Q co 00 i I � I I I (! I I �;I d - - - - - - - ---- II �— f I w U jI "A" TYPE PIER, TYPICAL UNDER EACH m O I -BEAM EXCEPT IN FLOOD ZONE, SHALL -1 BE TYPE "B" c) Z LL Q O�w - - _, -- -..I d0 I O I L'I O ZO U I I� I � � I I a❑ I { I (n Q I i -- "B" TYPE IER, TYPICAL AT MARRIAGE I LINE COLUMNS AND EACH SIDE OF 1 I ! OPENINGS > 4 FT. IF SITE IS LOCATED ( IN FLOOD ZONE ALLIPIERS SHA L BE "B" ( TYI'E. I � _ I I "MARRIAGE LINE"Wall woo - f /I I a l I I I I I I 1 I I I I I II I I I I I I II I I I I THESE PLANS AND ALL PROPOSE K PIER. D.EA I L� A MAYBRED-BY SARYYINCORDER� 1- E NECE —�vo.r,EB-0Y HELzB-INSPECTORS ARESUBJECTT� , TYPE Ip CQMKY WITH ALL APPLICASLS C V�RTICAL I&DOWN ! I (TYP.) I I I I L - ---- _ - -! - - - _ - C-CEglEO FASTEN AREIWERESPONSIBIITYFIT ONITS CONTRACTOR OFt�ECOno 0�1 � Mel,ovs �Y 9T.Lucll IIU_ N.D lGDIVlv l!p*. 3 f (11N�PRCTION WILL BE MADE. N JOB FOUNDATION PLAN: SCALE 8 = 1 -Qfl O www.dovis i"xcm BOVEN RESIDENSE DAVIS NCONSULTING & ENGINEERING, LLC TERRACE (772) 444-6323 687 NETTLES BLVD. JENSEN BEACH, FLORIDA 34957 FLORIDA CA# 31680 JENEN BEACH, FLORIDA34957 17049 MANUFACTURED BUILDINGS i _ wD P� Ne: FOUNDATION PLAN AND DETAILS �'N^ "001 �� Dw,WIDc vie it FILE COPY