USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL17184-R3
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Plastpro Inc./Nanya Plastics Corp.
Address/Phone/Email 5200 W CENTURY BLVD.
r LOS ANGELES,CA 90045
(440)969-9773 Ext 16
rickw@rwbldgconsultants.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative Scott Johnson
Address/Phone/Email 5200 W Century Blvd.
Los Angeles,CA 90045
(440) 969-9773 Ext 18
scottjohnson@plastproinc.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Lyndon F.Schmidt,P.E.
the Evaluation Report
Florida License PE-43409
Quality Assurance Entity National Accreditation&Management Institute
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King,P.E.
C✓ Validation Checklist-Hardcopy Received
Certificate of Independence FL17184 R3 COI Certificate of Independence.odf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2005
ASTM E1886 2005
ASTM E1886 2002
ASTM E1996 2002
ASTM E1996 2006
ASTM E1996 2005
ASTM E330 2002
TAS 201, 202, 203 1994
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3EapiI1B W... 3/10/2017
Florida Building Code Online Page 3 of 5
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.6 for any additional use limitations, FL17184 R3 AE EVAL 17184.6.0df
installation instructions and product particulars. Created by Independent Third Party: Yes
17184.7 g. Fiberglass Door Up to a 3'0 x 8'0 Glazed"Non-Impact" Fiberglass Single
Door with a Sidelite (OX or XO Configurations)
Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.7.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.7 for any additional use limitations, FL17184 R3 AE EVAL 17184.7.1)df
installation instructions and product particulars. Created by Independent Third Party: Yes
17184.8 h. Fiberglass Door Up to a 3'0 x 8'0 Glazed"Non-Impact" Fiberglass Single
Door with Sidelites(OXO Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.8.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.8 for any additional use limitations, FI 17184 R3 AE EVAL 17184.8.pdf
installation instructions and product particulars. Created by Independent Third Party:Yes
i
17184.9 i. Fiberglass Door Up to 6'0 x 8'0 Glazed"No n-Impact"Fiberglass Double Door
(XX Configuration) Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.9 for any additional use limitations, FL17184 .R3 AE EVAL 17184.9.1)df
installation instructions and product particulars. Created by Independent Third Party: Yes
17184.10 j. Fiberglass Door Up to a 6'0 x 8'0 Glazed"Non-Impact"Fiberglass Double
Door with Sidelites(OXXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.10.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 17184.10 for any additional use FL17184 R3 AE EVAL 17184.10.pdf
limitations, installation instructions and product particulars. Created by Independent Third Party: Yes
17184.11 rkFberglass Door Up to a 3'0 x 6'8 Opaque"Impact"Fiberglass Single Door(X
Configuration)Inswing/Outswing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.11.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 17184.11 for any additional use FL17184 R3 AE EVAL 17184.11.pdf
limitations,installation instructions and product particulars. Created by Independent Third Party:Yes
17184.12 I. Fiberglass Door Up to a 3'0 x 6'8 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OX o r XO Configurations)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 11 INST 17184.12.odf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 17184.12 for any additional use FL17184 R3 AE EVAL 17184,12.pdf
limitations, installation instructions and product particulars. Created by Independent Third Party:Yes
17184.13 m. Fiberglass Door Up to a 3'0 x 68 Opaque"Impact"Fiberglass Single Door
with a Sidelite(OXO Configuration)Inswing/Outs wing
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL17184 R3 II INST 17184.13.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other: See INST 17184.13 for any additional use FL17184 R3 AE EVAL 17184.13.pdf
limitations, installation instructions and product particulars. Created by Independent Third Party:Yes
17184.14 n. Fiberglass Door
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvCo3EapiIlB W... 3/10/2017
plastpro
5200 W. CENTURY BLVD. Z `o?� o
LOSANGELES, CA 90045
m U N
v 9 Z a
37.0'MAX.OVERALL \` a ^n °° m
FRAME WIDTH V Y o m a.,a v
O d
OPAQUE FIBERGLASS DOOR 9Z
INSWING/OUTSWING
o �a
w
"IMPACT"
z
GENERAL NOTES 3 n�
1 This product has been evaluated and is in compliance with the 5th Edition(2014)Florida o w
3 03
Building Code tFBC)structural requirements excluding the"High Velocity Hurricane Zone" _
R (HVHZ).
= i o �EL
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to w a a o
base material shall be beyond wall dressing or stucco.
< X °°
3. When used in areas requiring wind bome debris protection this product complies with Section w
1609.1.2 of the FBC and does not require an impact resistant covering.This product meets o p
missile level"O"and includes Wind Zone 4 as defined in ASTM E 1996 and Section 1609.1.2.2 of < <
> the FBC. $ a N z
3
4. For 2x stud framing construction,anchoring of these units shall be the some as that shown for w o
2x buck masonry construction.
5. Site conditions that deviate from the details of this drawing require further engineering analysis
by a licensed engineer or registered architect. a
'o a
� U
N N
$ TABLE OF CONTENTS ^w
N<[ F
c HEE ST# DESCRIPTION " u
as OVERAC1 DESIGN PRESSURE jPSP):;'
o I Typical elevation,design pressures,&general notes , - d o
SWING FRAME z o
2 poor panel details DATE: 8/25/14 i
w DIMENSION POSITIVE 'NEGATIVE::'
z 3 Horizontal cross sections "" o
sca.E: N.T.S.
g 4 VerYicalcrosssections INSWING 3750"x82.00" +65.0 -70.0 s
a 5 Buck and frame anchor ng-2X buck masonry construction DWG.BY: AL m
Frameanchoon 1Xbuckmoso construction CHK.NG LFS 3
6 g rvy OUTSW(NG 37.50"x 80.50" +65.0 -65.0 CHK.BY.
ND.:
7 Bill of materials&components e
a FL—17T84.11
0
eSHEET 1— 7
z
R'Clients\Plastpro,Inc PERMANENT\Florida Product Approvals\F1-17184\C-Drawings\Current\FL-17184.11-.20.dwg,2.1
79.25"MAX.DOOR PANEL HEIGHT—
N� W
T0M2
mOx N N 0
V
A
0
A
D
m
n
_ R
m O 1
-�/
chi C, `� O
O
a ti .O
$m zz v- {'n mO w t7 0 O
NA as €� ♦I
rn
m Ci w
� o ,
_ �
V O 0
�m
—
Isz
w r
n m Ce 4
y
m
rt
�rnXC
N N rn
rn -
TJ A
rn A A N
�
7ry0 may.
N
to
rn
rn
n z
O 70
Z p
5
No.43409
Documents Prepored By:
PRODUCT: FCOMDP.•' ��w x m PLASTPRO Lyndon F. Schmidt ij ••• ��
"I FIBERGLASS DOOR P.E. No. 43409
IT V o Z PART OR ASSEM1IBLY: ��rt T BUILDING CONSULTANTS, INC.
Cn a. ut� 1 04/22 15 UPDATE TO 5TH ED. (2014) FSC JK DOOR PANEL DETAILS - /P.O. Box 230, Volrico, FL 33595
T N0. DATE BY Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813 ,
CU 2014 R.W.OUILnING CONSULTANTS INC.
R:\Clients\Plastpro,Inc PERMANENT\FlDrida Product Approvals\FL-17184\C-Drawings\Current\FL-17184.11-.20.dwg,3.1
w A
°Ae
e n
W� �
O
gN 2
C) n �J—
I r-
fl N "'2
O
o
O 1+
Z o
m
Z X
m m 4
O 0
all,
0
x a
A 11 [a] A N
O aka
W W W N
Z
M M
O O
ww
0_
00
m 70 V
O N
M .M X Z O
O O
. iTl iT1 F -4 J
tS� V
°Oa
p V n D �i
z ' Z
O r 0 de
�o m c
I V O
C
N �
m
� O
0
CH
p ? 7 o v
m-
F-? No.43409 _
�. yzi.rr �'0'•
i " y PRODUCT: D...—tc prepared By:�
'-1 r— � •"•' PLASiPRO Lyndon F. Schmidt �j/FS••• `�j�\
IL' I .mom. FIBERGLASS DOOR P.E. No. 43409
V o Z N //� �71711111\\�`
PART OR ASSEMBLY: �/���(/BUILDING CONSULTANTS, INC.
IV _ r- N 1 04 22 75 UPDATE 70 57N ED. (2014) FBC �K HORIZONTAL CROSS SECTIONS J ( P.O. Box 230, VDlrico, FL 33595
N0. DATE BY Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813
0 2014 R.W.6UILDIND CDNBl1LTANTA IND,
R.\Clients\Plastpro,fnc PERMANENT\Florida Product Approvals\FL-17184\C-Drawings\Current\FL-17184.11-.20.dwg,4.1
m
m
w
A � � A O
T �T1 O °
,p w i,.r
0 n '0 r 4°
0 n �O
CL A
Cg y m
n o �m
O °
Z � z
w
e
0.16'
cl C'SINK —
(TYP.(
1-1/4"MIN.
1-1/4"MIN. EMB.(TYP.)
m
1-1/4"MIN.
rEMB.(TYP J N
rn_ g n
A
N O
X h
go
Z ><y
.p A rT1 n
0m m
A Mffy
°
r—
0 0 1-1/4"MIN.
B.(TYPJ
m
scil t7/
i
N0.43409
x PRODUCT: Documents Prepared By:' • �
PLASTPRO Lyndon F. Schmidt % s•. OR..... ..FIBERGLASS DOOR P.E. No. 43409 � =T`��
V o
T 00 t•- y PART OR ASSEMBLY: �/BUILDING CONSULTANTS, INC.
IP U1 i 04 22/15 UPDATE TO 5TN ED. (2014) FDC JK VERTICAL CROSS SECTIONS R�,1� P.O. Box 230, Volrico, FL 33595
� a' NO DATE BY Phone No.: 813.659.9197
REVISIONS. FBPE C.A. No. 9813
0 213 1 4 R.W.B-L....CON9u LT—INC. D
o B Z n
U). d fir;• vi"O1
LC < -�
rrl* o n °z°
TYP.HEAD TYP.HEAD& m a
&JAMBS MASONRY JAMBS o 9 o m
MASONRY N t o W
OPENING OPENING a n d g m
v c W
0
_1 E v°Z
X° u c J
FRAME ® Nz
O 10
z�
2X BUCK _ o =�E
X n" 00 U2
2X BUCK aE N�
m �>
p TYP.SILL ^O am `c`o
di
U ¢
O
o r VU
a m
iuu
m
1 4
V
c
BUCK ANCHORING HINGE JAMB FRAME ANCHORING STRIKE JAMB N
Masonry 2X buck construction Lo
0 0
V W �
CONCRETE ANCHOR NOTES: W
1.Concrete anchor locations at the corners may be adjusted to maintain the min.
edge distance to mortar joints.
2.Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to
a maintain the min.edge distance to mortarjoints,additional concrete anchors flA i
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded. 10 D
o
a 3. Concrete anchor table. N¢ a
ANCHOR ANCHOR MIN MIN CLEARANCE MIN CLEARANCE 10 L o m
TypE SIZE EMBEDMENT i..MASONRY TO ADJACENT'i M ❑ 0 0
Z EL)GE 'z ANCHOR o
ITW 10 DATC 8 25/14
TAPCON
® 1/4" 1.1/4" 2' 4^ 27 scuE: N.T.S. °
ELCO T�4•, 1.1/4" 7" 4" Owc,ev:
S ULTRACON HINGE DETAIL LATCH&DEADBOLTDETAIL cHK.BY. LFS 3
a WOOD SCREW INSTALLATION NOTES: DRAWING NO a
1.Maintain a minimum 5/8"edge distance,I"end distance,&1"o.c.spacing of °
FL-17184.11
wood screws to prevent the splitting of wood.
SHEEr 5 OF 7 ,a
V
N':7 Z rc'•:O�� o m
o N ..Z
TYP.HEAD& 1 m - s z°'i
ro MASONRY JAMBS 10 r c o 0 c w
OPENING
a T a m m a 0-
6
E 0
c0 (L�
� J R Lim
FRAME
HINGE DETAIL �
03z
mr-
O X0
a 00
r 1X BUCK
�
o S� w z�
F TYP. �
<am v ¢�
SILL z
�
U 0 Q
O �
o F-
' c L
m 28 a a
1 G o
U
i
G o
HINGE JAMB FRAME ANCHORING STRIKE JAMB o
Masonry I X buck construction " v
z
2 a o
CONCRETE ANCHOR NOTES: w
1.Concrete anchor locations at the corners may be adjusted to maintain the min.
edge distance to mortar joints. LATCH&DEADBOLT DETAIL o
2. Concrete anchor locations noted as'MAX.ON CENTER"must be adjusted to
maintain the min.edge distance to mortarjoints,additional concrete anchors
a may be required to ensure the"MAX.ON CENTER"dimension are not exceeded.
3. Concrete anchor table:
a° MIN CLEARANCE MIN CLEARANCE..: z
ANCHOR. ANCHOk ILtlN N a F
o TO MASONRY `.TO ADJACENT
TYPE SIZE: EMBEDMENT
ITW
z c
z TAPCON® T/A" 1-1/4" 2" 4" DATE: 8,725�14 2
tt ULTRACON®Co 1/4" 1-1/q" 1" 4" s�� N.T.S. 9
mvc,BY: AL m
o WOOD SCREW INSTALLATION NOTES: cHK.er: LFS 3
I.Maintain a minimum 518"edge distance,1"end distance,&I"o.c.spacing of
oRnwwc Ho.:
wood screws to prevent the splitting of wood. FL-17784.1 1
0
SHEET 6 OF J fy�
q •� O•�Jtin
BILL OF MATERIALS z �4.0 o
ITEM DESCRIPTION MATERIAL w-'•. y�j` z N M
A IX BUCK SG>=0.55 WOOD �i/� ''•. �(i��� >> °m
B 2X BUCK SG-0.55 WOOD z dm 6
C 1/4"MAX.SHIM SPACE 1711 1�m y ON ':Z
D 1/4"X 2,3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL a i i z
E MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI CONCRETE I v} o o m `o a
_301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 4.56" N 4.56" ^ a , 5 o t m
F I/4"X 2-1/4"PFH ELCO OR ITW CONCRETE SCREW STEEL I o c 6 m a a
G 3/16"X 3-1/4"PFH ITW CONCRETE SCREW STEEL
~ LL
H 1/4"X 3-1/4"PFH ITW CONCRETE SCREW STEEL u o z
C 41
J 1/4"X 3-3/4"PFH ELCO OR TTW CONCRETE SCREW STEEL o° d
L #10 X 2-1/2"PFH WOOD SCREW STEEL j
M #8 X 2-1/2"PFH WOOD SCREW STEEL
6 SEALANT SILICONE 20 PambAD&SIDE 21 P�EtyDb&SIuDmb o
7 WEATHERSTRIP FOAM oo ww
9 4"HINGE STEEL a� } o
10 #10 X 3/4"PFH WOOD SCREW STEEL CL
20 JAMBFINGER-JOINT-PINE WOOD °W N 0�
21 POLYFIBER COMPOSITE JAMB POLYFIBER mca
a 27 LATCH STRIKE PLATE STEEL uI mo
28 DEADBOLT PLATE STEEL
30 DOOR SWEEP
^� 31 OUTSWING THRESHOLD BY DLP(QOSH) ALUM./WOOD 4.56" 4;56"
33 INSWING THRESHOLD BY DLP(ISCS ALUM./WOOD m
e 40 DOOR PANEL-SEE DOOR PANEL DETAIL SHEET FOR CONSTRUCTION DETAILS
4I DOOR SKIN(MIN.0.075"THICK)PLATT-PRO/NANYA Fy=11,063 PSI MIN. FIBERGLASS
42 TOP.RAIL CELLULAR PVC — ^r
0 43 LATCH&HINGE STILE CELLULAR PVC z
44 REINFORCEMENT WOOD FOR LOCKS WOOD OUTSWING THRESHOLD ;, INSWING THRESHOLD
45 BOTTOM RAIL CELLULAR PVC 31 Q0.5HCS w
46 FOAM CORE POLYURETHANE
47 LATCH&HINGE STILE REINFORCEMENT LVL
b
w
z
- h a
\W z
v �0
O z
2 Z U
—E.- 8125114 i
SCALE- N.T.S. a
n DWG.Dr: AL m
c
e
CHKC BY. LFS 3
n
DRAVIINC NO.: �
FL-17184.11 °
5 0
6 .SHEEP 7 OF ]
z