HomeMy WebLinkAboutRevisions OFFICE USE ONLY: �] n
DATE FILED: PERMIT#
REVISION FEE: RECEIPT#
PLANNING & DEVELOPMENT SERVICES
Q BUILDING&CODE REGULATION DIVISION
® 2300 VIRGINIA AVENUE
--
FORT PIERCE,FL 34982-5652
-- (772)462-1553 FAX(772)462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
aVe
1. LOCATION/SIT
ADDRESS �Q
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
6 i j ' mow. ti Taw 4i) S t M efoll-I it + 'c
e
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT.#: ST.LUCIE COUNTY CERT.#:
BUSINESS NAME: tA J l +' n
QUALIFIERS NAME:
ADDRESS: 195() f
CITY: STATE: ZIP: I
PHONE(DAYTIME): j FAX:
4. OWNER/BUILDER INFORMATION:
NAME: 670,,,kA.
ADDRESS: a. e.
CITY: STATE: ZIP:
PHONE: FAX:
5. ARCHITECT/ENGINEER INFORMATION:
NAME:
ADDRESS:
CITY: STATE: ZIP:
PHONE(DAYTIME): FAX:
Revised 07/22/2014
File Copy
. � Nrt-!"v
BCIS Home I Lag In ;user&egtstrattOn Hoc Topics [ submit surcharge Stats&Facts Publications [ FBC Stall[ BCIS Site Map Links [ Search
dbpor
a _
Jjl , e; Product Approval
if t7[ USER:Public User .
Product Approval Menu>Product or Apphcatlon Search>Application Lkc>Application Detail
FL# FL19902
Application Type New
Code Version 2014
Application Status Approved
,lr
Comments
Archived ❑ .i ti.
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street,Suite 200
Louisville,KY 40202
(812)218-7342
dstermer@metaisales.us.com
Authorized Signature David Stermer 1'1��� o%ft
dstermer@metalsal��usTJc�OTCjr roL RL�nt ,{•T+Tc�I�I�N
Technical Representative
Address/Phone/Email )tdil+,M'IL�E'i L --`�`—
Quality Assurance Representative PLAMN9 -D T'EWATIT?O ST BE I TT ON JOB
Address/Phone/Email ORC 'EXTION WILL P,`
Category Roofing
Subcategory Metal Roofing
i
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
71 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Baia Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi,P.E.
`�i Validation Checklist-Hardcopy Received
i
Certificate of Independence FI 19902 RO COI Certificateindeoendence odf
Referenced Standard and Year(of Standard) Standard Year
UL 1897 2004
UL 580 2006
s
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 02113/2016
Date Validated 0 2/1812 0 1 6
Date Pending FSC Approval 02/22/2016
Date Approved 04/12/2016
Summary of Products
FL# Model,Number or Name Description
19902.1 5V-Crimp Min.26 ga.,24"wide through fastened roof panel over min.
15/32"thick plywood deck or 7/16"thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FI 19902 R0 II Eva 1uationReoortC2076 I.odf
Approved for use outside HVHZ:Yes Verified By:Bala Sockalingam,P.E.62240
Impact Resistant:N/A Created by Independent Third Party:Yes
Design Pressure:+N/A/-172.5 Evaluation Reports
Other:Uplift load of 30.0 psf at fastener spacing of 36"o.c. F 1 t2902 R0 AE EvaluationReoortC7076 i Ddf
and 172.5 psf at"fastener spacing of 6"o.c. Created by Independent Third Party:Yes
Back Nex
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phnne:850-487-1824
The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact$50.487.1395.-Pursuant to Section 455.275
(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The
emalis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,
please provide the Department with an email address which can be made avallable to the public.To determine if you are a licensee under Chapter 455,F-S.,please
dick tMm.
Product Approval Accepts:
od
9� tLtxl E
Credit Card
Safe
• EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA.5V-CRIMP PANEL'
FLORIDA BUILDING CODE 5TH EDITION (2014)
FLORIDA PRODUCT APPROVAL
FL 19902.1
ROOFING
: METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3,`'Street,Suite 200
Louisville,KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4290
Prepared By:
Bala Sockalingam,Ph.D.,P.E.
Florida Professional Engineer##62240
1216 N Lansing Ave.,Suite C
Tulsa, OIL 74106
Telephone: (918) 492-5992
FAX: (918)493-3568
This report consists of.
Evaluation Report(3 Pages including cover)
Installation Details (1 Page) AL(►o�i1j#
Load Span Table (1 Page) �1'`® COO . ..N�."�?�``�e
b m No 62240
*• �LU
pF .ct�
Report No. C2076-1 g ART Q;'.q
Date: 2.13.16 ®��oc• C O P��°��:�`
FL 19902.1
C2076-1
2.13.16
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24"wide coverage with(5) 1/2"high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 7/16" thick OSB or min. 15/32 thick plywood at max span of 24"
for new and existing constructions. Designed and installed as per FBC
2014.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and edges
Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1
Slope: 4/2:12 or greater in accordance with FBC 2014 Section 1507.4.2.
Design Uplift Pressure: 30.0 psf @ fastener spacing of 36" o.c.
(Factor of Safety=2) 172.5 psf @ fastener spacing of 6" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum of
3/8" and installed as per Metal Sales current installation procedure.
At panel ends @ 6" o.c. across panel width
At intennediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with UL580-06 `Uplift Resistance
of Roof Assemblies' & UL1897-04 `Uplift Tests for Roof Covering
Systems.'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. The design pressure for reduced fastener spacing may be
computed using rational analysis prepared by a Florida Professional
Engineer orbased on Metal Sales load span table. This evaluation report
is not applicable in High Velocity Hurricane Zone. Fire classification is
not within scope of this Evaluation Report. Refer to FBC 2014 Section
FL 19902.1
C2076-1
2.13.16
Page 3 of 3
1505 and current approved roofing materials directory or ASTM
E108/UL790 report from an accredited laboratory for fire ratings of this
product.
Supporting Documents: UL580& 1897 Test Reports
PRI Construction Materials Technologies
MSMC-017-02-01,Reporting Date 9/20/13
I
I
I
PANEL OVERLAP
5V-CRIMP
FASTENER AT PANEL FIAT
SEE DETAIL 2 / SEE DETAIL 1 REQUIRED FOR PANEL
A 'EKDS ONLY.
S
1 MINIMUM ATTACHMERT: FASTEtiER.SPACING AS PER
DESIGN UPLIFT LOAD TABLE
8d x 25_'LONG RING SHANK!TAIL
AS PER MANUFACTURER'S
SHALL 'S INSTALLED OR g8,x 2'LONG WOOD SCREIYS
AS PER MANUFACTURER'S INSTALLATION SPACED®6'O.C.IN THE FIELD
GUIDELINES
I[AT EDGES ?
MIN.'2X_WOOD RAFTER/JOIST/ a
TRUSS AT MAX. 24"O.C. ¢c
0 0
TYPICAL PANEL INSTALLATION X-SECTION
0 NQn
19-16 OR 910-14 VROCDSCREWS
�H
WITH SELF SEALING WASHER AT
I.QXLIUM_SPFCING OF 36'.O.C.: cam
n,�I
N=NO
///---5V-CRIMP
LAIN 26 GA.
Y�m
2
i
GENERAL NOTES: � a
y� 1.ARCHITECTURAL ROOF.PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
UNDERLAYL!EYT FLORIDA EUILOINC CODE(FEC). a 5oS
A OSS 7/1V THICK(MIN.)OR 2.ROOF PANELS SHALL BE MIN.26 GA.(L=0.019").EFFECTIVE COVERING u�3
DETAIL 1 PLYWOOD 15/32-THICK(MIN.) WIDTH OF'PAREL=24. ¢
3.THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING&-STRUCTURE AS z Y6s
SPECIFIED ON THIS DRAWING. z
4.REQUIRED DESIGN VEND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
19-16 OR 010-14"W'OODSCREVIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS � =�T
' WITH SELF SEALING WASHER AT ARE'GREATER THAN THE DESIGN UPLIFT PRESSURES SPECIFIED ON iHfS ORAWNG. a
"LWLIMU0.1 SPACING OF 36'O.C. S:ALL FASTENERS MUST BE N ACCORDANCE WITH THIS DRAVANG k THE FLORIDA �.
BUILDING COOS IF A DIFFERENCE OCCURS BETWEEN THE PAWN M u 4
RECUIRDAENTS OF THIS DRAWING-&THE CODE THE CODE 5HALC CONTROL
SV-CRIMP
6.RAFTERS/J0ISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
RJif! 26 GA REOUIREO FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
UNOERLAYMENT OSB 7/16"THICK(MIN.)OR �2 V1
DETAIL 2 PLYWOOD 15/32"THICK(L9N.) ssx w.
I � �
METAL SALES MANUFACTURING CORPORATION
26 GA.5V-CRIMP PANEL
Design Uplift Loads
Description Fastener Spacing Allowable Uplift
along panel length Load
(in) (psf)
5V-Cri1np Panel. 6 172.5
Min. 26 ga. -- --9 ---— - --- 120.0
12 90.0
Panel Fasteners --_--_—__"_--_ __ __15--.--_—" -- "--- _ 72.0
#9-16 or#10-14 hex head 18 _ 60.0
wood screws with sealed 21 51.4
washer ---------...----_-----__ _---------------:.-__�..----.._
-24 45.0
27
--- --33 -- -- -- 32.7
—_—_---- 36 30.0
Notes:
1. The bold numbers indicate design loads calculated from test data with safety factor of 2.
2. Panels must be installed as per Evaluation Report FL 19902.1 and Metal Sales current installation
procedure.
��0�4ii11BBB8/e®
�%% OCKAL/Al
b°�vQ••,�GE(�`5'�:••;Q�9 ®ems
ND g2240 °o
shecc
.01
0�`••'cC O `0F'e wee
1216 N Lansing Ave.,Suite C � BAAAOAeeBe®®' Bala Sockalingam,Ph.D.,P.E.
Tulsa,Ok 74106 FL 62240
918 492 5992
poridaBllilding Lode Online _https://www.floridabuilorgtpr/pr�jOU d. •. wGEVX...
.,,a ' �) f i � g a-•€ j" {. �! �;c.�:LLI„ter._
BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Unks Search
Busines
U-11K.71,
Product Approval
PrQfessionalUSER: blcUser
...
Product Aoorovat•tenu>praduG or Aoo6[atb aic >aonkatton Ust> Pam ion Detai
FL# -FL16048-113
- — Application Type Revision
Code Version 2014
Application Status Approved
ri
Comments
Archived
Product Manufacturer TRI-BUILT Roofing Products
Address/Phone/Email 9050 Louisiana Street
Merrillville,IN 46410
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Authorized Signature David Ruiz
david.ruiz@tribuiltmaterialsgroup.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmateriaisgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/16/2017
Validated By John W.Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL16048 R3 COI 2015 01 COI_Nieminen.pdf
Referenced Standard and Year(of Standard) Standard Year
ASTM D1970 2009
ASTM G155 2005
FRSA/TRI April 2012(04-12) 2012
TAS 103 1995
1 of 2 5/24/2016 9.58 AM
orida Building Code Online https://www.floridabuile.org/pr/pr_appjd.aspx?pamm=wGEVX...
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/08/2015
Date Validated 10/19/2015
Date Pending FBC Approval 10/21/2015
Date Approved 12/15/201S
Summary of Products
FL# 'Model,Number or Name Description
16048.1 _ TRI-BUILT Roof Underlayments Self-adhering,modified bitumen roof underlayments
:Limits of Use Installation Instructions
Approved for use in HVHZ:No FL16048 R3 II Z015 10 FINAL ER TRI- i
Approved for use outside HVHZ:Yes BUILT UNDERLAYMENTS FL16048-R3.pdf
Impact Resistant:N/A ; Verified By:Robert Nieminen PE-59166
Design Pressure: +N/A/-45 Created by Independent Third Party:Yes
: Other: 1.)The design pressure noted herein pertains to use I Evaluation Reports
1 of foam-on tile systems overtop theself-adhering FL16048 R3 AE 2015 10 FINAL ER TRI- I
underlayment for one particular application.See ER Section BUILT UNDERLAYMENTS FL16048-R3 pit
5.6 for details.2.)Refer to ER Section 5 for other Limits of j Created by Independent Third Party:Yes
Use.
SQDtacLUs::1240 North Monroa.9trctt.n1ahyse a FL 32399 Phone:asp-487-1874
The State of Florida Is an AA/EEO employer.Copvrbht 20p7-;Q13 State of Fbrt1a.::FiVacv statement: IRv 5tatemenr;;g t� IDent
Under Fbrkta law,emal addresses are public records.If you do not want your a-mall address released In response to a public-records request,do not send electronic
mat to this entity.Instead,contact the office by phone or by traditional mall.Q you have any questions,please contact 850.487.1395.'Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department wth an emall address If they have
one.The emats provided may be used forofflcial communication wth the licensee.However emal addresses are public record.If you do not wish to supply a
personal address,please provide the Department wth an emal address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please click here.
Product A 1 Acce
pts-
piss
Wr:rrJ
h-curlrl
2 of 2 5/24/2016 9:58 AM
i
• EXTERIOR RESEARCH&DESIGN,I.I.C.
Certificate of Authorizotion#9503
INI - 353 CHRISTIAN STREET,UNIT#13
RD OXFORD,CT 06478
PHONE:(203)262-9245
FAX:(203)262-9243
EVALUATION REPORT
Allied Building Products Corp. Evaluation Report A42960.10.12-R3
dba TRI-BUILT Roofing Products FL16048-R3
9050 Louisiana Street Date of Issuance:10/25/2012
Merrillville,IN 46410 Revision 3: 10/08/2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance documentation changes,or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete review of this
Evaluation Report_relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5.
Prepared by: Ntrtrterr
Robert l.M.Nieminen► P.E. ;•r:�s ';•""'' Thefacsirnk seat appearing was authoriiedbyRobenN7eminen•
' `, P.E.an 10/0312015.ThIs does not serve as an electronically signed
Florida Registration No.59166,Florida DCA ANE1983 tiocnmem.signed,seated hardcoples have been transmined to the
Product Approval Administratorand to the named went
CERTIFICATION OF INDEPENDENCE:
1. Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity ERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
G
i
TRIM
` ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT,have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4,1507.2.8,1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1,1507.5.3,1507.7.3
1504.6 Accelerated Weathering ASTM G1SS 2005
1507.3.3 Installation Practice FRSA/TRI April 2012(04-12) 2012
1523.6.5.2.1 Physical Properties TA5103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD(TST6049) Physical Properties S40540.02.13-1 02/19/2013
ERD(TST6049) Physical Properties 540540.11.13 11/19/2013
ERD(TST6049) Physical Properties S40540.03.14 03/26/2014
ERD(TST6049) Physical Properties S44870.04.14-2 04/02/2014
ERD(TST6049) Physical Properties S44870.04.14-3 04/02/2014
ERD(TST6049) Physical Properties 544870.04.14-1 04/10/2014
ERD(TST6049) Physical Properties S44870.04.14-4 04/10/2014
ERD(TST6049) Physical Properties 543530.02.14-1-RS 05/14/2014
ERD(TST6049) Physical Properties S43530.05.14 05/28/2014
ERD(TST6049) Physical Properties S40540.10.14 10/31/2014
ERD(TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD(TST6049) Accelerated.Weathering SC8520.04.15 05/27/2015
UL,LLC.(QUA9625) Quality Control Multiple-Listing R16814 09/04/2015
UL,LLC.(QUA9625) Quality Control Service Confirmation Exp.10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self-Adhering Underlayments:
4.1.1 Tri-Built Sand-R SA Shingle Underlayment is a self-adhering, glass-mat reinforced, sand-surfaced, SBS
modified bitumen roof underlayment,with a 36-inch sheet width.
4.1.2 Tri-Built S/A HT TU Underlayment is a self-adhering, non-woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri-Built Smooth HT S/A Underlayment is a self-adhering,glass-mat reinforced,film-surfaced,SBS modified
bitumen roof underlayment.
S. LIMITATIONS:
5.1 'This is a building code evaluation. Neither Trinity)ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
i
I
Exterior Research and Design,L.I.C. Evaluation Report A42960.10.12-R3
Certificate of Authorization#9503 FL16948-113
Revision 3:10/09/2015
Page 2 of 5
i
II ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed,a request may be made to the AH1 for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlayments are as follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment Asphalt Nall-On Tile Foam-On Tile Metal Wood Shakes Slate
Shingles &Shingles
Tri-Built Sand-R SA Shingle Yes No No No Yes Yes
Underlayment
Tri-Built S/A HT TU Yes
Underlayment Yes Yes See 5.5.1 Yes Yes Yes
Tri-Built Smooth HT S/A Yes No No Yes Yes Yes
Underlayment
5.5.1 "Foam-On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion/ long
term aging data from an accredited testing laboratory is provided.
r Tri-Built S/A HT TU Underlayment with 3M1 2-Component Roof Tile Adhesive AH-160(FL6332)or Dow
TileBondl Roof Tile Adhesive(FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct-Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
i- Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; ASTM D41 primed structural
concrete.
While not required over plywood,OSB or Southern Yellow Pine substrates,TRI-BUILT recommends priming
the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT requires
tongue-and-groove board decking be covered with plywood or OSB prior to installation of the self-
adhering underlayment.
5.6.2 Bond-to-Insulation:
Tri-Built S/A HT TU Underlayment applied to:
> Dens Deck Prime;SECU ROCK Gypsum-Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam-on the systems,insulation attachment shall be designed by a qualified design professional and
installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D
or TAS 114,Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
r ASTM D226,Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam-on tile systems,base layer shall be attached
per minimum requirements of FRSA/TRl April 203.2(04-12).
Exterior Research and Design,LLQ Evaluation Report A42960.10.12-R3
Certificate of Authorization#9503 FL1604&R3
Revision 3:10/08/2015
Page 3 of 5
5.6.4 Wind Resistance for Underlayment Systems in Foam-On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam-on the systems,where
the underlayment forms part of the load-path. The following wind uplift limitations apply to direct-deck
underlayment systems that are not addressed in FRSA/TRI April 2012(04-12)and are used in foam-on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure=-45.0 psf.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHI.
Primer: (Optional)ASTM 041
Underlayment: Tri-Built S/A HT TU Underlayment,self-adhered.
5.7 Exposure Limitations:
5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation.
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels,and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Tri Built Sand R SA Shingle Underlayment,Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non-Tile applications:
While priming is optional,TRI-BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as passible.
Once the entire length of membrane is in place, peel-off the release film diagonally while holding the
membrane tight. Firmly roll the membrane into place to-achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below. All over-granule end-laps
shall be sealed using either heat-welding or hot air welding techniques.
When installing at slopes above 8:12, Allied Building Products Corp recommends back-nailing in the
overlap area at the top of the sheet at 12-inch o.c.
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths.Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys,apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications(Tri-Built S/A HTTU Underlayment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
i
Exterior Research and Design,
Evaluation Report A42960.10.12-R3
I.I.C. ,
Cen[ficate of Author&atioa#9503 FU6048-R3
Revision 3:10/08/2015
Page 4 of 5
TRINITYERD
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
B. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C.Rule 9N-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL,LLC_QUA9625;(314)578-3406;k.chancellor@us.ul.com
-END OF EVALUATION REPORT-
Exterior Research and Design,U.C. Evaluation Report A42960.10.12•113
F416048-R3
Certificate of Authorization#9503 j
Revision 3:10/08/2025
Page 5 of 5