HomeMy WebLinkAboutProduct Approval (2) • [ � I- 'f7tq p- 43 J� h�.r+Crai%rJA"��T�fi-t 4: `�'' f���'yL`Ye � � J"
jrd3 3 v'f:r? +Y•f 4# _ 4yC rf `xa.4
:yvr Jr�'.5 ''� .r`i`r.'�`�yeY •x s.t.�`y� •�F��Ttri� r� `" � l'' t ;�r I z �+�
•S.-p , + t � A S 1 9 t`�1 t I j-� 4 w P 7F
,,eg" 7 � t .n s i rt; y,t,,t,� �� �..�g�j i ,'� �tr• I�. .�i..'_.t'Iv"'e �:., .fin
a�17����t �.. �'� �+:k!��'§�r�,�,'4.kYaA� .S rfd �'� 3x�cXcr�,r�ar�"s. � �ryVri' •1�t�T� ���>.
`a'S°2� ., ,.:ty,-F. �yv.r._.:rxz...��.,.�c�a.,_....a,.x".r�:wr..,% fiLn`9• �.c.1S�,.�.-'�a� �r:,: �•y,. .fi"sn:.,�Ex�...;+.
SCIS Home 1.09]n i User Registration # Ho[Topics $UDmlt Surcharge j Stats&Facts } Publications { FBC Staff i BCIS Site Map links Search
;ry `>IIBM Product Approval
USER:Public User
i CF-
•, ri5luytApproval Mrnu>Product or AoollraUon 5earch>Akd&Winn j is,>Application Detail �f a� i
FL17443 EEB 2 L 201
t s, g y tr y FI- #
y 7 w•k 33 Application Type New PERMITTING
Code Version 2014 St. Lucie County, FL
Application Status Approved
Comments
Archived
a
Product Manufacturer J A TAYLOR ROOFING
Address/Phone/Email 302 Melton Drive
FT PIERCE, FL 34982
(772)466-4040
kylewhite228@aol.com
Authorized Signature Kyle Taylor
kylewhite228@aol.com
Technical Representative
'I Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
1, Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Locke Bowden
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/11/2021
Validated By Hermes F. Norero, P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL17443 RO COI Certificat2 of Indenend Locke Bowden P.E..ndf
Referenced Standard and Year(of Standard) Standard Year
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method I Option D
Date Submitted 03/02/2015
Date Validated 03/021201S
Date Pending FBC Approval
03/05/201S
Date Approved 04/15/2015
.Summary pf Products
FL# Made[,Number or Name Description
17443.1 5 V Crimp 26GA 1/2" rib height over 15/32" plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No ELI7443 RO if 5-V Crimp Fastening y tail.pd!
-og
Approved for use outside HVHZ:Yes Verified By: PRI Construction Materials Technologies, LLC
Impact Resistant: N/A Created by Inde
pendent Third Party: Yes
Design Pressure: +N/A/-129.25 Evaluation Reports
Other.-129.2S @ 6"o.c. -69.25 @)16" o.c. margin of safety EL17443 RO AE FL 17443 1. A.Taylor Roofing 5 y_QLLrjip
2:1 with 24"max, coverage Install per manufacturers detail. &p_Q_qj55.p f
Not for use in HVHZ. Created by Independent Third Party: Yes
Contact if ::7641 Illair Stone goad..Tallahassee Ft,37399 Phone:650-487-1824
The State of Florida IS an WEED employer.Cogkricht 2007_2013 State of Florida. -:Edyo2L51atg�n ;:Arcessibltjty Stat erneM::ftfUng Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,tin not Send electronic
mail to this entity.Instead,contact the office by Phone or by traditional mail.If You have any questions,Please contact 850.467.139S.*Pursuant to section
455.275(1),Florida statutes,ettective October 1,2012,licensees licensed under Chapter 455,F.S.Must Provide the Department with an email address if they have
one.The emalls provided may be used(or official communication with the licensee.However email addresses are public record.If you do not wish to Supply a
personal address,Please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter
455,F.S.,please dick here.
Product Approval Accepts:
I W=Fq
Credit Card
Safe
r, pu
Locke Bowden, PX.
9450 Alysbury Place
Montgomery,AL 36117 FL A 17443
JATaylor Roofing Inc
302 Melton Drive
Fort Pierce, FL 34982
Product:
5 V Crimp thru Fastened 1/2" rib at each panel edge and one in the center of the panel,24" net coverage,
26GA min. over min.15/32"thick CDX plywood decks.
Compliance: Florida Building Code (FBC)2014; Section 1504.3.2, Section 1507.2.8, Section 1507.4.3
UL580 "Tests for Uplift Resistance"
Description: Architectural metal roof panel,26 gauge metal panels;over min. 15/32"CDX plywood
and shall comply with Florida Building Code 2014, Section 1507.4.3
Installation: Install per manufacturers install details in accordance with FBC 2014, Section 1507.4.2
Deck Slope 2:12 or greater and shall be compliant with Florida Building Code 2014, Section 1507.4.2.
Design Pressure: -129.25psf @ Vo.c. and-69.25psf @16"o.c.; Fasten along the crown of the rib in the
center of panel and along the lap. Design pressure includes safety factor=2.0. First fastener to be within 3"
of panel edges. Min. 8d x 2"annular ring shank nails spaced 6" o.c. reroofing,with less than 19/32" plywood
9min. 15/32"), this attachment is to be used in addition to existing attachment.Deck,attachment to be by
other design professional.
Underlayment: approved product in compliance with FBC 2014, Section 1507.2.8
Thru-fastened over min.15/32" plywood
Fasteners: #9-15 F1WFI corrosion resistant fasteners with scaling washers, metal to wood connections with
fastener length to penetrate 5/16"through substrate per Florida Building Code 2014, Section 1507.4.4
Conditions of Use: Not for use in HV14Z. Install per manufacturer's instructions and must be designed
In compliance with Florida Building Code 2014. Manufacturer is compliant with Rule 61 G20-3; wherein
manufacturer complies under a quality assurance program audited by approved
Quality Assurance Entity; Keystone Certifications valid thru 4/11/202.1
Evidence Submitted:
a. UL 580/TAS 125 Tests for Uplift Resistance
b. Reference-Test Report 0224-0501-06 Hurricane Test Laboratory AlItIlilryllf,
C. Test equivalency standard—the U L 5 80-94 test standard is cquixiEZ 4; 0 0-06
d. Quality Assurance Procedures and Documentation
No. 4970
�
2
FL,
This wpoit does no(guarantee or warranty any product validated or installed.Mmuructurer's warranty applies.
• 5 V Crimp
4
Fastener-49-15 corrosion resistant w/sealing washers 'j 24" coverage
Fastener: #9 x 15 corrosion resistant with sealing washers
in Compliance with 2014 Florida Building Code, Section 1507.4.4
Perimeter fastening: 6"o.c.
Main Field fastening12"o.c.
Panel Width: 26"
Panel Coverage: 24"maximum
26 GA Architectural Metal Roof panel
� � ��������0 �
� ^! n `� �« � » �\ \
,§ [ ( % , )��
� � [ (e / � ( \� ,
� , � ��� ] \��}� {
\
}
\ .
?� i