Loading...
HomeMy WebLinkAboutWind Load Calculation File Copy Planning&Development Services Department Building&Code Regulations Division — - :"=---3 2300 Virginia Avenue, Fort Pierce,FL 34982—(772)462-1553 Certification or Design Load Compliance Project Name: Project Address: Permit#: / Occupancy Type:JA_Construction Type: S _ INSTRUCTIONS FOR USE: e This certification must be completed,signed,and sealed by the design professional of record. O Submit 12)copies for residential,(3)copies for commercial with all permit applications involving the following: o New Residences(single or multi-family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Farm not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official.Contact the#above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2014 Building Code Fifth Edition with 20 NIA Supplements using ASCE 7-10 2. Structure Designed as(check one): X Enclosed Partially Enclosed Open 3. Risk Category: _I X 11 111 IV Exposure Category: B X C D 4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft 5. Mean Roof Height t! ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components&&Cladding Design Pressures Used:(PSF based on 10sgft @ 15'MRH,clearly label on all plan openings): ti``Z..LSc L• -i 7 i� ITGL�r(.9 4 3 Li j' `�`.�K r t" 1`Z�/g Zone 1, ­3t.I Zone 2:. ��,3 Zone 3: - ,1, Zone 4: - Ti -j& Zone S:-Yk-• Garage: '73:F,y- 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF Dock: N/A PSF Deck: NSA PSF Stairs: N/A PSF Fence: NSA PSF Railings: NSA PSF _ • r 8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County.:',I alsp,certifNtbat structural elements depicted on these plans provide adequate resistance to the design forces spe f&ed--: n/ 1—il 70 /f Print Name Cert#&Co.Cert Auth. e,Date and S .l `,ry- f� -!'= 3r �� Company Name&Address Revised 07 ZS%20`4 _