Certification or Design Load Compliance
Project Name:
Project Address:
Permit#: / Occupancy Type:JA_Construction Type: S
_ INSTRUCTIONS FOR USE:
e This certification must be completed,signed,and sealed by the design professional of record.
O Submit 12)copies for residential,(3)copies for commercial with all permit applications involving the following:
o New Residences(single or multi-family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Farm not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official.Contact the#above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2014 Building Code Fifth Edition with 20 NIA Supplements using ASCE 7-10
2. Structure Designed as(check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X 11 111 IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height t! ft Roof Pitch: 6 :12 Parapet: NSA ft
6. Components&&Cladding Design Pressures Used:(PSF based on 10sgft @ 15'MRH,clearly label on all plan openings):
ti``Z..LSc L• -i 7 i� ITGL�r(.9 4 3 Li j' `�`.�K r t" 1`Z�/g
Zone 1, 3t.I Zone 2:. ��,3 Zone 3: - ,1, Zone 4: - Ti -j& Zone S:-Yk-• Garage: '73:F,y-
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF
Dock: N/A PSF Deck: NSA PSF Stairs: N/A PSF Fence: NSA PSF Railings: NSA PSF
_ • r
8. Were Shear Walls Considered For Structure? Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that,to the best of my knowledge and belief,the attached plans&specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County.:',I alsp,certifNtbat structural elements depicted on these plans provide adequate resistance to the design
forces spe f&ed--: n/ 1—il 70 /f
Print Name Cert#&Co.Cert Auth.
e,Date and S .l `,ry- f� -!'=
3r �� Company Name&Address
Revised 07 ZS%20`4 _