Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Calculation Form & Manual J's
File Copy Building Analysis Job: Sawgrass Lot 283 9 Y Date: 2-2-17 Entire House By: Skyetec . ;Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design C• • • 4-ocation• Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (7) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb(T) 43 90 Infiltration: Daily range °F) - 16 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ft2 Btuh % of load Walls 3.8 9518 20.5 Glazing 13.1 6794 14.6 Doors 10.5 1460 3.1 Ceilings 0.9 2599 5.6 Floors 2.9 8711 18.8 Infiltration 1.5 84466 955 9. Ducts 8955 19.3 Piping 0 0 Humidification 0 0 Ventilation 3935 8.5 Adjustments 0 Total 1464371 100.0 • • • Component Btuh/ft2 Btuh % of load Walls 2.4 6107 14.9 Glazing 16.9 8807 21.5 Doors 11..2 1549 3.8W. Ceilings 1.0 3095 7.6 Floors 0 0 0 Infiltration 0.5 1329 3.2 Ducts 11126 27.2 Ventilation 2186 5.3 Internal gains 6740 16.5 Blower 0 0 . Adjustments 0 Total 1409391 100.0 w! Latent Cooling Load= 14129 Btuh Overall U-value= 0.117 Btuh/ft2-°F Data entries checked. .- + wrightsoft- 2017-Mar-28 16:39:40 Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N BuildingAnalysis Job: Sawgrass Lot 283 Date: 2-2-17 (Rest Of House) By: Skyetec Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions =Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 27 15 Latitude: 28°N Relative humldlty (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb(°F) 43 90 Infiltration: Daily range °F) - 16 ( L ) Method Simplified. Wet bulb(°F - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 ea Component Btuh/ft2 Btuh % of load a Walls 3.8 5033 17.0 w� Glazing 13.1 5258 17.8 Doors 10.5 983 3.3 Ceilings 0.9 1769 6.0 Floors 2.2 4506 15.2 Infiltration 1.5 2431 8.2 Ducts 6658 22.5 Piping 0 0 Humidification 0 0 Ventilation 2973 10.0 Adjustments 0 Po. Total 29611 100.0 Cooling Component Btuh/ft2 Btuh % of load Walls 2.4 3209 11.0 v� Glazing 16.0 6446 22.0 Doors 11.2 1043 3.6 Ceilings 1.0 2106 7.2 Floors 0 0 0 Infiltration 0.5 724 2.5 Ducts 8288 28.3 Ventilation 1652 5.6 Internal gains 5780 19.8 Blower 0 0 Adjustments 0 Total 29247 100.0 � Latent Cooling Load= 9907 Btuh Overall U-value= 0.110 Btuh/ft2-°F Data entries checked. + wrightsoft� 2017-Mar-28 16:39:40 RightSuite®Universal 2017 17.0.04 RS000269 Page 2 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N BuildingAnalysis Job: .Sawgrass Lot 283 Y Date: 2-2-17 Master By: Skyetec Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling -Moisture difference(gr/lb) 22.0 61.5 Dry bulb(°F) 43 90 Infiltration: Daily range(°F) - 16 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heating Component Btuh/ftz Btuh % of load m- Walls 3.9 4485 26.7 Glazing 13.0 1536 9.1 - Doors 10.5 477 2.8 Ceilings 0.9 831 4.9 Floors 4.4 4206 25.0 Infiltration 1.5 2035 12.1 Ducts 2296296 13.6 Piping 0 0 Humidification 0 0 Ventilation 961 5.7 Adjustments 0 Total 16826 100.0 Component Btuh/ft2 Btuh % of load Viqe� - Walls 2.5 2898 23.5 w Glazing 24.2 2845 ,23.0 Doors 11.2 507 4.1 Ceilings 1.0 989 8.0 Floors 0 0 0 Infiltration 0.5 606 4.9 Ducts 3019 24.4 Ventilation 534 4.3 Internal gains 960 7.8 Blower 0 0 Adjustments 0 Total 12358 100.0 �. Latent Cooling Load=4222 Btuh Overall U-value= 0.132 Btuh/ft2-°F Data entries checked. - - wrightsoft' 2017-Mar-2816:39:40 ACCI" RightSuite®Universal 2017 17.0.04 RS000269 Page 3 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Sawgrass Lot 283 Date: 2-2-17 Entire House By: Skyetec Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD (OF) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb(OF) 43 90 Infiltration: Daily range(OF) - 16 ( L ) Method Simplified Wet bulb(OF) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuhtt?°F ft?°FBtuh Btuh/ft' Btu Btuh/ft' Btuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum n 306 0.143 4.0 3.86 1181 2.50 763 board int fnsh a 827 0.143 4.0 3.86 3192 2.50 2063 s 367 0.143 4.0 3.86 1415 2.50 915 sw 35 0.143 4.0 3.86 135 2.50 87 w 738 0.143 4.0 3.86 2849 2.50 1841 all 2272 0.143 4.0 3.86 8772 2.50 5669 Partitions 12B-Osm:Frm wall,stucco ext,r-11 cav ins,1/2"gypsum board int 226 0.122 11.0 3.29 746 1.93 438 fnsh,2"x4"metal frm,16"o.c.stud Windows 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" n 12 0.460 0 12.4 149 12.4 148 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);10 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 12 0.460 0 12.4 152 12.4 151 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);1.5 ft overhang(3.5 ft window ht, 1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ftwindow ht,2 n 24 0.490 0 13.2 318 12.6 302 ft sep.);6.67 ft head ht all 42 0.490 0 13.2 556 12.6 529 2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" a 24 0.460 0 12.4 298 29.5 708 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, s 24 0.460 0 12.4 298 12.4 296 1/4"thk;NFRC rated(SHGC=0.26);1.5 ft overhang(2 ft window ht,1 w 12 0.460 0 12.4 149 29.5 354 ft sep.);6.67 ft head ht all 60 0.460 0 12.4 745 22.6 1358 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" e 3 0.460 0 12.4 37 25.4 76 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);3 ft overhang(3 ft window ht,1.5 w 3 0.460 0 12.4 37 25.4 76 ft sep.);6.67 ft head ht all 6 0.460 0 12.4 75 25.4 153 wri htsoft0 2017-Mar-2816:39:41 TFr9 Right-Suite®Universal 2017 17.0.04 RSU00269 Page 1 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N 2 glazing,cir low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,1/4" e 9 0.490 0 13.2 119 29.8 269 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(3 ft window ht,1 w 6 0.490 0 13.2 79 29.8 179 ft sep.);6.67 ft head ht all 15 0.490 0 13.2 198 29.8 448 2 glazing,cir low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,1/4" a 15 0.490 0 13.2 193 30.5 444 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, a 15 0.490 0 13.2 198 30.5 457 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(5 ft window ht,1 w 30 0.490 0 13.2 397 30.5 914 ft sep.);6.67 ft head ht all 60 0.490 0 13.2 788 30.5 1814 2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 6 0.460 0 12.4 75 12.4 74 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, - 1/4"thk;NFRC rated(SHGC=0.26);5.6 ft overhang(2 ft window ht, sw 6 0.460 0 12.4 72 12.4 72 1.5 ft sep.);6.67 ft head ht all 12 0.460 0 12.4 147 12.4 146 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr, 1/4"gap,1/4" s 24 0.460 0 12.4 298 12.4 296 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);14 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht '2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" s 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,1 s 19 0.490 0 13.2 245 12.6 233 ft sep.);6.67 ft head ht all 37 0.490 0 13.2 483 12.6 460 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" s 72 0.490 0 13.2 953 12.7 918 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);5.6 ft overhang(6 ft window ht,3 sw 19 0.490 0 13.2 245 12.6 233 ft sep.);6.67 ft head ht all 37 0.490 0 13.2 483 12.6 460 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" s 96 0.500 0 13.5 1296 12.7 1223 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);14 ft overhang(8 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" w 6 0.460 0 12.4 75 12.4 74 thk:2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);10 ft overhang(2 ft window ht,1.5 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,1/4" w 12 0.490 0 13.2 159 30.2 363 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(4 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" w 18 0.490 0 13.2 238 14.8 266 thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);10 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht Doors 11DO:Door,wd sc type n 48 0.390 0 10.5 505 11.2 536 e 23 0.390 0 10.5 239 11.2 253 w 45 0.390 0 10.5 477 11.2 507 n 23 0.390 0 10.5 239 11.2 253 all 139 0.390 0 10.5 1460 11.2 1549 Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 cell ins,1/2" 3008 0.032 30.0 0.86 2599 1.03 3095 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile fir 273 1.180 0 31.9 8711 0 0 fnsh •: WCI htsoft' 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 2 ACCK ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Caic=MJ8 Front Door faces: N Component Constructions Job: Sawgrass Lot 283 Date: 2-2-17 Master By: Skyetec Project Inf6rmation GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD (°F) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb (OF) 43 90 Infiltration: Daily range(OF) - 16 ( L ) Method Simplified Wet bulb( F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain fJ2 Btuh/ft?°F ft?°F/Btuh MOM Btu MOM' Btuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum n 173 0.143 4.0 3.86 667 2.50 431 board intfnsh a 301 0.143 4.0 3.86 1162 2.50 751 s 109 0.143 4.0 3.86 419 2.50 271 w 579 0.143 4.0 3.86 2237 2.50 1446 all 1162 0.143 4.0 3.86 4485 2.50 2898 Partitions (none) Windows 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 12 0.460 0 12.4 152 12.4 151 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);1.5 ft overhang(3.5 ft window ht, 1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" n 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,2 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" w 12 0.460 0 12.4 149 29.5 354 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);1.5 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" e 3 0.460 0 12.4 37 25.4 76 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);3 ft overhang(3 ft window ht,1.5 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" w 6 0.490 0 13.2 79 29.8 179 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(3 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" w 30 0.490 0 13.2 397 30.5 914 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(5 ft window ht,1 ft sep.);6.67 ft head ht WCI htsoft® 2017-Mar-2816:39:41 At. 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 3 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N 2 glazing,clr low-e outr,argon gas,vnl firm mat,cir innr,1/4"gap,1/4" s 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,1 s 19 0.490 0 13.2 245 12.6 233 ft sep.);6.67 ft head ht all 37 0.490 0 13.2 483 12.6 460 Doors 11 DO:Door,wd sc type a 23 0.390 0 10.5 239 11.2 253 w 23 0.390 0 10.5 239 11.2 253 all 45 0.390 0 10.5 477 11.2 507 Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 ceiI ins,1/2" 961 0.032 30.0 0.86 831 1.03 989 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile fir 132 1.180 0 31.9 4206 0 0 'fnsh wlri htsoft® 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 4 ACCA ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Component Constructions Job: Sawgrass Lot 283 Date: 2-2-17 (Rest of House) By: Skyetec Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Design Conditions Location: Indoor: Heating Cooling Vero Beach, FL, US Indoor temperature(T) 70 75 Elevation: 26 ft Design TD (T) 27 15 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 22.0 61.5 Dry bulb(T) 43 90 Infiltration: Daily range(T) - 16 ( L ) Method Simplified Wet bulb(T) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/F-T ft?°F/Btuh Btuh/ft' Btuh MAW Btuh Walls 13A-4ocs:Blk wall,stucco ext,r-4 ext bd ins,8"thk,1/2"gypsum n 133 0.143 4.0 3.86 514 2.50 332 board intfnsh a 526 0.143 4.0 3.86 2030 2.50 1312 s 258 0.143 4.0 3.86 996 2.50 644 sw 35 0.143 4.0 3.86 135 2.50 87 w 158 0.143 4.0 3.86 612 2.50 395 all 1110 0.143 4.0 3.86 4287 2.50 2771 Partitions 12B-Osm:Frm wall,stucco ext,r-11 cav ins,1/2"gypsum board int 226 0.122 11.0 3.29 746 1.93 438 fnsh,2"x4"metal frm,16"o.c.stud Windows 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 12 0.460 0 12.4 149 12.4 148 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);10 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" n 24 0.490 0 13.2 318 12.6 302 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,2 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" a 24 0.460 0 12.4 298, 29.5 708 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);1.5 ft overhang(2 ft window ht,1 s 24 0.460 0 12.4 298 12.4 296 ft sep.);6.67 ft head ht all 48 0.460 0 12.4 596 20.9 1004 2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap,1/4" w 3 0.460 0 12.4 37 25.4 76 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);3 ft overhang(3 ft window ht,1.5 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" e 9 0.490 0 13.2 119 29.8 269 thk:2 glazing,Or low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(3 ft window ht,1 ft sep.);6.67 ft head ht t wri htsoftm 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 5 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N 2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" a 15 0.490 0 13.2 193 30.5 444 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(5 ft window ht,1 e 15 0.490 0 13.2 198 30.5 457 ft sep.);6.67 ft head ht all 30 0.490 0 13.2 391 30.5 901 2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 6 0.460 0 12.4 75 12.4 74 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);5.6 ft overhang(2 ft window ht, sw 6 0.460 0 12.4 72 12.4 72 1.5 ft sep.),6.67 ft head ht all 12 0.460 0 12.4 147 12.4 146 2 glazing,cir low-e outr,argon gas,vni frm mat,clr innr,1/4"gap,1/4" s 24 0.460 0 12.4 298 12.4 296 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);14 ft overhang(2 ft window ht,1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 72 0.490 0 13.2 953 12.7 918 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht 2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 18 0.490 0 13.2 238 12.6 227 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);5.6 ft overhang(6 ft window ht,3 sw 19 0.490 0 13.2 245 12.6 233 ft sep.);6.67 ft head ht all 37 0.490 0 13.2 483 12.6 460 2 glazing,clr low-e outr,argon gas,vni frm mat,cir innr,1/4"gap,1/4" s 96 0.500 0 13.5 1296 12.7 1223 thk:2 glazing,cir low-e outr,argon gas,vnl frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);14 ft overhang(8 ft window ht,1 ft _ sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" w 6 0.460 0 12.4 75 12.4 74 thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.26);10 ft overhang(2 ft window ht,1.5 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap,1/4" w 12 0.490 0 13.2 159 30.2 363 thk:2 glazing,clr low-e outr,argon gas,vnl frm mat,clr innr,1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);1.5 ft overhang(4 ft window ht, 1 ft sep.);6.67 ft head ht 2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr, 1/4"gap,1/4" w 18 0.490 0 13.2 238 14.8 266 thk:2 glazing,cir low-e outr,argon gas,vni frm mat,cir innr, 1/4"gap, 1/4"thk;NFRC rated(SHGC=0.25);10 ft overhang(6 ft window ht,3 ft sep.);6.67 ft head ht Doors 11 DO:Door,wd sc type n 48 0.390 0 10.5 505 11.2 536 w 23 0.390 0 10.5 239 11.2 253 n 23 0.390 0 10.5 239 11.2 253 all 93 0.390 0 10.5 983 11.2 1043 Ceilings 16D-30td:Attic ceiling,tile,slate,concrete roof mat,r-30 ceil ins,1/2" 2047 0.032 30.0 0.86 1769 1.03 2106 gypsum board int fnsh Floors 22A-tpm:Bg floor,heavy dry or light damp soil,on grade depth,tile'flr 141 1.180 0 31.9 4506 0 0 fnsh WI'1 htsoft® 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 6 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Project Summary Job: Sawgrass Lot 283 1 Date: 2-2-17 Entire House By: Skyetec Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Notes: Design I nformation Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 37483 Btuh Structure 29813 Btuh Ducts 8955 Btuh Ducts 11126 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 46437 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 38892 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 10508 Btuh Ducts 3621 Btuh Heating coolingg Central vent (0 cfm) 0 Btuh Area(ftz) 3008 3008 Equipment latent load 14129 Btuh Volume(ft3) 32253 32253 Air changes/hour 0.28 0.15 Equipment total load 53020 Btuh - Equiv.AVF(cfm) 151 81 Req. total capacity at 0.80 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 OF Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl9 htsoft® 2017-Mar-2816:39:41 ACC Right-Suite®Universal 2017 17.0.04 RSU00269 Page 1 ...d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Pry ect SUn1171a Job: Sawgrass Lot 283 J ry Date: 2-2-17 (Rest of House) By: Skyetec -Project Information For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Notes: Design Information Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22953 Btuh Structure 20959 Btuh Ducts 6658 Btuh Ducts 8288 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 29611 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 27784 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 7220 Btuh Ducts 2687 Btuh Heatingg Coolingg Central vent (0 cfm) 0 Btuh Area(ft2 2047 2047 Equipment latent load 9907 Btuh Volume(ft') 22581 22581 Air changes/hour 0.22 0.12 Equipment total load 37691 Btuh Equiv.AVF(cfm) 82 44 Req. total capacity at 0.80 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM; RUUD Model Cond RA1642AJ1 AHRI ref Coil RH1T4821STAN AHRI ref 7942888 Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER Heating input 0 Btuh Sensible cooling 33200 Btuh Heating output 0 Btuh Latent cooling 8300 Btuh Temperature rise 0 OF Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C WI.1 htsoft- 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 2 ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Project Summary Job: Sawgrass Lot 283 1 Date: 2-2-17 Master By: Skyetec :;Project Inlormation, For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Notes: -Diesign Inf6rmation, Weather: Vero Beach, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14530 Btuh Structure 9339 Btuh Ducts 2296 Btuh Ducts 3019 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16826 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 11740 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3288 Btuh Ducts 934 Btuh Heating Cooling Central vent 0 cfm) 0 Btuh Area(ft2) 961 961 Equipment latent load 4222 Btuh Volume(ft3) 9671 9671 Air changes/hour 0.43 0.23 Equipment total load 15962 Btuh Equiv.AVF(cfm) 69 37 Req. total capacity at 0.80 SHR 1.2 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM Model Cond RA1618 AHRI ref Coil RH1T2417 AHRI ref 7940565 Efficiency 80AFUE Efficiency 13.0 EER, 16 SEER Heating input 0 Btuh Sensible cooling 15280 Btuh Heating output 0 Btuh Latent cooling 3820 Btuh Temperature rise 0 OF Total cooling 19100 Btuh Actual air flow 637 cfm Actual air flow 637 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.052 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsoftm 2017-Mar-2816:39:41 Right-Suite®Universal 2017 17.0.04 RS000269 Page 3 ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Sawgrass Lot 91 N ;m Family-Room 174 cfm 174 cfm'. ..12 x 12 Nook 12x 12 .. 10 x 10 9 2.0 ft • T/141 cfm- - •. 9'.10.7 Master BR 12 x 12 y 327 cfm 10x10 i g T 5 m Living f2oom 10',5. ft 185'cf Kitchen ;,6x6 4",4.6 tox.10 • •12x12. 35,cfm 6x6 123 fm 14.2 ft 144 cfm • 14°,26.3I1 9'„12 6 ft , His T.: BR 2 1.5 Ton Hers 10x10 7 24x18 - 6 x 6 68 cfm 7",9.2 ft Hall, `12•x 12 - 15�fnn 12x12 16•, 1ft -10 8.0 It' y. - - ",14.7ft 6 x 6 _ 30 x y 8;x 8 8',8.5ft 12 36 cfm �- 67 cfm y 12 6.6 ft O 4 ,9.5 ft.. / PoOwde 4",11.4 ft 71,6.6 ft 59 cfm 6',10.1 ft JJ Foer ,' 6 x 6 Bath 2 - - T. Dining Y Den 22 cfm 10 cfm 1 ,8.5 ft O 4."„4.2 ft 12,",12.5 ft. 4',2.1 f1 ` ^12x12' WC :.10",5.7ft 8",7.9ft• 4°,8.5ft 7 6:6 ft 18',13.0. .. 33 c f 6x6 m BR3 f 7 ,7.2ft. lox10r 159 cfm -111 x.10 _10x.10�" '139 cfm 109 cfm UtHity M Bath -- O Schedule F Exhaust Fan ORange Vent ODryer Vent Rheem Equipment AHU 3.5 Ton 16SEERRH1T48 Garage Cond 3.5 Ton 16 SEER RA1642AJ 3.5 Tcn AHU 1.6 Tcn 16 S EER RH1 T24 Cond 1.5 Ton 16 SEER RA161 Mj Job#: Sawgrass Lot 283 Scale: 1 : 130 Performed by Skyetec for: Page 1 GHO Homes Right-Suite®Universal 2017 3400 Bent Pine Dr 17.0.04 RS000269 Fort Pierce,FL 34951 2017-Mar-28 16:39:43 ..Skytec\Sawgrass Lot 283 GL N.rup r i Duct System Summary Job: Sawgrass Lot 283 Date: 2-2-17 (Rest of House) By: Skyetec Project For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.18 in H2O Available static pressure 0.32 in H2O 0.32 in H2O Supply/return available pressure 0.220/0.100 in H2O 0.220/0.100 in H2O Lowest friction rate 0.128 in/100ft 0.128 in/100ft Actual air flow 1383 cfm 1383 cfm Total effective length(TEL) 250 ft SuplSly Brarich .DetailTable Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Mat[ Ln (ft) Ln (ft) Trunk BR 2 c 2602 112 123 0.135 7.0 Ox 0 VIFx 22.7 140.0 st5 BR 3 c 2931 131 139 0.142 7.0 Ox0 VIFx 15.2 140.0 st5 Bath 2 h 1026 48 36 0.139 4.0 Ox 0 VIFx 18.0 140.0 st5 Dining h 2603 122 68 0.151 7.0 Ox0 VIFx 15.7 130.0 st4 Family Room h 4186 196 174 0.128 9.0 Ox0 VIFx 37.0 135.0 st3 Family Room-A h 4186 196 174 0.135 9.0 Ox0 VIFx 28.8 135.0 st3 Foyer h 1967 92 67 0.148 6.0 Ox0 VIFx 19.1 130.0 st4 JJ h 310 14 10 0.144 4.0 Ox0 VIFx 12.7 140.0 st5 Kitchen c 3904 34 185 0.131 8.0 Ox0 VIFx 33.2 135.0 st3 Living Room h 4240 198 144 0.138 9.0 Ox0 VIFx 25.1 135.0 st4 Nook c 2978 139 141 0.129 8.0 Ox0 VIFx 36.1 135.0 st3 Powder h 457 21 15 0.139 4.0 Ox 0 VIFx 23.9 135.0 st4 Utility c 2309 80 109 0.141 7.0 Ox 0 VIFx 15.7 140.0 st5 • • Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 Peak AVF 564 673 0.128 630 14.0 0 x 0 VinlFlx st4 Peak AVF 433 294 0.138 551 12.0 0 x 0 VinlFlx sty Peak AVF 387 417 0.135 531 12.0 0 x 0 VinlFlx Bold/italic values have been manually overridden wri htsoft® 2017-Mar-2816:39:41 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 1 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N w TableReturn Branch Detail Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb2 Ox0 1383 1383 78.0 0.128 634 20.0 Ox 0 VIFx rst2 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst2 Peak AVF 1383 1383 0.128 783 1&0 0 x 0 VinlFlx Bold/italic values have been manually overridden wri htsoft® 2017-Mar-28 16:39:41 At. 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 2 d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N Duct System Summary Job: Sawgrass Lot 283 Date: 2-2-17 Master By: Skyetec Project Inf• • For: GHO Homes 3400 Bent Pine Dr, Fort Pierce, FL 34951 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0.18 in H2O 0.18 in H2O Available static pressure 0.32 in H2O 0.32 in H2O Supply/return available pressure 0.219/0.101 in H2O 0.219/0.101 in H2O Lowest friction rate 0.146 in/100ft 0.146 in/100ft Actual air flow 637 cfm 637 cfm Total effective length (TEL) 219 ft SupplyDetail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln (ft) Ln (ft) Trunk c 421 21 22 0.158 4.0 Ox 0 VIFx 8.7 130.0 st1 Den h 1885 71 59 0.149 6.0 0x 0 VIFX 16.7 130.0 st1 Hers h 1521 58 35 0.147 4.0 OXO VIFX 19.3 130.0 st2 His c 47 1 2 0.148 4.0 Ox 0 VIFx 17.9 130.0 st2 M Bath h 5313 201 159 0.152 8.0 Ox0 VIFX 14.5 130.0 st1 Master BRA C 6350 255 327 0.146 10.0 OX 0 VIFX 20.2 130.0 st2 we c 643 30 33 0.151 4.0 Ox0 VIFx 15.1 130.0 st1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 Peak AVF 323 273 0.149 411 12.0 0 x 0 VinlFlx st2 Peak AVF 314 364 0.146 464 12.0 0 x 0 VinlFlx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb3 OX 0 637 637 69.1 0.146 456 16.0 Ox 0 VIFx Bold/italic values have been manually overridden 1 WI'1 I7tSOft® 2017-Mar-2816:39:41 A:. 9 Right-Suite®Universal 2017 17.0.04 RS000269 Page 3 ..d Calculations\Skytec\Sawgrass Lot 283 GL N.rup Calc=MJ8 Front Door faces: N