HomeMy WebLinkAboutEnergy Calculation Form & Manual J's (2) File Copy
W
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: SAWGRASS_eCLASSIC_MDW 283 Builder Name: GHO HOMES
Street: 3400 BENT PINE DR. Permit Office:
City,State,Zip: FT P1-e/6C , FL,34951 Permit Number:
Owner: GHO HOMES Jurisdiction:
Design Location: FL,VERO_BEACH_MUNICIPAL ARPT County:: INdian River(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3069.5 sqft.) Insulation Area
2. angle family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2809.50 ftz
b.Frame-Steel,Adjacent R=11.0 260.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types (3085.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 3085.00 ftz
6. Conditioned floor area above grade(ftz) 3085 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(517.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH: 1 st Floor A 6 318.9
a. U-Factor: Dbl,U=0.49 277.00 ftz b.Sup: Attic,Ret:Attic,AH: 1st Floor B 6 318.9
SHGC: SHGC=0.24
b. U-Factor: Dbl,U=0.46 133.82 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.26 a.Central Unit 42.0 SEER:16.00
b.Central Unit 18.0 SEER:16.00
c. U-Factor: Dbl,U=0.50 96.00 ftz
SHGC: SHGC=0.25 13. Heating systems kBtu/hr Efficiency
d. U-Factor: other(see details) 10.29 ftz a.Electric Strip Heat 42.0 COP:1.00
SHGC: other(see details) b.Electric Strip Heat 18.0 COP:1.00
Area Weighted Average Overhang Depth: 5.990 ft.
Area Weighted Average SHGC: 0.246 14.Hot water systems
8. Floor Types (3085.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 3085.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.168 Total Proposed Modified Loads: 98.27 PASS
Total Baseline Loads: 98.26
I hereby certify that the plans and specifications covered by Review of the plans and 01
o-vRE STA
this calculation are in compliance with the Florida Energy specifications covered by thisp�,
Code. calculation indicates compliance ��+`�,, �'' yf6
t'O�
with the Florida Energy Code. � mu,.;• ;-•, •:r :.•a;,,:y,�
PREPARED BY: �7 Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 * .
I hereby certify that t:T1. , signed, is in compliance Florida Statutes.with the Florida Ene� COp WE
OWNER/AGENT: BUILDING OFFICIAL:
DATE: 3 4.31 DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house.
3/29/2017 4:17 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
i
FORM R405-2014
PROJECT
Title: SAWGRASS_eCLASSIC_MD Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 3085 Lot#
Owner: GHO HOMES Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: GHO HOMES Rotate Angle: 180 Street: 3400 BENT PINE DR.
Permit Office: Cross Ventilation: County: INdian River
Jurisdiction: Whole House Fan: City,State,Zip: VERO BEACH,
Family Type: Single-family FL, 34951
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,VERO_BEACH_MUN FL_VERO_BEACH_MUNI 2 45 90 70 75 299 64 Medium
BLOCKS
Number Name Area Volume
1 Blockl 2060 20600
2 Block2 1025 10250
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor A 2060 20600 Yes 2 2 1 Yes Yes Yes
2 1st Floor B 1025 10250 No 2 1 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 187.61 ft 0 2060 ft2 ---- 1 0 0
2Slab-On-Grade Edge Insulatio 1st Floor B 132.83 ft 0 1025 ft2 ---- 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
J # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Flat tile/slate 3342 ft2 0 ft2 Medium 0.75 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 150 3085 ft2 N N
3/29/2017 4:17 PM EnergyGauge@)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 1 st Floor A 30 Blown 2060 ft2 0.11 Wood
2 Under Attic(Vented) 1 st Floor B 30 Blown 1025 ft2 0.11 Wood
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below
# Ornt To Wall Type SpaceR_Vaue Et n Ft In Area RA1,111ye FraCtinn Ahsor
1 S=>N Garage Frame-Steel 1 st Floor A 11 22 10 220.0 ft2 0.23 0.01 0
2 W=>E Garage Frame-Steel 1 st Floor A 11 2 10 20.0 ft2 0.23 0.01 0
3 E=>W Garage Frame-Steel 1 st Floor A 11 2 10 20.0 ft2 0.23 0.01 0
4 E=>W Exterior Concrete Block-Int Insullst FloorA 4.1 7 8 10 76.7 ft2 0 0 0.600000 0
5 S=>N Exterior Concrete Block-Int Insullst FloorA 4.1 10 10 10 108.3 ft2 0 0 0.600000 0
6 E=>W Exterior Concrete Block-Int Insullst FloorA 4.1 3 4 10 33.3 ft2 0 0 0.600000 0
7 S=>N Exterior Concrete Block-Int Insutl st Floor A 4.1 6 4 14 88.7 ft2 0 0 0.600000 0
8 W=>E Exterior Concrete Block-Int Insutlst Floor B 4.1 4 0 10 40.0 ft2 0 0 0.600000 0
9 S=>N Exterior Concrete Block-Int Insullst Floor B 4.1 7 10 10 78.3 ft2 0 0 0.600000 0
10 W=>E Exterior Concrete Block-Int Insullst Floor B 4.1 16 1 10 160.8 ft2 0 0 0.600000 0
11 S=>N Exterior Concrete Block-Int Insult st Floor B 4.1 13 0 10 130.0 ft2 0 0 0.600000 0
12 E=>W Exterior Concrete Block-Int Insutl st Floor B 4.1 65 10 10 658.3 ft2 0 0 0.600000 0
13 N=>S Exterior Concrete Block-Int Insull st Floor B 4.1 15 4 10 153.3 ft2 0 0 0.600000 0
14 W=>E Exterior Concrete Block-Int Insutlst Floor B 4.1 13 0 10 130.0 ft2 0 0 0.600000 0
15 N=>S Exterior Concrete Block-Int Insullst Floor A 4.1 15 10 10 158.3 ft2 0 0 0.600000 0
16 E=>W Exterior Concrete Block-Int Insutlst FloorA 4.1 5 1 10 50.8 ft2 0 0 0.600000 0
17 NE=>SW Exterior Concrete Block-Int Insutl st Floor A 4.1 4 6 10 45.0 ft2 0 0 0.600000 0
18 N=>S Exterior Concrete Block-Int Insullst FloorA 4.1 4 2 10 41.7 ft2 0 0 0.600000 0
19 E=>W Exterior Concrete Block-Int Insullst FloorA 4.1 4 9 10 47.5 ft2 0 0 0.600000 0
20 N=>S Exterior Concrete Block-Int Insutl st Floor A 4.1 21 6 10 215.0 ft2 0 0 0.600000 0
21 W=>E Exterior Concrete Block-Int Insullst FloorA 4.1 59 4 10 593.3 ft2 0 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 S=>N Wood 1 st Floor A None .14 2 8 8 21.3 ft2
2 S=>N Insulated 1st FloorA None .14 3 8 24 ft2
3 S=>N Insulated 1 st Floor A None .14 3 8 24 ft2
4 E=>W Insulated 1st Floor A None .14 1 4 8 10.7ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 E=>W 4 Metal Low-E Double Yes 0.49 0.24 12.0 ft2 1 ft 0 in 2 ft 8 in Drapes/blinds None
2 S=>N 5 Metal Low-E Double Yes 0.49 0.24 24.0 ft2 .1 ft 0 in 2 ft 8 in Drapes/blinds None
3 S=>N 7 Metal Low-E Double Yes 0.46 0.26 22.0 ft2 10 ft 0 in 3 ft 6 in Drapes/blinds None
4 S=>N 9 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 1 ft 0 in 2 ft 8 in Drapes/blinds None
5 W=>E 10 Metal Low-E Double Yes 0.49 0.24 8.0 ft2 1 ft 0 in 1 ft 9 in Drapes/blinds None
3/29/2017 4:17 PM EnergyGaugeg)USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered orientation => changed to As Built(rotated 180 degrees).
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
6 S=>N 11 Metal Low-E Double Yes 0.46 0.26 21.8 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
7 E=>W 12 Metal Low-E Double Yes 0.49 0.24 8.0 ft' 1 ft 0 in 1 ft 3 in Drapes/blinds None
8 E=>W 12 Metal Low-E Double Yes 0.49 0.24 6.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
9 N=>S 13 Metal Low-E Double Yes 0.49 0.24 36.0 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds None
10 N=>S 15 Metal Low-E Double Yes 0.46 0.26 24.0 ft2 14 ft 0 in 0 ft 8 in Drapes/blinds None
11 N=>S 15 Metal Low-E Double Yes 0.5 0.25 96.0 ft' 14 ft 0 in 3 ft 6 in Drapes/blinds None
12 E=>W 16 Metal Low-E Double Yes 0.46 0.26 6.0 ft2 15 ft 8 in 1 ft 3 in Drapes/blinds None
13 E=>W 16 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 15 ft 8 in 3 ft 4 in Drapes/blinds None
14 NE=>SW17 Metal Low-E Double Yes 0.46 0.26 6.0 ft2 6 ft 4 in 1 ft 3 in Drapes/blinds None
15 NE=>SW17 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 6 ft 4 in 3 ft 4 in Drapes/blinds None
16 N=>S 18 Metal Low-E Double Yes 0.46 0.26 6.0 ft2 5 ft 9 in 1 ft 3 in Drapes/blinds None
17 N=>S 18 Metal Low-E Double Yes 0.49 0.24 18.0 ft2 5 ft 9 in 3 ft 4 in Drapes/blinds None
18 E=>W 19 Metal Low-E Double Yes 0.25 0.18 10.3 ft2 23 ft 2 in 4 ft 5 in Drapes/blinds None
19 N=>S 20 Metal Low-E Double Yes 0.46 0.26 24.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
20 N=>S 20 Metal Low-E Double Yes 0.49 0.24 72.0 ft2 1 ft 0 in 3 ft 0 in Drapes/blinds None
21 W=>E 21 Metal Low-E Double Yes 0.46 0.26 24.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds None
22 W=>E 21 Metal Low-E Double Yes 0.49 0.24 15.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
23 W=>E 21 Metal Low-E Double Yes 0.49 0.24 9.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
24 W=>E 21 Metal Low-E Double Yes 0.49 0.24 15.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 800 ft2 800 ft2 96.66 ft loft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 . Wholehouse Proposed ACH(50) .000318 2570.8 141.14 265.43 .2383 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat None COP:1 42 kBtu/hr 1 sys#1
2 Electric Strip Heat None COP:1 18 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 16 42 kBtu/hr 1260 cfm 0.75 1 sys#1
2 Central Unit Split SEER: 16 18 kBtu/hr 540 cfm 0.75 2 sys#2
3/29/2017 4:17 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
1
FORM'R405-2014
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
•/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 318.9 ft Attic 79.725 Proposed Qn 1 st Floor A ---cfm 144.2 cfm 0.07 0.50 1 1
2 Attic 6 318.9 ft Attic 79.725 Proposed Qn 1 st Floor B ---cfm 71.8 cfm 0.07 0.50 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: N
i
CoolingJan Feb Mar ]A r [ ]Ma [X]Jun [X]Jul rl Au Se [ ]Oct [ ]Nov Dec
Heatin HJan X Feb X�Mar E_]APr [ I May E ]Jun E ]Jul AuIXI
SeP [ ]Oct [X]Nov X Dec
Ventin Jan [ Feb X Mar [X]A r [ ]Ma ]Jun ]Jul Aug Se [XI Oct (X]Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
3/29/2017 4:17 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
3400 BENT PINE DR., FL, 34951
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2809.50 ftz
b.Frame-Steel,Adjacent R=11.0 260.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a. Under Attic(Vented) R=30.0 3085.00 ftz
6. Conditioned floor area(ftz) 3085 b.N/A R= ftz
7. Windows- Description Area c. A R= ft
z
a. U-Factor: Dbl, U=0.49 277.00 ftz 11. Ducts R ftz
a.Sup:Attic, Ret:Attic,AH: 1st Floor 6 318.9
SHGC: SHGC=0.24 b.Sup: Attic,Ret:Attic,AH: 1 st Floor B 6 318.9
b. U-Factor: Dbl,U=0.46 133.82 ftz
SHGC: SHGC=0.26 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.50 96.00 ftz a.Central Unit 42.0 SEER:16.00
SHGC: SHGC=0.25 b.Central Unit 18.0 SEER:16.00
d. U-Factor: other(see details) 10.29 ftz 13.Heating systems kBtu/hr Efficiency
SHGC: other(see details) a.Electric Strip Heat 42.0 COPA.00
Area Weighted Average Overhang Depth: 5.990 ft. b.Electric Strip Heat 18.0 COP:1.00
Area Weighted Average SHGC: 0.246
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 3085.00 ftz EF:0.95
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I ce>tify that this home has complied with the Florida Energy Efficiency Code for Building iIIE Sp
Construction through the above energy saving features which will be installed (or exceeded) 0 _ ATA
0�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compli ant features.
Builder Signature: Date:
Address of New Home: FV00 l .2 a, City/FL Zip:
WE
3 Lms i
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/29/2017 4:19 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
I