HomeMy WebLinkAboutProduct Approval (4) 1/16/2017 Florida Building Code OnlinE 4
M7
BCIS Home Log in User Registration Hot Topics i Submit Surcharge I Stats&Facts I Publications FBC Staff BCIS Site Map I Links I Search
' Florida
�^ *Product Approval
USER:Public User
d File C
- k Product Approval Menu>product or Aoolication Search>Application List>Application Detail Copy
FL# FL9174-R11
! . Application Type Revision
Code Version 2014
Application Status Approved
Comments set to re-apply per applicants request 4/28/15-rb
Archived
Product Manufacturer Wayne-Dalton, a•division of Overhead Door Corporation
Address/Phone/Email 3395 Addison Drive
Pensacola, FL 32514
(850)474-9890
Mark—Garon@Overheaddobr.com
Authorized Signature Greg Taylor
gtaylor@Wayne-Dalton.com
Technical.Representative Greg Taylor
Address/Phone/Email 3395 Addison Drive
Pensacola, FL 32514
(850)474-9890
gtaylor@wayne-dalton.com
Quality Assurance Representative
Address/Phone/Email
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report-Hardcopy Received
t
". Florida Engineer or Architect Name who developed John E. Scates
the Evaluation Report
Florida License PE-51737
Quality Assurance Entity Intertek Testing Services NA,Inc.
Quality Assurance Contract Expiration Date 06/27/2038
Validated By Kurt Dietrich PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL9174'RII COI Cert of Ind Scates 2011 s.odf
Referenced Standard and Year(of Standard) Standard Year
DASMA-108 2002
DASMA-115 2005
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilcing.org/pr/pr app dtl.aspx?param=wGEVXQwtDqufliJRfWxf6u7ojnl0heH%2bRKJkizESWxAzegKuY8GeGQ%3d%3d 1/6
1/16/2017 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 04/06/2015
Date Validated 04/28/2015
Date Pending FBC Approval 05/04/2015
Date Approved 06/23/2015
Summary of Products
FL# Model,Number or Name Description
9174.1 5120/6100/9100#0228 9'Max width.8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 R11 II 0228 318958 P7.pdf _
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.pdf
Impact Resistant:Yes - FL9174 Rll II WD3ambSupolementP16 s.odf
Design Pressure: +26.90/-30.80 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Created by Independent Third Party: Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.1)df
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party:Yes -
9174.2 5120/6100/9100#0229 16'Max width. 8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0229 318959 P8.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.pdf
Impact Resistant: No FL9174 Rll II WDJambSupplementPl6 s.odf
Design Pressure: +15.30/-17.00 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. FL9174 Rif AE Eval Rept 9100 rl s.pdf
FL9174 Rll AE FL09174 r9 Affirmation for FBC 5th 2014s.odf
Created by Independent Third Party: Yes
91743 5120/6100/9100#0230 16'Max width. 8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 Rll II 0230 318960 P10.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.pdf
Impact Resistant:Yes FL9174 R11 II WDJambSupolementP16 s.pdf
Design pressure: +25.90/-28.80 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Created by Independent Third Party:Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.pdf
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party:Yes -
9174.4 5120/6100/9100#0231 16'Max width. 8'-9" Max height. Max section height 21". Solid
only-no glazing available.
Limits of Use Installation Instructions
Approved for use in HVHZ: No ' FL9174 Rll II 0231 318996 P5.pdf
Approved for use outside HVHZ:Yes FL9174 Rll II Track Supplement Chart P10.odf
Impact Resistant:Yes FL9174 Rll II WDJambSuPPlementP16 s.pdf
Design Pressure:+30.00/-33.50 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party: Yes
9174.5 5120/6100/9100#0234 9'Max width.8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0234 319022 P5.pdf
Approved for use outside HVHZ:Yes FL9174 Rll II Track Supplement Chart P10.pdf
Impact Resistant:Yes FL9174 Rll II WDJambSupplementP16 s.pdf
Verified By:John E. Scates P.E. FLORIDA PE 51737
https://www.f cridabuilding.org/pr/pr app dtl.aspx?param=wGEVXQwtDqufllJRfWxf6u7ojnlOheH%2bRKJkizESWxAzegKuY8GeGQ%3d%3d 216
1/16/2017 Florida Building Code Online
Design Pressure: +43.20/-49.60 Created by Independent Third Party: Yes
Other: Evaluation Reports
FL9174 R11 AE ASTM A 653.pdf
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party:Yes
9174.6 5120/6100/9100#0235 16'Max width. 8'Max height. Max section height 21". Glazing
- available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 R11 II 0235 319023 P6.pdf
Approved for use outside HVHZ:Yes FL9174 Rll II 319040 Pl Post.ndf
Impact Resistant:Yes FL9174 Rll II Track Supplement Chart P10.pdf
t Design Pressure: +39.20/-43.70 FL9174 R11 II WDJambSupplementP16 s.pdf
1 Other: Verified By:John E. Scates P.E. FLORIDA PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.pdf -
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.odf
Created by Independent Third Party: Yes
9174.7 5120/9100#0232 18'Max width. 8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 Rll II 0232 318999 PS.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.pdf
Impact Resistant: No FL9174 Rll II WDJambSupplementPl6 s.pdf
Design Pressure: +12.40/-13.80 Verified By:John E.Scates P.E. FLORIDA PE 51737
Other:Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 Rll AE ASTM A 653.odf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf.
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.odf
Created by Independent Third Party: Yes
9174.8 5120/9100#0233 18'Max width. 8'-9" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 Rll II 0233 319000 P5.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.odf
Impact Resistant: No FL9174 R11 II WDJambSupplementP16 s.pdf
Design Pressure: +18.50/-20.70 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party:Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party: Yes
9174.9 5120/9100 #0236 18'Max width. 8'Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 Rll'II 0236 319024 P6.pdf
Approved for use outside HVHZ:Yes FL9174 Rll II 319040 PI Post.pdf
Impact Resistant:Yes FL9174 R11 II Track Supolement Chart P10.pdf
Design Pressure: +30.00/-33.50 FL9174 Rll II WDJambSupplementP16 s.pdf
Other: Verified By:John E. Scates P.E. FLORIDA PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.pdf
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.ndf
Created by Independent Third Party: Yes
9174.10 5120/9100#0237 18'Max width. 8'Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ, No FL9174 Rll II 0237 319025 P6.)df
Approved for use outside HVHZ:Yes FL9174 Rll II 319040 P1 Post.pdf
Impact Resistant:Yes FL9174 Rll II Track Supplement Chart P10.Pdf
Design Pressure: +39.20/-43.70 FL9174 Rll II WDJambSupplementP16 s.pdf
Other: Verified By:John E.Scates P.E. FLORIDA PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.pdf
FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party:Yes
ht4ml/www.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDqufl1JRfWxf6u7ojnlOheH°/a2bRKJ.kizESWxAzegKuY8GeGQ%3d°/a3d 3/6
1/16/2017 Florida Building Code Online
i ht Max section height 24". Glazing 9174.11 5120/5140/6100/9100/9400/9600 9'Max width. 10'Max he g/ 9 9
#0600 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0600 319026 P4.1)df
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.Ddf
Impact Resistant: No FL9174 R11 II WDJambSuoolementPl6 s.pdf
Design Pressure:+26.90/-30.80 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other:Doors with glazing shall not be used in the wind-: Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. . FL9174 R11 AE Eval Rept 9100 rl s.pdf -
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.odf
Created by Independent Third Party:Yes
t
9174.12 5120/5140/6100/9100/9400/9600 9'Max width. 10'Max height. Max section height 24"Glazing
#0601 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0601 319027 P4.Pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.odf
Impact Resistant:Yes FL9174 R11 II WDJambSupplementP16 s.pdf
Design Pressure: +41.00/-46.30 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Created by Independent Third Party: Yes -
Evaluation Reports .
FL9174 R11 AE ASTM A 653.pdf
FL9174 R11 AE Eval Reot 9100 rl s.pdf
FL9174 R11 AE FLO9174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party: Yes
9174.13 5120/5140/6100/9100/9406/9600 16'Max width. 10'Max height. Max section height 24". Glazing
#0602 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0602 319028 P5.odf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.pdf
Impact Resistant:No FL9174 Rll II WDJambSupplementP16 s.pdf
Design Pressure: +15.30/-17.00 Verified By:John E. Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 Rll AE ASTM A 653:pdf
door. FL9174 R11 AE Eval Reot 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party:Yes
9174.14 5120/5140/6100/9100/9400/9600 16'Max width. 10'Max height. Max section height 24". Glazing
#0603 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 R11 II 0603 319029 PS.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.odf
Impact Resistant:No FL9174 Rll II WDJambSuoolementP16 s.pdf
Design Pressure: +23.00/-25.00. Verified By:John E.Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party:Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 Rll AE ASTM A 653.pdf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.odf
Created by Independent Third Party: Yes
9174.15 5120%5140/6100/9100/9400/9600 16'Max width. 8'Max height. Max section height 24"Glazing
#0604 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 Rll II 0604 319030 PS.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II 319040 Pl Post.odf
Impact Resistant:Yes FL9174 Rll II Track Supplement Chart P10.pdf
Design Pressure: +39.20/-43.70 FL9174 R11 II WDJambSuoolementP16 s.pdf
Other: Verified By:John E Scates P.E. FLORIDA PE 51737
Created by Independent Third Party: Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.odf
FL9174 R11 AE Eval Rept 9100 rl s.odf
FL9174 Rll AE PL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party: Yes.
.9174.16 5120/5140/6100/9100/9400/9600 18'Max width. 10'Max height. Max section height 24". Glazing
#0605 available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 Rll II 0605 319031 P4.pdf
Approved for use outside HVHZ:Yes FL9174 Rll II Track Supplement Chart P10.odf
Impact Resistant: No FL9174 Rll II WDJambSupplementPl6 s.pdf
https://www.floridabuilding.orglpr/pr app_dtl.aspx?param=wGEVXQvADquflJRfVVxf6u7ojnlOheH%2bRKJkizESWxAzegKuY8GeGQ°/"3d%3d 4/6
1/16/2017 Florida Building Code Online
Design Pressure: +15.30/-17.00 Verified By:John E Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party:Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 6S3.Ddf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FLO9174 r9 Affirmation for FBC-5th 2014s.pdf
Created by Independent Third Party:Yes
9174.17 5120/5140/6100/9100/9400/9600 18'Max width.8'Max height. Max section height 24" Glazing
#0606 available in top or intermediate section.
Limits of Use Installation Instructions
Approved.for use in HVHZ:No FL9174 Rll II 0606 319032 P6.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II 319040 Pi Post.pdf
Impact Resistant: No FL9174 Rll II Track Supplement Chart P10.pdf
Design Pressure: +30.00/-33.50 FL9174 Rll II WDJambSupDlementP16 s.pdf
Other: Doors with glazing shall not be used in the wind- Verified By:John E Scates P.E. FLORIDA,PE 51737
borne debris region unless protected or unless structure is Created by Independent Third Party:Yes
designed as partially enclosed or door is a replacement Evaluation Reports
door. FL9174 R11 AE ASTM A 653.Ddf
FL9174 R11 AE Eval Reot 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.Ddf
Created by Independent Third Party:Yes
9174.18 5120/5140/6100/9100/9400/9600 18'Max width: 8'Max height. Max section height 24" Solid only-
#0609 no glazing available.
Limits of Use Installation Instructions
Approved for use in HVHZ:No FL9174 R11 II 0609 319035 P5.odf
Approved for use outside HVHZ:Yes FL9174 R11 II 319040 PI Post.Ddf
Impact Resistant:Yes FL9174 R31 II Track SUDDlement Chart P10.pdf
Design Pressure: +39.20/-43.70 FL9174 Rll II WDJambSupolementPl6 s.pdf
Other: Verified By:John E Scates P.E. FLORIDA PE 51737
Created by Independent Third Party:Yes
Evaluation Reports
FL9174 R11 AE ASTM A 653.1)df
FL9174 R11 AE Eval Rept 9100 rl s.odf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party: Yes
9174.19 5140/6100/9400/9600#0608 18'Max width. 8'-9"Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 Rll II 0608 319034 P4.pdf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.odf
Impact Resistant: No FL9174 R11 II WD3ambSupplementP16 s.pdf
Design Pressure: +18.50/-20.70 Verified By:John E Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party:Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. FL9174 R11 AE Eval Reot 9100 rl s:pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC Sth 2014s.pdf
Created by Independent Third Party: Yes
9174.20 5140/9400/9600#0607 16'Max width. 8'-g" Max height. Max section height 21". Glazing
available in top or intermediate section.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL9174 R11 II 0607 319033 P5.Ddf
Approved for use outside HVHZ:Yes FL9174 R11 II Track Supplement Chart P10.Ddf
Impact Resistant:No FL9174 Rll II WDJambSupplementP16 s.pdf
Design Pressure: +25.90/-28.80 Verified By:John E Scates P.E. FLORIDA PE 51737
Other: Doors with glazing shall not be used in the wind- Created by Independent Third Party: Yes
borne debris region unless protected or unless structure is Evaluation Reports
designed as partially enclosed or door is a replacement FL9174 R11 AE ASTM A 653.pdf
door. FL9174 R11 AE Eval Rept 9100 rl s.pdf
FL9174 R11 AE FL09174 r9 Affirmation for FBC 5th 2014s.pdf
Created by Independent Third Party: Yes
Bacic Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emaiis provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a
personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter
455,F.S.,please click here.
Product Approval Accepts:
httpsl/www.flaridabuilding.org/pr/pr app df.aspx?param=wGEVXQwtDqufiJRfWAu7oin[OheH`/g2bRKJkizESWxAzegKuY8GeGQg/o3d%3d 5/6
1/16/2017 Florida Building Code Online
. ®® eClie�k
Credit Card
Sate
https:/twww.floridabuilding.orgtpr/pr app dtl.aspx?param=wGEVXQwtDqufllJRfVVxf6u7ojnl0heH%2bRKIkizESWxAzegKuY8GeGQ%3d%3d 6/6