ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 65
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12. Ducts, location & insulation level
a) Supply ducts R
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
c) AHU location
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
0
13. Cooling system: Capacity
10.9
a) Split system SEER
19.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
390
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.050
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
10.9
c) Area
7c.
18.0
a) Split system heat pump HSPF
9.0
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be compl4d bWd on j0staflo code compliant features.
Builder Signature: / GI / 11��) Date:.. Il /I � z
�-
Address of New Home: 6505 LAKELAND BLVD. City/FL Zip: FT. PIERCE, FL
11/17/2020 8:01:00 AM EnergyGauge@ USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
' ProjectName: ROBERT MATTHEWS
BuilderName:
Street: 6505 LAKELAND BLVD.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PennitNumber:
Owner. ROBERT MATTHEWS
Jurisdiction: 6611000
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing Addition
9. Wall Types (656.0 sqft.)
Insulation Area
a. Concrete Block - Int Insul, Exterior
R=4.1 656.00 ft2
2. Single family or multiple family Single-family
b. WA
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms (Bedrms In Addition) 0(0)
d. N/A
10. Ceiling Types (390.0 sqft.)
R= ft2
Insulation Area
5. Is this a worst case? No
a. UnderAttic (Vented)
R=30.0 390.00 ft2
6. Conditioned floor area above grade (ft2) 390
b. N/A
R= ft2
ft2
c. N/A
R=
Conditioned floorareabelow grade (ft2) 0
11. Ducts
R ft2
7. Windows(18.0 sqft.) Description Area
a. U-Factor: Sgl, U=1.05 18.00 ft2
SHGC: SHGC=0.25
Cooling systems
kBtu/hr Efficiency
b. U-Factor: N/A ft2
a. Central Unit
a.
10.9 SEER:19.00
SHGC:
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A ft2
a. Electric Heat Pump
10.9 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
14. Hot water systems -None required
Area Weighted Average SHGC: 0.250
A
Cap: N/A
8. Floor Types (390.0 sqft.) Insulation Area
a.
EF:-0.028
a. Slab -On -Grade Edge Insulation R=0.0 390.00 ft2
b. Conservation features
b. N/A R= ft2
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 9.21
PASS
Glass/Floor Area: 0.046 Total Baseline Loads: 14.08
1 hereby certify that the plans and specifications covered by
Review of the plans and
OF `C14E S44'
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
Qthis
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE: - -
building will be inspected for
compliance with Section 553.908
I hereby certify that theing, s de igned, is in compliance
Florida Statutes.
�
with the Florida EnergCOB
T OWNER/AGE :
BUILDING OFFICIAL:
I
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
11/17/2020 8:00 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
GrIORA DAnr,-7r117 INPI IT SI IMMORY CHECKLIST REPC)RT
PROJECT
Title:
ROBERT MATTHEWS
Bedrooms: 0
Address Type: StreetAddress
Building Type:
User
ConditionedArea: 390
Lot#
OwnerName:
ROBERT MATTHEWS
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: No
PlatBook:
' BuilderName:
RotateAngle: 0
Street: 6505 LAKELAND BLVD.
Permit Office:
ST. LUCIE COUNTY
CrossVentilation: No
County: St. Lucie
Jurisdiction:
6611000
Whole House Fan: No
City, State, Zip: FT. PIERCE,
FamilyType:
Single-family
FL,
New/Existing:
Addition
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design DailyTemp
Designi-ocation
TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
390 3120
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
NEW OFFICE
225 1800 No 0
1 Yes Yes Yes
2
NEW LAUNDRY
165 1320 No 0
1 Yes Yes Yes
FLOORS
#
FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value Tile Wood Carpet
1 Slab -On -Grade Edge Insulation
NEW OFFICE 45 ft 0
225 ftZ
____ 0 1 0
2 Slab -On -Grade Edge Insulation
NEW LAUNDRY 37 ft 0
165 ft2
____ 0 1 0
ROOF
Roof Gable Roof
Rad
Solar SA Emitt Emitt Deck Pitch
#
Type Materials Area Area Color
Barr
Absor. Tested Tested Insul. (deg)
1
Hip Compositionshingles 422 ftz 0 ft= Medium
N
0.6 No 0.9 No 0 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150
390 ftz
N N
11 /17/2020 8:00 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
,..� M101 M e1 IRAAeAvv HZT RGPART
rvr%nn MWU-cv i i .■.■ v . ...........�... -- -- - -- - -
CEILING
#
CeilingType Space R-Value Ins Type
Area
Framing Frac Truss Type
1
2
Under Attic (Vented) NEW OFFICE 30 Blown
UnderAttic(Vented) NEW LAUNDRY 30 Blown
225 ft2
165ft2
0.1 Wood
0.1 Wood
WALLS
Adjacent Space Cavity Width Height
'lie Et In Et In
Area
Sheathing Framing Solar
R-Nhallle- ELaCtinn Absor
Below
0
_ 1
_ 2
_ 3
_ 4
_ 5
6
NE
SW
NW
NE
SE
SW
Exterior Concrete Block - Int lnsLWEW OFFICE 4.1 15 0 8 0
Exterior Concrete Block- Int InsLNEW OFFICE 4.1 15 0 8 0
Exterior Concrete Block- Int Insd11EW OFFICE 4.1 15 0 8 0
Exterior Concrete Block- Int InsuNEW LAUND 4.1 11 0 8 0
Exterior Concrete Block - Int InsuNEW LAUND 4.1 15 0 8 0
Exterior Concrete Block- Int InsuNEW LAUND 4.1 11 0 8 0
120.0 ft2
120.0 ftZ
120.0 ft2
88.0 ft2
120.0 ft2
88.0 ft2
0 0 0.6
0 0 0.6
0 0 0.6
0 0 0.6
0 0 0.6
0 0 0.6
0
0
0
0
0
0
DOORS
#
Ornt DoorType Space Storms U-Value
Ft
Width Height
In Ft In
Area
1
SE Insulated NEW LAUND None .39
3
6 8
20 ft2
WINDOWS
Orientation shown istheentered,Proposed orientation.
#
Wall
Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area
Overhang
Depth Separation IntShade
Screening
1
2
SW 2 Metal Low-ESingle Yes 1.05 0.25 N 9.0 ft2
NW 3 Metal Low-ESingle Yes 1.05 0.25 N 9.0 ft2
2 ft 0 in
2 ft 0 in
1 ft 4 in None
1 ft 4 in None
None
None
INFILTRATION
#
Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 260 14.27 26.84
.0881
5
HEATING SYSTEM
#
System Type Subtype Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/Existing/co Split Single HSPF:9 10.9kBtu/hr
1
Ductless
COOLING SYSTEM
#
System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
CentralUnit/Existing/confirmed Split Single SEER: 19 10.9 kBtu/hr
cfm 0.7 1
Ductless
11 /17/2020 8:00 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
Cr%oa. MAAC IKIPI IT CI IMIIAORV r14FMCI 1ST RFPnRT
V.live .\---LV,.
--
- -
---------
----
----
.
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
• Cert #
CompanyName
System Model#
CollectorModel#
Area
Volume
FEF
ftZ
•
TEMPERATURES
Y
Thermostat::H
ProgramableHJan
Ceiling Fans:
Heating Jan
Feb
M Mar
Apr
n
1
rl
Aug
Au
ep
Sep
Oct
Oct
Nov
Dec
H DecVenting
Feb.
Mar
Apr
May
Jun
Jul
XMNov
ThermostatSchedule:
HERS 2006 Reference
Hours
ScheduleType
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
78
78
78
78
78
80
78
80
78
80
78
80
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66
68
66
68
68
68
68
68
68
68
68
68
68
68
68
66
68
66
MASS
Mass Type
Area
Thickness
FumitureFraction
Space
Default(8lbs/sq.ft.
0 ftZ
0 ft
0.3
NEW OFFICE
Default 8lbs/s .ft.
ftZ
ft
0.3
NEW LAUNDRY
11 /17/2020 8:00 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
Project Summa
-- wrightsoft® Entire House ry Dab:
u
QUICK CALCS, INC.
317 ST. LUCIE LANE, Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOLCOM
Project• •
For. ROBERT MATTHEWS
6505 LAKELAND BLVD., FT. PIERCE, FL 34951
Notes:
Design. Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grub
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 7382
Btuh
Structure
6366
Btuh
Ducts 946
Btuh
Duds
1405
Btuh
Central vent (0 cfm) 0
Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 8329
Btuh
Use manufacturer's data
n
Rate/sw in multiplier
0.95
7383
Ruh
Infiltration
EquipmenI sensible load
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
1382
Btuh
Ducts
362
Btuh
Central vent (0 cfm)
0
Btuh
Heatingg
F)
Cooling
(none)
1744
Btuh
Area (f 390
390
Equipment latent load
Molume (`[P) 3510
3510
Airchanges/hour 0.61
0.32
Equipment Total Load Sen+Lat)
9127
Btuh
Equiv. AVF (cfm) 36
19
Req. total capacity at 0.70 SHR
0.9
ton
Heating Equipment Summary
Cooling Equipment Summary
Make DIAKIN
Make MAKIN
Trade
Trade
Model RX12NMVJU
Cond RX12NMVJU
AHRI ref 8064266
Coil FTX12NMVJU
AHRI ref 8064266
Efficiency 9 HSPF
Efficiency 12.5 EER,19 SEER
Heating input
Sensible cooling
7630
Btuh
Heating output 11400
Btuh @ 47°F
Latent doling
3270
Btuh
Temperature rise 28
OF
Total 000ling
10900
Btuh
Actual airflow 367
cfrn
Actual airflow
367
cfm
Air flow factor 0.044
cfm/Btuh
Airflowfactor
0.047
cfm/Btuh
Static pressure 0
in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.82
Capacity balance point = 35 OF
Backup:
Input = 2 kW, Output = 7298 Btuh, 100AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
w�igF�ts®Ft ° 2020-Nov-1707:48.49
........... .. Rigtt-SUte4DUtmsal201919.021 RSUBB101
Pagel
14C(�k 1DoamertslWrightroftWACWIATIHEWS,ROBERrW Calc=MJ8 FmdDoorfaces: N
r- wright�soft, Right-J® Worksheet Job.
W.
Entire House Da.
y QUICK CALCS, INC. sy
317 ST I I IMP I ANF FT RrPr.F R 'AdQdR Ph— 779_di AW10 F:—il- nl firle(`nl flQfTftnl rMA
1
Room name
Entire House
NEWOFRCE
2
Eposedvdl
82.0 ft
45.0 ft
3
Room Wght
9.0 ft
9.0 ft heattool
4
5
Room dimensions
Room area
390.0 fl?
15.0 x 15.0 ft
225.0 f'
Ty
Construdion
U-value
or
HTM
Area OF)
Load
number
(BhlhAF-'F)
(BluhlfE)
or Perimeter (ft)
(Bhlh)
orperimeetter (it)
(BEuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
NIPIS
Heat
Cool
6
11
W
W
D.
73AAoi5
13AAocs
11D0..
13E44acs-'
1A om . s
0.143
0.143
0.390
6443
1270
: ne'
se
se_
:"sw
." sWi
4.00
4.00
10.92
4.66
; 35.56
219
2.19
10.34
'2.19
41.04
' 234
135
20
234
9
. 234
115
20
225
- ' - 7
_ 937
459
223
901
.: 320''.
" 612
251
211
- . '492'',
369
135
0
.. 0
135
9
135
0
.. 0
126
7
. 544
0
0
505
, 295
0
0
276
gyp►
G
VN
�--G,
13A4ocs
1Ad9m.
16B30ad
0.143
1270
0:032
nw
nw
. ` '
4.00
35.56
- . ` 0.90.
219
70.43
1.60
135
9
390
126
_ 0
390
505
320
276
_ 634
624
135
9
. 225
126
0
225
505
320
276
634
• 360'
C
F
27J11p1
0.989
_ -
27.69
0.00
390
_82
2271
0
225.
45
1246
.. 0
61
c) AED exauson
1
599
1
599
EnWopeloss/gain
6264
3968
3637
28M
12
a) Infilhatlon
1098
309
603
169
b) Room verrtlation
0
0
0
0
13
hlemalgains O=Parrts@ 230
3
690
3
690
Appliances/other
1400
900
SubliDU (lines6 to 13)
7382
6366
4240
4568
Lessexternalload
0
0
0
0
Lesstlarlslbr
0
0
0
0
Redistribution
0
0
0
0
14
SubtDW
7382
6366
4240
4568
15
Dudloads
13%
22-A
946
1405
13%
22%
544
1008
Total room load
8329
7771
4783
5576
Air required (dm)
367
367
211
263
Calculations approved WACCA to meet all requirements of Manual J 8th Ed.
_ wriNgF�tsoft 2020-Nov-1707.48:49
Riglt-SUfe@Lhtversal201919.021 RSU08101 Page 1
-.Uoamerls\WrightsoftWACNATTHEWS,ROBERfn>p Calo=MJ8 FrortDoorfaws: N
- wrightsoft
I
Right-JO Worksheet Jaw.
Entire House °r'
QUICK CALCS, INC.
' 317 ST. LUCIE LANE, Fr. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@ AOLCOM
1
Room name
NEW LAUNDRY
2
EVosedvdl
37.0 ft
3
Room height
9.0 tt heabbool
4
Room dimensions
15D x 11.0 8
5
Room area
165.0 iF
Ty
Conslrrxdon
number
U-value
(Btuhfif `F)
Or
HTM
Area OF)
or perimeter (11)
Load
(Bluh)
Area
or perimeter
Load
Heat
Caol
Gross
NOS
Heat
Cool
Gross
NIPS
Heat
Cool
6
11
W
1�
I---D
13AAocs
13AAocs
11D0
13AAacs
-IXd rri
w43
0.143
0.390
0.143
1270
: no
se
se
_ sw
.-5w
4.66
4.00
10.92
4.00
35.56
2:10
2.19
10.34
2i9
41.64
` �90
135
20
'. 99
0
: .99
115
20
99
0
306
459
223
.. 396
' 0
:. 217
251
211
�217
- "0
W
-C
.
VqI
r G
13AAacs
IA-dom
16B30ad
0.143
1270
0.032
nw
nw
. - .
4.00
35.56
0.90
219
70.43
; 1:60
0
0
.. 165
0
0
` :165
0
0
148
0
0
> 264
..
C .
F
22A4pl
0.989
-
27.69
0.00
165
- 37
1025
6
c) AED emasion
0
EnWope ladgain
2647
1159
12
a) Infiltration
b) Room ventilation
495
0
139
0
13
Internal gains Occupant@ 230
0
0
Applianoestother
500
SubbW (lines6to 13)
3142
1798
Less external load
0
0
L.esstransfer
0
0
Redistribution
0
0
14
Subbtal
3142
1798
15
Ductloads
13%
22-A
403
397
Total room load
A3156
545
2104
Air required (dm)
195
Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed.
_ +d- wrigtitsoft 2020-Nov-1707:48:49
ACC. Right-Suite®Urrversal201919.021RSU08101 Page
...1Doarrerts\WrighbMH\tAGNATiHEWS,ROBERrw Calc=MJB FrortDoorfaces N
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 65
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. Addition
12. Ducts, location & insulation level
a) Supply ducts R
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
c) AHU location
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
0
13. Cooling system: Capacity-1-0-2
-
a) Split system SEER 19.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
390
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
1.050
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity---1-O.-9
c) Area
7c.
18.0
a) Split system heat pump HSPF 9.0
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
6.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation No
b) Single assembly
11 b.
c) Whole house fan No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be com 4bd on ' sta d code compliant features.
Builder Signature: C ' Date: It //7
Address of New Home: 6505 LAKELAND BLVD. City/FL Zip: FT. PIERCE, FL
11 A 7/2020 8:01:00 AM . EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: , ROBERT MATTHEWS Builder Name:
Street: 6505 LAKELAND BLVD. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
v
Owner: ROBERT MATTHEWS Jurisdiction: 6611000
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermalresistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipong and wiring-
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
11/17/2020 8:01 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1