HomeMy WebLinkAboutBuilding PlansMASTER CLOSET I STER BEDROOM iiMASTER BATHO$_ i H I O I BATH 2` L J 13 0 3 LILTING ROOM 10J d KITCHEN! DUE TO THE NATURE OF THE PROJECT THE CONTRACTOR SHALL VERIFY ALL ASSUMPTIONS AND CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO CONSTRUCTION. NOTIFY ENGINEER IF CONDITIONS DIFFER FROM NOTED. DEMO PLAN 1/4"=V-0" SCALE 12 ®�O BEDROOM Scope of Work INTERIOR RENOVATION & WINDOW/DOOR REPLACEMENT IN EXISTING OPENING Building Code 2017 Florida Building Code: Residential 2014 National Electric Code DEMO NOTES: REMOVE EXISTING TILE, ADHESIVE AND LEVELING MATERIAL IN KITCHEN AND ENTRY. REMOVE ALL CARPETING THRU OUT CONDOMINIUM O REMOVE EXISTING TILE AND THIN SET ON BALCONY ® REMOVE EXISTING KITCHEN CABINETS AND ASSOCIATED HARDWARE O REMOVE EXISTING SINK AND ASSOCIATED HARDWARE © REMOVE EXISTING ELECTRIC STOVE t�7 REMOVE EXISTING REFRIGERATOR �8 REMOVE EXISTING DISHWASHER O9 REMOVE ALL EXISTING DOORS INCLUDING THE SLIDING GLASS DOORS AND HARDWARE IN UNIT (ENTRY DOOR TO REMAIN) REMOVE EXISTING TOILETS IN MASTER BATH AND GUEST BATHROOM © REMOVE EXISTING VANITIES IN MASTER BATH AND GUEST BATHROOM © REMOVE ALL SINKS/COUNTERTOP, VALVES AND ASSOCIATED HARDWARE IN MASTER BATH AND GUEST BATHROOM REMOVE ALL GYP BOARD OFF INTERIOR WALLS IN UNIT ® REMOVE ALL MASTER AND GUEST BATHROOM LIGHTING. REMOVE ALL WIRING TO SOURCE ® REMOVE EXISTING SHOWER AND ASSOCIATED HARDWARE IN MASTER BATH AND GUEST BATH r1�6 REMOVE EXISTING WALL SECTION AS SHOWN @ REMOVE EXISTING BATHROOM EXHAUST FANS ® REMOVE ALL EXISTING OUTLETS AND SWITCHES THRU OUT UNIT REMOVE EXISTING AIR HANDLER REMOVE EXISTING WINDOWS DEMO LEGEND — — — — — — EXISTING TO BE REMOVED EXISTING TO REMAIN 2o(o-00s4 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY �'r °� �i )W�J�4 oJ",t—a L SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 66080 �����11ifllP� v > Ito z 0 a a u w Q Q z 0 w a O W W U� o Z Q�0 �O U Cr DATE DESIGNED GMVJ 09-13-20 DRAWN GMW 09-13-20 CHECKED JOB NO. 2020-300 Aml .W PRODUCT APPROVAL Approval Product Model Number Manufacturer Glass Attachment Method Building Rated Product Rated Number Type Design Pressures Design Pressures NOA. 20-0713.02 S.H. Windows 7500 Lawson Non Impact 1/4" tapcons or @12 sms screws see product approval +59.4/-62.0 +/— 62.9 chart for anchors required NOA. 17-1212.06 SlidingGlass Door 9000 Lawson Non Impact 1/4" Tapcons in concrete or masonry +55/-59.1 +56.7/-60.4 (2 panel) w/1-1/4" min Embed See Product Approval for Spacing Lawson Impact NOA. 18-0529.03 Mullion Aluminum Tube Lawson Impact See Product Approval Sheet for Installation +59.4/-62.0 +/— 150 Mullions Sliding Glass Door +51.6/-56.5 4 Panel MASTER CLOSET Q 4 ®% MASTER Q 2 MASTER BEDROOM ® ❑ $❑ BATH �� Q Q 7 H 1 1 1 1 19 Q 1® ® (BEEDROO�O, M 2 BATH 2 8 ®a ®LIN 0 ® DQ® AREA OF NEW WALL 1 1 9 ® LIVING ROOM KITCHEN O O Q 0 O 0 PROPOSED FLOOR PLAN 1/4"=V-0" SCALE NOTE: PRIOR TO INSTALLING ANCHORS, FIELD VERIFY IF EXISTING PRE STRESSING STEEL EXISTS. CARE SHALL BE TAKEN SO AS NOT TO DAMAGE EXISTING REINFORCING DURING ANCHOR INSTALLATION. NEW WORK NOTES: 0 NEW VINYL FLOORING THRU OUT ENTIRE CONDOMINIUM. 02 NEW WHITE SHAKER STYLE KITCHEN CABINETS AND ASSOCIATED HARDWARE O3 NEW SINK AND ASSOCIATED HARDWARE ® NEW ELECTRIC STOVE O NEW REFRIGERATOR ® NEW GARBAGE DISPOSAL �7 NEW DISHWASHER AND ASSOCIATED HARDWARE ® NEW DOORS THRU OUT ENTIRE UNIT INCLUDING THE SLIDING GLASS DOORS AND HARDWARE (ENTRY DOOR TO REMAIN). SLIDER INSTALLED IN EXISTING OPENING. O9 NEW TOILETS VALVES AND ASSOCIATED HARDWARE IN MASTER BATH AND GUEST BATHROOM lJ NEW VANITIES IN MASTER BATH AND GUEST BATHROOM © NEW SINK/COUNTER, VALVES AND ASSOCIATED HARDWARE IN MASTER BATH AND GUEST BATHROOM 1© NEW 1/2" GYP BOARD ON INTERIOR WALLS IN UNIT. PROVIDE MOISTURE RESISTANT GYP IN BATHROOMS. ® NEW MASTER AND GUEST BATHROOM LIGHTING WIRING AND SWITCHES NEW SHOWER, SHOWER PAN, z" CEMENT BOARD WALLS, TILE AND ASSOCIATED HARDWARE IN MASTER BATH AND GUEST BATH ® NEW WALL SECTIONS AS SHOWN NEW BATHROOM EXHAUST FANS CONNECT TO EXISTING EXHAUST DUCTS 1Q? NEW DROP CEILING. USE 4" METAL STUDS TAPCONED TO THE UNDERSIDE OF SLAB EXCEPT IN BATHROOMS (SEE DETAIL 1). ADJUST FIRE SPRINKLER HEADS AS REQUIRED (SPRINKLER DESIGN BY OTHERS). ® NEW 1/2" GYP BOARD ON CEILING THRU OUT UNIT 09 NEW 4" LED RECESSED CAN LIGHTING THRU OUT UNIT ® NEW OUTLETS THRU OUR UNIT ® NEW SWITCHES THRU OUT UNIT NEW HVAC UNIT TO MATCH EXISTING. EXISTING DUCT WORK TO REMAIN. ® NEW WINDOW IN EXISTING OPENING. DOOR SCHEDULE 0 Exterior Doors Interior Doors Size Type I 141'X96' Sliding Glass Door 22 69'x96' Sliding Glass Door 33 141'X96' Sliding Glass Door ® 2868 Masonite style H.C, Pocket Door 5 2668 Masonite style KC, © 2068 Masonite style H.C. BI-Fold Door ❑7 1 2468 Masonite style H.C. Bi-Fold Door ® 1 2668 asonite style H,C, BI-Fold Door NOTE: EXISTING HURRICANE SHUTTERS TO REMAIN WINDOW SCHEDULE MARK WINDOW SIZE TYPE REMARKS t 52"02" Singlehung NonIMD02t 2 36"X62" Singlehung NonImpact All windows to have bronze frames, clear glass NOTE: EXISTING HURRICANE SHUTTERS TO REMAIN EXISTING CONCRETE SLAB 2x4 GALVANIZED METAL TRACK 'DRYWALL BOTH SIDES 13 BATT INSULATION METAL STUDS @ 24" O.C. BOARD (TYP.) GALVANIZED TRACK EXISTING CONCRETE SLAB TYP INTERIOR NON LOAD BEARING WALL SECTION 1"=1' SCALE - EXISTING CONCRETE SLAB NEW 1/2" GYP BOARD 1/4" x2-1/4" TAPCON SPACED NEW 4"x20 GAGE STEEL @ 1'-0" O.C. (TYP) STUDS SPACED @ 1'-4" O.C. DETAIL 1 z"=1' SCALE ,,4,SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772) 2 8 5 - 0 5 7 2 BRIAN J. MASKOL. FL PE # 66080 \�\CE F'. * ; No 0 AI z 0 w Q H Q z 0 w a 0 0¢� W WU= (x 0 4 0 0 V � DATE DESIGNED GMW 09-13-20 DRAWN GMW 09- 13-20 CHECKED JOB NO. 2020-300 A=2 ELECTRICA I DI IlN 1/ -T - 1 -4J Jlil'M1L6 NOTE: ONLY NEW ELECTRICAL SHOWN. EXISTING ELECTRICAL NOT SHOWN IS TO REMAIN. REMOVE AND REPLACE ALL EXISTING OUTLETS & SWITCHES IN SAME LOCATION. NOTE: THERE IS NO ADDED ELECTRICAL LOAD TO THE EXISTING SERVICE. €EPD LED CAN LIGHT I iNET FLUORESCENT RXTURE FERN OUTLET Wf'a.IGHT F'A€si WITH NO LIGHT - ' THREE I WAti°'....'.., SWITCH SWfTC W/DIMMER DUPLEX OUTLET 220 V':OUT€.Ei GROUND FAULT INTERRUPTER SMOKE DETFCT0R 'V TELEVIS€ )N NOTE: RECEPTACLES IN KITCHEN & BAI'H AREAS TO BE ' ALL 120V SINGLE', PHASE 15 & 20 AMP BRANCH CIPCUITS SUPPLYING OUTLETS THAT ARE NLLOT GFCI MUST DE AFCI, TAMPER PROOF AECE TICALES MUST BE INSTALLED IN 120 &`GLi, SINGLE PHASE 15 & 20 'AMP BRANCH CIRCUITS GENERAL ELECTRICAL NOTES ALL BEDROOM, FAMILY ROOM, DENS,DINING ROOM LIVING ROOM CLOSETS HALLWAYS CLOSETS CIRCUITS TO BE ON ARC FAULT BREAKERS PROVIDE PHONE AND TV OUTLETS. VERIFY LOCATIONS. RUN HVAC WIRES AS REQUIRED. ALL BATH AND KITCHEN OUTLETS WHERE NOTED TO HAVE GROUND FAULT INTERRUPT SMOKE DETECTORS TO BE HARD WIRED TO MAIN HOUSE WITH BATTERY BACK UP MICROWAVE OUTLETS TO HAVE DEDICATED CIRCUITS PROVIDE LEGIBLE DIRECTORY @ PANEL INDICATING INDIVIDUAL CIRCUITS DO NOT SCALE DRAWNGS REFER TO FLOOR PLAN ALL WORK DONE SHALL COMPLY W/ ALL LOCAL STATE AND NATIONAL CODES vvs SUMMIT DESIGN & FORENSICS, INC. 725 SE PORT SAINT LUCIE BLVD. SUITE 203 PORT SAINT LUCIE FL 34984 (772)285-0572 BRIAN J. MASKOL FL PE # 6( , o6 TATE OF [[/ Jot'•y'sr'��\� ('OR19,, r G\ \\ ONA 1.1\�\\\\ z 0 H a a u w Q Q 0 5 w a �,� 0 O w WU� O o DATE DESIGNED GMW 09-13-20 DRAWN GMW 09-13-20 CHECKED JOB NO. 2020-300 Eml