HomeMy WebLinkAboutCertification for Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Garcia Residence
Project Address:
Permit #: Occupancy Type: Residential Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBC RES Code Sixth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: X I II III IV Exposure Category: B X C D
4. Design Wind Velocity 160 mph ASD LRFD End Zone Width: ft
S. Mean Roof Height 14.67 ft Roof Pitch: 6 :12 Parapet: NA ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 65.3/-71.5 Zone 2: 65.3/-83,.5 Zone 3: 65.3/-83.5 Zone 4: Zone 5: Garage:
7. Design Loads: Floor: 75 PSF Roof/Dead: 15 PSF Roof/Live: 20 Balcony: NA PSF
Dock: NA PSF Deck: NA PSF Stairs: NA PSF Fence: NA PSF Railings: NA PSF
8. Were Shear Walls Considered For Structure? X Yes Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure:1500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces eci i
\� Matthew Lee Gore
Print Name Cert # &-Cyo. Cert Auth.
Date, and Seal Matthew L Gore, Architect 640 Acacia Road Vero Beach, Flori 6 CO
PI
Company Name & Address
Revised 12/07/2018