HomeMy WebLinkAboutProject Informationhi, Project Summary - o. Entire House By. QUICK CALCS,.INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772.46676796 Email: QUICKCALCS@,AOL.COM For: THE GRAND=CARLTON. IMPACT. WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: � � Cx "TZ. Design . • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90. OF Inside db. 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 %. Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central. vent (0 cfm) 0 Btuh (none). (none). Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swingg multipplier 0.95 Infiltration . Equipment sensible load 24753 Btuh Method i simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts .. 2318, Btuh Central: vent (0 cfm) 0 Btuh Heatingg . Coolingg (none) Area (fF) 1446 1446 Equipment latent load 5521 Btuh Volume (ft'). 12511 12511 Airchangesmour 0.45 0.23 Equipment Total Load (Sen+Lat) 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536k030 ' AHRI ref 7914585 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 .cfm . Actual airflow 1160 cfm Air.flowfactor 0.049 dni/Btuh Airflowfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - - �18//'Ii i S�9 ° 2020-Jao-0816:20.47 Rigf¢-Site® Uriversal 201919.0.07 RSU08101 Page 1 ighsoftWACnEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 Front Door faces: N g Right-J® Worksheet �°� Entire House Date:, QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a( AOL.COM 1 Room name Entire House BEDROOM 2 . E)posed vmll 1562 it 49.0 ft 3 Room height . 8.7 ft d 8.0 ft heaftol 4 5 Room dimensions Room area 1445.5 f12 1.0 x 297D ft 297.0 V Ty Construction number U-value (Bh Kd2_°F) Or HTM (BtuhtF) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 - V+/ 13A-4ocs AA5=2om 13A4ocs 0143 " . 0.7-70 0.143 n" .n' a ..4.00 "' 21":56 4.00 255 19.31 2.55 503 ' 38 128 465 0 83 1862 815 333 1184 -730 212 . 72 0 0 72 0 0 '286 :0 0 ` 183 . ---0 0 11 IL_G D 1Ao1om 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W . V�! L-G �✓ V�-G 13A4ocs 13A-4ocs 1A-clom 13X46cs 1A�clom. . 0.143 0.143 1270 . 0.143 1270> . se s s - W w 4.00: 4.00 35.56 4'.00 3556 2.55 2.55 34.77 2.55 5521, - 34, 360 7 310 32 34 353 7 237 2 ' 136. 1414 247 949 1140 86 899 241 603 1170 0 216 0 ' 104 32 0 216 0 72 .2 -: o 865 0 28B 1140 ' 0 550 0 . 183 MO C :4A5-20m 12C-Osw .16A-30md 0.770 0.091 0.032 . w - - 21.56 2.55 .0.90. . 19.31 128 2.32 41. 192 _ 1446 41 192 1446 880 489: 1295 788 246 3354..297 0 0 .6 0 ` 297 0 0 '266 . 0 0 689 P C F 22A t01 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c) AED excursion ' 918 627 Envelope lose/gain 14961 13349 4204 4003 12 a) Infiltrafion 2887 791 848 232 b) Room ventilation, 0 0 0 0 13 Internal gains: Occupants@ 230 6 1360 3 690 Appliances/other 2000 0 Subtotal (lines 6to 13) 17848 17520 5053 4925 Less extemalload 0 0 0 0 Lesstranster 0 0 0 0 Redishibuton 0 0 0 0 14 Subtotal, 17M 17520 •5053 4925 15 Ductloads 32% 49% 5654 8536 320% 49% 1601 2400 Total room load 1 23503 26056 -7] 6653 7325 Air required (dm) 1160 1160 328 326 Calculations approved WACCA to meet all requirements of Manual J 8th'Ed. Ad- 2020-Jarr0816:20:47 Mght-SLite@ Uriversa12019 l9.O.O7 RSU08101ACCk Page 1 ...ightsoftFNAC1THEGRAND CARLTON-1446-1MPACT.nip Calc=MJ8 Front Door faces: N g -`etyrr>Hgti Rightl® Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE; FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a(AOL.COM Job: Data: By: 1 Room name wIC KITCHEN 2 Exposedmall 0 ft 01 ft 3 .Room height 8.0 ft heal/Cool 8D ft heaU000l 4.. Room dimensions 6.0 x 9.0 It 1.0 x 172D It 5 Room area 54.0 T 172.0 ftz Ty . Construction U-value Or HTM Area (tl?) Load Area (ft-) Load number (BWh/ffil°F) (Btuh/ilz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 13AAocs .; 0143 ; n 4.00 2.55 0 0 0. 0 0 0 0 0 G ,4A52om 07-70 :`.n 2156 `,19.31 '0'.' : ' 0... 0 0 .: 0 0 ; :0 -`.0 13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0: ,.: 0 1A-clam 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 V1h. 13AAocs', 0.143 'se.. 4.00 255 0 0 0. 0 0 0 0 0 VIJ �-G 13AAo s 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 134-46 s 0143 w 4:00 2.55 0 0 0 0 0 0 0 0 G AA-clom 1270 w 35.56 5521. 0 0 0 0- 0 0 0 0 4A5-2om:. 0.7,70 w 2156 19:31 0: 0 0 .0 0 0 0' . 0 P 12C-0sw 0.091 2.55 126 0 0 0 0 64 64 163 82 C -. ,. ,. •16A30md 0.032 - - .0.90 2.32 64-1 54 48, 125 .172 ' . 172 154 - :.399 F 22A-tpl 0.989 27.69 0.00 54 0 0 0 172 0 0 0 6 C) AED excursion . -9 -170 Envelopeloss(gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Roomventilation 0 0 0 0 13 Internal gains: Oocupants,@ 230 0 0 0 0 Applianoes/other 0 1 2000 Subtotal (lines 6 to 13) 48 117 .317 2311 Less extemalload 0 0 0 0 Lesstransfer 0 0 0. 0 Redistribution 0 0 0 0 14 _ Subtotal 48 117 317 2311 15 Dudloads 32% 49% 15 57 .32% 49% 100 1126 Total room load 64 174 1 418 3437 Airrequired (dm) 3 8 21 153 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. 2020-Jan-0816:20:47 Right-Sute@ Universal 201919.0.OZ RSU08101 ACM iglisoftWAC\THE GRAND CARLTON-14464MPACT.rp CaIc=MJ8 Frontboor.faws N Page -9- wrightsoft, Right-M Worksheet Job: Entire House Data: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax:772-466-6796 Email: QUICKCALCS(a'DAOL.COM 1 Room name BATH BEDROOM2 2 3 Exposed wall Room height 5.0 ft 342 ft 4. Room dimensions 8.0 ft heat/cool 8.0 ft heat/e0ol 5 Room area 9.0 x 5.0 ft 45.0 iF 1.0 x 203.5 ft 203.5 ftz Ty C,ontr lion U-value Or HTM Area (ftz) Load Area (1F) Load ( Fj (Btuh/tt') or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 G 13A-9ors :4A5-2om 0.143 0:770 n n 4.00. ' 21:56 2.55: 19.31 40 : 40 .0 160 102 128 128 . 513 326. V)/ 13A-4ocs 0.143, - a . 4.00 . 2.55 ; 0 0 0 0 0 0 0 80 0 56 0 - :0 225 0 143 11 I;_O D 1Ac1om 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 24 2 848 2082 W ' ,13Aftons 0:1,43 'se 4.00 2.55 0 0 0 0 0 34 0 0 ' 34 0 136 0 86 VN L-G 13AAocs 0.143 s 4.00 2.55 0 0 0 0 32 32 128 81 1At1om 1270 s 35.56 34.77 0 0 0 0 0 0 0 0 13X-0I s' 0.143 , w, 4.06 2.55 0 0 0 0 0 0 0 0 G 1A-c1om 1270 w 35.66 5521 0 0 0 0 0 0 0 0 4A5 tom 0.770 :. w 21.56 19:31 0. 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 128 0 0 0 0 0 0 0 0 c :.. 16A306id. 0.032 0.90 2.32 . '45 45 40 104 204 204 ' 182 472 F 22A-1pl 0.989 27.69 0.00 45 5 138 0 204 34 . 946 0 6 c) AED excursion -16 -85 Envelope losslgain 339 190 2978 3106 12 a)' Infiltration 87 24 593 162 b) Room ventilation 0 0 01 0 13 Internal gains. Ooarpants@ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 . 3498 Less external load 0 0 0 0 Lesstransfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Ductloads 32% 49% 135 104 32% 49%1 1131 1704 F1Total room load 560 318 4702 5203. Air*uired(cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A" ��9� oTt" 2020-Jan-081620:47 " "" Rigid -Suite@ Universal 201910.0.07 RSU08101 Page 3 Igl1softHVACITHEGRAND CARLTON-1446=1MPACT.rLp Calc=MJ8 FrontDoorfaces: N ALI wrightsoft° Right'J® Worksheet Job: Entire House Date: QUICK CALLS, INC. ey. 317 ST.. LUCIE LN., Ft. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING wall h 6.0 ft 47.0 ft 3 height Room 8.0 ft heaU000l 92 ft heaV000l 4.. Room dimensions 7.0 x 6.0 ft 1.0 x 526.0 It 5 Room area 42.0 fF 526.0 fF Ty Construction U-value Or HTM Area Load number (Bhh1-°F) (Btuh/tF) or perimeter (ft) (Bh) or perimeter (ft) (B h) Heat Cool Gross NIPS Heat Cool Gross N/P/S Heat Cool 6 -13A�togS 0143 : n " 4.00 - 2.55 : 0 ... 0 0- 0 255 , 217 '869 A4 20m-. : 0770 " h" . " 2156, '19. 1 " : 0 : 0 0 0 38 0 ,815 :. 730 0143 a 4.00 2.55 0 0 0 0 0 0 0 0. L13A4ors 1Ac1om 1270 a 35.56 8729 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 1N: :13A4as 0.143 -se 4.00 `2.55 0 0 0 0 0 0 .0 0 t13A4ocs 0.143 s 4.00 2.55 48 48 192 122 0 0 0 0 -G 1Aclom 1270 S 35.56 34.77 0 0 0 0 0 0 0 0 0143 ; w 4.00 2 55 0 0 0 0 206 165 MI 420 �13AAocs G ' 1Ac1om 1270 . w 35.56 6521 0: 0 0 0. -. 0 • 0 0 0 4A5 tom . 0.770 w 21.66 10.31. 0, 0 '0 .0 41 41 880 788 P. 12C-Osw ' 0.091 - 2.55 128 56 56 143 72 0 0 0 0 C :,. : 16A-36md 0.032 - :: 0:90 '2.32 42' 42 38 97 b26 526 - 47:1 1. 220 F 22A tbnl 0.989 27.69 0.00 42 6 166 0 526 47 1302 0 6 c) AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Oocupants@ 230 0 0 2 460 Applianoes/other 61 0 Subtotal (lines 6 to 13) 643 298 5994. 5112 Less exlemal load 0 0 0 0 Less transfer 0 0 .0 0 Redistribution 0 0 0 0 14 Subtotal 643 -298 5994 5112 15 Ductloads 32% 49% 204 145 320% 490 1899 2490 Total room load 846 443 7892 7602 Air required (dm) 42 20 390 338 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - vvNghott^ Rigtrt-Sute®Uriversai 201919.0.07 RSU08101 2020-Jan 081620:47Page 4 igMoftHVAC1THEGRAND CARLTON-14464MPACT.nQ Calc=WB Front Doorfaoes: N *wrygh1WA) ° Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM 1 Room name FOYER M BATH hI 7 .0 ft 8.0 ft 3 Room height t 8.0 ft heat/cool 8.0 ft heat/000l 4. Room dimensions 1.0 x 60.0 ft 7.0 x 8.0 ft 5 Room area, 50.0 ftz 56.0 T Ty Conir cdon U-value Or HTM Area (ftz) Load Area (ilz) Load number ( F) (Btuh/Itz) or perimeter (ft) (Btuh) or perimeter M (Btuh) Heat Cool Gross N/P/S Heat Cool Gross IMPS Heat Cool 6 .yl. . ' 13A flocs 0.143 . n 4:00 2.55 .8 8 32 20 0 0 0 0. �-G AA5.2om 0.770 n 21.56 . - 19:31 0 0 - 0 .0 0 U 0 . 0 13A4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 IA-clom 1270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 D 1100 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 w 13A4ocs 0.143 se 4.00 2.55 0 0. 0 0 0 0 0 0 y/ 13AAocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 146 Y-G 1A-c1om 1270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-4ocs . 0.143 , w 4.06 2.55 0 0 0 0 0 0 6 0 GAA-'Iom 1270 w 35.56 55.21 01. 0 0 0 0 6 0 0 i4A5-2om 0.770 w 21.56 . 19.31 0. 0 0 0 0 0 0 0 p 12C-Osw 0.091 2.55 1.28 72 72 183 92 0 0 0 0 C -16A30md 0.032. - 0.90 2.32 50 50 45 116 56 56 '50 F 22A-tpl 0.989 27.69 0.00 50 7 194 0 56 8 222 .136 0 6 c) AED excursion 39 38 Envelope lossIgain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances(other 0 1 0 Subtotal (lines 6 to 13) 913 529 885. 516 Lessextemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Dud loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (dm) 59 35 58 34 Calculabonsapproved byACCAto meet all requirements of Manual J 8th Ed. 44d- w1r3gl vMCw1� 2020-Jai-08162047 RigMkStite@)Uriversal 20l9 l9.0.07 RSU08101 ...igttsoftWAOTHEGRAND CARLTON-1446-IMPACT.rp Calc=MJ8 Front Door faces: N Page wnghtsoft° Dluct System Summary o te. Entire House By - QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-46.6-6799 Fax 772-466-6796. Email: QUICKCALCS@AOL-.COM For: THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE, FL Heating Cooling Extemal.staticpressure 0:50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.static pressure 0.50. in H2O 0.50 in H2O Supply/.retum available pressure 0.250 /0.250 in H2O 0.250 /0.250 in H2O Lowest friction rate 0.285' in/100ft 0.285 in/100ft Actual airflow 1160 cfm 1160 cim Total effective length (TEL) 176 ft Name Design (Btuh) Htg Orn) Clg (Cfm) Design. FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx . 22.4 115.0 st1 BEDROOM2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM•B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 sit FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREAVDINING h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 GREATIDINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 KFTCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design, Veloc Diam H x W Duct Name Type (cfm) (cirri) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 0.285 918 12.0 0 x 0 VinlFIX st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx 40- wrightsoft® 2020-Jan-081620:48 oartetvevuex.wro®eyw Rigl tSLite@ Uriversal 20l9 l9.0.07 RSUD8101 Page 1 igttsoffWAC1THEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 FrorrtDoor faces: N' Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfrn) . TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mal. Trunk rb1 OxO 1160 1160 0 0 0 0. Ox 0 MFx 411- wrightsoft® 2020-Jar}0816:20:48 ti AWVk•l6�Abhu.kmvyfamgy Right-SUM)Uriverse] 20,1919.0.07 RSU08101. Page t A...igtisoftWAC\THEGRAND CARLTON-1446-IMPACT.np CaIc=W8 Frorft Door faces: N