Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
f A=LIFE SAFETY WARNING 40 This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE ALL TRUSSES ARE TO BE SET AT 2'-O: ON CENTER EXCEPT AS NOTED L-- MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE IF MULTIPLE PLY. DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span'or less A 30' to 60' Span A 6o degrees Spreader Bar or less _ 09 �— Appro 1x 2/3 to Une 1/2 of Span Tag Line span approx. REFER TO BCSI REFER way BCSI Truss must be set this way if crane used Truss must be set this way if crane used. Truss is on .x.Mple; your truss moy not notch This. is an example, truss may not match. Insist crone operator. sets truss this .way.Insist crane operator sets truss this way. 5 t t a ar; _ U REPRESENTS A HANGER „ Carrying Girder j, For Truss to Truss Connections see hanger/connectorTNaltsbeas de tabs o schedule in engineeringe nails. `. package. s Carried Truss SEAT PLATES BY CHAMBERS INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR 12 4.00 M LID I upset=1/4" heel=315/16" PLUMB CUT END 1 2 x 4 Top Chord WALL HEIGHT 8'-1" TYPICAL END DETAIL 12 4.00 F— iD 8 1, `O 12 2.00 „ upset=1/4" heel=315/16" PLUMB CUT END .r 1 2 x 4 Top Chord r WALL HEIGHT 8'-1" END DETAIL: A ., 4 ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 17'- 23'IN L=-NGTrm & Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers GARAGE LEFT FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the trusses will be Installed Is; - The iir emlgned acknowledges and agrees: 1. Trusses will be made In strict accordance with this Wss placement dlagrem layout, which 13 the sole authority for determining.sueceasful fabriCaton of the trusses, 2,AI1 dimensions h this layout have bean vedfted by the undersigned. .3. Unless written no'co b provided by aerti8ed mall to Chambers Truss V' 'In ten (10) days of delivery the undenagnad agrees that no backchan;es will ba ello% cl,.ln the event such written notice la Pom0, to Chambers Truss shelothec l have three f3) business days In which to4.The uin ndersignairs ed acknowledges receipt of BCSI 1-0 lQuammery bers heat by'fPl & VJTCA. 6, Delivery b to Job rite. It is the buyer•s'respenslbllity, to make the lob site suitable for delhrery, Chambere Truss has the sole authority to determine the sultabllily of the Job site or a portion of the Job she for delivery, Chambers Truss will be responsible for dump delivery only, The buyer Is responsible for additional delivery expenses If Chambers Truss has to redeliver because Job she Is not prepared for delivery or buyer Ia not prepared for delivery of trusses. Buyer is responsible to Chambers Truss for towing Posts due to site conditions, 8. Price as shown Iq paragraph 7 below Is subject to change If any changes are, made In this, layout A $50 per hour fee for revisions may be charged by Chambers Trues, 7. This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, ar If nq'; agreement a reasonable price. Invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of. delivery If buyer cannot swept delivery of fabricated trusses. The undersigned agrees to pay Chambers. Truss reasonable attomey's fee for collections In event of payment not timely made. .1-I 2 % per month service change will be added for all sums not paidwithinterms. 8. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. Q. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Truss by. any entity receiving material and the undersigned agrees to pay such Indebtedness Including attomays fees, If default In payment for material be made by the recipient. . 10. In the event of any iltigation concerning this agreement, the Items furnished hereunder or payments referred to herein, the, parties agree that the We venue for any such action will be Saint 60cle County, Florida.. 11. Design responsibilities are per "National Standard AndRbtammended Guidelines On Responciblll8es For Construction Using Metal Plate Connected Wood Trusses ANSI(rPI NrrCA 4 - 2002" . DATEp SIGNED FOR TITLE Aspreaderbar maybe recR!md por'E(SI I-W'ty prumnt Injury & damage. Multiple ply trusses must be fastened togethar per engineering before they are set; failure to do so can result In roof collapse, temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses. Trusses must be aetand braced pardesign to pravord irijury & damage, Trusses must be set plumb and square Do not set bunks or stack of plywood, roofing material of any other concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC 3105 Oleander Avenue Fort Pierce; Florida 34982-6423 800-551-5932 Fort Pierce 772-M-2012 Fax 771-465-8711 Vero Beach 772-569-2012 Stuart 772-286-3302 ' The Architect's or Architect's representative's shop drawing approval is NOT, aj - - "double check" of the contrac b . The contractor shell remain respofinsible for checking. field measurements and other construction criteria. Architect-s approval covers general roof shape, review of truss strapping, and load,n on structure from. gravity and uplift loads and their r ective,locati s. ' Approved By Date. I Braden & arafen A.I.A. P.A. 1I 92.0/93.2 MITEK 4.2 DESIGN CRITERIA - County SAINT LUCIE Building Department SAINT LUCIE COUNTY Wind Design Criteria ASCE 7-2010 ., i3 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 h Roofing Material Shingle or Shake N Loading in PSF Roof R.D.L., H c Top Chord Live 20 Top Chord Dead 7 4.2 FIEj QtLChord Live 10 Non -Concurrent 06E ord Dead 10 3 J37 ;T a '1 eke �It FT1ctor 1.25 7.2 " ind Speed 165mph ^ ,,;�PY r N To Chord C.B. Sheetinfpl Bottom Chord C.B. Sheeting by builder. U �„ Highest Mean Height 14'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 K.D.L. Restraining Dead Load G.B.=Continuous Bracin Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Building Desi ner and/or Engineer of Record. Chambers Truss Inc. Drawing Name: Ml1323 L1J Scale: 1 /4 = 1' C 72 total trusses, 13 different trusses. MI 4: SAE ACAD: SAE Reviewed By: UN Date:04/24/12 Revised:02/21/18 FOR Revised: 3/05/2020 3' 4" WYNNE BUILDING CORP. ' ----- — — ' DESCRIPTION: GARAGE RIGHT CARLTON PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M 11323 '7-7®5.5 �z MiTeke RE: M11323 MiTek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T19884596 A 10/9/2020 2 T19884597 A5 10/9/2020 3 T19884598 A6 10/9/2020 4 T19884599 A7 10/9/2020 5 T19884600 A8 10/9/2020 6 T19884601 A9 10/9/2020 7 T19884602 GRA 10/9/2020 8 T19884603 GRB 10/9/2020 9 T19884604 J2 10/9/2020 10 T19884605 J4 10/9/2020 11 T19884606 J6 10/9/2020 12 T19884607 J8 10/9/2020 13 T19884608 KJ8 10/9/2020 This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,`���� based on the parameters provided by Chambers Truss. ,,��OP,QUI N Vp, Truss Design Engineer's Name: Velez, Joaquin �� �c E NB�,.� My license renewal date for the state of Florida is February 28, 2021. Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/rPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSIITPI 1, Chapter 2. :9 STATE OF : 44/ �Z iO 4(/Al 11111 Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 October 09, 2020 1 of 1 Velez, Joaquin Job Truss Truss Type City Ply T19884596 M11323 A COMMON 9 1 �1011323 ' Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1 ID:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_l Hpv5SDpc_pEKrtnVLQuvtwTtLrJWzUUjw -0 6-7-13 12 4-13 17-0-0 21-7-3 274-3 340-0 0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 -0-0 Scale=1:57.8 3x6 = 4.00 12 4x5 = 27 17 '" 15 "" "' 14 '" 12 2x3 II 4x6 = 3x8 = 3x8 = 4x8 = 2x3 II 3x6 = 6-7-13 12-4-13 21-7-3 27-4-3 34-0-0 6-7-13 5-9-0 9-2-7 5-9-0 6-7-13 Plate Offsets (X,Y)— [2:0-0-2,Edgel, [10:0-0-2,Edge) LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.32 14-15 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.61 14-15 >670 240 BCLL 0.0 Rep Stress Incr YES WB 0.65 Horz(CT) 0.12 10 n/a n/a BCDL 10.0 Code FBC2017(rP12014 Matrix -MS Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10). 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=3419/2395, 3-5=2771/2031, 5-6=-2770/2152, 6-7=-2770/2152, 7-9=-2771/2031, 9-10=3419/2395 BOT CHORD 2-17=21132/3213, 15-17=-2132/3213, 14-15=-1269/2000, 12-14=-2132/3213, 10-12=-2132/3213 WEBS 6-14=-635/983, 7-14=-313/362, 9-14=-689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-0-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members, with BCDL = 10.0psf. electronically signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) sealed by Velez, Joaquin, PE 2=832,10=832. using a Digital Signature. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at Printed copies of this 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and sealed and the signature must be verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Joaquin Velez PE No.68182 Vert: 1-6=-54, 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cent 6834 Concentrated Loads (lb) 6904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1,1II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply M11323 T19884597 M11323 A5 SPECIAL 9 1 ' Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScuwvyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzUUjv 1-0-0 7-8-5 10-0 4 17-0-0 20-4-8 26-4-0 34-0-0 _ _ _a5 0 Q -0-0 7-8-5 2-9-15 6-5-12 3-4-8 5-11-8 7, -0-0 a' 5x6 MT18HS 11 4.00 12 Scale=1:59.8 13 12 3x12 2.00 12 5x12 = 2x3 II 3x6 = = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=-803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) CSI. DEFL, in (loc) I/deft L/d PLATES GRIP TC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 Be 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 WB 0.60 Horz(CT) 0.36 10 n/a n/a Matrix -MS Weight: 155 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 1 Row at midpt 6-14 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5529/3776, 3-5=-5164/3538, 5-6=-5209/3667, 6-7=-2424/1902, 7-9=-2462/1813, 9-10=-3195/2210 BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=-2175/3326, 6-13=-279/534, 7-13=-237/277, 9-13=-786/560,9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2.4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Extefior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb) 2=803,10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Padre East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall �1A� building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP11 quality Criteria, DSB-89 and Bost Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884598 M11323 A6 SPECIAL 1 1 Job Reference (optional) C?Iambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 I D:2GIScwwyY5hnG hXVARzUkuyu FU M-YYr6a4B_W eYX90cbw00 HJ Ix7ilyPMm6DxB gy00zUUju n1-0-0, 8-11-11 16-0-0 18-0-0 20-4-8 25-11-15 34-0-0 $5-04 0-0 8-11-11 7-0-5 2-M 2-4-8 5-7-7 8-0-1 1-0-0 4.00 12 �P 3x12 = 2.00 12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017rrP12014 LUMBER - TOP CHORD 2x4 SP M 30 *Except* 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10). 9=-803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) 6x10 MT18HS = 5x6 = 5x6 = 3x6 = Scale = 1:61.9 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 BC 0.93 Vert(CT)-0.9214-17 >443 240 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 9 n/a n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=2314/1551, 6-8=-2398/1533, 8-9=-3199/1981 BOT CHORD 2-14=-3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=-1731/3001, 9-11=-1731/3001 WEBS 4-14=492/513, 5-14=-1707/2959, 5-13=405/196, 6-13=-179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 24-13 to 31-7-3, Extedor(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803, 9=803. I jT This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall p .� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Truss Truss Type City,Ply M11323T19884599 ;�� A7 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID: WSJgpGwal Ppeur6hk9Uj G5yu FUL-0I PUnOCcHygOmYBnU kXW ryTI Fi I45CtN9gaVwrcUUjt 1-0-0 8-10-10 14-0-0 20-0 0 25-11-15 34-0-0 5-0 0-0 8-10-10 5-1 6 6 0-0 5-11-15 8-0-1 -0-0 Scale = 1:60.8 4 nn 5x8 = Sx6 = t•l•1• 3x12 = 2.00 12 5x12 = 2x3 II 3x6 = 10-6-4 14-0-0 20-4-8 2511-15 34-0-0 10-6-4i .1 3-5-12 6 4-8 5-7-7 8-0-1 Plate Offsets (X,Y)— [2:0-1-15,Edge] [4:0-4-0,0-2-3], [7:0-0-2,Edge] LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.90 Vert(CT) -1.10 10-11 >369 240 MT18HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.34 7 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 147 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. WEBS 2x4 SP No.3 *Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Harz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=-803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5484/3370, 3-4=-5116/3126, 4-5=-2229/1544, 5-6=2448/1599, 6-7=-3169/1993 BOT CHORD 2-11=-3071/5219, 10-11 =-1 590/2874, 9-1 0=-1 738/2968, 7-9=-1738/2968 WEBS 3-11=-419/443, 4-11=-1466/2647, 4-10=-812/448, 5-10=-205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-M zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically Signed and 7) Bearing at joint(s) 2 considers parallel to grain value using ANSIfrPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) using a Digital Signature. 2=803, 7=803. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 8904 Parke East Blvd. Tampa FL 33610 Date; April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 1,1II-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safetyinformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty PlyTJMob 1323 T19884600 M11323 AB SPECIAL 1 ' Reference (optional) mbers truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 ID: W SJgp GwalPpeu r6hk9UjG5yuFUL-Uxzs_mC E2FoFOiI_2 R210AOT6 eKgj E W OUJ2SHzU Ujs 1-0-0 8-8-4 12-0-0 15-8-4 2048 22-0-0 24-8-12 34-0-0 -MOO -0-0 8-8-4 3 3-12 3-8.4 4.8-0 1-7-8 2-8-12 9-3 4 0-0 �1 6 5x6 = 4.00 12 3x4 = 2x3 II 5x8 = 21 5 6 22 7 12 11 5x12 = 3x4 = 4x5 = 3x12 = 2.00 12 10-6.4 Scale = 1:60.6 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.78 BC 0.90 WB 0.69 Matrix -MS DEFL. in (loc) I/deft Ud Vert(LL) 0.65 12-13 >624 360 Vert(CT) -1.08 12-13 >379 240 Horz(CT) 0.33 9 n/a n/a PLATES MT20 MT18HS Weight: 154 lb GRIP 244/190 244/190 FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural woad sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=-803(LC 10) Max Grav 2=1312(LC 1),9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=5488/3444, 3-4=-5117/3183, 4-5=-3911/2497, 5.6=-2576/1770, 6-7=-2586/1779, 7-8=-2663/1762, 8-9=-3021/1971 BOT CHORD 2-13=-3143/5224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11 =-1 705/2827 WEBS 3-13=-396/420, 4-13=-1 028/1721, 5-13=-300/797,5-12=-894/601, 6-12=-265/263, 7-12=-294/391, 7-11=-374/691, 8-11=-535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members. electronically signed and 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE rapacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt=lb) using a Digital Signature. 2=803, 9=803. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68181 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not Nat a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Inforrnadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply M11323 T19884601 M11323 A9 HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1 ID:_etC1 cxC3ixVV?huts?ypJyuFUK-y7XEC6DspZw6OsKAc9Z_xNZ18W4CZ7Mfd83c7zUUjr 1-0-0 6-7-15 10-0-0 15-2-74 20-4-0 24-0-0 27-4-1 34-0-0 5-0- -0-0 6-7-15 3-4-1 5-2-14 5 1-2 342 3 4-1 6-7-15 -0-0 4.00 12 4x4 = 3x4 = 20 II 4x8 = 4 24 525 26 6 27 7 14 1L Scale = 1:58.6 3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5 20-4-0 24-0-0 34-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.35 BC 0.54 WB 0.89 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (too) I/deft Lid -0.18 11-21 >917 360 -0.38 11-21 >432 240 0.02 13 n/a n/a PLATES GRIP MT20 244/190 Weight: 156 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 Do bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10). 9=-249(LC 10), 13=-928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=1275/1025, 34=-913/708, 4-5=-829/705, 5-6=-565/807, 6-7=-565/807, 7-8=-104/278, 8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=256/348, 9-11=-124/304 WEBS 3-15=-425/501, 5-15=-444/665, 5-13=-1215/1079, 6-13=-264/300, 7-11=-255/396, 8-11=461/521,7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2.4-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(l) 14-9-11 to 19-2-5, Exterior(2)19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically signed and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Ot=lb) sealed by Velez, Joaquin, PE 2=430, 9=249,13=928. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68162 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Vedfy deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 1 I D:_etC1 cxC3ixVV?huts?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq 1-0-0 8-0-0 11-1-1 17-0-0 18-6-0 22-2-2 26-0-0 34-0-0 5-0- -0-0 8-0-0 3-1-1 5 10-15 1-6-0 3 8-2 3-9-14 8-0-0 -" �1 6 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = Scale=1:60.6 3x5 — 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSIrrPI 1. LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.20 24-35 >914 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) -0.24 29-32 >552 240 BCLL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.02 22 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-351(LC 8), 27=-1168(LC 8), 26=1495(LC 8), 22=-625(LC 8) Max Grav All reactions 250 lb or less atjoint(s) except 2=487(LC 17), 27=2232(LC 13). 26=2929(LC 14), 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280, 20-21=-2230/1280, 21-22=-2271/1263, 6-9=-126/305, 9-11 =-1 06/363, 11-14=-193/412, 14-17=-94/271, 19-21=-143/272 BOT CHORD 2-29=247/677, 27-29=189/540, 26-27=-779/446, 24-26=-411/653, 22-24=-1083/2108 WEBS 3-29=-500/1176, 3-27=1766/911, 5-27=748/622, 5-26=-546/351, 13-26=-946/617, 18-26=-2412/1474, 18-24=-846/1780, 21-24=-35/351, 4-5=-608/514, 19-20=-335/305, 14-15=-556/407, 11-12=-254/54 N N 3 � IT 0 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. This item has been II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) Provide adequate drainage to prevent water ponding. Sealed by Velez, Joaquin, PE 4) All plates are 2x3 MT20 unless otherwise indicated. using a Digital Signature. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • Printed copies of this 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. document are not considered 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at signed and sealed and the joint 27, 1496 lb uplift at joint 26 and 625 lb uplift at joint 22. signature must be verified 8) Girder carries hip end with 8-0-0 end setback. 9) Graphical purlin representation does not depict the size or the orientation of the puriin along the top and/or bottom chord. on any electronic copies. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the 6904 Parke East Blvd. Tampa FL 33610 responsibility of others. Date: 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). April 3,2020 andard ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall MiTek' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing INIiTek♦ is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLTP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) L,namoers I russ, Inc., ron Tierce, t-L 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 ID:_etC1 cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead +.Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 21-23=-54, 29-30=-20, 24-29=-47(F=-27), 24-33=-20, 3-11=-126(F=-72), 11-21 =-1 26(F=-72) Concentrated Loads (Ib) Vert: 29=-641(F) 24=-641(F) ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not ��AA a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek♦ is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB•89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type oty Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference (optional) I lenN '. r ..' nlc., rurl rlerce, rL t1.Z4U S Mar B ZUZU MI I eK Industries, Inc. rn Apr 3 U/:b4:34 ZUZU 8-M 15-8-0 3-4-0 13-0-0 5.8-0 5x12 MT18HS = 4x10 = 5x12 MT18HS = 4.00 12 2x3 II 4x6 = 2x3 II 3 23 4 5 6 7 24 6 Scale = 1:58.6 10 1Z 4x6 — 3x6 II 5x6 = 6x12 = 6x12 = 5x6 — 3x6 II 4x6 13-8-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/TP12014 cSl. TC 0.80 BC 0.68 WB 0.90 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) Well Ud 0.22 16-19 >999 360 -0.30 16-19 >820 240 0.06 9 n/a n/a PLATES MT20 MT18HS Weight: 153 lb GRIP 244/190 244/190 FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-14 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-3-14 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 3-14, 8-13, 6-13 4-14,7-13: 2x6 SP No.2 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Harz 2=90(LC 7) Max Uplift 2=-853(LC 8), 13=-2590(LC 8), 9=345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 34=-2080/1236, 4-6=-2080/1236, 6-7=-1296/2589, 7-8=-1296/2589, 8-9=-751 /370 BOT CHORD 2-16=-1729/3460,14-16=-1753/3525,11-13=-2621733,9-11=-241/668 WEBS 3-16=435/1209, 3-14=-1552/774, 4-14=837/691, 7-13=-878/713, 8-13=-3635/1919, 8-11=-432/1204,6-14=-145312814,6-13=-3198/1807 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at sealed by Velez, Joaquin, PE joint 13 and 345 lb uplift at joint 9. using a Digital Signature. 8) Girder Carries hip end with 8-0-0 end setback. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 Ib down and 461 lb up at Printed copies of this 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the document are not considered responsibility of others. signed and sealed and the 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Signature must be Verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Joaquin Velez PE No.68182 Uniform Loads (plf) MiTek USA, Inc. FL Cert 6634 Vert: 1-3=-54, 3-8=-131(F=-77), 8-10=-54, 16-17=-20, 11-16=-49(F=-29), 11-20=-20 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ing ®WARNING -Verify design parameters and RFJtO NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not �• a truss system. Before use, the building designer must verify the applicability of design parametersand propedy incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOWIs always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply 23 7G'RIS3' T19884603 M11323 HIP 1 1 F.Reference (optional) s r rws, uic., ron nerce, rL LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641(F) 11=-641(F) t1.Z4U s Mar 9 ZUZU MiTeK Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 I D:SrRaEyyrg04M78G4raW BLW yuFUJ-MiCNg7G16U IgtJ31 H H 7hYOB9Sj3emSr6J6HGb2zU Ujo A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �e building design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing Mire k♦ Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSgiP11 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 206011 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884604 M11323 J2 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, inc., Fort Pierce, FL 1-0-0 3x4 = 8.240 s Mar 9 2020 MTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:xl?zSlzTbJCDIIrGPH 1 QukyuFUI-MiCNg7G16UIgtJ31HH7hYOBJ71CDmgz6J6HGb2zUUjo 2-0-0 Scale =1:7.8 2-0-0 LOADING (psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 file nla BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc pudins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=-28(LC 10), 2=-136(LC 10). 4=-3(LC 7) Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. It: Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) zone;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design Into the overall HKe building design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MI'fek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPH Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884605 M11323 J4 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz7ZfRxyuFUH-gvml2TGNtoQXUTexrtew5DjQW7UmV7DFYm1 p8UzUUjn -1-0-0 4-0-0 1-0-0 4-0-0 Scale=1:11.1 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 14 lb FT = 0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=161(LC 10), 4=-7(LC 10) Max Gray 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 Ill uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall pp ��9T�• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IYI� 1pk• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLTP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 267D Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type City Ply M11323 ]Truss T19884606 M11323 J6 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL -1-0-0 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Scale = 1:14.6 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10), 2=-194(LC 10), 4=-B(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. Il; Exp C; Encl., GCpi=0.18: MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply M11323 T19884607 M11323 J8 MONO TRUSS �Qty 20 1 Job Reference (optional) CnamberS Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Page 1 I D:tP6jtz_j7xSx_c_fXi4uz9yu FUG-J5K7FpH7d5YO6dD8Oi99eRGYgXq uEaTPmQm NgxzU Ujm 1-0-0 8-0-0 1-0-0 8-0-0 Scale = 1:17.4 3x5 = 8-0-0 8-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=-228(LC 10), 4=15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2.4-13 to 3-1-13, Extedor(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 69D4 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not �- a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPI1 Quality Criteria, DSB-89 and SCSI Building Component Sa/ety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job russ Truss Type Qty Ply M11323 JKJ8 T19884608 M11323 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 I D:Log54J?LuEancmZr4Qb7 WMyuFU F-n Hu V T9ldOPgFknoKyPgOAeooawBGzwZY?4 WwCNzUUjI 1-5 0 7-3-4 11-3-0 1 5 0 7-3-4 3-11-12 3x4 = �J Scale = 1:20.3 3x4 = 7-3-4 11-3-0 7-3-4 3-11-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (too) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=305(LC 8), 6=-286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=-687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=-1236/755 PLATES GRIP MT20 244/190 Weight: 44 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 cc pudins. BOT CHORD Rigid ceiling directly applied or 8-9-6 cc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE Vert: 1-s Trapezoidal Load(pl f using a Digital Signature. Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=-49), 8=0(F=10, B=10)-to-5=-56(F=-18, B=-18) Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert $634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall �a building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS87P11 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y 4 offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See BCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For 016 c1-2 c2-3 wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I WEBS 4 ❑ V °° �,� H a ❑ _ 3 �� p bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. C) �06 2 0- U 4. Provide copies of this truss design to the building O n ~ designer, erection supervisor, property owner and For 4 x 2 orientation, locate c�-6 c6-7 c5-6 all other interested parties. plates 0- Vid' from outside P BOTTOM CHORDS 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBEREDILETTERED CLOCKWISE locations are regulated by ANSIrrPI 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7, Design assumes trusses will be suitably protected from connector plates. THE LEFT. the environment in accord with ANSI/rPI 1. "Plate location details available In MITek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. 9. Unless expressly noted, this design is not applicable for PLATE SIZE PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. [CC -ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to .4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions the length parallel to slots. indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless Otherwise shown. 13. Top chords must be sheathed or puriins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. section 6.3 These truss designs rely on lumber values BEARING established by others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports) occur. Icons vary but reaction section indicates joint © 2012 MITek® All Rights Reserved 17. Install and load vertically unless indicated otherwise. _ _ number where bearings occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards' im I 19. Review all portions of this design (front, back, words ANSI/TP11: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSIfrPI 1 Quality Criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MITek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 or other loads other than those expressly stated.