HomeMy WebLinkAboutAPPROVED Merged Current - Extreme-Cover Sheet FL 20378.6-R1-5V Crimp 2/13/2018 Florida Building Code Online
RegulationBusiness & Professional
BCIS Home I Log In I User Registration I Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search
Florida
r Product Approval
IUSER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
OFFICE OF THE FL# FL20378-RI
SECRETARY
Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo.com
Authorized Signature Richard McKuhen
flvalidation@yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed the LOCKE BOWDEN
Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
Validation Checklist- Hardcopy Received
Certificate of Independence FL20378_Ri_COI_FL 20378.1 NAILSTRIP 1.0_.032 ALUM_sss.pdf
Referenced Standard and Year(of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA°/o3d%3d 1/4
2/13/2018 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017
Date Pending FBC Approval 10/17/2017
Date Approved 12/19/2017
Summary of Products
FL# Model,Number or Name Description
20378.1 01 -"1" Nailstrip" 0.032"Aluminum Standing Seam roof panel, 12"wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI_II_FL 20378.1 NAILSTRIP 1.0_.032
Approved for use outside HVHZ:Yes ALUM_sss.pdf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_R1_A_E_FL 20378.1 NAILSTRIP 1.0 .032
instructions. ALUM_sss.pdf
Created by Independent Third Party: Yes
20378.2 02-"1"Nailstrip" 26-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_Rl_II_FL 20378.2 Extreme Metal Fabricators_26GA
Approved for use outside HVHZ:Yes NAIL STRIP 1.0.pdf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_RI_A_E_FL 20378.2 Extreme Metal Fabricators_
instructions. 26GA NAIL STRIP 1.0.pdf
Created by Independent Third Party: Yes
20378.3 03-"1.75 Snap Lock" 0.032"Aluminum Standing Seam roof panel, 18"wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI_II_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.4 04-"1.75"Snap Lock" 24-gauge Steel Standing Seam roof panel, 18"wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_Rl_II_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_RI_AE_FL 20378.4_1.75 SNAP LOCK 24GA-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.5 05- "Rib Panel" 29-gauge Steel exposed fastener roof panel, 36"wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI_II_FL 20378.5 RIB 29GA df_ssr.p
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.5 RIB 29GA_ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA°/o3d%3d 2/4
2/13/2018 Flon Building Code Online
20378.6 06-"5V Crimp" 26-gauge Steel exposed fastener roof panel, 24"wide,
mechanically attached to 15/32" Plywood or Wood Deck
w/fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.6_5V Crimp_sss.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Method 1 and Method 2 FL20378_Rl_AE_FL 20378.6_5V Crimp_sss.pdf
fastening. Limitations and Conditions of Use. Refer to Created by Independent Third Party: Yes
manufacturer's installation instructions.
20378.7 07-"1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16"wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips,fasteners and adhesive
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI_II_FL 20378.7 JM STANDING SEAM_ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.7 JM STANDING SEAM_ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.8 08-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
15/32" plywood or Wood Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_RI_II_FL 20378.8_NORDMAN TILE 24GA_ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_RI_AE_FL 20378.8_NORDMAN TILE 24GA_ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.9 09-"Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to
Steel Deck with fasteners
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_R1_II_FL 20378.9 Nordman Tile Details-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E.
Impact Resistant: No #31242
Design Pressure: +N/A/-Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378_Rl_AE_FL 20378.9 Nordman Tile Details-ssr.pdf
instructions. Created by Independent Third Party: Yes
20378.10 10-"Nordman Tile" 0.032"Aluminum metal roof tile panel mechanically attached
to 15/32"plywood or Wood Deck with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378_Ri_II_FL 20378.10 NORD TILT.032 ALUM-ssr.pdf
Approved for use outside HVHZ:Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/-Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FL20378_R1_AE_FL 20378.10 NORD TILT.032 ALUM-ssr.pdf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section
455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have
one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal
address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,
please click here.
Product Approval Accepts:
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqua%2fIMZ8n5CNV4ZYkew5Zoa%2fE%2fovztglbhDVU2dJO4TAA°/o3d%3d 3/4
Product Report Manufacturer: Extreme Metal Fabricators, LLC.
2160 SW Poma Drive
Palm City, FL 34990
772) 872-8034
Compliant with Florida Buiming Code 2017 (611 ed.)
Compliant with Florida Product Approval Rule #61G20-3
Compliant : Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3
Yield strength:40ksi Steel Attached to min. 15/32" plywood or Wood Deck w/ min.
Attached 24" 0.42 specific gravity with screws. 24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506, 1507
Fastener for Method 1 Attachment # 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16" thru wood decking
Fastener for Method 2 Attachment # 9-15 x 1" Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16"thru 15/32"min. plywood deck or 5/8" into wood plank
Underlayment: To be compliant with FBC Sec.1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT
DESIGN PRESSURE* -85 PSF -114.25 PSF METHOD 11N R19 PEAKS
ROW SPACING 12"O.C. 12"O.C. METHOD 2IN PANEL FLATS
FASTENER SPACING 12" O.C. 12"O.C. *SEE INSTALL DRAWINGS
FASTENER SIZE: #9 #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1
Reference Data: HURRICANE TEST LAB #TST ID: 1527
TAS 12S-03 Test# 0223-0307-01;METHOD 1 (UL 1897-041)
TAS-125-03 Test # 0223-0517-06,METHOD 2
EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD * DESIGN PRESSURE SAFETY MARIGIN 2;1
Certificate of Independence:
Locke Bowden,P.E.does not have,not will acquire a financial interest in any company manufacturing or distributing products
under this evaluation. �,�++a+�+I-) " .00,
Locke Bowden,P.E. is not owned,operated,or controlled by any company,manufacturer,or distributI4 bJ44t4Wif t�%.
report. �.C); ��' °• ': �''i
Rits rti
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
6ch ed.,with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 6th ed,Section 1507.1.1
2. Products are compliant for State of Florida product approval per Rule 61G20-3
3. Compliance Method: 1-D
4. Fire classification is not part of this acceptance.Shear diaphragm values are outside this report.
5. All support framing compliant w/Florida Building Code 2017, Chapters 22 for Steel,23 for Wood and 16 for
Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for"project specific approval" by local
authorities,authorized by the code,and is the responsibility of others.
7. This report does not imply warranty, installation, recommended product use outside of this report.
_Fasteners-
09-15 Hex-Heed Screws With 5V-CrirrV" Root Panel
EPDA9 Bonded Steel Washers
' ' I
� 1
I
f'
Deck.
-15132"or greater Plywood.or
-Wood plank
Fasteners-
09-15 Hex-Head Screws With 5V-Crlmp" Roof Panel
EPDM Banded Steel Washers
' - -
I
Cf �� a
a r
-- —.�_�.T---T---Tom•—____���____���.v�__-__� -
Deck:
-15132"or greater Plywood.or
-Wood plank