Loading...
HomeMy WebLinkAboutAPPROVED Standing Seam NOA10/11/2018 Florida Building Code Online ProfessionalRegulation L AL r BCIS Home I Log In I User Registration Hot Topics I Submit Surcharge I Stats & Facts I Publications I Contact Us I BCIS Site Map I Links Search FI 17da r Product Approval D,,-. �` USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL17022-R7 Application Type Revision Code Version 2017 Application Status Approved Comments 08/18/2017v. date reapply 08/21/17 Archived Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772) 872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf Standard TAS 125 UL 1897 UL 580 Year 2003 2012 2006 Sections from the Code http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 1/3 10/11 /2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/18/2017 08/25/2017 08/28/2017 10/10/2017 FL # Model, Number or Name Description 17022.1 1 - "5V Crimp" (R6) 26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.1 5 V CRIMP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.1 5 V CRIMP ssrpdf assembly in compliance with the installation method listed in Created by Independent Third Party: Yes this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.2 2 - "5V Crimp" (R6) 0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof panel, mechanically attached to 15/32" plywood or Wood Deck with exposed fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions. Install the FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.3 13 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.4 14 - "1.5" Mechanical Seam" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.5 15 - "1 in. Nail Strip" (R5) 1.5" rib height, 16" wide, 24 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.3 1.5 MECHANICAL seam 249a ssrpdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.3 1.5 MECHANICAL seam 249a ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to 15/32" plywood or Wood Deck with clips and fasteners. Installation Instructions FL17022 R7 II FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM ALUMINUM ssr.pdf Created by Independent Third Party: Yes 1" rib height, 16" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL17022 R7 II FL 17022.5 1.0 NAILSTRIP ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for conditions and limitations FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.pdf of use. Install the assembly in compliance with the installation Created by Independent Third Party: Yes http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 2/3 10/11 /2018 Florida Building Code Online method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.6 16 - "1 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.7 17 - "1.5 in. Nail Strip" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.8 18 - "EMAX Rib" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 17022.9 19 - " PBR MAX" (R5) Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/ -Table A Other: Refer to evaluation report for conditions and limitations of use. Install the assembly in compliance with the installation method listed in this report and applicable code sections of FBC. Refer to manufacturer's installation instructions. 1" rib height, 16" wide, 0.032" aluminum, standing seam roof panel mechanically attached to attached to 15/32" plywood or Wood Deck with fasteners, Installation Instructions FL17022 R7 II FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0.032 ALUM ssr.pdf Created by Independent Third Party: Yes 1.5" rib height, 19" wide, 26 gauge steel, standing seam roof panel mechanically attached to 15/32" plywood or wood deck with fasteners. Installation Instructions FL17022 R7 II FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr.pdf Created by Independent Third Party: Yes 29 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 177022.8 EMAX Rib ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 177022.8 EMAX Rib ssr pdf Created by Independent Third Party: Yes 26 gauge steel, lapped roof panel mechanically attached to 15/32" plywood or wood deck with exposed fasteners. Installation Instructions FL17022 R7 II FL 17022.9 PBR RIB ssr.pdf Verified By: Locke Bowden, P.E. 49704 Created by Independent Third Party: Yes Evaluation Reports FL17022 R7 AE FL 17022.9 PBR RIB ssrpdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® r] Credit Card Safe http://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgv2aBQpHpQQe6rMZMkUEoR%2bGxHGxFe5QkCHzEgvOQveeg%3d%3d 3/3 2160 SW Poma Drive Palm City, FL 34990 (.772 )872-8034 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 1" Nailstrip 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.) Rib Height 1" Corrosion Resistant Compliant: FBC Sec. 1507.4.3 Fastener 1: #10 x 1" (mina Pancake Head Wood Screw to penetrate 3/16" (mina thru bottom of support. Adhesive/Sealant : Bostik 915' Chem -Chalk one component, polyurethane adhesive with 3/16" continuous bead application along base of male rib vertical flange at each panel seam. Underlayment: To be compliant with FBC Sec 1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. Install Details: Table A Allowable Loads DESIGN PRESSURE* FASTENER SPACING SEAM ADHESIVE METHOD 1 -86 PSF Main field 6" O.C. Not required METHOD 2 —F-97.25 PSF Perimeter T 6" O.C. 3/16" continuous bead Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2 EQUIVALENCY: UL1897-04 is equivalent to Test Standard UL1897-12. *Design Pressure margin of safety 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial iWpM5f41vq9y company manufacturing or distributing products under this evaluation. `��`�LD• Br�� "�,,� Locke Bowden, P.E. is not owned, operated, or controlled' y y mph , PsanY%cturer, or distributing products under this report. seal STATE OF 7. �a r♦• !OR0D '.• , 'r . '< <:ONAL Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details 16" Panel Profile 16" o.c. 3/4" f Deck: - 15/32" or greater Plywood, or - Wood plank Integral Snap Lock For METHOD 2: Apply 3/16" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange Fastener #10 x 1" Min. per Table "A" Pancake Head Wood Screw (Typical Fastening Pattern Across Width) FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details - 15/32" or greater Plywood, or - Wood plank FactPnPr Isometric View FUI MULI IVU L Apply 3/16" Bead Bostik 915TM Sealant Continuous Along Male Rib Vertical Flange (Refer to Table "A")