REVISION- Amazon Delivery Station - DVB1 (12.07.20)
DRAWING INDEXSheetNumberFIRE ALARM SYMBOL LEGENDSheetTitleFA-001Floorplans (FA-100 Series)FA-101PARTIAL MAIN FLOOR FIRE ALARM PLANCOVER SHEETSCOPE OF WORKPROJECT DIRECTORYSiteJohnson Controls DistrictB BUSINESS GROUPAPPLICABLE CODES & STANDARDSJURISDICTIONS WITHIN THE STATE MAY HAVE AMENDMENTS TO THE STATE ADOPTED CODE. CHECK WITH THELOCAL JURISDICTION AUTHORITY FOR MORE DETAILS.FLORIDA FIRE PREVENTION CODE, SIXTH EDITION (2017)-NFPA 1, FIRE CODE, 2015 EDITION-NFPA 101, LIFE SAFETY CODE, 2015 EDITIONFLORIDA BUILDING CODE, SIXTH EDITION (2017)-INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION-NFPA 70, NATIONAL ELECTRIC CODE, 2014 EDITION-NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2013 EDITIONJOHNSON CONTROLS CONTACTSPHONE:Drawings Prepared ByLouis Colosimoadvanceengineeringfa@gmail.com443-619-9685ABBREVIATIONS LEGENDDEVICE TAG LEGENDGENERAL NOTESSHEET:FA-001COVER SHEETDRAWN BY:CHECKED BY:ISSUE DATE:JOB #:PROJECT #:SYSTEM:FIRE ALARM SYSTEMLJCCS11/16/20JOHNSON CONTROLS © 2020AC = ABOVE CEILINGAFF = ABOVE FINISHED FLOORAHJ = AUTHORITY HAVING JURISDICTIONALM = ALARMANN = ANNUNCIATORBMS = BUILDING MANAGEMENT SYSTEMC = CEILING MOUNTEDCD = CANDELA RATINGDET = DETECTORDGP = DATA GATHERING PANELE = EXISTING TO REMAINEOL = END OF LINEEPO = EMERGENCY POWER OFFFAA = FIRE ALARM ANNUNCIATORFACP = FIRE ALARM CONTROL PANELFATC = FIRE ALARM TERMINAL CABINETFBO = FURNISHED BY OTHERSFCC = FIRE COMMAND CENTERFSD = FIRE SMOKE DAMPERFTR = FIRE ALARM TRANSPONDERH = HIGH HUMIDITYHT = HEIGHTHVAC = HEATING VENTILATION & AIR CONDITIONINGIMS = INFORMATION MANAGEMENT SYSTEMMAX = MAXIMUMMIN = MINIMUMN/A = NOT APPLICABLENAC = NOTIFICATION APPLIANCE CIRCUITNDU = NETWORK DISPLAY UNITNEC = NATIONAL ELECTRIC CODENFPA = NATIONAL FIRE PROTECTION ASSOCIATIONNIC = NOT IN CONTRACTNPU = NETWORK PROCESSING UNITNTS = NOT TO SCALEPAP = PRE-ACTION PANELRC = EXISTING TO REMOVE AND COVERRD = EXISTING DEVICE TO BE RELOCATEDRL = RELOCATED DEVICERR = REMOVE EXISTING & REPLACE WITH NEWSCC = STATUS COMMAND CENTERSLC = SIGNALING LINE CIRCUITSMK = SMOKESUPV = SUPERVISORYTAC = TRUEALERT ADDRESSABLE CONTROLLERTRBL = TROUBLETS = TAMPER SWITCHTYP = TYPICALUON = UNLESS OTHERWISE NOTEDVCC = VOICE COMMAND CENTERVT = VALVE TAMPERW = WATTAGEW/ = WITHW/O = WITHOUTWF = WATERFLOWWG = WIRE GUARDWP = WEATHERPROOFXP = EXPLOSION PROOF1:T2:A2:1-1(E1:1)PANEL DESIGNATORFA: = FACP (NON-NETWORK)#: = NODE NUMBERT#: = TRANSPONDER NUMBER#:T# = NODE:TRANSPONDER NUMBERN#: = NAC EXTENDER NUMBERCIRCUIT DESIGNATORA#:# = EPS1 NUMBER:IDNAC2 CHANNEL NUMBERD# = DOOR HOLDER CIRCUIT NUMBERF# = FIRE PHONE CIRCUITH# = AUDIBLE (HORN) CIRCUIT NUMBERM# = IDNET LOOP NUMBERP# = POWER CIRCUIT NUMBERS# = SPEAKER CIRCUIT NUMBERV# = VISUAL CIRCUIT NUMBERZ# = ZONE NUMBERDEVICE NUMBERBRANCH / ISOLATED LOOP DESIGNATOR:(L#) = IDNET ISOLATED LOOP NUMBER(#) = IDNAC BRANCH NUMBER(E#:#) = EPR3 NUMBER:BRANCH NUMBER1. EPS = ENHANCED POWER SUPPLY2. IDNAC = ADDRESSABLE NOTIFICATION CIRCUIT3. EPR = ENHANCED POWER REPEATERISSUE LOG:Revisions shown with # symbol MARK CAD CHK DESCRIPTION OCCUPANCY TYPE(S):SCOPE OF WORK WILL BE TO PROVIDE NEW DUCT DETECTORS FOR THE AREA OF WORK IN THIS EXISTING BUILDING.IMPORTANT NOTICE TO USER: This information may not be sold or transferred to any third party, used on other projects or additions to the projectfor which it was prepared, or used for completion of this project by any third party. Johnson Controls disclaims all liability for the use or reuse ofaltered files by the user or any third party and such use will be a user's sole risk. User shall, to the fullest extent permitted by law, defend, indemnify,and hold Johnson Controls harmless from any and all claims for loss, damage or injury arising directly or indirectly from any such unauthorized use.1.THESE DRAWINGS DEPICT GENERAL LOCATIONS OF LIFE SAFETY EQUIPMENT & FIELD DEVICES. EXACT ROUTING OF CONDUITS ISTO BE DETERMINED IN THE FIELD BY THE INSTALLING CONTRACTOR TO SUIT CONDITIONS. ALL CHANGES SHALL BE CLEARLYINDICATED ON THE RECORD DRAWINGS.2.SHOULD ANY CONDITIONS EXIST THAT DIFFER FROM WHAT IS INDICATED ON THESE DRAWINGS WHICH CAUSE MAJORDEVIATIONS IN THE WORK SHOWN, THE CONTRACTOR SHALL CONTACT JOHNSON CONTROLS IN A TIMELY MANNER SO AS NOTTO IMPAIR THE CONSTRUCTION SCHEDULE.3.CONTRACTOR IS RESPONSIBLE FOR MAKING AND OBTAINING APPROVAL FOR ALL NECESSARY ADJUSTMENTS IN CIRCUITING ASREQUIRED TO ACCOMMODATE THE RELOCATION OF EQUIPMENT AND/OR DEVICES WHICH ARE AFFECTED BY ANY AUTHORIZEDCHANGE. ALL CHANGES SHALL BE CLEARLY INDICATED ON THE RECORD DRAWINGS.4.A STAMPED SET OF APPROVED FIRE ALARM DRAWINGS SHALL BE AT THE JOB SITE AND SHALL BE USED FOR INSTALLATION.5.THE POWER CIRCUIT TO THE FACP AND TO THE FIRE ALARM POWER SUPPLIES SHALL BE ON A DEDICATED 120V, 20A BRANCHCIRCUIT BREAKER, AND SHALL HAVE A RED MARKING, LOCK-ON PROVISION AND SHALL BE IDENTIFIED AS "FIRE ALARM CIRCUITCONTROL." THE LOCATION OF THE CIRCUIT DISCONNECT MEANS (CIRCUIT BREAKER) SHALL BE PERMANENTLY IDENTIFIED ATTHE FIRE ALARM CONTROL UNIT.6.UPDATE THE AS-BUILT DRAWING SET DAILY WITH JOB PROGRESS. RETURN THE AS-BUILT DRAWING SET TO JOHNSON CONTROLSNO LATER THAN 7 DAYS AFTER FINAL TEST.7.THE CONTRACTOR WILL MAINTAIN ALL AREAS OF THE BUILDING IN A NEAT AND WORKMANLIKE MANNER.8.DO NOT APPLY POWER EXCEPT IN THE PRESENCE OF A FACTORY TRAINED JOHNSON CONTROLS TECHNICAL REPRESENTATIVE.9.ANY SMOKE DETECTOR HEAD INSTALLED BEFORE THE BUILDING IS CLEANED AND ACCEPTED SHALL BE COVERED TO PROTECTFROM DUST. ANY FALSE ALARMS DUE TO DIRT CONTAMINATED HEADS SHALL BE THE RESPONSIBILITY OF THE FIRE ALARMINSTALLER.10.THE FIRE ALARM INSTALLER WILL MAINTAIN THE FIRE RESISTANCE INTEGRITY OF ALL WALL, CEILING, AND ROOF ASSEMBLIESANY TIME THAT WORK IS NOT ACTIVELY BEING PERFORMED.11.INSTALLATION OF DEVICES SHALL BE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. POWER LIMITED ANDNON-POWER LIMITED FIELD WIRING MUST BE INSTALLED WITHIN THE FACP ENCLOSURE IN ACCORDANCE WITHMANUFACTURER'S INSTRUCTIONS AND APPLICABLE ELECTRICAL CODES. REFER TO 'APPLICABLE CODES & STANDARDS' FORSPECIFIC CODE REFERENCES.12.FIRE ALARM CIRCUITS SHALL BE IDENTIFIED IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. MARK ALL FIRE ALARMWIRES IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODE SECTIONS FOR POWER LIMITED AND NON-POWER LIMITED WIRE.14 FIRE ALARM CABLE INSTALLED IN DUCTS, PLENUM, AND OTHER SPACES USED FOR ENVIRONMENTAL AIR SHALL BE TYPE FPLP.15.FIRE ALARM CABLE INSTALLED IN THE VERTICAL RUNS AND PENETRATING MORE THAN ONE FLOOR OR CABLES INSTALLED INVERTICAL RUNS IN SHAFTS SHALL BE TYPE FPLR.16.ALL WIRING, INCLUDING SHIELDS MUST BE DRY AND FREE OF SHORTS AND GROUNDS.17.ALL SHIELDED WIRE MUST HAVE SHIELD CONTINUITY AT FULL LENGTH OF THE WIRE.18.ONLY SYSTEM WIRING CAN BE RUN IN THE SAME CONDUIT.19.120VAC IS NOT PERMITTED IN THE SAME CONDUIT WITH LOW VOLTAGE WIRING.20.MAINTAIN MAXIMUM CONDUIT FILL RATIO AS PER APPLICABLE ELECTRICAL CODES REQUIREMENTS.21.EXISTING CONDUITS MAY BE USED BY THE INSTALLATION CONTRACTOR AS DEEMED NECESSARY; HOWEVER, ANY EXISTINGCONDUIT WILL BE USED ONLY IF CONDUITS MEET CURRENT STANDARDS AND CODES. JOHNSON CONTROLS MAKES NOSTATEMENTS WRITTEN OR VERBAL AS TO THE CONDITION OF EXISTING CONDUITS.22.ALL WIRING, & INITIATING DEVICES, SHALL BE SUPERVISED TO THE POINT OF ANNUNCIATION (F/A PANEL TO SUPERVISE ALLCIRCUITS AND INITIATING DEVICES).23.WIRING SHALL NOT BE LOOPED THROUGH DEVICES: WIRE MUST BE CUT FOR IN AND OUT.24.SUBSCRIPT SHOWN NEXT TO INITIATING DEVICES DENOTES THAT DEVICE'S ADDRESS ON THE SIGNALING LINE CIRCUIT (SLC).25.DASHED LINES WITH A SUBSCRIPT (EX) REPRESENT EXISTING EQUIPMENT TO REMAIN.26.SUBSCRIPT "N" DENOTES NEW DEVICES.27.INSTALLATION SHALL COMPLY WITH NFPA 1, 2015, APPLICABLE CHAPTERS.28.INSTALLATION SHALL COMPLY WITH NFPA 72, 2013, APPLICABLE CHAPTERS.29.INSTALLATION SHALL COMPLY WITH NFPA 101, 2015, APPLICABLE CHAPTERS.30.INSTALLATION SHALL COMPLY WITH NEC 2014 APPLICABLE CHAPTERS.31.THE DESIGN INSTALLATION COMPLIES WITH F.B.C.17 6TH EDITION.32.THE DESIGN INSTALLATION COMPLIES WITH THE FLORIDA FIRE PREVENTION CODE (FFPC) 6TH EDITION.33.RACEWAYS TO BE EMT, WIREMOLD, PVC & FREEWIRE (FISHED) WHERE CODE PERMITS. MINIMUM RACEWAY 3/4". 40% CONDUITFILL MAXIMUM.34.SYSTEM SHALL BE GROUNDED PER MANUFACTURES SPECIFICATIONS.35.SMOKE DETECTORS SHALL NOT BE LOCATED WITHIN 3' OF A/C DIFFUSERS, KITCHEN OR BATHROOM DOORS.36.CEILING MOUNTED DEVICES SHALL BE LOCATED AT A HEIGHT OF 10'-0" +/- ON SMOOTH FLAT CEILING UNLESS OTHERWISENOTED.37.THIS IS A BATTERY BACKUP SYSTEM, WITH 24 HOURS OF BACKUP & 5 MINUTES ALARM. SHOULD LOSS OF NORMAL 120 VACOPERATING POWER OCCUR, THE FACP WILL AUTOMATICALLY TRANSFER TO STANDBY BATTERY.38.FIRE ALARM PANEL & ANY ASSOCIATED FIRE ALARM TRANSPONDERS SHALL BE FED BY A 120 VAC, SINGLE PHASE, 20 AMP,DEDICATED BREAKER.39.RACKS, SHELVES AND EQUIPMENT ARE ALL LOWER THAN 80" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED.40.ALL EQUIPMENT, FIRE CAULK TO BE U.L. LISTED.41.THIS IS AN EXISTING FULLY SPRINKLERED, 1 STORY BUILDING.42.THE ROOM CONTAINING THE FACP IS MECHANICALLY VENTED.28.THIS IS A LISTED CERTIFICATED CENTRAL STATION SERVICE FIRE ALARM SYSTEM.29.MAXIMUM MOUNTING HEIGHT FOR FACP AND POWER SUPPLIES SHALL BE 6' TO THE TOP ON THE ENCLOSURES.General Information (FA-000 Series)DATE 10550 COMMERCE PARKWAY MIRMAR, FLORIDA 33025 Phone: 954-431-3700 Johnson ControlsJohnsonControlsDVB1 - DELIVERY STATION7440 COMMERCIAL CIRCLEFORT PIERCE, FL 34651CTRL. UNIT ANNUNCIATIONNOTIFICATIONFIRE SAFETY CONTROLSYSTEM INPUTSA B C D E F G H I12345678910111213141516171819202122232425SMOKE SENSOR/DETECTORMANUAL PULL STATIONDUCT SENSOR/DETECTORWATERFLOW SWITCHTAMPER SWITCHPOST INDICATOR VALVE SWITCHOPEN CIRCUIT OR GROUND FAULTFIRE ALARM SYSTEM LOW BATTERYCLASS B NOTIFICATION CIRCUIT (NAC) - SHORTJ K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ12345678910111213141516171819202122232425A B C D E F G H IJ K L M N O P Q R S T U V W X Y Z AA AB ACADAE AF AG AHAI AJREMARKSA C T U A T E C OM M O N A L A RM S I G N A L I N D I C A T O RSYSTEM OUTPUTSACTUATE AUDIBLE ALARM SIGNALA C T U A T E C O MM O N S U P E R V I S O R Y S I G N A L I N D I C A T O R A C T U A T E A U D I B L E T R O U B L E S I G N A LACTUATE AUDIBLE SUPERVISORY SIGNALACTUATE COMMON TROUBLE SIGNAL INDICATORA C T U A T E A P P R O P R I A T E L O C A T I O N I N D I C A T O RACTUATE ALL AUDIBLE EVACUATION SIGNALS (EXISTING)DISPLAY CHANGE OF STATUS (ON FACP & ANNUNCIATOR)T R A N SM I T A L A RM S I G N A L T O S U P E R V I S I N G S T A T I O NTRANSMIT TROUBLE SIGNAL TO SUPERVISING STATIONTRANSMIT SUPV. SIGNAL TO SUPERVISING STATIONSPRINKLED PROTECTION: BUILDING IS FULLY SPRINKLEDACTUATE ALL VISIBLE EVACUATION SIGNALS (EXISTING)FIRE ALARM AC POWER FAILUREFIRE ALARM WIRE LISTCIRCUIT DESCRIPTIONBMPTSP SOLIDTSP SOLID2 COND. SOLIDR1/2"3/4"1"0.12 SQ INCH *0.21 SQ INCH *0.34 SQ INCH *2 COND. SOLID1-1/4"1-1/2"2"18 AWG18 AWG14 AWG14 AWGMAX CONDUCTOR AREA0.60 SQ INCH *0.82 SQ INCH *1.34 SQ INCH **40% FILL PER N.E.C.SUBSCRIPT "u": UNSHIELDED CABLES MIXED WITHSHIELDED CABLES OF SAME CIRCUIT DESIGNATION.60pf/ft. MAX CAPACITANCE; 3twists/ft. RECOMMENDEDACCEPTABLE CABLETYPESXXXXXXXXXXFPLR FPLP TFFN THHN OUTDOOR C.I.**OUTDOOR AERIAL CABLE REQUIRES MESSENGERITEMS SUCH AS CAPACITANCE BETWEEN CONDUCTORS AND WIRE GAUGE CAN BE CRUCIAL TO THE CIRCUITDESIGN OF THIS SYSTEM INSTALLATION. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR SELECTING ANDINSTALLING CABLE MANUFACTURER AND MODEL THAT MEETS OR EXCEEDS THE ABOVE REQUIREMENTS.RECOMMENDED CABLE MANUFACTURERS AND MODEL NUMBERS ARE AVAILABLE UPON REQUEST.RUI/N2 COMMUNICATIONMAPNET/IDNETPOWERRELAYCONDUIT SIZECONDUIT SIZECONSTRUCTIONGAUGECIRCUIT PROPERTIESMAX CONDUCTOR AREANOTESFIRE ALARM SYMBOL LEGENDSYMBOLBACKBOX CODESCODE BOX SPECIFICATIONS4A 4" SQ. BOX 1 1/2" DEEP4B 4" SQ. BOX 1 1/2" DEEP W/ COVER4C 4" SQ. BOX 1 1/2" DEEP W/ 1 1/2" EXT. RING4D 4" SQ. BOX 2 1/8" DEEP4E 4" SQ. BOX 2 1/8" DEEP W/ COVER4F 4" SQ. BOX 2 1/8" DEEP W/ 1 1/2" EXT. RING4G 4" SQ. BOX 2 1/8" DEEP W/ SINGLE GANG COVER4H 4" SQ. BOX 2 1/8" DEEP W/ TWO GANG COVER4J 4" SQ. BOX 2 1/2" DEEP4K 4" OCT. BOX 1 1/2" DEEP4L 4" OCT. BOX 1 1/2" DEEP W/ 1 1/2" EXT. RING4M 4 11/16" SQ. BOX 2 1/8" DEEP4N 4 11/16" SQ. BOX 1 1/2" DEEP W/ 1 1/2" EXT. RING4P 4 11/16" SQ. BOX 2 1/8" DEEP W/ 1 1/2" EXT. RING4Q 4" SQ. BOX 1 1/2" DEEP W/4098-9832 ADAPTER4R 4" SQ. BOX 1 1/2" DEEP W/RACO 787 OR EQUIV.4S 4" SQ. BOX 1 1/2" DEEP W/4098-9863 ADAPTER1A SINGLE GANG BOX 1 1/2" DEEP1B SINGLE GANG BOX 2" DEEP1C SINGLE GANG BOX 2 1/8" DEEP1D SINGLE GANG BOX 2 1/8" DEEP W/COVERCODE BOX SPECIFICATIONS1E SINGLE GANG BOX 2 1/2" DEEP1F SINGLE GANG BOX 2 1/2" DEEP W/COVER1G SINGLE GANG BOX 2 3/4" DEEP1H SINGLE GANG BOX 3 1/2" DEEP2A DOUBLE GANG BOX 2" DEEP2B TWO GANG BOX 2 1/2" DEEP2C TWO GANG BOX 2 3/4" DEEP5A 5 GANG BOX 2 1/2" DEEP6A 6 SINGLE GANG BOXES 3 1/2" DEEP6B 6 GANG BOX6C 6 GANG BOX 2 1/2" DEEP6D 6 GANG BOX 3 1/2" DEEPFBO FURNISHED BY OTHERSMFG SUPPLIED BY MANUFACTURERMDW MOUNTS TO DUCTWORKMBD MOUNTS IN BOX BEHIND DETECTORWM WALL MOUNTDT DESK TOP MOUNTDS REFER TO PRODUCT DATASHEETNR NO BACKBOX REQUIREDTRM 3.5" WIDE SNAP TRACK W/MOUNTING SCREWSINTIATING DEVICESBRANDMODELDESCRIPTIONFOR ADDITIONAL BACK BOX OPTIONS, REFER TO THE XX-700 SERIES DRAWINGS OR PRODUCT DATA SHEETS ANDINSTALLATION INSTRUCTIONS.BOXCODENOTIFICATION DEVICESWALL MOUNT HORN/STORBESYSTEMSENSORMFGSPSWNOTIFIERMFGDUCT DETECTORDNR10550 COMMERCE PARKWAYMIRAMAR, FL 33025PHONE: 954-431-3700Project ManagerChris Salmanchristopher.salman@jci.com786-918-3240PHONE:DVB1 - DELIVERY STATIONFIRE ALARM MODIFICATIONRELAY MODULEMFGREMOTE TEST STATIONMFGHORN STROBE - CEILING MOUNTMFGNOTIFIERFRM-1NOTIFIERRTS-151KEYSYSTEMSENSORSPSCW6196204027440 Commercial Circle Fort Pierce, FL 34651 DVB1 - Delivery Station11/25/2020