HomeMy WebLinkAboutSED - WALL SIGN REV1� ILLUMINATED CHANNEL LETTERS W/ LOGO
SO.Sx29.9=1509.95 TotalSignArea:
20%=301.99'ALLOWABLE 20% of wall face area fronting on the main-s3Nelether Future Land Us
PROPOSED-164'
�//I� 1740 HILL AVENUE
WEST PALM BEACH, FL
33407
�' 561-840-6382
ES0000229 FAX: 561-840-6385
CUSTOMER:
souYH Easy
POOLS &SPAS
7330 US -1
PORT ST LUCIE, FL 34952
-9.66"
DESIGNER: Pam Reeves
DATE: 11.10.2020
REVISED: 11.16.2020
screws tc
trimcap G
Minimum
Drain
dame
P
I-s-
switchponl eztenor wall
as per N.E.C.
Arvcxoa uHEouLE
qTv orsPADNG
WALL MATERIAL
ANCHOR TYPE
CONCRETE Iaksil or
HOLLOW MASONRY
1/4"THREADED 0.005 WITH MIN 2"EMBED INADHESIVE
(Bf TOTAL AT IDGO
1/4"TAPCONG(OR EQUIV)WITH I.JS"EMBED
(61 TOTALAT LOGO
1/4" E%PANSION ANCHORS WITH 2.G" EMBED
(4) TOTAL AT LOGO
],/2' PLYW000
(NO ACCESG BEHIND)
1/4" TOGGLE BOLTS
141 TOTAL AT LOGO
1/4"WOOD SCREWS, FULL EMBED
(G)TOTALAT LOGO
METALSNOS/PANELS
N10 METAL X0.EWST0 MIN 18ga STEEL OR 0.090"ALUM
(41 TOTAL AT LOGO
HOLLOW WALL♦BLOCKING
1/4"THRUBOLTS OR LAGS TO SOLID BLOG(ING BEHIND
I4I TOTAL AT LOGO
AT CHANNEL IETfEIas, USE ANY ANCHOR OPTION SHOWN: MIN (31 PER LETTER
CCOPYRIGHT 2D16
ev NENP nsx R
SERVICE. ALL
mGHTS RESERVED
ALL ELECTRICAL ES0000229
U�To RE u.0 LISTED Electrical Qualifier:
XALL MEET :NO Stephen M. Kemp
N.E.C. STANDARDS
4�
�z
r
�CQ�"���� �W,
ti ��"Yeapr,aea-aaRn_E
LED LIgMs
Bushing through metal to prevent wire from getting cut
REF ANCHOR SCHEDULE
FOR MOUNTING OPTIONS
Primarryy electrical source
NEC 800.5
1/2" Min. conduit
Consists of channel letters,
and disconnect switch.
Suitable for damp, wet,
or outdoor locations.
0 �� 12V LED Tranformer
' LISMd diSCOnnect switch
20 amp as per NEC al
back of sign
All building penetrations
sealed, to comply with
applicable bldg. code req.
Primary wire size - N 12 TH W N
DlsconneU switch: at base of sign, 20 amp single pole
Astronomkal time clock at panel room or photo[ JI
Maximum load -16 amps 120 volh per cacuit maximum circud sae 20 amps per NEC 600-6A
Power supply: 120v-277 Multi Volf bOW 12v DC
Illumination: OSRAM .75 Watts per module
Conduit -minimum 1/2
Total sign load- 2.4 amps 120 volts
Total sign circuits- 1
All components shall be U.L. approved
Ballas}s shall have independent U.L. approval (fused where required)
All installs}ions shall be in compliance wi}h N.E.C. and state, county, or local codes
All signs shall be bonded }o building equipment bonding conductor per N.E.C. 250
5}ate Of: Florida
County of: Palm Beach
The forgoing document was acknowledged
before meday of
Your Name Here, Notary Public
My Commission F-shires:
�a�
_ rea
moo«
V LLV
3
>=LLm
�m
z A CO
om°r
n
0
�_ c
9
N
all N
a
c m
41
Ev
o a
= O
3 N
E it
d= �
IIQ
H Y
m
_�
c n
rn Y,
� �
� II
n �
Zo
O U
a -a
V �
Ya
¢¢
tv
E =
>,'S
��
�c
�a
�°
aZ
3
sew t ' &ouWdethe Hi hVelodt HunimlR]nne (HVNiI. •ihisen ineedng tenifiesanlythestmtmmlintegniyofthosesystems,<ompomnts,and/orothermnscnlriloneepllaTlyspecified herein. • EIetMTal nmes,detalh, &specifications are pmuided byand arethesole responslbilityoftheeleariral mmrador.Noelendtal reWewhasbeen pedomledand nomLifKatlmofsub isinteMed. •SLrominl desgn meets requlrementsofACn1&14,AISL 360.10,ADM7-is,& N05-15,
General •Designis in accordancewiththerequiremennaflhe Fla Bldg Eodeeth Ed (i01]iforu Thin q Y 9
Notes: as applinble.•Sted mmponenn shah he coated, palmed, or othemise pouted agains[mnodon per FBLSe[33m.LZl]1.6.•Num components In cmtaa withsteel or embedded in mmrete shall be palmed or pmtened as prescribed in ADMt-16pa),a plastidneaprene spawn povlded.•All ellposed fasteners shall be S.S. or haves pMedive matlng for mlroslon prmedlon.•All welding shall mmpty with AWS requirements.•Sted welds:E]dxx eledrodes.•Aluminum welds:4D43 filler alloy.•Alum emmsioM: 6a6YT6 or shmge6 O.N.D.