Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2 (('' BCIS Home Log In User Registration Hot Topics Submit Surcharge Slats&Facts I Publications Contact Us BCIS Site Map Links Search j ri��ui� Approval *Product USER:Public User Far x.? ,nzx ^r Product Approval Menu>Product or Aoolication Search>Application List>Application Detail File Copy i" 6 .{J/ FL# F R4 n Application Type Revision Code Version REVIEWED FOR Application Status Approved fl CODE COMPLIANCE Comments _ ST■ /� Archived CIE COU kyBOCCI Product Manufacturer Tri County Metals w Address/Phone/Email 301 SE 16th Street Trenton,FL 32693 (352)463-8400 RECEIVED chrisw@tricountymetals.com Authorized Signature Chris Weatherilt DEC 0 7 1010 chrisw@tricountymetals.com aftmellt Permlttln9.Dep Technical Representative St.Lucle COlintN Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer La Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Terrence E.Wolfe the Evaluation Report Florida License PE-44923 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 06/02/2024 Validated By Brian]aks,P.E. J Validation Checklist-Hardcopy Received Certificate of Independence FL4595 R4 CGI Letter of Certification secured.odf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvV o%2boyCR... 12/7/2020 Florida Building Code Online Page 2 of 2 Date Submitted 08/15/2017 Date Validated 08/17/2017 Date Pending FBC Approval 08/23/2017 Date Approved 10/10/2017 Date Revised 10/13/2020 Summary of Products Go to Page 0 d Page 2/2 0 0 FL# Model,Number or Name Description 4595.21 Ultra-Rib 29 Ga.Ultra-Rib Roof Panel over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ:No FL4595 R4 II 29 Ga. Ultra-Rib Panel over Ply with shingles Approved for use outside HVHZ:Yes secured.psif Impact Resistant:N/A Verified By:Terrence E.Wolfe,P.E.44923 Design Pressure:+N/A/-101.OPSF Created by Independent Third Party: Yes Other:-63.5 psf @ 24"D.C.-101.0 psf @ 24"D.C. Install Evaluation Reports per manufacturer's details.Not for use in HVHZ Zones. FL4595 R4 AE 29 Ga. Ultra-Rib Panel over Ply with shingles secured.odf Created by Independent Third Party:Yes 4595.22 Ultra-Rib 29 Ga.Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Limits of a Installation Instructions Appr ed for use in HVHZ:No FL4595 R4 II 29 Ga. Ultra Rib Panel over lx4 w shingles pproved for use outside HVHZ:Yes secured.Ddf Impact Resistant:N/A Verified By:Terrence E.Wolfe,P.E.44923 Design Pressure:+N/A/-131.OPSF Created by Independent Third Party:Yes Other:-52.5 psf @ 24"D.C.fastener spacing.-131.0 psf @ Evaluation Reports 6"D.C.fastener spacing.Install per manufacturer's details. FL4595 R4 AE 29 Ga. Ultra Rib Panel over.-1x4 t_v_shinales Not for use in HVHZ Zones. secured.otif Created by Independent Third Party: Yes Go to Page 40 110 Page 2/2 Back Next. Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click hem. Product Approval Accepts: E Credit Card Sate https://www.floridabuilding.org/pr/pr_app_dtl.aspx?pararn=wGEVXQwtDgvVo`/o2boyCR... 12/7/2020 Force Engineering&Testing Inc. 19530 Ramblewood Drive I-Iurnble,TX 77338 Product Evaluation Report TRI COUNTY METALS 29 Ga. Ultra-Rib Roof Panel over 1x4 Wood Purlins over 15/32"Plywood Florida Product Approval #4595.22 R4 Florida Building Code 2017 Per Rule 61G20-3 Method:1—D Category:Roofing Subcategory: Metal Roofing Compliance Method:61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Tri County Metals 301 SE 16`h Street Trenton,Florida 32693 Engineer Evaluator: Terrence E.Wolfe,P.E.#44923 Florida Evaluation ANE ID:1920 Validator: Brian Jaks P.E.#70159 Contents: Evaluation Report Pages 1-4 � O � C1� NsF `�,rr " y No.444 �1 •o' STATE OF ►�> FL#4595.22 R4 August 14, 2017 Force Engineering&Testing Inc. 19530 Raznblewood Drive I-I11Z1ihle,TX 77338 Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017,Sections 1504.3.2,1SO4.7. Product Description: Ultra-Rib Roof Panel, Min. 29 Ga. Steel, 36" Wide, through fastened roof panel with fasteners through the panel rib over 1x4 wood purlins over one layer of asphalt shingles (optional) over min. 15/32" APA Plywood decking. Non- Structural Application. Panel Material/Standards: Material: Min.29 Ga.Steel conforming to Florida Building Code 2017 Section 1507.4.3. Yield Strength: Min.80.0 ksi Corrosion Resistance:Panel Material shall comply with Florida Building Code 2017,Section 1507.4.3. Panel Dimension(s): Thickness: 0.016"min. Width: 36"maximum coverage Rib Height: %"major rib at 9"O.C. Panel Fastener: #9-15 x 2" HWH Woodgrip with sealing washing or approved equal through the panel rib %"minimum penetration through plywood Corrosion Resistance:Per Florida Building Code 2017,Section 1507.4.4.. Substrate Description: Min.1x4 No.2 SYP wood purlins over maximum one layer of asphalt shingles/felt paper(optional)over min.15/32"thick APA rated plywood over supports at maximum 24"O.C. The 1x4 wood purlins shall be fastened to the plywood with (1)8d x 2%"Ring Shank Nail at 4"O.C. Design of 1x4 wood purlins,plywood and plywood supports are outside the scope of this evaluation. Substrate must be designed in accordance w/Florida Building Code 2017. Allowable Design Uplift Pressures: Table"A" Maximum Total Uplift Design Pressure: 52.5 psf 131.0 psf Fastener Pattern Through Panel Rib: 9"-9"-9"-9" 9"-9"-9"-9" Fastener Spacing: 24"O.C. 6"O.C. 'Design Pressure includes a Safety Factor=2.0. ,`���{f11111l1��I % C E N S `� • No.44444 •�• STATE OF ;w►{, . 1+' 4V . �a.P FL 4 RI V 1 ��FS.• seb� ,,��0 1+11 C % %,`, FL#4595.22 R4 Auj;ust 14, 2017 Farce Engineering&Testing Inc. 19530 Ramblewood Drive Humble,'rX 77338 Code Compliance: The product described herein has demonstrated compliance with The Florida Building Code 2014,Section 1504.3.2,1504.7. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017,as relates to Rule 61G20-3. Performance Standards: The product described herein has demonstrated compliance with: ■ UL 580-06-Test for Uplift Resistance of Roof Assemblies ■ UL 1897-2012-Uplift Test for Roof Covering Systems ■ FM 4471-92-Foot Traffic Resistance Test Reference Data: 1. UL 580-06/1897-04 Uplift Test Force Engineering&Testing,Inc.(FBC Organization#TST-5328) Report No.136-0084T-14A,B. 2. FM 4471-10,Section 4.4 Foot Traffic Resistance Test Force Engineering&Testing,Inc.(FBC Organization#TST-5328) Report No.136-0027T-12C. 3. Certificate of Independence By Terrence E.Wolfe,P.E.(No.44923)@ Force Engineering&Testing,Inc. (FBC Organization#ANE ID:1920) Test Standard Equivalency: The UL 1897-04 test standard is equivalent to the UL 1897-2012 test standard. The FM 4471-10,Foot Traffic Resistance test standard is equivalent to the FM 4471-92,Foot Traffic Resistance test standard Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017,including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12,lap sealant must be used in the panel side laps. Installation: Install per manufacturer's recommended details. ♦� it ♦♦♦♦, N,C E• Z ♦ E. O ♦ E •! i 4• 1 C NSE"-A, " NO.444 r Jar` a• STATE OF r sm.orveae. i�FS., P, .V�♦♦♦ FL#4595.22 R4 Auaust 14, 2017 Force Engineering&Testing Inc. 19530 Rainblewood Drive I-Iumble,TX 77338 Underlayment: Per Florida Building Code 2017,Section 1507.1.1 and manufacturer's installation guidelines. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear diaphragm values are outside the scope of this report. Design Procedure: Based on the dimensions of the structure,appropriate wind loads are determined using Chapter 16 of the Florida Building Code 2017 for roof cladding wind loads.These component wind loads for roof cladding are compared to the allowable pressure listed above.The design professional shall select the appropriate erection details to reference in his drawings for proper fastener attachment to his structure and analyze the panel fasteners for pullout and pullover.Support framing must be in compliance with Florida Building Code 2017 Chapter 22 for steel,Chapter 23 for wood and Chapter 16 for structural loading. � O � C E H S h. <'o 41d� ! a' STATE OF r � 0 RI FL#4595.22 R4 August 14, 2017 MINIMUM 29 GA. ULTRA—RIB PANEL 36"PANEL COVERAGE 9" 9" 9" 9" COKVNUOUS TAPE SEAL FOR USE ON SLOPES LESS THEN J:r2 .",z ..... .. Ix4 WOOD PURLINS ATTACHED TO PLYWOOD WITH H9-79'-9'-9'-9' W/ WASHER ER PATTERN (1) 8d x 2 .1/2' RING SHANK NAIL A7 4' O.C. ONE LAYER OF SHINGLES OVER ONE LAYER OF 300 FELT (OPTIONAL) OVER MINIMUM 15/32' PLYWOOD o',%t,II?sa list, � a e ` L,N gyl ��,•°C�,l J St3Ia of fit ° G ° cna ( tlra .y • b N n n No.4492 -.. a ............. a e�wa rat• " ia� e n 4 ��• °°�s8sssss®Hasa AUG 1 4 2017 12l7/2020 Tri County Metals Ultra Rib Metal Roofing Panel , I i�l� to `lou e�xt 'Qof Y®u Last a ULTRA RIB METAL ROOFING PANEL OVERVIEW This panel is manufactured in our facility.Suitable for any roof with a pitch greater than 2/12. • Applications: Residential,Agricultural, Light Commercial, Industrial • Gauge: 26 gauge and 29 gauge residential,Agricultural, Light Commercial, Industrial • Panel Profile: 36" Net coverage,5 ribs 9"On-Center, 3/4 high rib • Substrate:Steel • Finish: Siliconized Modified Polyester.Acrylic coasted Galvalume®AZ55 • Warranty: Galvalume® - 25 years and 6 months.Core Defender painted -40 years FLORIDA PRODUCT APPROVALS lov htt s: to'coun metals.com/u ltra-rib- ane V 1/6 12R/2020 Tri County Metals Ultra Rib Metal Roofing Panel 3/4 low v I � 7 r https://tricountymetals_com/ultra-rib-panel) 216