Loading...
HomeMy WebLinkAboutWind Load Calculation ,z�c�� RECEIVED 1 � COTI)y per. 0 2 2020 Permitting Department St. Luce County Property Information Building Information Owner: George Worthington Wind Zone: 170 MPH. Address: 10 Camino Del Rio Exposure Category: C Port St.Lucie,FL 34952 Minimum Building Dimension: 25 ft. Mean Roof Height: 15 ft. Risk Category: II Design Pressure Calculations i i Opening Location Device 1[ Device Device Max Positive Max Negative Number Zone Width(in) Height(in) Elevation(ft) Pressure(psf) Pressure(psf) 1 Int 62 56.5 7 35.6 -39.8 2 Int 62 56.5 7 35.6 -38.8 3 Int 62 57 7 35.6 -38.8 4 Int 62 57 7 35.6 -38.8 5 Int 82.5 57 7 34.9 -38.1 6 Int 34.75 40.5 7 37.8 -41.0 7 Int 3 4.7 5 40.5 7 37.8 -41.0 Prepared in accordance frith:ASCE 7-10.Chapter X Wind Loads-Components and Cladding.6ih Edition(2017)Florida Building Cade. Page I of I