Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 30 Block 1 Waterstone 1780 AGR Builder Name: ADAMS HOMES Street: 8712 Merano Avenue Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1513.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1245.40 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 268.00 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1900.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1780.00 ft2 6. Conditioned floor area above grade (ft2) 1780 b. Knee Wall (Vented) R=19.0 120.00 ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(177.0 sqft.), Description Area 11. Ducts a. Sup: Attic, Ret: Main, AH: Main R ft2 6 356 a. U-Factor: - Dbl, U=0.33 113.31 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 45.94 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.639 ft. Area Weighted Average SHGC: 0.272 14. Hot water systems 8. Floor Types (1780.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2 b. Conservation features EF: 0.940 b. N/A R=, ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.099 Total Proposed Modified Loads: 55.99 PASS Total Baseline Loads: 56.40 I hereby certify that the plans fications covered this calculation are in Flo ' Revi w of the plans and Q-,TUE Sz4 comp n it a nergy specifications covered by this��'' p Code. calculation indicates compliance y �''�r = `VF with the Florida Energy Code. �o� F• rrrn z, '�=`';;;� �';, O PREPARED BY: Before construction is completed DATE: 1 n-3n-21170 ingnn KPnmany this building will be inspected for C? 1. y we^ compliance with Section 553.908 * I hereby certify that this building, as designed, is in compliance Florida Statutes. 4 with the Florida Enet q-G G'pD WIS, OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an .� envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2). 10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4 FORM R405-2017 IAIPI IT CI IIIAl1AADV r+uCf%W1 IL--- orEnr%n-v- v..wI'L1..w I IXL.r Vn I PROJECT Title: Lot 30 Block 1 Waterstone 17 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1780 Lot # 30 Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 8712 Merano Avenue Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Single-family , New/Existing: New (From Plans) FL , 34951 Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1780 15664 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1780 15664 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0 1780 ftz ---- 0.38 0 0.62 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1991 ftZ 446 ftZ Medium N 0.85 N 0.85 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft' N - N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Knee Wall (Vented) Main 19 Batt 120 ft2 0.11 Wood 2 Under Attic (Vented) Main 30 Blown 1780 ftZ 0.11 Wood 10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4 FORM R405-2017 IMPI IT CI IURAAov rruCr%W1 10T ncnr%n-r WALLS Adjacent A Ornt To INA1 Type Space Cavity Width Et In Height Ef In AreaR-Vahle Sheathing Framing Solar Below R-Value Fraction a o 1 N Exterior Concrete Block - Int Insul Main 4.1 40 0 8 0 320.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Int Insul Main 4.1 40 6 8 0 324.0 ft2 0 0 0.6 0 3 SE Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 0.6 0 4 S Exterior Concrete Block - Int Insul Main 4.1 11 10 9 6 112.4 ft2 0 0 0.6 0 5 SW Exterior Concrete Block - Int Insul Main 4.1 3 0 9 6 28.5 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Int Insul Main 4.1 54 0 8 0 432.0 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 33 6 8 0 268.0 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 ' 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall V Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.55 0.7 N 17.8 ft2 14 ft 4 in 0 ft 10 in None None 2 N 1 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 3 E 2 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 4 SE 3 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 5 S 4 Vinyl Low-E Double Yes 0.33 . 0.21 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 6 SW 5 Vinyl Low-E Double Yes 0.33 0.21 N 11.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 7 W 6 Vinyl Low-E Double Yes 0.33 0.23 N 48.6 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 591 ft2 591 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000363 1696.9 93.16 175.2 .1308 6.5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 28.2 kBtu/hr 1 sys#1 10/30/2020 3:57 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr 947 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ft2 Main 89 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Heating f X Jan f X Feb Venting Mar H Mar A r APr Jul rl Aug MaY Jun Jul AuSeP Ma X Jun rl Se Oct Oct Nov Nov HX Dec Dec H [ Jan [ Feb Mar [X] Apr [ May [ Jun JulAug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level 2. Single-family or multiple -family 2. Single-family a) Supply ducts R b) Return ducts R 6.0 6.0 3. No. of units (if multiple -family) 3. 1 c) AHU location Main 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 28.4 5. Is this a worst case? (yes/no) 5. ,No a) Split system SEER b) Single package SEER 15.0 6. Conditioned floor area (sq. ft.) 6. 1780 c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.352 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.272 14. Heating system: Capacity 28.2 c) Area 7c. 177.0 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 10. Wall type and insulation: b) Gas fired, natural gas EF c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 13.0 2. Masonry (Insulation R-value) 10132. 11. Ceiling type and insulation level 16. HVAC credits claimed (Performance Method) a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signat Date: Address of New Home: 8712 Merano Avenue City/FL Zip: Fort Pierce, FL 34951 10/30/2020 3:57:17 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1