HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 30 Block 1 Waterstone 1780 AGR
Builder Name: ADAMS HOMES
Street: 8712 Merano Avenue
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1513.4 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1245.40 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=13.0 268.00 ft2
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1900.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ft2
6. Conditioned floor area above grade (ft2) 1780
b. Knee Wall (Vented)
R=19.0 120.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
7. Windows(177.0 sqft.), Description Area
11. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 356
a. U-Factor: - Dbl, U=0.33 113.31 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 45.94 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.639 ft.
Area Weighted Average SHGC: 0.272
14. Hot water systems
8. Floor Types (1780.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ft2
b. Conservation features
EF: 0.940
b. N/A R=, ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 55.99
PASS
Total Baseline Loads: 56.40
I hereby certify that the plans fications covered
this calculation are in Flo '
Revi w of the plans and
Q-,TUE Sz4
comp n it a nergy
specifications covered by this��''
p
Code.
calculation indicates compliance
y �''�r = `VF
with the Florida Energy Code.
�o�
F• rrrn z, '�=`';;;� �';, O
PREPARED BY:
Before construction is completed
DATE: 1 n-3n-21170 ingnn KPnmany
this building will be inspected for
C? 1. y
we^
compliance with Section 553.908
*
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
4
with the Florida Enet q-G
G'pD WIS,
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
.� envelope leakage test report with envelope leakage no greater than 6.50 ACH50 (R402.4.1.2).
10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 IAIPI IT CI IIIAl1AADV r+uCf%W1 IL--- orEnr%n-v-
v..wI'L1..w I IXL.r Vn I
PROJECT
Title:
Lot 30 Block 1 Waterstone 17 Bedrooms: 3
Address Type:
Street Address
Building Type:
User
Conditioned Area: 1780
Lot #
30
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
8712 Merano Avenue
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce
Family Type:
Single-family
,
New/Existing:
New (From Plans)
FL , 34951
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
v Design
Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ftz ----
0.38 0 0.62
ROOF
/
Roof Gable Roof
Red Solar SA Emitt
Emitt Deck Pitch
V #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 1991 ftZ 446 ftZ Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ft' N - N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Knee Wall (Vented)
Main 19 Batt
120 ft2 0.11
Wood
2
Under Attic (Vented)
Main 30 Blown
1780 ftZ 0.11
Wood
10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 IMPI IT CI IURAAov rruCr%W1 10T ncnr%n-r
WALLS
Adjacent
A Ornt To INA1 Type
Space
Cavity Width
Et In
Height
Ef In
AreaR-Vahle
Sheathing Framing Solar Below
R-Value Fraction a o
1 N Exterior Concrete Block - Int Insul
Main
4.1 40 0
8 0
320.0 ft2
0
0 0.6
0
2 E Exterior Concrete Block - Int Insul
Main
4.1 40 6
8 0
324.0 ft2
0
0 0.6
0
3 SE Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
4 S Exterior Concrete Block - Int Insul
Main
4.1 11 10
9 6
112.4 ft2
0
0 0.6
0
5 SW Exterior Concrete Block - Int Insul
Main
4.1 3 0
9 6
28.5 ft2
0
0 0.6
0
6 W Exterior Concrete Block - Int Insul
Main
4.1 54 0
8 0
432.0 ft2
0
0 0.6
0
7 - Garage Frame - Wood
Main
13 33 6
8 0
268.0 ft2
0
0.23 0.01
0
DOORS
# Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 S Insulated Main
None
.25
3
6 8
20 ft2
2 - Wood Main
None
.25
2
' 8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed
orientation.
/ Wall
V
Overhang
# Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1 N 1 Metal Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in
0 ft 10 in
None
None
2 N 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
3 E 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
4 SE 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
5 S 4 Vinyl Low-E Double
Yes
0.33 . 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6 SW 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7 W 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 591 ft2 591 ft2
64 ft
8 ft
1
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000363
1696.9 93.16 175.2
.1308
6.5
HEATING SYSTEM
# System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
10/30/2020 3:57 PM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr 947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ----
---- Return ---- Air
CFM 25 CFM25
HVAC #
Location R-Value Area
Location
Area Leakage Type Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 356 ft2
Main
89 ft2 Default Leakage Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Heating f X Jan f X Feb
Venting
Mar
H Mar
A r
APr
Jul rl Aug
MaY Jun Jul AuSeP
Ma X Jun rl
Se
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
[ Jan [ Feb
Mar
[X]
Apr [
May [ Jun JulAug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6 7
8 9
10
11
12
Cooling (WD) AM
PM
78
80
78
80
78
78 78 78 78
78 80
80
80
80
78
78 78 78 78
78 78
78
78
78
Cooling (WEH) AM
PM
78
78
78
78
78
78 78 78 78
78 78
78
78
78
78
78 78 78 78
78 78
78
78
78
Heating (WD) AM
PM
66
68
66
68
66
68
66 66 68 68
68 68
68
68
68
68 68 68 68
68 68
68
66
66
Heating (WEH) AM
PM
66
68
66
68
66
68
66 66 68 68
68 68
68 68
68
68
68
68 68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft 0.3
Main
10/30/2020 3:57 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
2. Single-family or multiple -family
2. Single-family
a) Supply ducts R
b) Return ducts R
6.0
6.0
3. No. of units (if multiple -family)
3.
1
c) AHU location
Main
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
28.4
5. Is this a worst case? (yes/no)
5.
,No
a) Split system SEER
b) Single package SEER
15.0
6. Conditioned floor area (sq. ft.)
6.
1780
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.352
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.272
14. Heating system: Capacity
28.2
c) Area
7c.
177.0
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
10. Wall type and insulation:
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
13.0
2. Masonry (Insulation R-value)
10132.
11. Ceiling type and insulation level
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signat
Date:
Address of New Home: 8712 Merano Avenue City/FL Zip: Fort Pierce, FL 34951
10/30/2020 3:57:17 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1