BLOWER DOOR TE57 FORM
010use inn im'don TeSt Ceftll'HccltiM
PrescriptiVe abed Peirfoinsmante Method
r_^,j. -i l8 t_& C
PerWLit 0 2 `(` �1
Contractor: 0i e,� k ' N "
Job Address: 8 -) ay &ns ► -k.^ � .• e fz 3 If q g( —
Construction: ( V-T New Construction — core"plet.e i Eras�cjng — After Addillion
House infiltration Test Results 5LC Climate Zone 2
CFM (50) = i 3 s8Test Date`
Volume = t R 2 0 O
ACID (50) = CC-M (50) 3c 60 / Volume = 5 Mechanical Ventilation required less than 3 AC
Passing results must be am ACH (50) or less ( ass ( ) Fail
Foc, Energy
The building or dwelling unit shall be tested and verified as having an air leakage rate or' not exceeding 7 air changes per
hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through S. Testing shall be conducted with a
blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in
Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an
approved third party. A written report of the results of the test shall be signed by the pary conducting the test and
provided to the code official. Testing shall be per -formed at any time after creation of all penetrations of the building
thermal envelope.
!-'Bc, Residential
Where the air infiltration rate of a dwelling unit is less than 3 air changes per hour when tested with a blower door at a
pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservatior
the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3.
Testini; Compariv
Company Name: Pro -Duct Services
Address: '1915 Rio Vista Drive, Ft. Pierce, FL 3^A949
I hereby cerihlthat -the above House Infiltration results demonstrate compliance with FBC Energy Conservation
requirements in accordance with Section R402.4.1.2 Climate %one 2.
Signature:
Printed Name: Martin Klein
License/Certification #: 5061633