HomeMy WebLinkAboutVela Plansv v O O O E.Q. E.Q. 12'-10" Meld verify TYPICAL SPACING AT SIDES T EXISTING CBS I ap- M I I&MIM�wo Strap studs to PT frame using Simpson H2.5 strap with (10) 8d nails in each strap Existing lintel or beam to remain 2" x 4" top plate Frame in existing oening with 2" x 8" studs at IV o.c. Tapcon 2" x 8" PT wood framing around perimeter of — opening and attach using (2) 1/4" x 3" tapocns as shown rn Strap studs to PT frame using X Simpson H2.5 strap with (10) 8d w nails in each strap Nail 5/8" CDX plywood to exterior :!E�side of opening using lod ring shank V field New base -board nails at o.c. and edges. Finish with stucco to match existing to match existing profile OF"ENING FRAME —IN DETAIL Scale: 1/2" = I'-O" Strap new studs to exist plate using Simpson H2.5 Strap at each stud to F 2" x 8" studs with R-19 batts insulation between each Tapcon bucks to wall using IICi III -IN - Grout sid solid Ias needed for windowI xlsting BS wall \to remz(in Tappcon bucks to wall using 114" dia. x 3" tapcons at 12" o.c. 8" from corners NEW WINDOW IN EXISTING OFENING DETAIL Scale: 1/2" = 1'-0" 5/8" drywall ceiling on truss bottom cord 1/2" drywall on 2" x 4' studs at 14" o.c. Finish to match existing 2" x 4" P.T. bottom plate existing slab Interior Non —Bearing Partition Scale: 1/2" = I'-O" 1/8" thick light textured stucco on plastic lath over house wrap on 19/32" CDX plywood nailed 6" o.c. in field and on edges w/ 10d ring shank nails. Color t Texture to Match Existing Digitally signed by Daniel R. Braden Date: 2020.12.03 19:17:38-05'00' 11 1 1 LI Q LLI (V -- [i� m . Q3 �O z >00m ON 0 _ (14 (14U dD OD E o� I I 0CID 00(a Q3 UO (V (V # 2 Q I NUrr�07 � ilJ Qui m t U� X < E U- I Q, a-+ L L 4--) W Sheet 3. OF 1. Comm 20-21-4 4" concret 6"x6" 1#10/10 clean comp Dowel I existing RE50C for slab resistan clean compacted termite treated fill Field Verify 12'-10" Footing sch&dUl& Mark Size and Description T-12 Thicken slab edge to 12"w x 8"d with (2) 45 bar cont. W'w x W'd concrete monolithic and #5 transverse bars at 32" footin with (2) o.c. bottom) #5 rebar continuous F-2.4 2.4"w x and #5 W'd concrete monolithic transverse bars at 32" footing with (3) o.c. (bottom) 1*5 rebar continuous Thicken edge to 12"w x 8"d with concrete and (2) 45 bar continuous 4" concrete slab with fibermesh OR 6"x6" 410/10 WWM on 10 mil Visqueen over clean compacted termite treated fill 12" T-12 FOOTING DETAIL #5 bar vert. w/ 30" overlap - at each filled cell SCALE 1/2" = I'-O" EE TYPICAL SECTIONS �N��o-0 I N �0_��I U� =—oQZ-Q 1" concrete slab with fibermesh OR I" recess for Cx6" #10/10 WWM on 10 mil Visqueen over waterproofing at slab clean compacted termite treated fill Poo Grade N E _ W'w x W'd concrete monolithic m —L; U —� footing with (2) 45 bars cont. and #5 transverse bars at 32" o.c. — # 3 W" 0 U- F-I� FOOTING DETAIL SCALE 1/2" = I'-O" W �o �U � o=3 #5 bar vert. w/ 30" overlap SEE TYPICAL ECTIONS at each filled cell TO 4" concrete slab with fibermesh OR I" recess for 6"x6" 1*10/10 WWM on 10 mil Visqueen over waterproofing at slab clean compacted termite treated fill _ m Ills— 9jO 24 w x 16 d concrete monolithic m footing with (3) 45 bars Cont. X V� � O 2 N N u and # transverse bars at 32" o.c. U C oD OD E 3 2 4„ 3„ p- 11,3 00 it Q3 i O CV CV Q to —.Kj - F 2-4 FOOTING DETAIL ulllrr �� SCALE I/2" = I'-O" Q!(6 ` M U� X (Q� FOUND,4TION LAN Q ELL ~'mowL Q3 to FOUNDATION NOTES: SCALE: I/�f" = 1'-O" 1. Any changes to plans must be submitted to the architect for approval prior fa to proceeding with construction. 2. Contractor shall be responsible for verification of all notation and dimensions prior to start of construction. 3. ALL Concrete used for slabs shall be 2,500 PSI concrete min., and ALL Concrete used for vertical filled cells, continuous. tie beams etc.. shall be 3,000 P.S.I. concrete and/or -4,000 F.S.I. grout mix min. 4. Soil bearing capacity assumed to be 2500 psf and stable. This shall be confirmed in writing by soil testing report done by others prior to the start of any construction S. Verif g all recess thickness at shower floors, all floor finishes as selected by owner, door sills � thresholds including pocket SCUD frame widths etc... prior to placing any slabs. �. Contractor to provide for Form Board Survey - Form Board Survey Sheet to be provided to Truss Company prior to truss construction 1. ALL Reinforcing steel shall be grade �0, meeting ASTM A-I� and 114. A-35 specifications. ALL Anchors to be A-301 steel. 8. Provide a minimum of 3" concrete protection at footings and OF 1. Comm 1* 1-1/2" concrete protection at beams for ALL reinforcing bars. 9. Contractor to provide the Architect with truss shop drawings including 2 0 — 21-4 ALL truss cut sheets showing ALL truss reactions prior to START OF FOUNDATION WORK for strap and footing size verification. oo�U�Q........o o\ Digitally signed ®ofL R. BRA by Daniel R. o 0 ° ° Braden AR 977® cQ Date: 2020.12.03 �°0°°°°°° 19:17:24-05'00' Additional 45 bars Lintel Bar Clear "A _ Length Length Span Bars Bars COVER V111:3 2'-10" 2'-8" 1'-6"2,#3 none Precast Lintel 3'-6" 3'-4" 2'-2" 2,#3 none 8F8-OB/IT Additional 4'-0" 3'-10" 2'-8" 2,43 none 2k5 bars CLEAR 4'-6" 4'-4" 3'-2" 2,#3 none COVER One Row of Beam 5'-2" 4'-0" 2,43 none Block Above 2,#4 none ' Precast Lintel ' '" 5'-4" 2,#4 none \ J. J i i Additional i i �'-6" �'-0" 6'-2" 2,US none CLEAR M ----y #S bars '`-----'w COVER 8FI6-IBAT 8FI6-IB/2T none NOTES: ALL reinforcing steel is grade 60. I. MIN. COVERAGE OF STEEL = 1.5" 2. MIN. BEARING REQUIRED 9 EA. END = 4" 3. STANDARD FOR REINF. STEEL = ASTM A615 GRADE 60 TYPICAL LINTEL SECTION ( PRECAST CONCRETE ) LINTEL SCHEDULE Window Pre- Rows of Max. Max. Max. Mark or Door Unit Lintel Cast -Crete Stressed BM Block Above Bottom Top Gravity Load Uplift Load Lateral Load Width Size Specification Steel Size Steel Size (PLF) (PLF) (PLF) L20 2'-0" 2'-10" 8F8-OB/IT NO 1 u5 3069 1569 1642 — 2'-2" L31 2'-6" V-9" 8F8-OB/IT NO — 1 u5 2561 1363 -163 2'-8" 3'-1" L45 4'-S" 5'-l" 8F8-OB/IT NO — 1 u5 13,49 1016 411 L50 5'-0" 5'-8" 8F8-OB/IT NO — 1 u5 1106 909 339 L60 6'-8" 6'-8" 8F8-OB/IT NO — 1 u5 1 1011 12-1 5314 L-10 T-O" T-O" 8F8-OB/IT NO — I u5 1011 12-1 5314 L80 8'-0" 8'-8" 8F8-OB/IT NO — 1 u5 699 591 1 512 L90 9'-0" 9'-8" 8F8-OB/IT NO — 1 u5 535 530 401 - ALL LINTELS SHALL BE MADE BY CAST-CRETE. - LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE - REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ. REQUIREMENTS - LINTELS OVER 13'-11" LONG ARE TO BE PRESTRESSED. - CONTRACTOR TO VERIFY ALL LINTEL SIZES BASED ON FINAL MASONRY OPENING SIZES AND ADJUST LINTELS ACCORDINGLY PRIOR TO ORDERING ANY/ALL LINTELS 2" x 6" PT wood secured with 1/2"dia. x 6" expansion anchors with 2" sq, washer at 18" O.C. overhead door track secured to wood jamb per manufacturer's product approval ALL GARAGE DOORS AS SPECIFIED IN PRODUCT APPROVAL ON THESE PLANS. DOORS TO MEET WIND PRESSURE STATED IN PERMIT INFO BOX ON THESE PLANS Garage Door Jamb Detail NTS Tip. 1"Iascnrq Flll&d Cell Detail NTS S E 4 M SCHEDULE Mark Size and Description B1 Two rows of beam block filled with concrete and (1) #5 bar continuous in each row. Provide precast lintel filled with concrete and (1) #5 bar per lintel schedule continuous over openings. J , Illed Cells (Typical) 1/2"x -4 1/2" isonry Inspection Clean Out Hole O° bend from footing 8 bar dia. lap in wall Id footing Dowel (1) 45 bar w/ 25" min lap and 6" embed ete Footing nts Filled Cell Masonry Column with One 45 From Footing To Beam Each. Conc. Fill To Be 3000 PSI See Floor Plan For Location Double Filled Cell Column NTS Filled Cell Masonry Column with One 45 From Footing To Beam. Conc. Fill To Be 3000 PSI See Floor Plan For Location Single Filled Cell Column NTS Ex Int Verify all stucco banding and trim per elevations Stucco return Attach door to block wall with 1/4" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c, max from each corner thru I" x 8" PT Buck See door schedule and floor plan for size and locations install door per product approval bg mfg Drywall return See typical wall sections for interior drywall finish notes verify filled cell count per floor plans at window jambs Exterior Door Jamb Detail NTS Seal ALL concrete block jambs prior to buck per F S C R703.8 using any approved sealant VERIFY ALL SILL MATERIAL WITH OWNER PRIOR TO ORDERING VERIFY ALL ROUGH OPENING SIZES WITH THEIR RESPECTIVE MANUFACTURER PRIOR TO INSTALLING MASONRY Entegra Bermuda Flat Roof Tile installed per product approval FLU 1804.2 and evaluation report using (2) IOd ring shank nails over ppolyglass self adhered roofing underlayment over 19/32" CDX plywood attached to trusses per sheeting attachment diagram on roof plan. Simpson HETA 20 or equal hurricane anchor at each truss 12 with (10) IOd x 1 1/2" nails ( 24" o.c.) supporting Max. \ 6 SLOPE 1810lbs, uplift Galt' -Alum Metal drip on 1" x 4" Drip on _ I" x 8" Fascia on 2" x 6" Sub -Fascia 24„ 5/8" thick stucco on 3/8" hi -rib lath attached to horizontal and vertical wood framing with nails or staples to provide no less than I-3/4" penetration into horizontal wood framing and 3/4" penetration into vertical wood framing members 5/8" thick light textured stucco on typical concrete block construction #5 bar vert. w/ 30" overlap — at each filled cell I" Block recess for waterproofing at slab (Optional) Grade � � "M��� � rH M-7�� rH TYPICAL SECTION R-22 Spray Foam Insulation Drywall return Sill - verify material and s with owner pri to ordering PRE-ENGINEERED TRUSSES at 24"o.c. TYPICAL ( shop drawings by manufacturer ) 5/8" drywall w/ smooth finish I� Ex Int Window Jamb Detail Verify all stucco banding and trim per elevations Stucco return Attach window to block wall with 1/4" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c. max from each corner thru I" x 4" PT Buck See window schedule and floor plan for size and locations install window per product approval by mfg Drywall return See typical wall sections for interior drywall finish notes verify filled cell count per floor plans at window jambs NTS Lintel - see plans for size and steel req. Attach window to block wall with 1/4" dia. x 3" tap -cons with min. 1 1/2" penetration at 12" o.c. max and 6" o.c. max from each corner thru I" x 4" PT Buck stucco return See window schedule and floor plan for size and locations Stucco finish over sill slope for drainage Pour concrete sill over tin cap Section Window Head Sill 1/2" drywall over I" x furring strips at 16" o.c, with R-4.Z fyfoil insulation on typical 8" Block walls All drywall is per FBC 102.3.1 and shall meet all pertaining ASTM codes. Mortar to be Type "M" only. Provide Dur-O-Rock at all wet O areas (ex, showers, tubs etc...) O Fill cell with concrete and (1) 45 bar vert. (typical). Max, spacing shall not exceed 32" unless otherwise noted see foundation plan notes for spacing at openings Typical 4" concrete slab with fibermesh OR Baseboard 6"x6" 410/10 WWM on 6 mil Visqueen over clean compacted termite treated fill I_I I —III 1=1 I�I I —III 1= Illlllll—ii�= F-16 SCALE 1/2" = 1'-0" NTS 30" m1n. Corner Steel Lap nts Digitally signed by Daniel R. Braden Date: 2020.12.03 19:16:55-05'00' �11 m gio _ �>ODmN C � dD OD ca E ° I I OD M Urr N �07 ilJ Quiwrr�� m U� X (� �< n l(Q E U- Q, w L L � Sheet D1 OF 1. Comm # 20-21-4