GENERAL NOTES:
1. THE CONDUCTOR SHALL BE RESPONSIBLE FOR VERIFYING All EXISTING CONDITIONS.
2. THE CONTW.CTOR SHALL BE RESPONSIBLE FOR COORDINATING ARCHITECTURAL, STRUCTURAL NECHPNICN. AND
ELECTRICAL DETAIL AM DIMENSIONS. ANY DISCREPANCIES BETWEEN SUCH DETAILS AND DIMENSIONS SHALL BE
REPORTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION PROCEDURE AND SEQUENCE TO INSURE THE
INTEGRITY OF THE BUILDING AND ITS COMPONENT PARTS WRING CONSTRUCTION.
4. THESE PLANS HAVE BEEN PREPARED PER REGULATIONS QU THE 2017 FLORIDA BURRING CODE. THE WORK OF
ALL CONTRACTORS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH N THE AFOREMENRONED CODE NO
DEVIATIONS FROM THE WORK SHOWN OR REASONABLY IMPLIED SHALL BE UNDERTAKEN WITHOUT THE ENGINEERS
WRITTEN CONSENT - A COPY OF WHICH WILL BE FILLED WITH THE CONSTRUCTION OFFICIAL
5. ANY CHANGES TO OR DEVIATIONS FROM THESE DRAWINGS SHALL NOT BE MADE WITHOUT WRITTEN CONSENT
FROM THE ENGINEER.
6. THESE DRAWINGS ARE THE PROPERTY OF THE ENGINEER AND SHALL NOT BE USED WITHOUT HIS CONSENT.
DRAWINGS SHALL NOT BE USED FOR ISSUE OF BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE
ENGINEER.
7. THE OWNER AND CONTRACTOR SHALL HOLD HARMLESS THE ENGINEER FROM AND A,GA94ST ALL ABILITY CLAIMS,
DAMAGES, LOSSES AND EXPENSES INCLUDING LEGAL FEES ARISING OUT OF OR RESULTING FROM ERRORS OR
OMISSIONS IN THE PERFORMANCE OF THE WORK BY THE CONTRACTOR. ALL WORK AND MATERIAL SHALL MEET
THE REQUIREMENTS OF ALL LOCAL AND STATE BUILDING CODES. THE DRAWN SHOW THE GENERAL
ARRANGEMENTS AND EXTENT QU THE WORK. AS THE WORK PROGRESSES , THE OWNER AND THE CON[MCIOR,
AT NO DORA COSTS, SAW. MARE MODIFICATIONS TO MAKE THE PARTS ALIGN.
8. CONTRACTORS SHALL CHECK AND VERIFY ALL PLAN DIMENSIONS AND CONDITIONS BEFORE PROCEEDING
CONSTRUCTION- HE SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER FOR CORRECTION PRIOR TO
BEGINNING ANY WORK. THE DISCOVERY OF DISCREPANCIES AFTER THE BEGINNING OF WORK WILL BE EVIDENCE
OF FAULTY WORK AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. DO NOT SCALE DRAWINGS. ALL
WRITTEN DIMENSIONS GOVERN,
9. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND LABOR REQUIRED TO COMPLETE THE
TOTAL PROJECT. THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL MATERIALS, TOOLS, EQUIPMENT, LABOR,
MACHINERY. TRANSPORTAIKRN, FEAT, WATER UTILITIES, AND ALL OTHER FACILITIES AND SERVICES REQUIRED FOR
THE SAFE AND PROPER DWAON AND COMPLETION OF THE WORN. THE ENGINEER SHALL BE THE
INTERPRETER OF THE CONTRACT OOCUMEHIS,
10. THE DOCUMENTS SHOWN AN OVERVIEW OF Tiff WORK REQUIRED UNDER THIS CONTRACT AND RELATE)
REQUIREMENTS AND CONDITIONS THAT WILL IMPACT THE PROJECT. ALL DRAWINGS ARE COMPLIMENTARY. THE
DRAWINGS GENERALLY SHOW THE INTENT OF THE OVERALL COMPLDOIY AND CONCEPTS OF THE PROJECT, AND
DO NOT NECESSARILY SHOW ALL DETAILS AND CONDITIONS.
11. ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTING SHALL HAVE SOLID POISONING
UNDER NEW WORK AND SHALL BE INSTALLED BY A UCENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED
IN ACCORDANCE WITH ALL STATE AND DEPARTMENT OF AGRICULTURE, STRUCTURAL PEST CONTROL DIVISION
REGULATIONS. RULES. DEFINITIONS AND REQUIREMENTS.
12. THE CONTRACTOR SHN.L BE RESPONSIBLE FOR VERIFYING AND MAINTAINING ALL EOTNG SETBACKS, EASEMENTS,
AND ANY DEED RESTRICTIONS.
13. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CLEANUP AND SHALL INCLUDE THE SUE, AND
THE BURRING. THE ENTIRE PROW SHALL HE LEFT N A NEW, CLEW CONDITION. -
WIND CHART WIND LOAD MAIN WIND FORCE PRESSURE DIAGRAMS
" . " - Mo..:
P11
ULTIMATE DEMON WIND FNNIRE CATEGORY
BP�OBT Vun FOFIQUIR CATEODRY IBULLDBgBAND OTHER STRUCTURES
FLORIDA BUW.DMO CORE-BUILOING, @H EDITION (2077)
SHEET LIST
SHEET NUMBER
SHEET TITLE
C-1
COVER SHEET, WIND LOADING
DIAGRAMS & MWFRS TABLE
A-1
ANCHORING DETAILS &
SCHEDULES
A-2
ANCHORING SPEC SHEETS
MWFRS 180 MPH EXP. "C"
ZONE
TABLE
P ES SSUREt
ADJUSTMENT
FACTO
LOAD
COMBINATION
FACTOR -
WORKING
PRESSURE
PSf
A
51.0
1.21
0.6
37.2
B
-16.9
1.21
0.6
-12.3
E
-48.8
1.21
0.6
-35.6
F
-31.9
1.21
0.6
-23.2
1. SEE FIGURE 28.6-1 PAGE 3D3-3D5 IN ASCE 7-10.
2. SEE FIGURE 28.6-1 PAGE 305 IN ASCE 7-10.
3. SEE SECTION 2.4.1 IN ASCE 7-10.
4. DESIGN PRESSURES SHOWN ARE BASED ON WORST CASE DEIGN CONDITIONS OF
AREA FOR APPROVAL STAMPS
Donald
Van
Gerve
Digitally signed
by Donald Van
Gerve
Date: 2018.05.15
06:33:40-041001
OCALA FLORIDA SHOP
DBA FLORA-BAMA MFG
3082 NE 24TH STREET
OCALA FL 34470
PROJECT.-
ANCHORING FOR SHEDS
COVER SHEET & GENERAL NOTES
DON VAN RAL P.E.
SESPECIALLY STRUCTURAL ENGINEER
978-943-6869
ALTERNATE DESIGN SOLUTIONS
UDS SIAll TURRE NIEUWI)BBIfiNRCONSIEIMIC,
PHONE 215.355.4684
WWW.ALTERNATEDESIGNSOLUTONSCOM
ENGINEERING SERVICES PROV/0E0 FOR.
PREMIER PORTABLE BUILDINGS
317 EAST STATE LINE ROAD
SOUTH FULTON, TN 38257
WWW.PREMIERBUILDINGS.US
BUILDING FOR WIND VELOCITIES PER 2017 F.B.C.
REVISION DESCRIPTION
I
z
3
4
5
DATE: 4.30.18
PROJECT NO.: 17164
DRAWING BY: JH
/f CHK BY: DVG
Og'S c>1 DWG NO.:
REVIEWED FOR C-1
CODE COMPLIANCE
ST. LUCIE COUNTY -
BOCC
1 of 3�
I zm to
No 61517
¢/3qVs
STATE OF
�I�
WOOD W/ SHED WALL
if; STFEE CABLE W/ (2)
X,7 STAINLESS CLAMPS
FINISH GRADE
OPTIONAL STABILIZER PLATE
REFER TO NOTE ON GROUND
ANCHOR SCHEDULE ON SHEET
A-1 FOR REQUIREMENTS
SEE GROUND ANCHOR SCHEDULE
ON SHEET A-1 FOR ANCHOR
SPECIFICATIONS
WOOD W/ SLED WALL
STEEL EYEBOLT ZINC:
%x6 (TABLE ON A-1) OR
j i4°x6 (TABLE ON A-1)
Ki
6° FRAME CLAMP W/ GAUVA M
M4X. SRMP IYx"xB35MIN. CENT. TO
ASTM 0-3953 ANSI 225.11
P.T. SKID FINISH GRADE
BOLT (SEE SPEC SHEET)
OPTIONAL 16°06°x4° OR (2)
_ 8°x16k4° SOLID CAP BLOCKS
REFER TO SCHEDULE SHEET A-1
M9TM'
1. REFER TO NOTES GROUND ANCHOR SCHEDULE ON
SHEET A-1 FOR RE OF STABILIZER PLATES.
2. REFER TO GROUND ANCHOR SCHEDULE ON SHEET A-1
FOR ANCHOR DESCRIPTIONS AND SOIL USE
CLASSIFICATIONS.
3. ANCHOR MUST BE PLACED AT EACH CORNER A MOMUM
OF 6" FROM THE CORNER.
HELIX ANCHOR DETAIL
A-1 SCALE: 1-1/2°=I'-0"
SHEARWALL ANCHOR TO BE
PLACED HERE (".)
SW-1
16°x16°x4° DOING. PAD OR (2)
8°xi6°x4° WK. PADS (TYP.)
SEE 1/A-i FOR ADD'L INFORMATION
2 OPTIONAL ANCHOR DETAIL
A—i SCALE: 1-1/2'4-0"
114ffi:
4 1. CONCRETE PADS ARE OPTONAL.
A-T 2. DIMENSIONS SHOWN ARE NOMINAL
S. ANCHORS ARE REQUIRED MIN. (4) PER
BUILDING, (1) 0 EACH CORNER SHEARWALL
3 FLOOR FRAMING PLAN REFER .
4. ANCHOR
TO ACNG1AES n SLEET L) L FOR
A-1 SCALE: 1/4°=1'-0" (00 NOT SCALE DRAWING) ANCHOR SPACING & OPDOWL PAD LOCATION.
5. SPACE OPTIONAL PADS EQUALLY.
GROUND ANCHOR SCHEDULE
MODEL I
PART
DESCRIPTION
SOIL
GLASS
M12H5/8
59080 / 59081
48" x %" ROD w/ (1) 6" HELIX
4A
M12H3/4
59085 / 59094
48" x %4" ROD w/ (1) 6" HELIX
4A
M1423/4
59128
42" x Y4" ROD w/ (2) 4" HELIX
4A
M1483/4
59086
48" x X" ROD w/ (2) 4" HELIX
4A
M121164
59250
36' x N4" ROD w/ (1) 4" HEDX & (1) 6" HELIX
4A
N/A
59065
EYE ANCHOR — 48" X %" w/ (1) 6" HELIX
4A
N/A
59045
EYE ANCHOR — 48" X Y4" w/ (1) 6" HELIX
4A
M607
59099
60" X Y4" w/ (1) 7" HELIX
48
N/A
59040
EYE ANCHOR 60" X %4" w/ (1) 8" HELIX
4B
OPTIONAL PAD SCHEDULE FOR ALL WIND SPEEDS AND EXPOSURES
BUILDING WIDTH
NUMBER OF PADS BY LENGTH UNDER EACH SKID
10'-0"
12'-0"
14'-0"
16'-0"
18'-01,
20'-0"
22'-0"
24'-O"
26'-0"
28'-0"
30'-0"
32'-0"
34'-0"
36'-0"
38'-0"
8'-0"
3
3
3
3
3
4
4
4
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10'-0"
3
3
3
4
4
4
4
5
5
5
5
N/A
N/A
N/A
N/A
N/A
1 V-2"
2
2
3
3
3
3
3
3
3
4
4
4
N/A
N/A
N/A
N/A
12'-0"
2
2
3
3
3
3
3
3
4
4
4
4
4
4
N/A
N/A
14'-0"
2
3
3
3
3
3
3
4
4
4
4
4
4
5
5
5
16'-0"
2
3
3
3
3
3
3
4
4
4
4
4
5
5
5
5
ANCHORING FOR 180 mph, WIND SPEED, EXPOSURE "C" - 318" ANCHOR BOLT
BUILDING
NUMBER OF ANCHORS EACH SIDE WALL
WIDTH
MAX'
SPACING
OVERTURN
10,-0"
12'-0"
14'-0"
16'-0"
18,-0"
20'-0"
22'-0"
24'-0"
26'-0"
28'-0"
30'-0"
32'-0"
34'-0"
36'-0"
38'-0"
8'-0"
3.15
5
5
6
7
7
8
8
9
10
10
11
12
12
13
14
14
10'-0"
3
5
6
6
7
8
8
9
10
10
11
12
12
13
14
14
15
11'-2"
3.98
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12'-0"
4.01
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
14'—O"
4.10
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
16'-0"
4.18
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
ANCHORING FOR 180 mph WIND SPEED, EXPOSURE "C" - 518" ANCHOR BOLT
BUILDING
NUMBER OF ANCHORS EACH SIDE WALL
WIDTH
MAX'
SPACING
OVERTURN
10'-0"
12'-0"
14'-0"
16'-0"
18'-0"
20'-0"
22'-0"
24'-0"
26'-0"
28'-0"
30'-0"
32'-0"
34'-0"
36'-0"
38'-0"
40'-0"
8'-0'
4.61
4
4
5
5
5
6
6
7
7
8
8
8
9
9
10
10
10'-0"
4.30
4
4
5
5
6
6
7
7
8
8
8
9
9
10
10
11
1 V-2"
5.84
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
12'-0"
5.88
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
14'—O"
6.01
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
16,-0"
6.13
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
16x16x4 NOMINAL PAD
(2) ex8x4 NOMINAL PADS
4 PAD DETAILS
A—i SCALE: 1-1/2"=1'-O"
SKID PROJECT -
ANCHORING FOR SHEDS
FASTENING SCHEDULE / WIND LOADING
DON VAN GERVE, P.E.
SPECIALTY STRUCTURAL ENGINEER
978-943-6869
ALTERNATE DESIGN SOLUTIONS
sreumRaLENNRFRIIxD oESWN6mnsTMLenaNsmu�s
PHONE 215.355.4684
WWW.ALTEWNATEDESIONSOLUTIONS.COM
ENGINEERING SERVICES PROVIDED FOR.
PREMIER PORTABLE BUILDINGS
317 EAST STATE LINE ROAD
SOUTH FULTON, TN 38257
WWW.PREMIERBUILDINGS.US
REVISION DESCRIPTION DATE BY
DATE: 4.30.18
PROJECT NO.: 17164
DRAWING BY: JH
CHK BY: DVG
DWG NO.:
VAN •.
"
Ot No 61517
* 4/3Q18
E¢;
'9T, STATE OF
'P
���ixSAONAk-��`x�
2of3
OCALA FLORIDA SHOP
DBA FLORA-BAMA MFG
3082 NE 24TH STREF_T
OCALA FL 34470
PROJECT -
ANCHORING FOR SHEDS
PRODUCT CUT SHEETS
DON VAN CT RAL P.E.
SPECIALTY STRUCTURAL ENGINEER
010 nAz cocn
ALTERNATE DESIGN SOLUTIONS
EINOCIDNAtENNINHWN6 MR
PHONE: 215.&%4684
WWW.ALTERNATEDESIGNSOLUTIONS.COM
LNUMUKIM )tKVAGLJ MMULu FOR.•
PREMIER PORTABLE BUILDINGS
317 EAST STATE LINE ROAD
SOUTH FULTON, TN 38257
WWW. PREM IERBUILDINGS. US
DATE: 4.30.18
PROJECT NO.: 17164
DRAWING BY: JH
CHK BY: DVG
DWG NO.:
A-2
3of3