HomeMy WebLinkAboutBuilding Plans; Anchoring for ShedsPREMIER PORTABLE BUILDINGS S T A T E O F L 0 R I D A ( 1 8 0 M P H) W I N D S GENERAL NOTES: 1. THE CONDUCTOR SHALL BE RESPONSIBLE FOR VERIFYING All EXISTING CONDITIONS. 2. THE CONTW.CTOR SHALL BE RESPONSIBLE FOR COORDINATING ARCHITECTURAL, STRUCTURAL NECHPNICN. AND ELECTRICAL DETAIL AM DIMENSIONS. ANY DISCREPANCIES BETWEEN SUCH DETAILS AND DIMENSIONS SHALL BE REPORTED TO THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ERECTION PROCEDURE AND SEQUENCE TO INSURE THE INTEGRITY OF THE BUILDING AND ITS COMPONENT PARTS WRING CONSTRUCTION. 4. THESE PLANS HAVE BEEN PREPARED PER REGULATIONS QU THE 2017 FLORIDA BURRING CODE. THE WORK OF ALL CONTRACTORS SHALL COMPLY WITH THE REQUIREMENTS SET FORTH N THE AFOREMENRONED CODE NO DEVIATIONS FROM THE WORK SHOWN OR REASONABLY IMPLIED SHALL BE UNDERTAKEN WITHOUT THE ENGINEERS WRITTEN CONSENT - A COPY OF WHICH WILL BE FILLED WITH THE CONSTRUCTION OFFICIAL 5. ANY CHANGES TO OR DEVIATIONS FROM THESE DRAWINGS SHALL NOT BE MADE WITHOUT WRITTEN CONSENT FROM THE ENGINEER. 6. THESE DRAWINGS ARE THE PROPERTY OF THE ENGINEER AND SHALL NOT BE USED WITHOUT HIS CONSENT. DRAWINGS SHALL NOT BE USED FOR ISSUE OF BUILDING PERMIT UNLESS SIGNED AND SEALED BY THE ENGINEER. 7. THE OWNER AND CONTRACTOR SHALL HOLD HARMLESS THE ENGINEER FROM AND A,GA94ST ALL ABILITY CLAIMS, DAMAGES, LOSSES AND EXPENSES INCLUDING LEGAL FEES ARISING OUT OF OR RESULTING FROM ERRORS OR OMISSIONS IN THE PERFORMANCE OF THE WORK BY THE CONTRACTOR. ALL WORK AND MATERIAL SHALL MEET THE REQUIREMENTS OF ALL LOCAL AND STATE BUILDING CODES. THE DRAWN SHOW THE GENERAL ARRANGEMENTS AND EXTENT QU THE WORK. AS THE WORK PROGRESSES , THE OWNER AND THE CON[MCIOR, AT NO DORA COSTS, SAW. MARE MODIFICATIONS TO MAKE THE PARTS ALIGN. 8. CONTRACTORS SHALL CHECK AND VERIFY ALL PLAN DIMENSIONS AND CONDITIONS BEFORE PROCEEDING CONSTRUCTION- HE SHALL REPORT ANY DISCREPANCIES TO THE ENGINEER FOR CORRECTION PRIOR TO BEGINNING ANY WORK. THE DISCOVERY OF DISCREPANCIES AFTER THE BEGINNING OF WORK WILL BE EVIDENCE OF FAULTY WORK AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. DO NOT SCALE DRAWINGS. ALL WRITTEN DIMENSIONS GOVERN, 9. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND LABOR REQUIRED TO COMPLETE THE TOTAL PROJECT. THE CONTRACTOR SHALL FURNISH AND PAY FOR ALL MATERIALS, TOOLS, EQUIPMENT, LABOR, MACHINERY. TRANSPORTAIKRN, FEAT, WATER UTILITIES, AND ALL OTHER FACILITIES AND SERVICES REQUIRED FOR THE SAFE AND PROPER DWAON AND COMPLETION OF THE WORN. THE ENGINEER SHALL BE THE INTERPRETER OF THE CONTRACT OOCUMEHIS, 10. THE DOCUMENTS SHOWN AN OVERVIEW OF Tiff WORK REQUIRED UNDER THIS CONTRACT AND RELATE) REQUIREMENTS AND CONDITIONS THAT WILL IMPACT THE PROJECT. ALL DRAWINGS ARE COMPLIMENTARY. THE DRAWINGS GENERALLY SHOW THE INTENT OF THE OVERALL COMPLDOIY AND CONCEPTS OF THE PROJECT, AND DO NOT NECESSARILY SHOW ALL DETAILS AND CONDITIONS. 11. ALL NEW INTERIOR CONCRETE SLABS AND FOUNDATION WALLS AND FOOTING SHALL HAVE SOLID POISONING UNDER NEW WORK AND SHALL BE INSTALLED BY A UCENSED CONTRACTOR. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL STATE AND DEPARTMENT OF AGRICULTURE, STRUCTURAL PEST CONTROL DIVISION REGULATIONS. RULES. DEFINITIONS AND REQUIREMENTS. 12. THE CONTRACTOR SHN.L BE RESPONSIBLE FOR VERIFYING AND MAINTAINING ALL EOTNG SETBACKS, EASEMENTS, AND ANY DEED RESTRICTIONS. 13. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CLEANUP AND SHALL INCLUDE THE SUE, AND THE BURRING. THE ENTIRE PROW SHALL HE LEFT N A NEW, CLEW CONDITION. - WIND CHART WIND LOAD MAIN WIND FORCE PRESSURE DIAGRAMS " . " - Mo..: P11 ULTIMATE DEMON WIND FNNIRE CATEGORY BP�OBT Vun FOFIQUIR CATEODRY IBULLDBgBAND OTHER STRUCTURES FLORIDA BUW.DMO CORE-BUILOING, @H EDITION (2077) SHEET LIST SHEET NUMBER SHEET TITLE C-1 COVER SHEET, WIND LOADING DIAGRAMS & MWFRS TABLE A-1 ANCHORING DETAILS & SCHEDULES A-2 ANCHORING SPEC SHEETS MWFRS 180 MPH EXP. "C" ZONE TABLE P ES SSUREt ADJUSTMENT FACTO LOAD COMBINATION FACTOR - WORKING PRESSURE PSf A 51.0 1.21 0.6 37.2 B -16.9 1.21 0.6 -12.3 E -48.8 1.21 0.6 -35.6 F -31.9 1.21 0.6 -23.2 1. SEE FIGURE 28.6-1 PAGE 3D3-3D5 IN ASCE 7-10. 2. SEE FIGURE 28.6-1 PAGE 305 IN ASCE 7-10. 3. SEE SECTION 2.4.1 IN ASCE 7-10. 4. DESIGN PRESSURES SHOWN ARE BASED ON WORST CASE DEIGN CONDITIONS OF AREA FOR APPROVAL STAMPS Donald Van Gerve Digitally signed by Donald Van Gerve Date: 2018.05.15 06:33:40-041001 OCALA FLORIDA SHOP DBA FLORA-BAMA MFG 3082 NE 24TH STREET OCALA FL 34470 PROJECT.- ANCHORING FOR SHEDS COVER SHEET & GENERAL NOTES DON VAN RAL P.E. SESPECIALLY STRUCTURAL ENGINEER 978-943-6869 ALTERNATE DESIGN SOLUTIONS UDS SIAll TURRE NIEUWI)BBIfiNRCONSIEIMIC, PHONE 215.355.4684 WWW.ALTERNATEDESIGNSOLUTONSCOM ENGINEERING SERVICES PROV/0E0 FOR. PREMIER PORTABLE BUILDINGS 317 EAST STATE LINE ROAD SOUTH FULTON, TN 38257 WWW.PREMIERBUILDINGS.US BUILDING FOR WIND VELOCITIES PER 2017 F.B.C. REVISION DESCRIPTION I z 3 4 5 DATE: 4.30.18 PROJECT NO.: 17164 DRAWING BY: JH /f CHK BY: DVG Og'S c>1 DWG NO.: REVIEWED FOR C-1 CODE COMPLIANCE ST. LUCIE COUNTY - BOCC 1 of 3� I zm to No 61517 ¢/3qVs STATE OF �I� WOOD W/ SHED WALL if; STFEE CABLE W/ (2) X,7 STAINLESS CLAMPS FINISH GRADE OPTIONAL STABILIZER PLATE REFER TO NOTE ON GROUND ANCHOR SCHEDULE ON SHEET A-1 FOR REQUIREMENTS SEE GROUND ANCHOR SCHEDULE ON SHEET A-1 FOR ANCHOR SPECIFICATIONS WOOD W/ SLED WALL STEEL EYEBOLT ZINC: %x6 (TABLE ON A-1) OR j i4°x6 (TABLE ON A-1) Ki 6° FRAME CLAMP W/ GAUVA M M4X. SRMP IYx"xB35MIN. CENT. TO ASTM 0-3953 ANSI 225.11 P.T. SKID FINISH GRADE BOLT (SEE SPEC SHEET) OPTIONAL 16°06°x4° OR (2) _ 8°x16k4° SOLID CAP BLOCKS REFER TO SCHEDULE SHEET A-1 M9TM' 1. REFER TO NOTES GROUND ANCHOR SCHEDULE ON SHEET A-1 FOR RE OF STABILIZER PLATES. 2. REFER TO GROUND ANCHOR SCHEDULE ON SHEET A-1 FOR ANCHOR DESCRIPTIONS AND SOIL USE CLASSIFICATIONS. 3. ANCHOR MUST BE PLACED AT EACH CORNER A MOMUM OF 6" FROM THE CORNER. HELIX ANCHOR DETAIL A-1 SCALE: 1-1/2°=I'-0" SHEARWALL ANCHOR TO BE PLACED HERE (".) SW-1 16°x16°x4° DOING. PAD OR (2) 8°xi6°x4° WK. PADS (TYP.) SEE 1/A-i FOR ADD'L INFORMATION 2 OPTIONAL ANCHOR DETAIL A—i SCALE: 1-1/2'4-0" 114ffi: 4 1. CONCRETE PADS ARE OPTONAL. A-T 2. DIMENSIONS SHOWN ARE NOMINAL S. ANCHORS ARE REQUIRED MIN. (4) PER BUILDING, (1) 0 EACH CORNER SHEARWALL 3 FLOOR FRAMING PLAN REFER . 4. ANCHOR TO ACNG1AES n SLEET L) L FOR A-1 SCALE: 1/4°=1'-0" (00 NOT SCALE DRAWING) ANCHOR SPACING & OPDOWL PAD LOCATION. 5. SPACE OPTIONAL PADS EQUALLY. GROUND ANCHOR SCHEDULE MODEL I PART DESCRIPTION SOIL GLASS M12H5/8 59080 / 59081 48" x %" ROD w/ (1) 6" HELIX 4A M12H3/4 59085 / 59094 48" x %4" ROD w/ (1) 6" HELIX 4A M1423/4 59128 42" x Y4" ROD w/ (2) 4" HELIX 4A M1483/4 59086 48" x X" ROD w/ (2) 4" HELIX 4A M121164 59250 36' x N4" ROD w/ (1) 4" HEDX & (1) 6" HELIX 4A N/A 59065 EYE ANCHOR — 48" X %" w/ (1) 6" HELIX 4A N/A 59045 EYE ANCHOR — 48" X Y4" w/ (1) 6" HELIX 4A M607 59099 60" X Y4" w/ (1) 7" HELIX 48 N/A 59040 EYE ANCHOR 60" X %4" w/ (1) 8" HELIX 4B OPTIONAL PAD SCHEDULE FOR ALL WIND SPEEDS AND EXPOSURES BUILDING WIDTH NUMBER OF PADS BY LENGTH UNDER EACH SKID 10'-0" 12'-0" 14'-0" 16'-0" 18'-01, 20'-0" 22'-0" 24'-O" 26'-0" 28'-0" 30'-0" 32'-0" 34'-0" 36'-0" 38'-0" 8'-0" 3 3 3 3 3 4 4 4 N/A N/A N/A N/A N/A N/A N/A N/A 10'-0" 3 3 3 4 4 4 4 5 5 5 5 N/A N/A N/A N/A N/A 1 V-2" 2 2 3 3 3 3 3 3 3 4 4 4 N/A N/A N/A N/A 12'-0" 2 2 3 3 3 3 3 3 4 4 4 4 4 4 N/A N/A 14'-0" 2 3 3 3 3 3 3 4 4 4 4 4 4 5 5 5 16'-0" 2 3 3 3 3 3 3 4 4 4 4 4 5 5 5 5 ANCHORING FOR 180 mph, WIND SPEED, EXPOSURE "C" - 318" ANCHOR BOLT BUILDING NUMBER OF ANCHORS EACH SIDE WALL WIDTH MAX' SPACING OVERTURN 10,-0" 12'-0" 14'-0" 16'-0" 18,-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" 34'-0" 36'-0" 38'-0" 8'-0" 3.15 5 5 6 7 7 8 8 9 10 10 11 12 12 13 14 14 10'-0" 3 5 6 6 7 8 8 9 10 10 11 12 12 13 14 14 15 11'-2" 3.98 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12'-0" 4.01 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 14'—O" 4.10 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 16'-0" 4.18 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 ANCHORING FOR 180 mph WIND SPEED, EXPOSURE "C" - 518" ANCHOR BOLT BUILDING NUMBER OF ANCHORS EACH SIDE WALL WIDTH MAX' SPACING OVERTURN 10'-0" 12'-0" 14'-0" 16'-0" 18'-0" 20'-0" 22'-0" 24'-0" 26'-0" 28'-0" 30'-0" 32'-0" 34'-0" 36'-0" 38'-0" 40'-0" 8'-0' 4.61 4 4 5 5 5 6 6 7 7 8 8 8 9 9 10 10 10'-0" 4.30 4 4 5 5 6 6 7 7 8 8 8 9 9 10 10 11 1 V-2" 5.84 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 12'-0" 5.88 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 14'—O" 6.01 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 16,-0" 6.13 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 16x16x4 NOMINAL PAD (2) ex8x4 NOMINAL PADS 4 PAD DETAILS A—i SCALE: 1-1/2"=1'-O" SKID PROJECT - ANCHORING FOR SHEDS FASTENING SCHEDULE / WIND LOADING DON VAN GERVE, P.E. SPECIALTY STRUCTURAL ENGINEER 978-943-6869 ALTERNATE DESIGN SOLUTIONS sreumRaLENNRFRIIxD oESWN6mnsTMLenaNsmu�s PHONE 215.355.4684 WWW.ALTEWNATEDESIONSOLUTIONS.COM ENGINEERING SERVICES PROVIDED FOR. PREMIER PORTABLE BUILDINGS 317 EAST STATE LINE ROAD SOUTH FULTON, TN 38257 WWW.PREMIERBUILDINGS.US REVISION DESCRIPTION DATE BY DATE: 4.30.18 PROJECT NO.: 17164 DRAWING BY: JH CHK BY: DVG DWG NO.: VAN •. " Ot No 61517 * 4/3Q18 E¢; '9T, STATE OF 'P ���ixSAONAk-��`x� 2of3 OCALA FLORIDA SHOP DBA FLORA-BAMA MFG 3082 NE 24TH STREF_T OCALA FL 34470 PROJECT - ANCHORING FOR SHEDS PRODUCT CUT SHEETS DON VAN CT RAL P.E. SPECIALTY STRUCTURAL ENGINEER 010 nAz cocn ALTERNATE DESIGN SOLUTIONS EINOCIDNAtENNINHWN6 MR PHONE: 215.&%4684 WWW.ALTERNATEDESIGNSOLUTIONS.COM LNUMUKIM )tKVAGLJ MMULu FOR.• PREMIER PORTABLE BUILDINGS 317 EAST STATE LINE ROAD SOUTH FULTON, TN 38257 WWW. PREM IERBUILDINGS. US DATE: 4.30.18 PROJECT NO.: 17164 DRAWING BY: JH CHK BY: DVG DWG NO.: A-2 3of3